Locks and Electric Releases<br />
C•<strong>CURE</strong> 800<br />
There are a wide variety of locks and electric<br />
releases available for access control. In the main,<br />
there are three options available:<br />
• Surface or flush fitting<br />
• Fail safe or Fail secure<br />
• Monitored or unmonitored.<br />
Surface or flush is simply the method<br />
of installing the lock. This must take account of<br />
the aesthetics, security and type of door and<br />
frame.<br />
Fail-safe is a release that allows access when the<br />
power is removed from the operating coil. Fail<br />
safe locks therefore draw power from the access<br />
system when the door is in its closed state.<br />
Fail secure provides a degree of physical<br />
security when the lock has<br />
the power removed. This could be either in its<br />
normal operation or in a total power failure.<br />
Subject to the lock design. This type<br />
of installation offers a means of mechanical<br />
override for escape from the secure side of the<br />
door - handle or if acceptable paddle turn. and a<br />
mechanical override for entry by key. If this is not<br />
available then breakglass and keyswitch may be<br />
required as for the magnetic lock.<br />
<strong>Product</strong> Codes<br />
A34010<br />
Chubb 3R35 Latching Deadlock<br />
637.008.410<br />
Adams Rite 7100-Fail Secure 12 Vdc electric<br />
release (340mA) short face plate for Aluminium<br />
frames. Maximum operational gap (door to<br />
frame) 3mm. Jaw strength up to 900kg<br />
637.008.411<br />
Adams Rite 7113-Fail Secure 12 Vdc electric<br />
release (340mA) narrow face plate for timber<br />
frame or door. Maximum operational gap (door<br />
to frame) 3mm. Jaw strength up to 900kg<br />
637.008.412<br />
Adams Rite 7100-Fail Safe 12 Vdc electric<br />
release (340mA) short face plate for Aluminium<br />
frames. Maximum operational gap (door to<br />
frame) 3mm. Jaw strength up to 900kg<br />
637.008.413<br />
Adams Rite 7113-Fail Safe 12 Vdc electric<br />
release (340mA) narrow face plate for timber<br />
frame or door. Maximum operational gap (door<br />
to frame) 3mm. Jaw strength up to 900kg<br />
618.003.891<br />
A C release to suit Yale 88/89 latch<br />
Shear Locks<br />
These are magnetic locks designed for fitting into<br />
the transom or doorframe. The holding force this<br />
time draws up the armature plate allowing a<br />
locating pin to be put in place from the lock to<br />
the armature. This provides a physical<br />
mechanism against the side shear force applied<br />
to the door when trying to overcome the lock.<br />
These locks can be fitted to swing through doors<br />
but the re-alignment of the door(s) is critical.<br />
<strong>Product</strong> Code<br />
637.008.414<br />
Adams Rite Armlock 1354 Mini Electro-Shear<br />
magnet mortice fitting - 12 or 24Vd.c.. Up to<br />
1500kg holding force. Requires 1.5 Amps Pull In<br />
@ 12Vd.c. (Quiescent 500mA @ 12Vd.c.).<br />
Door Loops<br />
Where locks or releases are fitted into the controlled door and require electrical/monitoring connection, a door loop is required to allow a flexible connection<br />
to be made from the door frame to the moving leaf.<br />
A33305<br />
A33306<br />
<strong>Product</strong> Codes<br />
A33305<br />
Concealed Door Loop<br />
A33306<br />
Surface Door Loop Arm Conduit<br />