09.03.2014 Views

6U VME 6023 Crate Series

6U VME 6023 Crate Series

6U VME 6023 Crate Series

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical details of WIENER NIM and CAMAC crates<br />

UEN 01 NIM Bin 7U<br />

7U NIM-Bin for 12 high powered NIM-Modules, rugged heavy-duty construction with 6mm side<br />

panels depth 525mm. Power supply is plugged in and locked from rear side. The bin provides 2U<br />

space for a fan tray unit. The power-bus-system is equipped with 12 high-quality long-life NIM<br />

connectors parallel wired. Connector pins made of massive brass, gold plated.<br />

Current rail system for +/-6V and Ground. Spliced wiring and additional power-connector pins<br />

have been used to allow currents of 25A for +/-12V lines now. CERN specifications are fulfilled<br />

entirely. The wiring across the NIM connectors is achieved under a screening cover.<br />

When used according to CERN specifications the bin wiring carries mains voltage. All this mains<br />

cable are arranged as screened lines to prevent effects of mains distortions to secondary circuits.<br />

Due to not fulfilling the restrictions of EN 60950, UL 1950, etc., power supply and fan tray are not<br />

CE-marked. When used in combination with CE conform power supplies (CEP) and fan tray (CEL)<br />

mains voltage will be conducted through a separated power cord to the fan tray. This power cord<br />

is fixed at fan tray side and has to be plugged to the power supply. The bin is free of mains<br />

voltage then.<br />

UEN 01 Bin<br />

Current max. ratings:<br />

Voltage Line Current / slot Current / bin Comment<br />

+/-6V 13A 65A sensed<br />

+/-12V 13A 26A sensed<br />

+/-24V 13A 13A sensed<br />

GND 13<br />

115V AC 0.5A Secondary<br />

UEN 03 NIM Bin 5U<br />

Non-ventilated 525mm deep 5U NIM bin with 12 slot. Same mechanical performance as UEN 01<br />

above. Control panel with mains switch, mains lamp (yellow/red), LED's for status (green),<br />

overheat (yellow), overload (red), Alarm output (LEMO 00, open collector), test sockets and<br />

monitor LED's for all DC-Voltages according to CERN specifications.<br />

UEN 03 Bin<br />

Current max. ratings:<br />

Voltage Line Current / slot Current / bin Comment<br />

+/-6V 13A 65A sensed<br />

+/-12V 13A 13A (optional 26A) sensed<br />

+/-24V 13A 13A sensed<br />

GND 13<br />

115V AC 0.5A Secondary<br />

UEN 04 NIM Bin Compact 5U<br />

Rigid non ventilated construction for powering by UEP 15 Slot-Power-Supply. Wired for use of 10<br />

NIM slots. Slot 11 and 12 occupied by power supply. DC-power feed in via standard NIM<br />

connector on slot 12 position. For +/-6V and ground each line has two pins in parallel to reduce<br />

the transition resistance.<br />

UEN 04 Bin<br />

Current maximum ratings:<br />

Voltage Line Current / slot Current / bin Comment<br />

+/-6V 13A 26A not sensed<br />

+/-12V 13A 13A not sensed<br />

+/-24V 13A 13A not sensed<br />

GND 13 13A<br />

115V AC 0.5A Secondary<br />

UEN 04T NIM Bin Compact transportable<br />

7½ slot portable mini NIM bin with 5 slots free for NIM modules, 2½ slots occupied by UEP 15<br />

power supply. Solid steel- aluminum construction.<br />

UEN 04 Portable<br />

The top cover is equipped with a handle and has lateral perforation in order to make convection<br />

cooling efficient. 22mm high rubber feet for non-destructive table top operation enables also an<br />

adequate cooling air entrance to bottom side. The power cord is plugged to the rear side of the<br />

power supply directly.<br />

All NIM bins have clean earth wired with 0,25mm²<br />