7.6 ELECTRICAL SYSTEM CONNECTION<br />
- Connect the runways cables on the electric main board connectors;<br />
- Connect the feeding cable inside power unit;<br />
- Ensure the grounding or earth is connected.<br />
Figure 25 - ELECTRICAL SYSTEM CONNECTION<br />
7.7 CONNECTION OF THE PNEUMATIC LINES<br />
Warning: The connection of the lift to the general pneumatic system must be<br />
carried out only when the platforms have been raised to the top position to<br />
prevent mechanical safeties from disengaging unintentionally .<br />
The disengagement of the gear racks and the locking of the slip plates are carried out pneumatically<br />
(only for models AT e LTAT).<br />
The pneumatic supply at site (to which the pneumatic system of the lift is connected) must be<br />
equipped with a servicing unit composed of water separator, oiler and pressure reducer. These<br />
devices can be supplied by the manufacturer on request<br />
For the connection of the pneumatic lines proceed as follow:<br />
• Raise the lift to the final top position<br />
• Connect the pneumatic lines pre-assembled on the runways in the control desk according to<br />
the color marking<br />
• Connect the pneumatic system of the lift to the pneumatic supply at site<br />
• Check the pneumatic control operations for proper performance