6U VME 6023 Crate Series
6U VME 6023 Crate Series
6U VME 6023 Crate Series
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Intelligent NIM / CAMAC Fan Tray UEL03 / CEL03<br />
CERN spec. conform fan tray unit equipped with alphanumeric monitoring and three long life<br />
DC axial fans, either with frontal or bottom air entry (400m³/h or >540m³/h airflow). Static<br />
pressure up to 8 mm H 2 O column. MFOT (Maintenance Free Operation Time) > 65 000h / 40°C.<br />
Fan speed is variable from 1200 to 3000 rpm<br />
The monitoring can be toggled to display: voltages, currents, fan speed, temperature of<br />
incoming air, total power dissipation by inserted modules, network address (if installed). Displayed<br />
currents are scaleable to obtain true values. In case of malfunction the type of error will be<br />
displayed.<br />
Additional LED information is showing:<br />
Status (Green):<br />
all values inside tolerance<br />
Fan fail (Yellow):<br />
one or more fans fail<br />
Over Heat (Yellow): power supply overheated<br />
The fan tray monitoring can be set to Programming Mode. This mode allows programming of<br />
all key functions and for 336-power supply values like current limits, status thresholds, etc.. The<br />
Status Signal is superposed by an additional pulse modulated information (from PS/CS 336 only)<br />
to extend the CERN spec. monitoring and control.<br />
Different Remote Control Interface are installable.<br />
1. CAN-bus<br />
2. HS CEANET<br />
3. IEC Bus<br />
UEN 01 Front View<br />
CAN-bus Remote Control and Monitoring Software can control up to 126 crates within a network.<br />
The user can control and program remotely every crate parameter and On/Off via the interface<br />
such as:<br />
<strong>Crate</strong> Identification<br />
All voltages, currents and temperature, status signals<br />
Over- under voltage trip off points and current limit adjustment (with 336 only)<br />
Average fan speed and display of every single fan<br />
Configuration and adjustment (for service and maintenance)<br />
CERN spec. monitoring connector<br />
CERN Spec. Monitor Connector<br />
Important signals of the »M« power supplies have been wired to the 36 pin ribbon connector.<br />
This connector monitors:<br />
Power fail<br />
Overload<br />
Overheat cut off<br />
Status (pot. free contact)<br />
All output voltages (Voltage outputs are internally protected by resistors against short<br />
circuit.)<br />
Disable signal prevents cut-off function<br />
Inhibit signal keeps DC off and stops acoustic alarms<br />
CE conform <strong>Crate</strong> versions / CE conform mains connection<br />
CERN spec. wired bins allow to switch crates on and off via the mains switch at the fan tray.<br />
Current rules as CE60950 and UL1950 claim for primary to secondary isolations, which are not<br />
considered in the appropriate CERN specifications. Therefore WIENER formed a compromise to<br />
fulfill CE and UL safety restriction as well as CERN specifications by separating the mains wiring.<br />
NIM Compact Slot Power Supply UEP 15<br />
Plug in power supply for use in UEN 04 bins or for powering every non-powered extant NIM bin.<br />
UEP 15 features all 6 voltages, stabilized by adjustable monolithic voltage regulators, on rear<br />
NIM connector with standard NIM pin out. Ground and 6V outputs are spliced-wired to two pins<br />
for minimized voltage drop.<br />
UEN 04 Portable<br />
The integrated blower cools heat sink, components and the toroid transformer. Voltage regulators<br />
and transformer are protected against over temperature. Over- under voltage detector (limits ca.<br />
+/-3% of nominal voltages) activates mains cutting relay (red signal “bad status” at front panel).<br />
Mains voltages: 100, 115, 225, 240VAC by use of different internal transformer taps.<br />
Optional CAN-bus interface for DC voltage monitoring and remote on/off via rear 9 pin sub D<br />
connector<br />
18