24.03.2014 Views

Pluto Safety PLC details - Products For Industry

Pluto Safety PLC details - Products For Industry

Pluto Safety PLC details - Products For Industry

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical data - Gateway CANopen<br />

Manufacturer<br />

<br />

1<br />

Article number/ordering data: GATE-C1<br />

Databuses:<br />

<strong>Pluto</strong> databus speeds:<br />

-<strong>Pluto</strong> databus CAN (isolated)<br />

-CANopen CAN (isolated)<br />

100, 200, 250, 400, 500, 800 and<br />

1000 kbit/s<br />

(automatic speed detection)<br />

2<br />

CANopen speeds:<br />

<br />

switch)<br />

10, 20, 50, 100, 125, 250, 500, 800<br />

and 1000 kbit/s (via software)<br />

3<br />

CANopen address:<br />

<br />

CANopen version:<br />

Connections:<br />

Status indications:<br />

”Version 4.02 of the CiA Draft Standard<br />

<br />

<br />

(included)<br />

Front, 5-pole terminal for CANopen<br />

(included)<br />

Bottom, 2-pole terminal for 24 V DC<br />

(included)<br />

<strong>Pluto</strong> databus status indication via LED<br />

CANopen status indication via LED<br />

119 mm<br />

4<br />

5<br />

Operating voltage: 24 V DC, -15% till +20%<br />

Current at 24 V: < 100 mA (recommended fuse ≤6 A)<br />

Dimensions (w x h x d):<br />

22.5 x 101 x 119 mm<br />

Installation:<br />

<br />

101 mm<br />

6<br />

Operating temperature (ambient): -10°C to + 55ºC<br />

Temperature, transport and storage: -25°C to + 55ºC<br />

Humidity:<br />

EN 60 204-1 50% at 40ºC (ambient<br />

90% at 20ºC)<br />

Enclosure classification:<br />

<br />

<br />

22,5 mm<br />

7<br />

Gateway block schematic diagram - <strong>Pluto</strong> CANopen<br />

8<br />

9<br />

10<br />

11<br />

12<br />

www.jokabsafety.com<br />

2:21<br />

13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!