pour underfloor exemple power : xxxxxxx distribution systems<br />

xxxxxxxx Electrak 28 standard system<br />

pour underfloor exemple power : xxxxxxx distribution systems<br />

xxxxxxxx Electrak 25 low noise system<br />

plug-in key code<br />

plug-in key code<br />

YA5123<br />

JA2123<br />

YF5010<br />

YW5010<br />

JF2010<br />

JW2010<br />

YP5332<br />

JP2332<br />

Technical caracteristics (p. 15)<br />

Technical caracteristics (p. 15)<br />

Conform to BS EN 60 439-1, BS EN 60 439-2 and BS 7671: 2008 IEE<br />

Wiring Regulations<br />

ASTA approved<br />

14<br />

@<br />

Pack Cat.Nos Electrak 28 standard floor busbar system<br />

Standard system with red components<br />

Underfloor system consist of continuous lengths of<br />

power track which are fed from <strong>the</strong> distribution board<br />

via busbar feed boxes and can be installed in a raised<br />

floor clearance height 48 mm<br />

Busbars<br />

Rated current: 63 A<br />

230/400 VA - 50/60 Hz<br />

300 mm socket centres<br />

Each busbar is equipped with connectors (one male<br />

and one female) at each extremity. Connection of<br />

busbars is made by simply snap fi tting<br />

Access to power is provided along <strong>the</strong> power track<br />

by simply plugging tap-off units into shuttered<br />

socket outlets<br />

Supplied with fl oor fi xing brackets<br />

Length (m) No. of sockets No. fi xing brackets<br />

1 YA5123 1.2 4 2<br />

1 YA5243 2.4 8 2<br />

1 YA5363 3.6 12 3<br />

Busbar feed boxes<br />

1 YF5010 With T, N and L connector terminals<br />

With Ø25 mm cable conduit fi xing hole<br />

Flexible interlinks<br />

Consist of two busbar connectors (male and female)<br />

Used to connect 2 busbars when changing direction<br />

1 YW5000 Without cable or conduit<br />

1 YW5010 With 1.2 m metal fl exible conduit and cables<br />

1 YW5020 With 2.4 m metal fl exible conduit and cables<br />

Tap-off units<br />

Can be connected directly through <strong>the</strong> fl oor via<br />

grommet outlets (p. 46) to workstations (p. 48)<br />

Supplied with Ø16 mm fl exible conduit and<br />

T, N and L tap-off connectors<br />

1 YP5332 32 A unfused - length 3 m<br />

1 YP5532 32 A unfused - length 5 m<br />

1 YP5327 13 A fused 543-7 - length 3 m<br />

1 YP5527 13 A fused 543-7 - length 5 m<br />

Conform to BS EN 60 439-1, BS EN 60 439-2 and BS 7671: 2008 IEE<br />

Wiring Regulations<br />

ASTA approved<br />

@<br />

Pack Cat.Nos Electrak 25 low noise (clean earth) floor<br />

busbar system<br />

Standard system with green components<br />

Underfloor system consist of continuous lengths of<br />

power track which are fed from <strong>the</strong> distribution board<br />

via busbar feed boxes and can be installed in a raised<br />

floor clearance height 48 mm<br />

Busbars<br />

Rated current: 63 A<br />

230/400 VA - 50/60 Hz<br />

300 mm socket centres<br />

Each busbar is equipped with connectors (one male<br />

and one female) at each extremity. Connection of<br />

busbars is made by simply snap fi tting<br />

Access to power is provided along <strong>the</strong> power track<br />

by simply plugging tap-off units into shuttered<br />

socket outlets<br />

Supplied with fl oor fi xing brackets<br />

Length (m) No. of sockets No. fi xing brackets<br />

1 JA2123 1.2 4 2<br />

1 JA2243 2.4 8 2<br />

1 JA2363 3.6 12 3<br />

Busbar feed boxes<br />

1 JF2010 With T, N, L and clean T connector terminals<br />

With Ø25 mm cable conduit fi xing hole<br />

Flexible interlinks<br />

Consist of two busbar connectors (male and female)<br />

Used to connect 2 busbars when changing direction<br />

1 JW2000 Without cable or conduit<br />

1 JW2010 With 1.2 m metal fl exible conduit and cables<br />

1 JW2020 With 2.4 m metal fl exible conduit and cables<br />

Tap-off units<br />

Can be connected directly through <strong>the</strong> fl oor via<br />

grommet outlets (p. 46) to workstations (p. 48)<br />

Supplied with Ø16 mm fl exible conduits and<br />

T, N, L and clean T connectors<br />

1 JP2332 32 A unfused - length 3 m<br />

1 JP2532 32 A unfused - length 5 m<br />

1 JP2327 13 A fused 543-7 - length 3 m<br />

1 JP2527 13 A fused 543-7 - length 5 m<br />

Electrak underdesk modules (p. 48)