Pluto Safety PLC details - Products For Industry
Pluto Safety PLC details - Products For Industry
Pluto Safety PLC details - Products For Industry
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Technical data - Gateway CANopen<br />
Manufacturer<br />
<br />
1<br />
Article number/ordering data: GATE-C1<br />
Databuses:<br />
<strong>Pluto</strong> databus speeds:<br />
-<strong>Pluto</strong> databus CAN (isolated)<br />
-CANopen CAN (isolated)<br />
100, 200, 250, 400, 500, 800 and<br />
1000 kbit/s<br />
(automatic speed detection)<br />
2<br />
CANopen speeds:<br />
<br />
switch)<br />
10, 20, 50, 100, 125, 250, 500, 800<br />
and 1000 kbit/s (via software)<br />
3<br />
CANopen address:<br />
<br />
CANopen version:<br />
Connections:<br />
Status indications:<br />
”Version 4.02 of the CiA Draft Standard<br />
<br />
<br />
(included)<br />
Front, 5-pole terminal for CANopen<br />
(included)<br />
Bottom, 2-pole terminal for 24 V DC<br />
(included)<br />
<strong>Pluto</strong> databus status indication via LED<br />
CANopen status indication via LED<br />
119 mm<br />
4<br />
5<br />
Operating voltage: 24 V DC, -15% till +20%<br />
Current at 24 V: < 100 mA (recommended fuse ≤6 A)<br />
Dimensions (w x h x d):<br />
22.5 x 101 x 119 mm<br />
Installation:<br />
<br />
101 mm<br />
6<br />
Operating temperature (ambient): -10°C to + 55ºC<br />
Temperature, transport and storage: -25°C to + 55ºC<br />
Humidity:<br />
EN 60 204-1 50% at 40ºC (ambient<br />
90% at 20ºC)<br />
Enclosure classification:<br />
<br />
<br />
22,5 mm<br />
7<br />
Gateway block schematic diagram - <strong>Pluto</strong> CANopen<br />
8<br />
9<br />
10<br />
11<br />
12<br />
www.jokabsafety.com<br />
2:21<br />
13