‘‘E’’ Series electrical<br />
Dedicated Neutral System<br />
conduit jumper<br />
description<br />
nominal<br />
length pattern no. list<br />
Conduit jumper 126 EE1C126-(N3/N4)e $186.<br />
132 EE1C132-(N3/N4)e 190.<br />
144 EE1C144-(N3/N4)e 201.<br />
Equity<br />
Panels, Connections, Power and<br />
Accessories<br />
Terminal block (N3/N4) EE1TB-(N3/N4)e 44.<br />
Duplex receptacle EE1RIIINe 28.<br />
EE1RIINe 28.<br />
EE1RINe 28.<br />
EE1RIVNe 28.<br />
Order Code<br />
Specification Information<br />
Application Notes<br />
Example: EE1C30-N3<br />
EE1C Conduit jumper<br />
30 Length<br />
N3 8-wire dedicated neutral<br />
8-wire N3 = 2+1 system (2 hots and<br />
2 neutrals sharing one ground, 1<br />
isolated hot and 1 isolated neutral<br />
on an isolated ground)<br />
10-wire N4 = 2+2 system (2 hots<br />
and 2 neutrals sharing one ground,<br />
2 hots and 2 neutrals sharing<br />
another ground)<br />
Jumpers:<br />
Transmit power circuits from one<br />
panel mouted terminal block to<br />
another. Can carry power through<br />
panels where no terminal blocks are<br />
installed. The length of the jumper<br />
corresponds to the distance between<br />
the terminal blocks.<br />
To calculate the correct length:<br />
1. Add widths of both panels<br />
containing terminal blocks.<br />
2. Divide by two.<br />
3. Add width of any non-electrified<br />
panels in-between.<br />
The result is the correct jumper<br />
length.<br />
Example:<br />
36+24=60<br />
60÷2=30<br />
30+48=78<br />
Order EE1C78-N3<br />