MARATON HHE - power supply system for<br />
Hazardous Hostile Radiation Environment<br />
MARATON is a series of MAgnetic field and RAdiation TOleraNt power supplies.<br />
Strategy for magnetic field tolerance: water cooling (until 300G), screened components<br />
(until 1200G)<br />
Strategies for radiation tolerance: special components (until 30Gy), radiation sensible<br />
components placed remotely (protons: until 140 Gy, neutrons: until 722 Gy)<br />
The high density very powerful and compact low-voltage floating power supply system<br />
MARATON HHE possesses in a 3U high box 12 independent channels of 300W each. In parallel<br />
operation the output power per channel can be boosted to 600W / 900W /1200W... with 6 / 4 /<br />
3... channel utilization.<br />
Dynamic behavior adjustable by internal jumper (long-short sensed distances to loads).<br />
MARATON HHE Features<br />
Up to 12 independent, potential free outputs, total up to 3 kW DC output power (nom. 385VDC<br />
inp.), 3,6kW water cooled<br />
Fully controlled, adjustable trip levels<br />
Adjustable voltages, current limits, temperature limits and OVP-trip levels<br />
Extremely low noise and ripple<br />
CE conform EN 50 081/82 part 2 or 1, safety in accordance with EN 60 950<br />
<strong>VME</strong> compatible remote monitoring and control module for 12 channels with Ethernet (TCP/IP)<br />
interface (for Standard Environment)<br />
If necessary, 385VDC input from PFC module (with standard mains input) placed on remote bin<br />
Water cooled (recommended) or by forced air<br />
MaratonHHE consists of a power box containing up to six dual modules MDC or MDM. A control<br />
card (RCM) is placed on a remote <strong>VME</strong> crate and a mains input module with PFC is placed, if<br />
necessaty, on a remote bin. For the limits on magnetic field and radiation see the picture in pg.<br />
93.<br />
MARATON HHE power box mounted in<br />
bin<br />
MARATON Remote Controller (RCM) Features<br />
Measurement of Voltage & Current Monitor Outputs<br />
12 Channels (1x12 or 2 x