‘‘O’’ Series electrical<br />
Ceiling infeed/base infeed modules<br />
Equity<br />
description type w d h pattern no. P1<br />
Raceway ceiling infeed module - ‘‘O’’ Series 8-wire 4 – 48 OIM48H-8 $366. $15. $25.<br />
4 – 53 OIM53H-8 410. 15. 25.<br />
4 – 60 OIM60H-8 454. 15. 25.<br />
4 – 65 OIM65H-8 470. 15. 25.<br />
4 – 80 OIM80H-8 576. 15. 25.<br />
add for<br />
P2<br />
add for<br />
P3<br />
Base infeed module - ‘‘O’’ Series 8 wire (non-handed) 48 – – OBI 159. n/a n/a<br />
72 – – OBI72 193. n/a n/a<br />
Ceiling infeed harness - 19.5’ length ‘‘O’’ Series 8-wire OEICH-8 316. n/a n/a<br />
Electrical system adapter jumper ‘‘O’’ Series to ‘‘E’’ Series adapter jumper EE1AP12-8 83. n/a n/a<br />
Order Code<br />
Example: OIM60H-8, E<br />
OIM Raceway ceiling infeed<br />
module<br />
60 Height (panel)<br />
H Hard wired<br />
8 8-wire electrical<br />
E Soft grey trim<br />
Specification Information<br />
For ceiling infeed module:<br />
Specify module trim color.<br />
Note:<br />
‘‘O’’ series and ‘‘E’’ series electrical<br />
components are not<br />
interchangeable.<br />
70<br />
Application Notes<br />
Raceway ceiling infeed module:<br />
Supplies power from building<br />
source with hard-wired capabilities.<br />
Vertical segment of wiring connects<br />
to a building junction box above<br />
finished ceiling.<br />
Ceiling height above panel cannot<br />
be more than 6 feet. Total module<br />
height is 79. Length of conduit<br />
harness is 19’6.<br />
The rigid infeed tube accommodates<br />
the power conduit and ten 3 /8<br />
communications cables which are<br />
laid-in by removal of module front<br />
access cover. Infeed module can be<br />
attached to any available post<br />
location perpendicular to the panel<br />
run. The module cannot be used for<br />
panel support.<br />
No ‘‘hang-on’’ capabilities.<br />
Ceiling plate and tube are white to<br />
integrate with standard ceilings.<br />
Base infeed modules:<br />
An infeed conduit that connects to<br />
the wall or floor outlet box of a<br />
building’s power supply and plugs<br />
into a terminal block in panel<br />
baseboard. Power entry can be from<br />
either left or right side of panel.<br />
Injection molded cover conceals the<br />
baseboard connection and is<br />
reversible for either left or right<br />
entry. Can be field-cut to proper<br />
lengths. Color is black. A terminal<br />
block must be ordered separately.<br />
Electrical system adaptor jumper:<br />
A12 jumper which connects an<br />
‘‘O’’ series terminal block to an ‘‘E’’<br />
series jumper.<br />