Model TV12<br />

REF 00T0400 (230V/50-60Hz), REF 00T0405 (115V/60Hz)<br />

MAIN CHARACTERISTICS<br />

The TV12 is a unique viscosity bath with a small footprint. The TV12 can be operated from ambient +5°C up to<br />

+120°C (41..248°F). With the use of the built-in cooling coil and an external <strong>Tamson</strong> cooler, span lies 5K<br />

above the temperature of the cooling liquid. The TV12 has a bath volume of only 12 liters and a unique<br />

stability of 0.005K. The TV12 offers 1 row of 4 holes with lids. These openings will accommodate glass capillary<br />

viscometers in viscometer holders. A permanent light is located in the top plate to supply clear light and<br />

guarantees optimal visibility inside the bath. A bath overflow outlet protects from expanding bath oil when the<br />

bath filling is too high. A bath drain is standard included. The bath is fitted with a double window of which the<br />

front pane is detachable for cleaning purposes.<br />

Range<br />

Reading<br />

Used materials inside bath<br />

Setting ±<br />

Offset<br />

..120 (248°F)<br />

Standard °C, °F on request<br />

Stainless Steel 304, PTFE<br />

0.01°C<br />

0.01°C<br />

Stability ± 0.005K<br />

Heating<br />

Heaters 2<br />

Bath volume 12<br />

Number of lids 4<br />

Window<br />

Opening lid<br />

Opening bath<br />

Depth bath<br />

1280 W<br />

246 * 250 mm<br />

51(dia) mm<br />

244 * 75 mm<br />

300 mm<br />

OPTIONS<br />

REF 07T0080 Optical Level indicator<br />

REF 13T6200 Levelling platform<br />

REF 13T6210 Calibration/metal block<br />

REF 13T6220 Lid + High contrast white glass back plate<br />

REF 13T3006.09 Lid for 4 Cannon-Fenske Routine viscometers<br />

TV12<br />

ACCESSORIES<br />

REF 10T6065 Viscohanger<br />

REF 10T6001 Viscometer holder ‘Ubbelohde’<br />

REF 10T6061 Viscometer holder ‘Cannon Fenske Routine’<br />

REF 10T6071 Viscometer holder ‘Cannon Fenske Reversed Flow’<br />

REF 10T6321 Viscometer holder ‘Utube (Ostwald) Routine’<br />

REF 10T6051 Viscometer holder ‘Utube (Ostwald) Reversed Flow’<br />

REF 10T6040 Viscometer holder ‘Pinkevitch transparent 269mm<br />

REF 10T6050 Viscometer holder ‘Pinkevitch transparent long’<br />

REF 10T6090 8 Channel Stop-watch<br />

REF 00T0239 ASTM Thermometer holder<br />

REF 00T0220 <strong>Tamson</strong> mineral oil 20ltrs<br />

(80..150°C/176..302°F)<br />

REF 08T0001 Silicon 200-10 cSt 20ltrs Transparent<br />

(20..150°C/ 68..302°F)<br />

REF 00T0050 TLC10-3 external cooler to work below ambient temperature<br />

Viscometer/glass capillaries, see special section ‘Viscometers’<br />

ASTM Thermometers, see special section ‘ASTM Thermometers’<br />

Viscosity Reference oil, see special section ‘Viscosity Calibration Standards’<br />

MAIN SPARE PARTS 230V/50-60Hz (115V/60Hz ON REQUEST)<br />

REF 06T0500 Microprocessor board TMC70<br />

REF 06T0514 Print Power board TMC70<br />

REF 24T0028 Power supply 500 W<br />

REF 25T2310 PT-100 sensor<br />

REF 25T0340 Heater 780 W<br />

REF 25T0351 Heater 500 W<br />

REF 06T0507 Print TMC70 display<br />

REF 28T4125 Net entry plus filter 10A<br />

REF 25T1343 Capacitor 2 uF<br />

REF 25T1243 Cooling fan<br />

REF 24T8581 Safety cut-out thermostat<br />

<strong>Tamson</strong> Instruments B.V. T. + 31 10 522 43 73 VAT: NL 80 66 34 984 B01<br />

Van ’t Hoffstraat 12 F. + 31 10 521 19 41 Rabobank: 16 01 00 046<br />

2665 JL BLEISWIJK www.tamson.com Chamber of Commerce: 271 69 541<br />

The Netherlands<br />

sales@tamson.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!