Download the catalogue - legrand
Download the catalogue - legrand
Download the catalogue - legrand
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
pour underfloor exemple power : xxxxxxx distribution systems<br />
xxxxxxxx Electrak 28 standard system<br />
pour underfloor exemple power : xxxxxxx distribution systems<br />
xxxxxxxx Electrak 25 low noise system<br />
plug-in key code<br />
plug-in key code<br />
YA5123<br />
JA2123<br />
YF5010<br />
YW5010<br />
JF2010<br />
JW2010<br />
YP5332<br />
JP2332<br />
Technical caracteristics (p. 15)<br />
Technical caracteristics (p. 15)<br />
Conform to BS EN 60 439-1, BS EN 60 439-2 and BS 7671: 2008 IEE<br />
Wiring Regulations<br />
ASTA approved<br />
14<br />
@<br />
Pack Cat.Nos Electrak 28 standard floor busbar system<br />
Standard system with red components<br />
Underfloor system consist of continuous lengths of<br />
power track which are fed from <strong>the</strong> distribution board<br />
via busbar feed boxes and can be installed in a raised<br />
floor clearance height 48 mm<br />
Busbars<br />
Rated current: 63 A<br />
230/400 VA - 50/60 Hz<br />
300 mm socket centres<br />
Each busbar is equipped with connectors (one male<br />
and one female) at each extremity. Connection of<br />
busbars is made by simply snap fi tting<br />
Access to power is provided along <strong>the</strong> power track<br />
by simply plugging tap-off units into shuttered<br />
socket outlets<br />
Supplied with fl oor fi xing brackets<br />
Length (m) No. of sockets No. fi xing brackets<br />
1 YA5123 1.2 4 2<br />
1 YA5243 2.4 8 2<br />
1 YA5363 3.6 12 3<br />
Busbar feed boxes<br />
1 YF5010 With T, N and L connector terminals<br />
With Ø25 mm cable conduit fi xing hole<br />
Flexible interlinks<br />
Consist of two busbar connectors (male and female)<br />
Used to connect 2 busbars when changing direction<br />
1 YW5000 Without cable or conduit<br />
1 YW5010 With 1.2 m metal fl exible conduit and cables<br />
1 YW5020 With 2.4 m metal fl exible conduit and cables<br />
Tap-off units<br />
Can be connected directly through <strong>the</strong> fl oor via<br />
grommet outlets (p. 46) to workstations (p. 48)<br />
Supplied with Ø16 mm fl exible conduit and<br />
T, N and L tap-off connectors<br />
1 YP5332 32 A unfused - length 3 m<br />
1 YP5532 32 A unfused - length 5 m<br />
1 YP5327 13 A fused 543-7 - length 3 m<br />
1 YP5527 13 A fused 543-7 - length 5 m<br />
Conform to BS EN 60 439-1, BS EN 60 439-2 and BS 7671: 2008 IEE<br />
Wiring Regulations<br />
ASTA approved<br />
@<br />
Pack Cat.Nos Electrak 25 low noise (clean earth) floor<br />
busbar system<br />
Standard system with green components<br />
Underfloor system consist of continuous lengths of<br />
power track which are fed from <strong>the</strong> distribution board<br />
via busbar feed boxes and can be installed in a raised<br />
floor clearance height 48 mm<br />
Busbars<br />
Rated current: 63 A<br />
230/400 VA - 50/60 Hz<br />
300 mm socket centres<br />
Each busbar is equipped with connectors (one male<br />
and one female) at each extremity. Connection of<br />
busbars is made by simply snap fi tting<br />
Access to power is provided along <strong>the</strong> power track<br />
by simply plugging tap-off units into shuttered<br />
socket outlets<br />
Supplied with fl oor fi xing brackets<br />
Length (m) No. of sockets No. fi xing brackets<br />
1 JA2123 1.2 4 2<br />
1 JA2243 2.4 8 2<br />
1 JA2363 3.6 12 3<br />
Busbar feed boxes<br />
1 JF2010 With T, N, L and clean T connector terminals<br />
With Ø25 mm cable conduit fi xing hole<br />
Flexible interlinks<br />
Consist of two busbar connectors (male and female)<br />
Used to connect 2 busbars when changing direction<br />
1 JW2000 Without cable or conduit<br />
1 JW2010 With 1.2 m metal fl exible conduit and cables<br />
1 JW2020 With 2.4 m metal fl exible conduit and cables<br />
Tap-off units<br />
Can be connected directly through <strong>the</strong> fl oor via<br />
grommet outlets (p. 46) to workstations (p. 48)<br />
Supplied with Ø16 mm fl exible conduits and<br />
T, N, L and clean T connectors<br />
1 JP2332 32 A unfused - length 3 m<br />
1 JP2532 32 A unfused - length 5 m<br />
1 JP2327 13 A fused 543-7 - length 3 m<br />
1 JP2527 13 A fused 543-7 - length 5 m<br />
Electrak underdesk modules (p. 48)