23.03.2014 Views

download - Knoll

download - Knoll

download - Knoll

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

‘‘O’’ Series electrical<br />

Ceiling infeed/base infeed modules<br />

Equity<br />

description type w d h pattern no. P1<br />

Raceway ceiling infeed module - ‘‘O’’ Series 8-wire 4 – 48 OIM48H-8 $366. $15. $25.<br />

4 – 53 OIM53H-8 410. 15. 25.<br />

4 – 60 OIM60H-8 454. 15. 25.<br />

4 – 65 OIM65H-8 470. 15. 25.<br />

4 – 80 OIM80H-8 576. 15. 25.<br />

add for<br />

P2<br />

add for<br />

P3<br />

Base infeed module - ‘‘O’’ Series 8 wire (non-handed) 48 – – OBI 159. n/a n/a<br />

72 – – OBI72 193. n/a n/a<br />

Ceiling infeed harness - 19.5’ length ‘‘O’’ Series 8-wire OEICH-8 316. n/a n/a<br />

Electrical system adapter jumper ‘‘O’’ Series to ‘‘E’’ Series adapter jumper EE1AP12-8 83. n/a n/a<br />

Order Code<br />

Example: OIM60H-8, E<br />

OIM Raceway ceiling infeed<br />

module<br />

60 Height (panel)<br />

H Hard wired<br />

8 8-wire electrical<br />

E Soft grey trim<br />

Specification Information<br />

For ceiling infeed module:<br />

Specify module trim color.<br />

Note:<br />

‘‘O’’ series and ‘‘E’’ series electrical<br />

components are not<br />

interchangeable.<br />

70<br />

Application Notes<br />

Raceway ceiling infeed module:<br />

Supplies power from building<br />

source with hard-wired capabilities.<br />

Vertical segment of wiring connects<br />

to a building junction box above<br />

finished ceiling.<br />

Ceiling height above panel cannot<br />

be more than 6 feet. Total module<br />

height is 79. Length of conduit<br />

harness is 19’6.<br />

The rigid infeed tube accommodates<br />

the power conduit and ten 3 /8<br />

communications cables which are<br />

laid-in by removal of module front<br />

access cover. Infeed module can be<br />

attached to any available post<br />

location perpendicular to the panel<br />

run. The module cannot be used for<br />

panel support.<br />

No ‘‘hang-on’’ capabilities.<br />

Ceiling plate and tube are white to<br />

integrate with standard ceilings.<br />

Base infeed modules:<br />

An infeed conduit that connects to<br />

the wall or floor outlet box of a<br />

building’s power supply and plugs<br />

into a terminal block in panel<br />

baseboard. Power entry can be from<br />

either left or right side of panel.<br />

Injection molded cover conceals the<br />

baseboard connection and is<br />

reversible for either left or right<br />

entry. Can be field-cut to proper<br />

lengths. Color is black. A terminal<br />

block must be ordered separately.<br />

Electrical system adaptor jumper:<br />

A12 jumper which connects an<br />

‘‘O’’ series terminal block to an ‘‘E’’<br />

series jumper.<br />

= <strong>Knoll</strong>Now

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!