AS-interface is a single-master system.<br />

<strong>Communication</strong>s processors (CPs) are<br />

available <strong>for</strong> SIMATIC families which serve<br />

as master <strong>for</strong> controlling processor or<br />

field communication.<br />

Extended AS-Interface Specification V2.1<br />

permits interfacing of up to 62 slaves.<br />

Thanks to the integration of analog-value<br />

processing in the masters, accessing<br />

analog values is just as easy as accessing<br />

digital values. A DP/AS-Interface Link is<br />

used to interface the SIMATIC S7-400 ®<br />

to the AS-i network. DP/AS-Interface Link<br />

20E in IP20 is available <strong>for</strong> connecting<br />

the AS-Interface network directly to<br />

PROFIBUS DP, making it possible to use<br />

AS-i as PROFIBUS DP subnetwork.<br />

This is how you save costs<br />

AS-Interface replaces high-overhead<br />

cable harnesses <strong>and</strong> connects binary<br />

actuators <strong>and</strong> sensors such as proximity<br />

switches, valves <strong>and</strong> indicator lights to a<br />

programmable controller, <strong>for</strong> example<br />

SIMATIC. In practice, this means problemfree<br />

installation, since data <strong>and</strong> power<br />

are transported over a single cable.<br />

Thanks to a specially developed cable<br />

<strong>and</strong> cable-piercing technology, the<br />

AS-Interface cable can be tapped at any<br />

point. This concept gives you enormous<br />

flexibility <strong>and</strong> is exceptionally cost-saving.<br />

Special knowledge of installation <strong>and</strong><br />

commissioning are unnecessary. In<br />

addition, easy cable installation, a clear<br />

cable structure <strong>and</strong> the special design of<br />

the AS-i cable not only greatly reduce the<br />

risk of errors, but also the overhead <strong>for</strong><br />

service <strong>and</strong> maintenance.<br />

Power supply<br />

LOGO!<br />

St<strong>and</strong>ard sensor,<br />

e.g. inductive<br />

BERO<br />

AS-i panelboard<br />

(without AS-interface chip)<br />

Signal column<br />

Annunciator<br />

K45<br />

(with AS-interface<br />

chip) <strong>for</strong><br />

connection of<br />

st<strong>and</strong>ard<br />

sensors<br />

User submodule<br />

K60<br />

IP 65 motor starter<br />

AS-i panelboard<br />

Ultrasonic BERO<br />

with integrated<br />

AS-interface<br />

St<strong>and</strong>ard encoder,<br />

e.g. position switch<br />

You will find the<br />

technical specifications<br />

<strong>for</strong><br />

AS-Interface 14<br />

9<br />

on page