The lift does not stop at the<br />

safety height (400 mm)<br />

The lift-table does not raise<br />

when push UP button (with<br />

selector qualified)<br />

The lift-table does not make<br />

auto-leveling<br />

The lift-table does not lower<br />

when DOWN button is pressed<br />

(with selector qualified)<br />

The lift-table doesn’t lower in a<br />

correct way (present tugs)<br />

The lift isn’t raising<br />

synchronous.<br />

The lifting capacity is limited<br />

The platform P2 doesn’t lower<br />

correctly<br />

The safety height limit switch is not adjusted<br />

correctly or it is faulty<br />

The electric board is faulty<br />

The selector is faulty (if the lift goes up instead<br />

of the lift-table)<br />

The electric board relay K1 is faulty (if the lift<br />

goes up instead of the lift-table)<br />

The lift-table height switch is not adjusted<br />

correctly or is faulty<br />

The cylinders solenoid valve block are dirty,<br />

defective or they are not powered<br />

The electric board is not operating<br />

The auto-leveling limit switch is not adjusted<br />

correctly or is faulty<br />

The auto-leveling solenoid valve is dirty, faulty<br />

or is not powered<br />

The electric board K4 relay is faulty<br />

The lift-table safety height limit switch is not<br />

adjusted correctly or is faulty<br />

The lift-table lowering solenoid valve is dirty,<br />

faulty or is not powered<br />

The electric board is not operating<br />

The motor does not work and does not<br />

disengage the mechanical safeties<br />

Dow button is faulty<br />

Presence of air in hydraulic circuit<br />

Presence of air or dripping in the hydraulic<br />

circuit.<br />

The lift-table lowering solenoid valve is faulty<br />

The cylinder gaskets can be damaged<br />

The oil in the tank is not enough<br />

The pump is faulty<br />

Safety valve is not settled properly<br />

The P2 auto-leveling limit switch is faulty<br />

The P1 auto-leveling limit switch is faulty<br />

Leveling solenoid valve does not operate<br />

Adjust or change the limit switch<br />

Replace electric board<br />

Replace the selector<br />

Replace the relay or electric board<br />

Adjust or change the limit switch<br />

Clean, if necessary replace or verify if powered<br />

and check magneto for damage<br />

Replace the electric board<br />

Adjust or change the limit switch<br />

Clean, if necessary replace or verify if powered<br />

and check magneto for damage<br />

Replace the relay or electric board<br />

Adjust or change the limit switch<br />

Clean, if necessary replace or verify if powered<br />

and check magneto for damage<br />

Check the fuses and replace the electric board if<br />

necessary<br />

Check the motor<br />

Check the DOWN button and connection for<br />

proper operation.<br />

Replace, if needed<br />

Bleed the hydraulic circuit<br />

Bleed the hydraulic circuit.<br />

Replace the solenoid valve<br />

Check and replace if necessary<br />

Fill oil in the tank<br />

Check the pump and replace if necessary.<br />

Ad just the valve setting<br />

Replace the limit switch<br />

Replace the limit switch<br />

Clean the valve or replace it if necessary