13.05.2014 Views

ODISHA TOURISM DEVELOPMENT CORPORATION LIMITED (A ...

ODISHA TOURISM DEVELOPMENT CORPORATION LIMITED (A ...

ODISHA TOURISM DEVELOPMENT CORPORATION LIMITED (A ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1<br />

<strong>ODISHA</strong> <strong>TOURISM</strong> <strong>DEVELOPMENT</strong> <strong>CORPORATION</strong> <strong>LIMITED</strong><br />

(A Govt. of Orissa Undertaking)<br />

Panthanivas (Old Block): Lewis Road: Bhubaneswar-14<br />

(BUILDING PROJECT DIVISION-I)<br />

DETAILED TENDER CALL NOTICE<br />

With Tender Schedule<br />

PERCENTAGE RATE TENDER<br />

Name of Work: Construction of Tourist Reception Centre at Saunleipitha in Ganjam<br />

District. under Destination Development Scheme.


2<br />

<strong>ODISHA</strong> <strong>TOURISM</strong> <strong>DEVELOPMENT</strong> <strong>CORPORATION</strong> <strong>LIMITED</strong><br />

(A Government of Orissa Undertaking)<br />

BUILDING PROJECT DIVISION-I<br />

Sl.<br />

No.<br />

Detailed Tender Call Notice<br />

Sealed tenders in conformity with DTCN eventually to be drawn in P.W.D. form F-2<br />

are invited in prescribed form from registered contractors of state<br />

PWD/Irrigation/CPWD/MES/Railway and other Government organizations for the<br />

following works<br />

Name of work<br />

Estimate cost<br />

(Rs in lakhs.)<br />

Cost of<br />

Tender<br />

paper<br />

( Nonrefunda<br />

ble)<br />

EMD<br />

( 1%<br />

estimated<br />

cost)<br />

Class of<br />

Contract<br />

or<br />

Period of<br />

completion<br />

1 2 3 4 5 6 7<br />

1. Construction of Tourist<br />

Reception Centre at<br />

Saunleipitha in Ganjam<br />

District.<br />

under<br />

Destination Development<br />

Scheme.<br />

Rs49,79,000.00<br />

Rs6000+<br />

4%VAT.<br />

Rs.49,790.00 “B‘’ & “A” 6(Six)<br />

Calendar<br />

Months.<br />

The details of tender documents can be had from our Web site:<br />

www.panthanivas.com. The Tender paper will be received up to 3 P.M of 31.05.2012 at<br />

O.T.D.C. Head office by speed post/registered post only and will be opened on the same day<br />

at 4.00 P.M. O.T.D.C. Ltd will not be held responsible for postal delay.<br />

The Authority reserves the right to reject any or all the tenders without assigning<br />

any reason thereof.<br />

CONTRACTOR<br />

2<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


3<br />

TERMS & CONDITIONS<br />

1. Eligibility criteria:<br />

The tender documents should contain the following requirements without<br />

which the tender shall be liable for rejection .<br />

a) The cost of Tender paper (at col-4 above) in shape of Bank Draft in favour of<br />

the Managing Director, O.T.D.C. Ltd payable at any nationalized bank,<br />

Bhubaneswar. .<br />

b) EMD 1% (one percent) of estimated cost put to tender(at col-5 above) in<br />

shape of P.O.S.B. /P.O.T.D. /N.S.C. /K.V.P. /Deposit Receipt of schedule Bank<br />

etc. duly pledged in favour of Managing Director OTDC Ltd. Bhubaneswar/<br />

Bank Draft in favour of the Managing Director, O.T.D.C. Ltd payable at any<br />

Nationalized bank, Bhubaneswar .<br />

c) Attested copies of valid contractor registration License<br />

d) Attested copies of VAT Clearance Certificate/ TIN No<br />

e) Attested copies of Up to date PAN CARD<br />

f) Attested copies of E.P.F. Registration Certificate.<br />

2. The tender should be sealed with wax properly with own seal.<br />

3. The sealed envelope containing the tender should be super scribed with the<br />

name of the work and should be addressed to the Sr.Divisional Manager<br />

(B.P.-I),OTDC Ltd. Bhubaneswar.<br />

4. PENALTY CLAUSE:<br />

Penalty @ 1% of the agreement value per month (30days) computed on perday<br />

basis shall be imposed for delay from the stipulated date of completion.<br />

5. Percentage Rate Tender :<br />

The tender will be on percentage rate over the estimated cost and not on item rate<br />

basis as per works department letter no codes-5/07-17190 dt.09.10.07. The<br />

percentage rate over the estimated cost should be quoted both in words and<br />

figures. In case of discrepancy between words and figures, the words shall prevail.<br />

6 (a) The Plan and Specification for the work can be seen at the Office of the<br />

Sr. Divisional Manager (BP)-I, O.T.D.C.Ltd, during working hours and days.<br />

Complaints at a future date that the plan and specification have not been seen, will<br />

not be entertained.<br />

(b) All other information can be had from the Sr.Divisional Manager (BP)-I,<br />

O.T.D.C. ltd.<br />

7 Additional performance security shall be deposited by the bidders when the<br />

bid amount is seriously unbalanced i.e. less than the estimated cost by more<br />

than 10%. In such an event, the bidder will deposit the additional<br />

performance security to the extent of the differential cost of the bid amount<br />

and 90% of the estimated cost in shape of post office savings bank<br />

Account/National Savings Certificate/Post Office Time Deposit Account/<br />

Kissan Vikash Patra/ Deposit receipt of schedule Bank at the time of<br />

execution of agreement. Failing on which the tender is liable for rejection.<br />

8 The Managing Director, O.T.D.C. Ltd. reserves the right to reject any or all<br />

tenders received without assigning any reason thereof.<br />

CONTRACTOR<br />

3<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


4<br />

9 EARNEST MONEY DEPOSIT AND INITIAL SECURITY DEPOSIT<br />

The tenderers whose tender is selected for acceptance shall within a period of<br />

seven days upon written intimation being given to him of acceptance of his tender<br />

make an initial security deposit of 1% (one percent) of the tendered amount as<br />

shown in clause.3 above so that the earnest money and initial security deposit will<br />

be 2% of the tendered amount and sign the agreement in the Office of<br />

O.T.D.C.Ltd, failing which, the tender will be rejected with forfeiture of E.M.D.<br />

This security deposit, together with the earnest money and the amount withheld if<br />

any shall be retained as security deposit for the due fulfillment of this contract.<br />

Failure to enter into the required agreement and to make the security deposit, as<br />

above shall entail forfeiture of the Earnest Money. No tender shall be finally<br />

accepted until the required amount of security deposit (money) is deposited. The<br />

written agreement to be entered into between the contractor and the Corporation<br />

shall be the foundation of the right of both the parties and the contract shall<br />

deem to be incomplete until the agreement has first been signed by the contractor<br />

and then by the Sr.Divisional Manager (BP)-I, O.T.D.C.Ltd.<br />

10 The contractors will be responsible for payment of all royalties or other charges<br />

for quarrying materials. All local taxes inclusive of State Sales Tax and Income<br />

Tax, Octroi charges, Ferry and Tollage charges are to be paid by the Contractor.<br />

11 I.T.C.C/PAN and S.T.C.C./VATCC :<br />

The tender may not, at the discretion of the competent authority, be considered<br />

unless accompanied with attested true copy of the PAN card and VAT clearance<br />

certificate as the case may be and the original certificate to be produced at the<br />

time of opening of tenders.<br />

12 If the contractor removes any materials or stock so supplied to him from the site<br />

of work with a view to disposing off the same dishonestly, he should in addition to<br />

any other liabilities Civil or Criminal arising out of the contract be liable to pay a<br />

penalty equivalent to five times the price of the materials on stock according to<br />

the stipulated rates and the penalty so imposed shall be recovered from any sum<br />

that may then or at any time thereafter become due to the contractor or from his<br />

security.<br />

13 The contractor should be fully liable to indemnify the Corporation for payment of<br />

any compensation under Workmen's Compensation Act-V-III of 1923 on account<br />

of the workmen being employed by him and the full amount of compensation paid<br />

will be recovered from the contractor.<br />

14 Every tenderer must examine the detailed specification of Orissa before<br />

submitting his tender. The right is reserved without impairing the contract to<br />

make such increase or decrease in the quantities or items of work mentioned in<br />

the schedule attached to the tender notice as may be considered necessary to<br />

complete the work fully and satisfactorily. Such increase shall in no case<br />

invalidate the contract rates. It shall be definitely understood that the<br />

Corporation does not accept any responsibility for the correctness or<br />

completeness of the quantities shown in the schedule. The schedule is liable to<br />

alteration by omissions or additions or deductions and such omissions/ deductions<br />

CONTRACTOR<br />

4<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


5<br />

shall in no case invalidate the contract and no extra monetary compensation will be<br />

entertained.<br />

15 Engineer contractors desirous to avail the facility of exemption of EMD are<br />

required to submit affidavit to the effect that he/she has not yet availed this<br />

facility for more than two works during the current financial year. The name of<br />

work for which and the authority to whom the tenders have been submitted, must<br />

be mentioned in the affidavit failing which the tender will be rejected. Exemption<br />

of EMD will be entered in the original Registration Certificate of the Engineer<br />

Contractor at the time of participating in the tender. Hence the Engineer<br />

Contractor or his authorized representative has to produce the original license for<br />

necessary entry within 2 days of opening of the tender.<br />

16 The agency should produce work experience of the similar nature of the work and<br />

produce the certificate regarding completion of similar works during the last five<br />

financial years.<br />

17 The agency should use all building materials such as reinforcement, sand etc. free<br />

from corrosion/corrosive materials etc. No extra payment will be made for such<br />

purpose by O.T.D.C. Ltd.<br />

18 Orissa Detailed Standard Specification will be followed during execution of work.<br />

19 All materials including those issued direct to the work will be received by the<br />

contractor from the respective Store of the Corporation in the sizes as per<br />

availability of stock. After issue, it will be the contractor's responsibility for<br />

transportation, storage, handling, safe custody and proper upkeepment of<br />

materials. The rate of the contractor should include all the incidental charges<br />

required after the issue of material from Corporation store till its utilisation in<br />

the work and return of surplus and good materials at the issuing store.<br />

The contractor will have to bear the cost of straightening, cutting, jointing,<br />

welding etc. of all steel reinforcement and structural and no cut pieces less than<br />

1(one) meter length will be accepted. After completion of the work the contractor<br />

has to return all surplus and good materials at the issuing store at his own cost<br />

failing which the cost of the unutilized balance Corporation materials and such<br />

other damaged materials not receptacle to the Corporation would be recovered<br />

from him at 5 (five) times the stock issue rates.<br />

20 All reinforced cement concrete work should conform to Orissa Detailed Standard<br />

Specification and should be of grade M-150/200 with 12mm. Size black hard<br />

crusher broken granite stone chips (20mm. Size not to exceed 25%) having a<br />

minimum compressive strength (in work test) 150kg/200kg/cm 2 in 15 cm. cubes at<br />

28 days after mixing and tests conducted in accordance with IS 456 and IS 516.<br />

21 Shuttering and centering shall be with seasoned Sal wood planks the inside of<br />

which shall be lined with suitable sheeting and made leak-proof and water tight or<br />

alternatively steel shuttering and centering may be used.<br />

22 The selected contractor may take delivery of supply of materials according to his<br />

need for the work issued by the Engineer-in-charge of the work. The contractor<br />

shall make all arrangements for proper storage of materials. But no cost for<br />

raising shed for the storage of materials and pay of watchmen etc. will be borne<br />

by the Corporation. These are all to be borne by the Contractor. The Corporation<br />

CONTRACTOR<br />

5<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


6<br />

is not responsible for considering the theft of materials at site. It is<br />

contractor's risk. Under any such plea if the contractor stops the work he shall<br />

have to pay the penalty as per the clauses of the contract.<br />

23 For the purpose of jurisdiction in the event of dispute if any contract should be<br />

deemed to have entered into within the State of Orissa and it is agreed that,<br />

neither party to the contract nor the agreement will be competent to bring a suit<br />

in regard to the matters covered by this contract at any place outside the State<br />

of Orissa.<br />

24 After the work is finished, all surplus materials and debris are to be removed by<br />

the contractor and preliminary works such as vats, mixing platforms, etc. are to be<br />

dismantled and all the materials are to be removed from the site. No extra<br />

payment will be made to the contractor on this account. The rate quoted should<br />

be inclusive of all these items. The ground upto 15 meter shall be cleared and<br />

rough dressed.<br />

25 The contractor shall not interfere with the execution of water supply or electrical<br />

fittings arrangements and any other works entrusted to any other agency by the<br />

Corporation at any time during the progress of work.<br />

26 The Corporation will have the right to inspect the scaffolding and centering made<br />

for the work and can reject partly or fully such structures if found defective in<br />

their opinion.<br />

27 The Contractor will have to arrange for water supply for all works and made<br />

sanitary arrangements at his own cost for his Labour camps. The contractor has<br />

to arrange adequate lighting arrangements for night works whenever necessary at<br />

his own cost.<br />

28 Bailing out water from the foundation either rain water or sub-soil water if<br />

necessary should be borne by the contractor. No payment will be made for<br />

benchmarks, level pillars profiles and benching and leveling ground where required.<br />

The rates quoted should be for finished items of work inclusive of these incidental<br />

items of work.<br />

29 All the quantities mentioned in the schedule are combined for ground floor and<br />

multi-floors in case of multistoried building and the rates should be through for<br />

the same.<br />

30 Cement concrete in roof slabs, beams and wherever prescribed by the Engineer-incharge<br />

shall be machine mixed and vibrated, and the contractor should arrange his<br />

own concrete mixers, vibrators, and pumps etc. for the purpose.<br />

31 It should be understood clearly that no claims whatsoever will be entertained.<br />

32 The tenderer shall have to abide by the C.P.W. Safety Code introduced by the<br />

Govt. of India, Ministry of Works, Housing and Supply in their standing orders<br />

No.44250 dt.25.11.57.<br />

33 The contractor will abide by the Fair Wages clause as introduced by the<br />

Government.<br />

34 The Corporation have the right to supply at any time in the interest of work any<br />

Corporation materials to be used in the work in addition to those mentioned in the<br />

clause 13 and the contractor shall use such materials without any controversy or<br />

CONTRACTOR<br />

6<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


7<br />

dispute on that account. The rates of the materials will be at the stock issue<br />

rates fixed by the Corporation or market rates whichever is higher.<br />

35 The contractor will be responsible for the loss or damage if any of Corporation<br />

materials supplied to him under clauses 13 and 30 during execution of the work<br />

due to reasons whatsoever and the cost of such materials will be recovered from<br />

him at the prevailing stock issue rates or market rates whichever is higher.<br />

36 CONTRACTOR'S TOOLS & PLANT AND SUPPLY OF DEPARTMENTAL TOOLS &<br />

PLAT TO CONTRACTORS.<br />

The contractor should arrange at his own cost necessary tools and plant such as<br />

Pumps, Vibrator, Concrete mixer etc. required for the efficient execution of the<br />

work and rates quoted should be inclusive of the running charges of such plant and<br />

cost of consumables.<br />

37 The contractor will have to submit to the Sr.Divisional Manager (BP)-I, O.T.D.C.<br />

Ltd. monthly return of labour both skilled & un-skilled employed by him on the<br />

work.<br />

38 The tenderers are required to go through each clause of Corporation contract<br />

form carefully in addition to clauses mentioned herewith before tendering.<br />

39 No part of the contract shall be sublet without written permission of the<br />

Sr.Divisional Manager (BP)-I O.T.D.C.Ltd., Bhubaneswar or transfer be made by<br />

power of attorney authorising others to receive payment on the contractor's<br />

behalf.<br />

40 No tender documents will be sold to the intending, tenderers after the last date<br />

stipulated for selling of Tender papers.<br />

41 If any further necessary information is required, Sr.Divisional Manager (BP)-I,<br />

O.T.D.C. Ltd., Bhubaneswar will furnish such but it must be clearly understood that<br />

tenders must be received in order and according to the instructions.<br />

42 Bags and weight of one cubic metre of cement being taken, as 14.42 quintals.<br />

43 In the event of any delay in the supply of Departmental materials or supply of<br />

detailed structural designs for unavoidable reasons, reasonable extension of time<br />

will be granted on the application of the contractor. But no claim for monetary<br />

compensation will be entertained under any circumstances.<br />

44 No contractors will be permitted to furnish their tender in their own manuscript<br />

papers.<br />

45 SAMPLE OF MATERIALS:<br />

Every tenderer is expected before quoting his rates to inspect the site of<br />

proposed work. He should also inspect the quarries and satisfy himself about the<br />

quality, availability of materials, medical aids, labour and foodstuffs etc. and the<br />

rates may be inclusive of all these items of work. In every case the materials must<br />

comply with the relevant specification and samples of materials in sealed bag may<br />

be submitted along with the tender for approval of the Sr.Divisional Manager (BP),<br />

O.T.D.C.Ltd.<br />

46 O.T.D.C.Ltd. Will not however, after acceptance of contract rate, pay any extra<br />

charges for lead or for any other reason in case the contractor is found later on<br />

to have mis-judged the materials available.<br />

CONTRACTOR<br />

7<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


8<br />

47 All fittings for doors and windows if supplied by the Contractor should be of best<br />

quality and should be got approved by the Engineer-in-charge before they are used<br />

on the work<br />

48 EXTRANEOUS CONDITION:<br />

The tenders containing extraneous conditions not covered by the tender call notice<br />

are liable for rejection.<br />

49 VALIDITY<br />

All tenders received will remain valid for a period of ninety days from the date of<br />

receipt of tenders and validity of tender can also be extended if agreed to by the<br />

contractor and the Corporation.<br />

50 After completion of the work the contractor shall arrange at his own cost all<br />

requisite equipments for testing building if found necessary and bear the entire<br />

cost of such test.<br />

51 LIST OF WORKS IN HAND, T & P & WORK EXECUTED:<br />

Tenderers are required to submit, (i) list of works in the hand in the following<br />

prescribed proforma 'A', (ii) list of works executed in the prescribed proforma 'B'<br />

and (iii) the list of T & P in the prescribed proforma 'C' along with the tenders.<br />

52 Letters etc. found in the tender box, raising or lowering rates or dealing with any<br />

point in connection with the tender will not be considered.<br />

53 All reinforced cement concrete works should be finished smooth, Extra charges<br />

for plastering if required to any R.C.C. structures like columns, beams, chajjas etc.<br />

shall not be paid.<br />

54 2% of the gross amount of bill will be deducted towards income tax from the<br />

contractor’s bill. Also 4% of the gross amount of the bill will be deducted towards<br />

Sales Tax for all contracts costing Rs.1.00 lakh & more. This will vary as per<br />

prevailing Govt. orders from time to time.<br />

55 1% of the gross amount of bill will be deducted towards CESS from the<br />

contractor’s bill under the Building and other construction worker’s(RE&CS)<br />

Act 1996 vide Lt. NO: 12653 dated 15 th December,2008 of labour<br />

&Employment Dept. Govt. of Orissa.<br />

PROFORMA-'C'<br />

CERTIFICATE OF TOOLS AND PLANTS<br />

I/We hereby certify that the following tools and plants, machineries and vehicles<br />

are in my/our possession in working orders.<br />

i.<br />

ii.<br />

iii.<br />

iv.<br />

v.<br />

I/We also note that, non-submission of this certificate will render my/our tender<br />

liable for rejection.<br />

CONTRACTOR<br />

8<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


9<br />

Signature of the tenderer<br />

Date_______________<br />

56 The tenderer shall bear cost of various incidental sundries and contingencies<br />

necessitated by the works falling within the following or similar category.<br />

(a) Rent, royalties and other charges of materials, Octroi duty, all other taxes<br />

including sales tax, ferry tolls, conveyance charges and other costs on<br />

account of land and buildings including temporary buildings required by the<br />

tenderer for collection of materials, storage, housing of staff or other<br />

purpose of the work. No rent however be payable to Corporation for<br />

temporary occupation of land owned by the Corporation at the site of the<br />

work.<br />

(b) Labour camps and huts necessary to a suitable scale including conservancy<br />

and sanitary arrangements thereon to the satisfaction of the local health<br />

authorities.<br />

(c) Suitable water supply including pipe water supply wherever available for the<br />

staff and labourers for the works.<br />

(d) Fees and dues hired by Municipal, Canal and water supply authorities.<br />

(e) Suitable equipments and wearing apparatus for the labourers engaged in<br />

risky operation.<br />

(f) Suitable fencing barriers, signal including paraffin and electrical signal<br />

where necessary at works and approaches in order to protect the public and<br />

employees from accidents.<br />

(g) Compensation including cost of any suit for injury to person or property due<br />

to neglect of any major precautions also sums which may become payable<br />

due to operation of workmen's Compensation Act.<br />

(h) The contractor has to arrange adequate lighting arrangement for night<br />

works wherever necessary at his own cost.<br />

(i) The contractor has to arrange all the building materials including the<br />

equipments required for under reamed pile foundation for starting the work.<br />

57 INTEREST:<br />

Under no circumstances interest is chargeable for the dues or additional dues if<br />

any payable for the work.<br />

58 Special class contractor shall employ under him one Graduate Engineer and two<br />

Diploma Holders belonging to the State of Orissa, like wise 'A' class contractor<br />

shall employ under him one Graduate Engineer or two Diploma Holder belonging to<br />

the State of Orissa. The employment of such Graduate Engineer and Diploma<br />

Holders under the contractor shall be full-time and continuous and they shall not<br />

be superannuated, retired, dismissed or removed personnel from any state Govt.<br />

or Central Govt. service/Public Sector undertaking/Private companies and firms or<br />

be ineligible for appointment to Govt. service. The contractor shall pay them<br />

monthly emoluments, which shall not be less than the emoluments of the personnel<br />

of equivalent qualification employed under the State Govt. of Orissa. The<br />

Sr.Divisional Manager, Building Project may however, assist the contractor with<br />

names of such un-employed Graduate Engineers and Diploma Holders if such help is<br />

sought for by the Contractor.<br />

CONTRACTOR<br />

9<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


10<br />

59 The name of such Engineer personnel appointed by the Contractor should be<br />

intimated to the tender receiving authority along with each tender, as to who would<br />

be supervising the work.<br />

60 Each bill of the Special Class or 'A' class contractor shall be accompanied by an<br />

Employment Roll of the Engineering personnel together with a certificate of the<br />

Graduate Engineer or Diploma Holder so employed by the contractor to the effect<br />

that the work executed as per the bill has been supervised by him. A prescribed<br />

proforma is enclosed herewith for furnishing the required certificate there in<br />

under this clause.<br />

61. He sealed cover should be super-scribed with the material of contents.<br />

62 His quantity/volume of item may alter during construction as per field condition.<br />

63. Wherever there is ambiguity or missing data, the work shall be done as per the<br />

direction of the Engineer-in-charge.<br />

64. The colour of the pole should match with that of the luminary.<br />

65. The interested bidders may visit the site and should be acquainted themselves with<br />

the field activities to be experienced during construction.<br />

66. The delay if any due to other departments such as digging on road etc. shall be the<br />

responsibility of the successful bidder.<br />

67. Separate sheets may be attached if the space is not sufficient in the tender paper.<br />

68 The bidder shall possess electrical license from ELBO, Orissa.<br />

69 Statutory clearance if any from electrical inspector shall be the responsibility of<br />

the successful bidder.<br />

70 Wherever the items appear with a sign (/) both rates shall be quoted.<br />

71 The Contractor shall have to furnish an affidavit about the authentication of<br />

tender documents including bank guarantee at the time of submission of Tender<br />

paper.<br />

Total 71 (seventy One) clauses only.<br />

Sr. Divisional Manager<br />

(Building Project)-I<br />

O.T.D.C. Ltd.<br />

CONTRACTOR<br />

10<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


QUALITY CONTROL REQUIREMENTS<br />

1.0 Earth work<br />

1.1. Density requirements for embankments and sub-grade materials. MoRTH<br />

Specification (4 th Revision).<br />

Sl.<br />

No.<br />

Type of work<br />

11<br />

Maximum dry density at<br />

OMC (IS:2720 Part-8)<br />

1. Embankment upto 3m height not subjected to<br />

extensive flooding<br />

2. Embankment exceeding 3m height or embankment<br />

subjected or embankment subjected to long periods<br />

of inundation.<br />

Minimum 15.2kN/m 3<br />

Minimum 16kN/m 3<br />

3. Subgrade and earthen shoulder and back fill. Minimum 17.5kN/m 3<br />

1.2. Compaction requirement for embankment and sub-grade.<br />

Sl.<br />

No.<br />

Type of work<br />

Percentage of<br />

Compaction at OMC<br />

1. Sub-grade and shoulder Minimum 97%<br />

2. Embankment Minimum 95%<br />

3. Expansive clay<br />

a. Sub-grade Not allowed<br />

b. Remaining portion Minimum 90%<br />

1.3. Criteria for small embankment (dams) (IS : 12169)<br />

The general guidelines for embankment sections are furnished in Table No.-1.<br />

TABLE-4<br />

(GENERAL GUIDELINES FOR EMBANKMENT SECTIONS)<br />

SL.<br />

NO.<br />

DESCRIPTION<br />

HEIGHT UPTO<br />

5m<br />

1. Type of section Homogeneous<br />

Modified<br />

homogeneous<br />

section<br />

Ii Slopes U/S U/S<br />

a. Coarse grained soil<br />

(GW, GP, SW, SP)<br />

(H:V)<br />

(H:V)<br />

HT. ABOVE 5M<br />

AND UPTO 10m<br />

Zoned section/<br />

Modified<br />

homogeneous<br />

section/<br />

homogeneous<br />

section<br />

U/S<br />

(H:V)<br />

D/S<br />

(H:V)<br />

HT. ABOVE 10M AND<br />

UPTO 15m<br />

Zoned section/ modified<br />

homogeneous section/<br />

homogenous section<br />

U/S<br />

D/S<br />

Not suitable Not suitable Not suitable for core.<br />

Suitable for casing zone.<br />

CONTRACTOR<br />

11<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


. Coarse grained soil<br />

(GW,GP, SW, SP)<br />

c. Fine grained soil (Cl,<br />

ML, Cl, Ml)<br />

d. Fine grained Soil<br />

(CH, MH)<br />

12<br />

2:1 2:1 2:1 2:1 Section to be decided<br />

based upon the stability<br />

analysis in accordance with<br />

IS: 7894-1975.<br />

2:1 2:1 25:1 2251:1 -do-<br />

2:1 2:1 3.75:1 25:1 may<br />

be provided<br />

a. Top width -- 3m 3m<br />

Necessary<br />

b. Top level -- 0.5m above MWL 0.5m above MWL<br />

Iv Rock toe height Not necessary<br />

upto 3m above<br />

3m ht, 1m, ht of<br />

rock toe may be<br />

provided<br />

Necessary H/5,<br />

where H is the<br />

height of the<br />

embankment.<br />

Necessary H/5, where H is<br />

the height of the embkt.<br />

v. Berms Not necessary Not necessary The berm may be provided<br />

as per design. The min.<br />

berm width shall be 3m.<br />

The berm may be provided<br />

also on the D/S slope for<br />

facilities<br />

during<br />

maintenance.<br />

1.4. Criteria for small embankments (dams) : (IS : 12169)<br />

The general guidelines regarding suitability of soil for construction of dams are<br />

furnished in table No. 2.<br />

Relative<br />

suitability<br />

Table – 2<br />

Suitability of soil for construction of dams.<br />

Homogeneous<br />

Dykes<br />

Zone dam<br />

Impervious cure<br />

Pervisou casing<br />

Very GC GC SW,GW GC<br />

Suitable<br />

Suitable CL, Cl Cl, Cl GM CL,Cl<br />

Impervious<br />

blanket<br />

Fairly suitable SP, SM, CH GM, GC, SM, SC, CH SP, GP CH, SM, SC, GC<br />

Poor<br />

Not suitable<br />

Ml, Ml, MH<br />

OLOl, OH, Pt<br />

1.5. Frequency of test<br />

Table-3<br />

Sl. Test Designation Frequency of test as Frequency of test of ODR & VR<br />

CONTRACTOR<br />

12<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


13<br />

No. per MoRTH as recommended by IRC-SP-20<br />

1. Mechanical analysis of<br />

soil<br />

2 tests/3000m 3<br />

2. Plastic of soil 2 tests/3000m 3<br />

3. Density test of soil 2 tests/3000m 3<br />

4. Deleterious content As & when required<br />

5. Moisture content of<br />

soil<br />

6. CBR test of soil 1 tests/3000m 3 or<br />

more<br />

7. Compaction test of soil<br />

for each layer<br />

1 tests/250m 3 2-3 tests per 250m 3 of loose soil<br />

5-10 tests/1000m 3 5-10 tests per 1000m 3<br />

Note : CBR of sub-grade should not be less than 2%<br />

MoRTH- Ministry of road transport and highways<br />

Table-7<br />

E.W. COMPACTION : The information given should be taken only as an approximate<br />

guide<br />

Materi<br />

al<br />

Major<br />

Division<br />

Sub-groups<br />

Suitable<br />

type of<br />

compacting<br />

equipment<br />

No. of<br />

passes<br />

for<br />

satisfact<br />

ory<br />

compactio<br />

n (Min.)<br />

Thicknes<br />

s of<br />

loose<br />

layer<br />

(Actual<br />

thicknes<br />

s<br />

depends<br />

on plant<br />

used),<br />

Max cm.<br />

Remarks<br />

1 2 3 4 5 6 7<br />

Coarse<br />

grained<br />

soil and<br />

other<br />

materia<br />

ls<br />

Gravel and<br />

gravelly soils<br />

Well-graded<br />

gravel, gravels<br />

and mixtures,<br />

little or no<br />

fines<br />

Well-graded<br />

gravel sand<br />

mixtures with<br />

excellent clay<br />

blinder<br />

uniform gravel<br />

with little or<br />

no fines poorly<br />

graded gravel<br />

Smoothwheel<br />

roller<br />

pneumatictyred<br />

roller<br />

vibrating<br />

smooth<br />

wheel<br />

roller<br />

heavy<br />

bivrating<br />

plate frogrammer<br />

6<br />

6<br />

6<br />

2*<br />

3**<br />

20<br />

20<br />

20<br />

37.5<br />

37.5<br />

20<br />

Vibrating rollers<br />

or vibrators will<br />

be very<br />

satisfactory if<br />

the moisture<br />

conent of the soil<br />

is low, but may be<br />

uneconomical<br />

close moisture<br />

content control is<br />

essential when<br />

the moisture<br />

content is<br />

relatively high it<br />

CONTRACTOR<br />

13<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


Fine<br />

grained<br />

soils<br />

CONTRACTOR<br />

Soils having<br />

low<br />

compressibili<br />

ty<br />

Soils having<br />

high<br />

compressibili<br />

ty<br />

Fibrous<br />

organic soils<br />

and gravel sand<br />

mixtures little<br />

or no fines<br />

Gravel with<br />

fines. Silty<br />

gravel, clayey<br />

gravel, poorlygraded<br />

gravelsand-clay<br />

mixtures<br />

Well grained<br />

sands and<br />

gravelly sands,<br />

little or no<br />

fines<br />

Uniform sands<br />

with little or<br />

no fines silts<br />

(inorganic) and<br />

very fine<br />

sands, rock<br />

flour, silty or<br />

clayey fine<br />

sands, with<br />

slight<br />

plasticity. Silty<br />

and sandy clays<br />

(inorganic or<br />

medium<br />

plasticity.<br />

Clays<br />

(inorganic) or<br />

medium<br />

plasticity.<br />

Micaceous or<br />

distomaccous<br />

fine sandy and<br />

silty soils,<br />

elastic silts<br />

14<br />

Well-graded<br />

sand with<br />

excellent claybinder<br />

powerrammer<br />

Smooth<br />

wheel<br />

roller<br />

pneumatic<br />

tyred<br />

roller<br />

track<br />

laying<br />

tractor<br />

sheep foot<br />

roller frog<br />

rammer<br />

power<br />

rammer.<br />

14<br />

4<br />

--<br />

10<br />

30<br />

2*<br />

2*<br />

20<br />

Sr.DIVISIONAL MANAGER (B.P.)-I<br />

--<br />

15<br />

15<br />

37.5<br />

20<br />

is preferably to<br />

use a pneumatic<br />

tyred roller<br />

--<br />

--<br />

These soils are<br />

considered very<br />

undesirable for<br />

use in earthwork<br />

and should not be<br />

employed if they<br />

are highly<br />

compressible it is<br />

advisable to<br />

compact these<br />

soils at the<br />

moisture content<br />

at which no<br />

change will occur<br />

subsequently<br />

As for micaceious<br />

or distomaceous<br />

fine sandy and<br />

silty soils these


15<br />

with very<br />

high<br />

compressibili<br />

ty<br />

Clays<br />

(inorganic) or<br />

high plasticity,<br />

fat clays<br />

soils are entirely<br />

unsuitable for<br />

earthwork<br />

construction.<br />

Organic clays<br />

of high<br />

plasticity pest<br />

and other<br />

highly organic<br />

swamp soils.<br />

5. Materials for cement concrete :<br />

This includes the I.S. specification of the materials such as cement, coarse and fine<br />

aggregate, water, and reinforcement. For details respective I.S. specification may be<br />

referred to.<br />

5.1. Fine aggregate : IS 383<br />

5.1.1. Zoning: The fine aggregates suitable for concrete shall be in zone-I, II or III.<br />

Fine aggregate in zone-IV are not suitable for concrete. The zone can be<br />

decided by grain size analysis by sieving as follows.<br />

Table-21 (IS-383-Table No.-4)<br />

IS Sieve<br />

Designation<br />

Grading Zone-<br />

I<br />

Percentage passing for<br />

Grading Zone-<br />

II<br />

Grading Zone-<br />

III<br />

Grading Zone-<br />

IV<br />

10m. 100 100 100 100<br />

4.75mm 90-100 90-100 90-100 95-100<br />

2.36mm 60-95 75-100 85-100 95-100<br />

1.18mm 30-70 55-90 75-100 90-100<br />

600 micron 15-34 35-59 60-79 80-100<br />

300 micron 5-20 8-30 12-40 15-50<br />

150 micron 0-10 0-10 0-10 0-15<br />

5.1.2. Bulkage :- Maximum buklage shall be limited to 20%<br />

5.2. Quality of coarse aggregates:<br />

5.2.1. Crushing value Permissible Value Method of test<br />

a. All concrete woks<br />

except wearing surface.<br />

Maximum 45% IS 2386-1963 part –<br />

IV<br />

b For wearing surface -do- 30% -do-<br />

5.2.2. Impact value Permissible Limit Method of test<br />

a. All concrete woks Maximum 45% IS 2386-1963 part –<br />

CONTRACTOR<br />

15<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


16<br />

except wearing surface.<br />

IV<br />

b For wearing surface -do- 30% -do-<br />

5.2.3. Abrasion value<br />

a. All concrete woks<br />

except wearing surface.<br />

Maximum 50% -do-<br />

b For wearing surface -do- 30% -do-<br />

5.2.4. Deleterious materials : Maximum percentage shall be 5%.<br />

5.2.5. Alkali aggregate reaction:- It is harmful for concrete. The test shall be conducted<br />

and use of pozzolanic cement or pozzolanic admixture shall be studied.<br />

5.2.6. Gradation of coarse aggregate of nominal size:<br />

Table-22<br />

IS Sieve (mm)<br />

Percentage passing for graded aggregates of nominal size<br />

40 20 15 12.5<br />

80 100 -- -- --<br />

40 95-100 100 -- --<br />

20 30-70 95-100 100 100<br />

16 -- -- 90-100 --<br />

12.5 -- -- -- 90-100<br />

10 10.35 25.55 30.70 40-85<br />

4.75 0-5 0-10 0-10 0-10<br />

2.36 -- -- -- --<br />

5.3. Cement : The normal type of cement used are :<br />

1. Ordinary Portland cement 33 grade, 43 grade, 53 grade conforming to IS: 269,<br />

IS:8112 & IS:12269 respectively.<br />

2. Port land slag cement IS: 544<br />

3. Port land pozzolana cement I.S : 1489<br />

5.3.1. Standard of physical test of cement<br />

a. Initial setting time - minimum 30 minutes<br />

b. Final setting time - Maximum 10 hrs.<br />

c. Fineness - (i) 225 (m 2 /kg) for OPC & PSC<br />

(ii) 300 (m 2 /kg) for PPC<br />

d. Soundness - a. 10mm maximum (Lechat expansion)<br />

b. Maximum 0.8% in Autoclave<br />

e. Compressive Strength :<br />

Time<br />

33 grade OPC,<br />

PSC, PPC<br />

43 grade OPC 53 grade OPC<br />

CONTRACTOR<br />

16<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


17<br />

a. 72 hrs. 16MP 2 23MP 2 27MP 2<br />

b. 7 days 22MP 2 33MP 2 37MP 2<br />

c. 28 days 33MP 2 43MP 2 53MP 2<br />

5.3.2. Standards for chemical test :<br />

Table – 23<br />

Percentage by mass (Max.)<br />

Types of cement OPC PPC PSC Remarks<br />

33 43 53<br />

1. Magnesia 6 6 6 6 8<br />

2. Insoluble residue 4 2 2 x+4(100-x)<br />

100<br />

4 Where x=% of<br />

pozollana in cement<br />

3. Sulphur trioxide 2.5d 2.5d 2.5d 3 3 Where d-3% when<br />

C,A>5%<br />

4. Sulphur as sulphide -- -- -- -- 1.5<br />

5. Loss on ignition 5 5 4 5 5<br />

6. Chloride 0.5 0.05 0.05 -- -- Maximum for prestressed<br />

and long<br />

span structures<br />

5.4. Water :<br />

Normal potable water shall be used for concrete. The pH value shall be not less than 6.<br />

Permissible limits of solids – I.S. :3025.<br />

Organic - 2000mg/litre<br />

Chloride - 2000mg/litre<br />

Inorganic - 3000mg/litre<br />

Sulphate - 400 mg/litre<br />

Suspended matter - 2000mg/litre<br />

5.5. Reinforcement steel :<br />

The normal reinforcement steel bars may be mild and medium tensile steel bars or high<br />

strength deformed steel bars conforming to I.S.-432 and IS:1786 respectively. The<br />

limits of physical and chemicals properties of deformed bar.<br />

a. Mechanical properties<br />

Sl.<br />

No.<br />

Table – 24 (IS : 1786, Table No.-3)<br />

Property F 3 415 Grade F c 500 F e 550<br />

1 2 3 4 5<br />

1 0.2% proof stress/yield<br />

stress, Min, N.mm 2 415.0 500.0 550.0<br />

2. Elongation, percent, Min,<br />

on gauge length 5.56 v(A),<br />

14.5 12.0 8.0<br />

CONTRACTOR<br />

17<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


18<br />

where A is the cross<br />

sectional area of the test<br />

piece.<br />

8% more than the<br />

3. Tensile strength, Min 10%more than<br />

485.0 N/mm 2<br />

the actual 0.2%<br />

proof stress but<br />

not less than<br />

actual 0.2% proof<br />

stress but not less<br />

than 545.0 N/mm 2<br />

6% more than the<br />

actual 0.2% proof<br />

stress but not less<br />

than 585.0 N/mm 2<br />

b. Chemical properties :<br />

Constituent<br />

Table – 24 (IS : 1786)<br />

Percent, maximum<br />

F e 415 F e 500 F e 550<br />

Carbon 0.30 0.30 0.30<br />

Sulphur 0.060 0.055 0.055<br />

Phosphorous 0.060 0.055 0.050<br />

Sulphur and phosphorous 0.11 0.105 0.10<br />

c. Frequency of test (IS : 1786)<br />

One test of each type of MS rod to be used in each structure.<br />

d. Pull out test : As per IS:2770<br />

e. Bend and rebend test : IS : 1786.<br />

f. Mass and cross sectional area (IS : 1786).<br />

Nominal size (mm) Sectional area (mm 2 ) Mass per meter (kg)<br />

6 28.3 0.222<br />

8 50.3 0.395<br />

10 78.6 0.617<br />

12 113.1 0.888<br />

16 201.2 1.580<br />

20 314.3 2.47<br />

25 491.1 3.85<br />

28 616.0 4.83<br />

32 804.6 6.31<br />

5.6. Construction joints :<br />

The concreting shall be done up to construction joints, but while commencing the<br />

work on the cold joints, the aggregates shall be exposed with high pressure water jet or<br />

CONTRACTOR<br />

18<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


19<br />

any other method. It is preferable to expose the aggregates previously i.e. just after the<br />

closer of the work by wire brushing and cleaning. Cleaning may be done be by air water<br />

jetting or any other method.<br />

6. Concrete works.<br />

6.1. Grade of concrete<br />

The grade designation shall be as follows.<br />

a. Ordinary concrete M10, M15 & M20<br />

b. Standard concrete M25, M30, M35, M40, M45, M50 & M55<br />

c. High strength concrete M60, M65, M70, M75 & M80<br />

d. Concrete exposed to seawater shall be at least M20 & M30 for P.C.C. & R.C.C.<br />

respectively. The use of slag or pozzolana cement is advantageous under such<br />

conditions.<br />

6.2. Workability of concrete<br />

Table –26<br />

Placing conditions<br />

Binding concrete; shallow sections; pavements<br />

using lavers;<br />

Mass concrete; lightly reinforced sections in<br />

slabs, beams, walls, columns; floors; hand<br />

placed pavements; canal lining; strip footings.<br />

Degree of<br />

workability<br />

Slump (mm)<br />

1 2 3<br />

Heavily reinforced sections in slabs, beams,<br />

walls, columns; slipfonn work; pumped concrete<br />

Trench fill;<br />

In-situ pilling<br />

Very low<br />

Low 25-75<br />

Medium 50-100<br />

Compacting factor from<br />

0.75 to 0.8 is suggested<br />

75-10<br />

High 100-150<br />

Tremie concrete; Very high Refer IS :9103<br />

Note : For most of the placing conditions, internal vibrators (neddle vibrators) are<br />

suitable. The diameter of the needle shall be determined based on the density and spacing<br />

of reinforcement bars and thickness of sections. For tremie concrete, vibrators are not<br />

required to be used.<br />

6.3. Mild : Concrete surfaces protected against weather or aggressive conditions<br />

except those situated in coastal area.<br />

6.3.2. Moderate : Concrete surfaces sheltered from severe rain or freezing whilst wet.<br />

Concrete exposed to condensation and rain.<br />

Concrete continuously under water.<br />

Concrete in contact of buried under non-aggressive soils/ ground water.<br />

Concrete surfaces sheltered from saturated salt air in coastal area.<br />

6.3.3. Severe : Concrete surfaces exposed to severe rain, alternate wetting and drying or<br />

occasional freezing whilst wet or severe condensation. Concrete complitely<br />

immersed in sea water concrete expose to coastal environment.<br />

CONTRACTOR<br />

19<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


20<br />

6.3.4. Very severe : Concrete surfaces exposed to sea water spray, corrosive fumes or<br />

severe freezing conditions whiles wet.<br />

Concrete incontact with or buried under aggressive sub-soil/ ground water.<br />

6.3.5. Extreme : Surface of members in tidal zone.<br />

Members indirect contact with liquid / solid aggressive chemicals.<br />

Exposure a.PCC<br />

Minimum W/C grade<br />

Cement<br />

ratio<br />

Content<br />

maximum<br />

Kg/(m 3 )<br />

Mild 220 0.6 --<br />

Moderate 240 0.6 M15<br />

Severe 250 0.50 M20<br />

Very severe 260 0.45 M20<br />

Extreme 280 0.40 M25<br />

b.PCC<br />

Mild 300 0.55 M20<br />

Moderate 300 0.50 M25<br />

Severe 320 0.45 M30<br />

Very severe 340 0.45 M35<br />

Extreme 360 0.40 M40<br />

6.4. Nominal mix concrete<br />

The nominal mix concrete may be used for concrete of M20 grade and lower as per the<br />

table below:<br />

Grade of concrete<br />

Total qty. of dry<br />

aggregate for<br />

50kg of cement in<br />

kg<br />

Table – 27<br />

Proportion of fine<br />

to coarse<br />

aggregate by mass<br />

Max. qty. of<br />

water per 50kg of<br />

cement in litre<br />

M5 800 Generally 60<br />

M 7.5 625 1:2 45<br />

M10 480 -- 34<br />

M15 330 -- 32<br />

M20 250 -- 30<br />

6.5. Design Mix : Ref. IS : 10262<br />

6.6. Placing : The concrete shall be placed and compacted before initial setting time of<br />

cement.<br />

6.7. Curing : The period for moisture curing shall be minimum 10 days. It may be<br />

extended upto 28 days.<br />

6.8. Stripping time : Following stripping time may followed.<br />

Type of form work<br />

Minimum period before striking form<br />

CONTRACTOR<br />

20<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


21<br />

a. Vertical 16-25 h<br />

b. Soffit form work to slab 3 days<br />

c. Soffit form work to beam 7 days<br />

d. Props to slab<br />

(i) Spanning upto 4.5m<br />

(ii) Spanning over 4.5m<br />

7 days<br />

14 days<br />

work.<br />

6.9 Nominal cover:<br />

Cover to be provided depending on exposure condition.<br />

Exposure<br />

Cover in mm<br />

Mild 20<br />

Moderate 30<br />

Sever 45<br />

6.9. Frequency of sampling : Depending on quantity of work, number of samples are to<br />

be taken.<br />

Qty. in m 3 No. of samples<br />

1-5 1 Set<br />

6-15 2 Set<br />

16-30 3 Set<br />

31-50 4 Set<br />

51 to above 4 plus one additional<br />

set for each 50m 3 or part.<br />

(one set= 6 Nos. of samples)<br />

6.10. Concrete works :<br />

Sl.<br />

No.<br />

A. Coarse aggregate<br />

Test<br />

Table – 28<br />

1. Sieve analysis flakiness and elongation<br />

index<br />

2. Specific gravity, bulk density, moisture<br />

content and absorption.<br />

Frequency as per MoRTH<br />

One test for every 150m 3 or less<br />

-do-<br />

3. Soundness -do-<br />

4. Abrasion, impact, aggregate crushing value -do-<br />

5. Organic impurities value<br />

6. Alkali-aggregate reactivity Twice in one season<br />

7. Petro-graphic test -do-<br />

B. Fine Aggregates<br />

1. Sieve analysis One test for every 1.50m 3 of sand<br />

CONTRACTOR<br />

21<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


2. Organic impurities -do-<br />

3. Soundness -do-<br />

22<br />

4. Sp. Gravity, moisture contents and<br />

absorption<br />

C. Cement<br />

1. Fineness One test for each brand and batch of cement<br />

-do-<br />

2. Setting time -do-<br />

3. Compressive strength<br />

D. Finished concrete<br />

1. Slump test One test for each shift both at mixer and at<br />

placement site. As frequently as possible.<br />

2. Compressive strength -do-<br />

3. Cement content One test every 3 months<br />

6.12 Aceptance criteria for concrete (IS : 456-2000, clause-16):<br />

The concrete shall be deemed to comply with the strength requirements when both the<br />

following conditions are met.<br />

a. The mean strength determined from any group of four consecutive tests<br />

results shall satisfy the following conditions.<br />

(i) Mean strength :<br />

a. For M 13 grade : f a + 0.825 x established standard deviation<br />

(rounded to 0.5) N/mm 2<br />

OR<br />

Fa + 3N/mm 2 (which ever is greater).<br />

b. For M 20 grade : Mean strengthf a + 0.825 standard<br />

or above deviation (rounded to nearest 0.5) N/mm 2<br />

OR<br />

F a + 4N/mm 2 (which ever is greater).<br />

In absence of data for SD, the SD may be taken 3.5 for M 10 and M 15 grade, 4 for M 20 and<br />

M 25 grade and 5 for M 30 to M 50 grade.<br />

b. Individual test results :<br />

For M 13 grade<br />

Strength f ck – 3N/mm 2<br />

For M 20 grade or above<br />

Strength f ck – 4N/mm 2<br />

(Where f ck is the characteristic strength of concrete)<br />

7. Common Burnt clay bricks :<br />

7.1. Brick classification : (IS : 1077 & IS : 2180)<br />

Class<br />

CONTRACTOR<br />

Average compressive strength<br />

(M/mm 2 )<br />

22<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


100 100<br />

75 75<br />

35 35<br />

30 30<br />

25 25<br />

20 20<br />

17.5 17.5<br />

15 15<br />

12.5 12.5<br />

10 10<br />

7.5 7.5<br />

5 5<br />

3.5<br />

7.2. Dimension : (IS : 1077)<br />

a. Modular<br />

Length (mm) Width (mm) Height (mm)<br />

190 90 90<br />

190 90 90<br />

b. Non-modular<br />

Length (mm) Width (mm) Height (mm)<br />

230 110 70<br />

230 110 30<br />

N. B. : Tolerance for 20 bricks of modular and non-modular are 80 mm &<br />

40mm for different heights.<br />

7.3. Water absorption : (IS : 3495).<br />

After immersion in cold water for 24 hours<br />

a. Upto class 12.5 : Maximum 20%<br />

b. Higher pressure : Maximum 15%<br />

7.4. Frequency of tests :<br />

20 bricks shall be tested out of 50,000 & 1,00,000 bricks in class 100 & 75.<br />

7.5. Grading of sand for plaster (IS : 1542).<br />

IS sieve designation (mm) Percentage passing by weight<br />

10 100<br />

4.75 95.100<br />

2.236 95-100<br />

1.18 90-100<br />

600 micron 80-100<br />

300 micron 20-65<br />

150 micron 0-50<br />

23<br />

WATER SUPPLY<br />

CONTRACTOR<br />

23<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


24<br />

8. Pipes, pipe fitting valves and specials:<br />

Pipes of different types and classes, pipe fittings, valves and specials used for pipe<br />

laying work should be manufacturer and factory tested hy7drostatically as per the<br />

relevant I.S. specifications as given below. The CI and DI pipes on DGS&D contract are to<br />

be tested by the agency authorized by DGS&D/EPM and PVC pipes and fittings are to be<br />

tested by CIPET (Central Institute of Plastic Engineering and technology).<br />

8.1. Pipe<br />

8.11. Reference to I.S. code :<br />

IS : 1536<br />

Specification for centrifugally cast spun iron pressure pipe for<br />

water, gas & sewege.<br />

IS : 8329<br />

Specification for centrifugally cast (spun) ductile iron pressure pipe<br />

for water, gas & sewege.<br />

IS : 3589<br />

IS : 4985<br />

Specification for electrically welded steel pipe (first revision)<br />

Specification for electrically welded steel pipes (first revision)<br />

IS : 4958<br />

IS : 10221<br />

Un plasticised PVC pipes for potable water supplies.<br />

Code of practice for coating and wrapping under ground steel pipes.<br />

IS : 11906 Recommendation for cement master lining of cast iron milk steel and<br />

ductile Iron pipes and fitting for transport of<br />

water.<br />

8.2. Pipe fittings and jointing materials.<br />

8.2.1. Reference to code :<br />

IS : 1538 Specification for cast iron fitting for pressure pipe (para 1 to 24)<br />

for water, gas & sewge<br />

IS : 10124 Febricated PVC fitting for potable water samples(para 1 to 13)<br />

IS : 782<br />

IS : 5383<br />

Specification for caulking lead<br />

Rubber gaskets for double iron pipes.<br />

8.3. Valves and specials<br />

IS : 780<br />

IS : 2906<br />

IS : 2685<br />

IS : 5312<br />

Specification for sluice valves for water works purpose (50mm to<br />

300mm)<br />

Specification for sluice valves for water works purpose (350mm to<br />

1200mm)<br />

Code of practice for selection installation and<br />

maintenance of sluice values.<br />

Specification for swing check type reflux (Non-return<br />

valves) for water works purpose.<br />

8.3. Inspection of pipes before final acceptance.<br />

24<br />

CONTRACTOR<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


25<br />

Each pipe shall have cast, stamped or indelibly painted the trade mark of<br />

manufacturer, the nominal dia, class weight, batch number, last two digits of the year of<br />

manufacturer and also with ISI certificate mark. The pipes should bear the stamping of<br />

testing agency like DGS & D in case of CI & DI pipes CIPET in case of PVC pipes etc.<br />

8.3.1. Pipe laying<br />

8.3.2. Laying of cast iron pipes :<br />

Inspection of pipes before laying :<br />

Before laying the pipes and fittings shall be inspected for defects and be rung with<br />

a light hammer, preferably while suspended, to detect cracks. Smearing the outside with<br />

chalk dust helps in the location of cracks. If doubt persists further confirmation may be<br />

obtained by pouring a little kerosene on the inside of the pipe at the suspected spot. If<br />

crack is present, the kerosene seeps thorough and shows on the outer surface. Any pipe<br />

found unsuitable after inspection before laying shall be rejected.<br />

Laying should be done as per IS code of practice 3114 (Third Revision).<br />

a) Depth of Trench – The depth of trench should be less than 900mm<br />

measured from the top of pipe to the surface of ground and not less than<br />

750mm else where.<br />

b) Width of Trench : The width of trench should be 200 mm more on either<br />

side of the external dia of pipe (i.e. External dia of pipe + 2 x 200mm).<br />

Additional width shall be provided at position of sockets and flanges for<br />

jointing.<br />

c) Cover over the pipe- Minimum cover of 1M in recommended under road way<br />

and may be modified to meet the local condition.<br />

8.3.3. Laying and jointing of ductile iron pipes :<br />

The pipes should be laid as per the specification laid down in IS : 12288.<br />

a) Width of Trench :- The width of trench at bottom shall provide not less than<br />

200mm clearance on both sides of pipe (i.e. external dia of pipe + 2x 200mm)<br />

b) Cover over the pipe – In agricultural land the depth should be sufficient to<br />

provide cover not less than 900mm and under a roadway the cover should be<br />

minimum 1.0M.<br />

8.3.4. Laying of welded steel pipes :<br />

The laying should be done as per IS – 5822 (First revision).<br />

a) Width of Trench – The width at the bottom below in the faces should not be<br />

less than 200 mm clearance on either side of the pipes.<br />

b) Cover over the pipe – When the pipeline is under a roadway, a minimum cover of<br />

1.0 Meter should be provided and can be modified to suit the local condition by<br />

taking necessary precaution.<br />

c) Pipe welding :- In case of welding the pipe in the trench, additional excavation<br />

of not more than 600 mm in depth 900mm in length should be provided all round<br />

the pipe at the position of the joints for facility of welding.<br />

d) Coating and wrapping of pipes :- Against internal corrosion, steel pipes are given<br />

epoxy lining or hot applied coal tar/asphalt lining or rich cement mortar lining at<br />

works or the field by centrifugal process. The outer coating for under ground<br />

CONTRACTOR<br />

25<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


26<br />

pipeline may be in cement sand gunniting or hot applied coal tar asphalt enamel<br />

reinforced with fiber glass fabric yarn. Coating and wrapping should be done as<br />

per IS 10221.<br />

8.3.5. Laying of PVC pipes :<br />

Laying and joining of PVC pipes should be done as per IS: 7634 (part – III).<br />

a) Width of trench :- The trench should be as narrow as practicable. As a normal<br />

practice this may be kept from 0.30M over the outside dia or pipe (i..e external dia<br />

of pipe + 30 cum.).<br />

b) Depth of Trench – The depth of trench should be 1.00M from the ground level.<br />

c) The trench bottom where it is rocky and un-even a layer of sand or alluvial earth of<br />

100mm depth should be provided under the pipe.<br />

d) Jointing of pipes : Solvent welding technique offers as easy and ample type of joint<br />

in PVC pipe used spigot and socket type joints. The cement solvent to be used for<br />

jointing should be as per the recommendations of the pipe manufacturer.<br />

8.4. Testing of pipe line after laying (field test pressure).<br />

After laying and jointing, the mains shall be slowly and carefully charged with<br />

water, so that all air is expelled from the main by providing a25mm inlet with a stop cock,<br />

allowed to stand full of water for a few days if time permits, and then tested with<br />

pressure.<br />

The field test pressure to be imposed should be not less than the maximum of the<br />

following.<br />

a) 1.5times the maximum sustained operating pressure.<br />

b) 1.5 times the maximum pipeline static pressure.<br />

c) Sum of the maximum sustained operating pressure and the maximum surge<br />

pressure.<br />

d) Sum of the maximum pipe line static pressure and the maximum equal to the work<br />

test pressure for any pipe fitting in corporate.<br />

9.0. Production wells (large dia tube wells):<br />

9.1. Materials for constructions :<br />

1. Casting pipes should be mild steel or UPVC pipes. Mild steel pipes should<br />

conform to IS :4270 and ASTM-DN-1785. The UPVC pipes should be of<br />

ASTM quality (Sch-40, Sch-80 or Sch-120 depending on site condition) and<br />

should also confirm to IS:2818.<br />

2. Well screens and slotted pipes should conform to IS : 8110. The well<br />

screens may be monometal, bimetal, stainless steel or PVC.<br />

Sufficient opening should be provided for screens and slotted pipes so that 70% or<br />

more of sand grains in the natural aquifer where uniformity co-efficient should range<br />

between 2.0 to 2.50. For soils with uniformly coefficient less than 1.5, pea gravel pack<br />

should be used.<br />

The total area of opening should be such s to maintain on entrance velocity less<br />

than necessary to carry the finest particle of sand that is to be excluded by the screen.<br />

In general, it should be 4 to 6 cm/sec. With the gravel shrouding.<br />

The opening should preferably be ‘V’ shaped.<br />

CONTRACTOR<br />

26<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


27<br />

3. Gravel to be used for shrouding (packing around the casing pipe) should confirm to<br />

IS : 4099. The gravel wall provided may vary in thickness to suit the size and depth<br />

of boring and may vary from 10cm to 25cm but usually 10cm.<br />

9.2. Construction of tube well :<br />

The drilling operation should be taken up with rotary drilling rig. Down the whole<br />

Hammer Rig or Combination Rig depending on type of strata and conforming to IS :2800<br />

(Part-I).<br />

For drilling with rotary drilling rig in soft formations, bentonite powder should be<br />

used in place of local mud as sealing compound to facilitate drilling operation. The casing<br />

pipe and well strainer should be lowered perfectly vertically and well screen should be<br />

properly placed against the aquifers. The casing pipe should be extended to at least 60 cm<br />

above the ground level.<br />

The annular space between the bore and the housing pipe (casing pipe) should be<br />

cement grouted upto at least 5m below ground level to provide a sanitary sealing.<br />

9.3. Testing and development of tube well :<br />

9.3.1. The testing of tube well should be conducted as per IS : 2800 (part-II).<br />

Tube wells are to be tested for plumbness and alignment normally after completion<br />

of drilling but immediately after the housing pipes are installed and prior to<br />

commencement of gravel fitting in the case of gravel shrouded tube well. For wells<br />

encased with pipes less than 350mm dia meter, the verticality of tube well shall have a<br />

deviation not exceeding 10cm per 30 m depth of the tube well and the deviation shall be in<br />

one direction and in one place only.<br />

In the case gravel shrouded tube well, if the pipe assembly is found included in a<br />

start position. It should be pulled in a desired directions to rectify the stantness and<br />

bringing the pipe assembly into permissible limit of verticality.<br />

9.3.2. Development of tubewell :<br />

The object of well development is the removal of silt, fine sand and other such<br />

materials form a zone immediately around the well, screen, there by creating larger<br />

passage in the formation through which water can flow more freely towards the<br />

wells.<br />

Well development includes the operation of flushing, testing and equipping the wells<br />

before they are put into service.<br />

The development should be carried on with an air compressor of suitable capacity<br />

(to develop 7kg to 10kg/Cm 2 and airflow of 2m 3 /min) In accordance with IS : 11189,<br />

and the process should be continued until the stabilization of sand gravel pack and<br />

discharge of clear water is fully assured.<br />

10. Pumping sets :<br />

10.1. Reference & code<br />

The pumping sets and accessories should conform to following IS specification:<br />

IS 1520<br />

Horizontal centrifugal pumps for clear cold fresh water (2 nd revision)<br />

CONTRACTOR<br />

27<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


28<br />

IS 6595<br />

IS 9684<br />

IS 1710<br />

IS 8034<br />

IS 10825<br />

Horizontal centrifugal pumps for clear cold fresh water for Agricultural<br />

purpose (first revision).<br />

Selection, installation, operation and maintenance of Horizontal centrifugal<br />

pumps for agricultural purpose.<br />

Vertical turbine pumps for clear. Cold fresh water (1 st revision).<br />

Submersible pump sets for clear, cold, fresh water.<br />

Foot valve, Reflex value or non return valve and bore valves to be used in<br />

suction line of agriculture pumping sets. (first revision).<br />

IS 325/19758<br />

Three phase induction motors.<br />

IS 7538<br />

Motors for submersible pumps<br />

10.2. Inspection of pumps before final acceptance.<br />

1. The name plates of the pump and motor with details like Sl. No.- Head,<br />

Discharge, rpm, HP/KW of motor etc engraved on the name plate should be<br />

clearly verified to confirm within the pumping set is as per the supply<br />

order.<br />

2. Manufacturer’s test report along with laboratory hydrostatic test reports<br />

of the pumps should be verified to know the duty of pump.<br />

3. The supplier should give at lest one copy of specific installation and<br />

operation manual of the pumping sets supplied by them.<br />

4. The field test for pumps should be conducted to confirm the duty of pumps<br />

after ins installation.<br />

10.3. Pump installation<br />

The installation of centrifugal pumps should proceed through five stages in the<br />

following order.<br />

1. Preparing the foundation and locate the foundation bolts.<br />

2. Locating the pump on the foundation bolts, however resting on leveling wedges,<br />

which permit not only easy leveling but also space for fitting the grunt later on.<br />

3. Levelling<br />

4. Grouting<br />

5. Alignment<br />

The foundation should be sufficiently substantial to absorb vibrating and to form a<br />

permanent, rigid support for the base plate.<br />

Alignment of the pump sets should be checked even if they are received aligned by<br />

the manufacturer. The alignment should be proper both for parallelism (by filler gauge)<br />

and for coasiablity (by straight edge or by dial gauge).<br />

During all alignment- checks both the shafts should be pressed hard, over to one<br />

side while talking the readings alignment should also be checked after fastening the piping<br />

and there after periodically during operation.<br />

Submersible pumps with wet type motors should be fitted with water and the<br />

opening should be properly plugged after filling water.<br />

Pumps kept in storage for a long time should be thoroughly cleaned before<br />

installation.<br />

CONTRACTOR<br />

28<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


29<br />

10.4. Testing of pumps :<br />

There are two types of pumps testing.<br />

1. Testing in the shop or laboratory at the manufacturer works.<br />

2. Testing in the field after installation<br />

Every pump must be tested before it is finally accepted. It is necessary for<br />

comparision of specified, predicated and actual performance after installation, relating<br />

to head, discharge power, efficiency and suction requirements centrifugal pumps should<br />

be listed as per IS-9137 (Class ‘C’ code of testing) and IS-11346.<br />

The scheme of testing includes taking readings, doing calculation and plotting of<br />

(i) The H-Q characteristics<br />

(ii) The P-Q characteristics.<br />

(iii) The efficiency versus Q characteristics<br />

11. Water Quality<br />

11.1. Recommended guidelines for physical and chemical parameter:<br />

Sl.<br />

No.<br />

Characteristics *Acceptable **Cause for<br />

1. Turbidity (NTU) 1 10<br />

2. Colour (Units on Platinum Cobalt<br />

scale)<br />

5 25<br />

3. Teste and Odour Unobjectionable Objectionable<br />

4. PH 7.0 to 8.5 9.0<br />

5. Total dissolved solids (mg/I) 500 2000<br />

6. Chlorides (as CI) (mg/I) 20 600<br />

7. Chlorides (as CI) (mg/I) 200 1000<br />

8. Sulphates (as SO 4 (mg/I) 200 400<br />

9. Fluorides (as F) (mg/I) 1.0 1.5<br />

10. Nitrates (as NO 3 (mg/I) 45 45<br />

11. Calcium (as Ca) (mg/I) 75 200<br />

12. Magnesium (as Mg) (mg/I) 30 150<br />

If there are 250 mg/I of sulphates, Mg content can be increased to maximum<br />

of 125mg/I with the reduction of sulphates at the rate of I unit per every 2.5 units<br />

of sulphates.<br />

Sl.<br />

No.<br />

Characteristics *Acceptable **Cause for<br />

13. Iron (as Fe) mg/I 0.1 1.0<br />

14. Manganese (as Mn) mg/I 0.05 0.5<br />

CONTRACTOR<br />

29<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


15. Copper (as Cu) (mg/I) 0.05 1.5<br />

16. Aluminium (as AI) (mg/I) 0.03 0.2<br />

17. Residual Chloride (mg/I) 0.2 >1.0<br />

18. Zinc (as Zn) (mg/I) 5.0 15.0<br />

19. Phenolic compounds (as Phenol)<br />

(mg/I)<br />

20. Anionic detergents (mg/I) (as<br />

MBAS)<br />

30<br />

0.001 0.002<br />

0.2 1.0<br />

21. Mineral Oil (mg/I) 0.01 0.03<br />

TOXIC MATERIALS<br />

22. Arsenic (as As) (mg/I) 0.01 0.05<br />

23. Cadmium (as CD) (mg/I) 0.01 0.01<br />

24. Chromium<br />

(as hexavalent Cr) (mg/I) 0.05 0.05<br />

25. Cyanides (as CN) (mg/I) 0.05 0.05<br />

26. Lead (as Pb) (mg/I) 0.05 0.05<br />

27. Selenium (as SC) (mg/I) 0.01 0.01<br />

28. Mercury (total as Hg)<br />

(mg/I) 0.001 0.001<br />

29. Polynuclear aromatic 0.2 0.2<br />

Hydrocarbons (PAH) (ug/I)<br />

Pesticides (total, mg/I) Absent Refer to WHO<br />

guidelines for<br />

drinking water<br />

quality Vol.-I-1993<br />

RADIO ACTIVITY<br />

30. Gross Alpha activity (Bq/I) 0.1 0.1<br />

31. Gross Beta activity (Bq/I) 0.1 1.0<br />

The figures indicated under the column ‘Acceptable’ are the limits upto which<br />

water is generally acceptable to the consumers.<br />

Figures in excess of those mentioned under ‘Acceptable’ render the water not<br />

acceptable, but still may be tolerated in the absence of an alternative and better source<br />

but upto the limits indicated under column “Cause for Rejection” above which the sources<br />

will have to be rejected.<br />

CONTRACTOR<br />

30<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


31<br />

It is possible that some mine and spring waters may exceed these radio activity<br />

limits and in such cases it is necessary to analyses the individual radio-nuclide order to<br />

assess the acceptability or otherwise for public consumption.<br />

<br />

Sr. Divisional Manager<br />

(Building Project-I)<br />

Sl.<br />

No<br />

PROFORMA-'A'<br />

CERTIFICATE OF LIST OF WORKS IN HAND<br />

I/We do hereby certify that the following works have been executed by<br />

me/us in the past.<br />

Particulars<br />

of works<br />

now in<br />

hand<br />

Amount of<br />

each work<br />

Period which<br />

the work is<br />

stipulated to<br />

be<br />

completed<br />

(in month)<br />

Approximate value<br />

of work done<br />

against each work<br />

on the date of<br />

submission of<br />

Tender<br />

Deptt.<br />

Under which<br />

the work is<br />

being taken<br />

up.<br />

Remark<br />

s<br />

1 2 3 4 5 6 7<br />

CONTRACTOR<br />

31<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


32<br />

I/We also note that, non-submission of this certificate may render my/our tender<br />

liable for rejection.<br />

Signature of the tenderer<br />

Date________________<br />

CERTIFICATE OF EMPLOYMENT OF UN-EMPLOYED GRADUATE<br />

ENGINEERS/DIPLOMA HOLDERS<br />

(For Special Class and 'A' Class Contractors only)<br />

I/We do hereby certify that at present the following Engineering personnel are<br />

working with me/in our firm/company and their bio-data are furnished below:<br />

Sl.<br />

No<br />

.<br />

Name of<br />

Engineering<br />

personnel<br />

appointed for<br />

supervising<br />

contractor's<br />

works with<br />

address<br />

Qualificat<br />

ion<br />

Date of<br />

appointme<br />

nt<br />

Monthly<br />

emolume<br />

nt<br />

Whether full<br />

time<br />

engagement<br />

and<br />

continuous<br />

If they are<br />

Superannuated/<br />

Retired/ dismissed<br />

or removed<br />

personnel from<br />

State Govt./<br />

Central Govt./<br />

Public sector<br />

undertakings/<br />

Private companies<br />

and firms or any<br />

one ineligible for<br />

Govt. service.<br />

1 2 3 4 5 6 7<br />

I/We also note that non-submission of this certificate may render my/our tenders<br />

liable for rejection.<br />

Signature of the tenderer<br />

Date________________<br />

CONTRACTOR<br />

32<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


33<br />

PROFORMA-'B'<br />

CERTIFICATE OF LIST OF WORKS EXECUTED<br />

I/We do hereby certify that the following works have been executed by<br />

me/us in the past.<br />

Sl.No.<br />

Particulars of<br />

works already<br />

executed<br />

Approximate<br />

amount of<br />

each work<br />

Name of<br />

Deptt.<br />

under<br />

which the<br />

works were<br />

executed<br />

Period of<br />

commencemen<br />

t and period<br />

of completion<br />

Whether the<br />

works were<br />

completed in<br />

stipulated<br />

period<br />

1 2 3 4 5 6 7<br />

Remark<br />

s<br />

I/We also note that, non-submission of this certificate may render my/our tender<br />

liable for rejection.<br />

Signature of the tenderer<br />

Date________________<br />

CONTRACTOR<br />

33<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


34<br />

WORK PROGRAMME<br />

Name of the Work: Construction of Tourist Reception Centre at Saunleipitha in Ganjam<br />

District. under Destination Development Scheme<br />

Time<br />

Description of work<br />

1 st Month<br />

2 nd Month<br />

3 rd Month<br />

4 th Month<br />

5 th Month<br />

6 th Month<br />

CONTRACTOR<br />

34<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


35<br />

TENDER SCHEDULE FOR THE WORK:- Construction of Tourist Reception Centre at<br />

Saunleipitha in Ganjam District. under<br />

Destination Development Scheme<br />

Sl.<br />

No<br />

Description of Items Qnty. Unit Rate Amount<br />

1 2 3 4 5 6<br />

PUBLIC CONVENIENCE<br />

1 Earthwork in excavation of foundation<br />

trenches in ordinary soil including moorum<br />

stoney earth and earth mixed with<br />

boulders except sheet rock and boulders<br />

requiring blasting including dressing of<br />

sides and leveling the bed up to the<br />

required depth and depositing the<br />

excavated materials away from the work<br />

site with all leads and lifts, including<br />

shoring, shuttering and dewatering (if<br />

required) with cost of labour, hire &<br />

running charges of water pumps sundries &<br />

T&P required for the work complete as<br />

directed by the Engineer-in-charge. 345.09 Each Cum 39.09 13489.57<br />

2 Supplying and filling in foundation trenches<br />

and plinth, ditches with sand well watered<br />

and rammed in layers not exceeding 23 cm.<br />

In depth with all lead and lift including<br />

cost, conveyance, loading, unloading,<br />

royalties and taxes of all materials, cost of<br />

all labour, sundries, T&P required for the<br />

work etc. complete in all respect as per<br />

specification and direction of Engineer-incharge.<br />

(Measurement will be taken on<br />

finished compacted section only). 1096.89 Each Cum 180.80 198317.71<br />

3 Providing and lying plain cement concrete<br />

of proportion (1:4:8) in foundation and<br />

floors using Portland Slag Cement(PSC)<br />

with 4 cm. Size black hard crusher broken<br />

granite stone metal and screened and<br />

washed sharp sand for mortar of approved<br />

quality from approved quarry, washed and<br />

cleaned including hoisting, lowering, laying<br />

concrete, ramming, watering and curing<br />

etc. complete to required levels laid in<br />

layers not exceeding 15 cm thick in each<br />

layer including cost, conveyance, loading, 87.28 Each Cum 2825.80 246635.82<br />

CONTRACTOR<br />

35<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


36<br />

unloading, royalties and taxes all materials<br />

and cost all labours, sundries, T & P<br />

required for the work including shoring,<br />

shuttering and dewatering if required<br />

including hire & running charges of water<br />

pump complete as per specification and<br />

direction of Engineer-in-charge.<br />

4 Providing Random Rubble stone masonry in<br />

cement mortar of mix (1:6) with Portland<br />

slag cement (PSC) in foundation & plinth<br />

with screened and washed sharp sand for<br />

mortar of approved quality from approved<br />

quarry and using black hard hand broken<br />

granite stone free from weathered skins<br />

of approved size, weight and quality from<br />

approved quarry including providing key<br />

stones in regular intervals for each layer<br />

including splays cutting, circular moulding<br />

and similar such type of works with all<br />

necessary projections, champering and<br />

corbelling, watering and curing etc. with all<br />

cost, conveyance, royalties, loading &<br />

unloading & tax of all materials and cost of<br />

all labour, sundries, T & P required for the<br />

work including hoisting, lowering,<br />

dewatering if required etc. complete in all<br />

respect as directed by Engineer-in-Charge 172.64 Each Cum 1802.80 311235.39<br />

5 Providing, lifting, hoisting and laying<br />

Reinforced cement concrete of M-200<br />

grade as per approved designs and<br />

drawings having a minimum compressive<br />

strength (in work test) 200 Kg. / Square<br />

cm. in 15 cm. cubes at 28 days after mixing<br />

and test conducted in accordance with I.S.<br />

516 using 12 mm. to 20 mm. size black hard<br />

crushed broken granite stone chips and<br />

screened and washed sharp sand for<br />

mortar of approved quality from approved<br />

quarry, washed and cleaned ( 20mm. size<br />

chips not to exceeds 25 % ) to be mixed in<br />

concrete mixture with Portland slag<br />

cement (PSC) including hoisting, lowering,<br />

laying and compaction concrete by using<br />

vibrators, watering and curing for 28 days,<br />

centering and shuttering then after<br />

CONTRACTOR<br />

36<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


dismantling and removing debris from the<br />

work site and finishing the exposed<br />

surface smooth providing grooves or beads<br />

wherever necessary including cost,<br />

conveyance, loading, unloading, royalties<br />

and taxes of all materials and cost of all<br />

labours, sundries, T & P required of the<br />

work etc. complete in all respect as<br />

directed by the Engineer-in-Charge. But<br />

excluding cost and conveyance of M.S. rods<br />

or Tor steel and binding wires and labour<br />

charges for straightening, cutting, bending<br />

etc. of M.S. rods or tor steel tying the<br />

grills and placing in proper position.<br />

a) Column base<br />

37<br />

i)Ground floor<br />

b) Column<br />

i)Ground floor<br />

ii)First floor<br />

c) Plinth band/ Grade beam<br />

i)Ground floor<br />

d) Lintel<br />

i)Ground floor<br />

ii)First floor<br />

e) Beam<br />

i)Ground floor<br />

ii)First floor<br />

f) Roof slab<br />

i)Ground floor<br />

ii)First floor<br />

g) Staircase<br />

i)Ground floor<br />

h) Chajja<br />

CONTRACTOR<br />

37<br />

27.59 Each Cum 4465.10 123192.11<br />

7.52 Each Cum 6834.50 51395.44<br />

1.60 Each Cum 7351.50 11762.40<br />

21.38 Each Cum 4701.70 100522.35<br />

3.95 Each Cum 6560.70 25914.77<br />

0.63 Each Cum 7023.00 4424.49<br />

14.53 Each Cum 6834.50 99305.29<br />

1.96 Each Cum 7351.50 14408.94<br />

28.9 Each Cum 6639.90 191893.11<br />

3.38 Each Cum 7118.10 24059.18<br />

1.08 Each Cum 6544.90 7068.49<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


38<br />

i)Ground floor<br />

ii)First floor<br />

i)shelf<br />

15.24 Each Sqm 534.00 8138.16<br />

0.74 Each Sqm 585.60 433.34<br />

Ground floor<br />

4.49 Each Sqm 414.00 1858.86<br />

6 Providing, fixing and placing of MS bars/<br />

Tor steel (HYSD) for RCC work in all<br />

floors of required diameter of approved<br />

quality with straightening, Cutting,<br />

bending, binding welding or jointing if<br />

necessary, bending, binding, tying the grills<br />

as required for R.C.C. works, providing fan<br />

hooks where necessary and hoisting,<br />

lowering and placing in proper position<br />

according to approved designs and<br />

drawings including cost, conveyance,<br />

loading, unloading, taxes of M.S. rods or<br />

Tor steel and binding wires of 18 to 20<br />

gauge required for the work and cost of all<br />

labour, sundries, T & P and scaffolding<br />

complete in all respect as directed by the<br />

Engineer-in-Charge ( payment will be made<br />

according to the actual weight of M.S rod<br />

/Tor steel consumed in the work and no<br />

separate payment will be made towards<br />

weight of binding wires which is to be<br />

borne by the contractor at his own cost<br />

i)Ground floor<br />

111.56 Each Qntl 6270.40 699525.82<br />

ii)First floor<br />

10.06 Each Qntl 6276.80 63144.61<br />

7 First class well burnt brick masonry using<br />

K.B. bricks of size 23 cm. x 11 cm. x 8 cm.<br />

Having crushing strength not less than 75<br />

kg. Per Sqr. Cm. In cement mortar of mix<br />

(1:6) with screened and washed sharp sand<br />

for mortar after immersing the bricks for<br />

6 (six) hours in water before use in<br />

foundation and plinth for masonry work,<br />

ornamental flower beds, plinth moulding<br />

and similar such type of works with all<br />

necessary projections, splays cutting,<br />

circular moulding, corbelling, chamfering<br />

watering and curing etc. including cost, 56.10 Each Cum 2530.60 141966.66<br />

CONTRACTOR<br />

38<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


39<br />

conveyance, loading, unloading, royalties<br />

and taxes of all materials and cost of all<br />

labour, sundries, T&P required for the<br />

works etc. complete in all respect as per<br />

specification and direction of Engineer-incharge.<br />

8 First class well burnt brick masonry using<br />

K.B. bricks of size 23 cm. x 11 cm. x 8 cm.<br />

Having crushing strength not less than 75<br />

kg. Per Sqr. Cm. In cement mortar of mix<br />

(1:6) with screened and washed sharp sand<br />

for mortar after immersing the bricks for<br />

6 (six) hours in water before use in<br />

superstructure for masonry work,<br />

ornamental flower beds, plinth moulding<br />

and similar such type of works with all<br />

necessary projections, splays cutting,<br />

circular moulding, corbelling, chamfering<br />

watering and curing etc. including cost,<br />

conveyance, loading, unloading, royalties<br />

and taxes of all materials and cost of all<br />

labour, sundries, T&P required for the<br />

works etc. complete in all respect as per<br />

specification and direction of Engineer-incharge.<br />

i)Ground floor<br />

ii)First floor<br />

9 Providing 16mm thick cement plaster in all<br />

floors at all height with cement mortar of<br />

mix (1:6) with Portland slag cement (PSC)<br />

and with screened and washed sharp sand<br />

for mortar and finished smooth to the<br />

rough surface of brick masonry walls after<br />

racking out joints including watering and<br />

curing rounding of corners etc. complete<br />

with cost, conveyance, loading, unloading,<br />

royalties and taxes of all materials, cost of<br />

all labour, T&P, sundries and scaffolding<br />

required for the work etc. with providing<br />

grooves as directed by the Engineer-in-<br />

Charge<br />

i)Ground floor<br />

ii)First floor<br />

CONTRACTOR<br />

39<br />

57.07 Each Cum 2564.00 146327.48<br />

21.87 Each Cum 2636.20 57653.69<br />

470.59 Each Sqm 81.70 38447.20<br />

116.28 Each Sqm 83.00 9651.24<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


40<br />

10 Providing 12mm. thick cement plaster with<br />

cement mortar of mix (1:6) in all floors<br />

with Portland slag cement (PSC) with neat<br />

cement punning and two coats of bitumen<br />

painting over top of the walls complete<br />

including watering and curing along with<br />

the cost, conveyance, loading and unloading,<br />

royalties and taxes of all materials and<br />

cost of all labours, sundries, T&P and<br />

scaffolding required for the work etc.<br />

complete in all respect as directed by the<br />

Engineer–in-Charge.<br />

i)Ground floor 220.78 Each Sqm 60.90 13445.50<br />

ii)First floor 100.21 Each Sqm 62.40 6253.10<br />

11 Providing 6 mm. thick cement plaster with<br />

cement mortar of mix (1:4) in all floors at<br />

all height with screened and washed sharp<br />

sand for mortar to ceiling plaster of roof<br />

slab, staircase, landings, chajja and shelves<br />

etc. including roughening, scraping,<br />

chiseling, cleaning closed deep chipping<br />

with slurry treatment and finished smooth<br />

to all R.C.C surface including cost,<br />

conveyance, loading, unloading, royalties<br />

and taxes of all materials, cost of all<br />

labour, sundries, T&P , scaffolding,<br />

watering and curing etc. complete in all<br />

respect as per specification and direction<br />

of Engineer-in-charge.<br />

i)Ground floor 283.60 Each Sqm 65.70 18632.52<br />

ii)First floor 22.14 Each Sqm 66.70 1476.74<br />

12 20mm. thick cement plaster in cement<br />

mortar (1:6) finished smooth to stone<br />

masonry after racking out joints including<br />

watering & curing with cost, conveyance,<br />

royalties, loading, unloading and taxes of all<br />

materials and cost of all labour, T&P,<br />

sundries, scaffolding etc. required for the<br />

work as directed by the Engineer-in-<br />

Charge. 138.79 Each Sqm 93.30 12949.11<br />

13 Providing 20mm thick granite tile flooring<br />

(using granite tile above 0.4 sqm ) of<br />

approved quality, colour and size in floors,<br />

treads on steps and landings in all floors at<br />

all height on 25mm thick bed of cement<br />

CONTRACTOR<br />

40<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


41<br />

mortar of mix (1:1) laid in proper slope and<br />

gradient with screened and washed sharp<br />

sand for mortar and grouted with neat<br />

white cement slurry joining the tile with<br />

neat white cement slurry mixed with<br />

required quantities of pigments of<br />

approved marks to match the shades of<br />

the granite tile if required watering and<br />

curing for 21 days, including cost,<br />

conveyance, loading, unloading, royalties<br />

and taxes of all materials, cost of all<br />

labour, sundries, T&P required for the<br />

work including rubbing mechanically and<br />

wax polishing etc. complete in all respect<br />

as per specification and direction of<br />

Engineer-in-charge.<br />

i)Ground floor 166.90 Each Sqm 2025.00 337972.50<br />

ii)First floor 5.19 Each Sqm 2027.70 10523.76<br />

14 Providing 10mm thick granite tile(using<br />

granite tile above 0.1 Sqm. Up to 0.4 sqm )<br />

of approved quality, colour and size in<br />

Dadoes over 12mm thick cement plaster<br />

1:3 (1 Cement: 3 Coarse sand) finished with<br />

modular pointing in white cement & pigment<br />

to match the shade of the tiles including<br />

cost, conveyance, loading, unloading,<br />

royalties and taxes of all materials, cost of<br />

all labour curing sundries and T & P etc.<br />

required for the work etc. complete as per<br />

specification and direction of Engineer-incharge.<br />

21.48 Each Sqm 1308.20 28100.14<br />

15 Providing 30cmx30cm/40cmx40cm special<br />

plain/printed series ceramic floor tiles of<br />

premium grade having thickness 7mm to<br />

8mm conforming IS13755 for ceramic tile<br />

flooring of approved quality, colour and<br />

size in floors, treads on steps and landings<br />

in all floors at all height on 10mm thick bed<br />

of cement mortar of mix (1:1) laid in proper<br />

slope and gradiant with screened and<br />

washed sharp sand for mortar and with<br />

ordinary Portland slag cement (PSC)<br />

grouted with neat white cement slurry<br />

joining the tile with neat white cement<br />

slurry mixed with required quantities of 45.23 Each Sqm 636.30 28779.85<br />

CONTRACTOR<br />

41<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


42<br />

pigments of approved marks to match the<br />

shades of the ceramic tile if required ,<br />

watering and curing for 21 days, including<br />

cost, conveyance, loading, unloading,<br />

royalties and taxes of all materials, cost of<br />

all labour, sundries, T&P required for the<br />

work including rubbing mechanically and<br />

wax polishing etc. complete in all respect<br />

as directed by the Engineer-in-charge.<br />

16 Providing 20cmx30cm/20cmx20cm special<br />

plain/printed series ceramic glazed wall<br />

tiles of premium grade having thickness<br />

6.5mm to6.7mm conforming IS 13753 of<br />

approved make & shade in Dadoos over<br />

12mm thick cement plaster 1:3 (1 Cement:<br />

3 Coarse sand) finished with modular<br />

pointing in white cement & pigment to<br />

match the shade of the tiles including cost,<br />

conveyance, loading, unloading, royalties<br />

and taxes of all materials, cost of all<br />

labour curing sundries and T & P etc.<br />

required for the work etc. complete as per<br />

specification and direction of Engineer-incharge.<br />

119.88 Each Sqm 520.40 62385.55<br />

17 Supplying, fitting and fixing well dressed<br />

and well seasoned sal wood choukaths of<br />

different length and 6.35cm. x 12.70cm.<br />

sizes in all floors in proper position<br />

including two coats coats of coaltaring to<br />

wall and lintel side faces of choukaths<br />

including cost of coaltar and labour for<br />

coaltaring and fixing required nos. of W.I.<br />

clamps to the choukaths with approved<br />

qualities of screws including cost,<br />

conveyance, loading, sundries, T&P required<br />

for the work etc. complete in all respect as<br />

directed by the Engineer-in-charge but<br />

excluding the cost of W.I. clamps. 0.26 Each Cum 37316.90 9702.39<br />

18 Supplying, fitting & fixing of Flush door<br />

using 32mm thick BWR Block Board(I.S.I)<br />

with 4mm thick teak wood veneer both side<br />

including melamine polish etc complete with<br />

Floor spring (make- Godrej),Door<br />

stopper(DS1),Handel(Godrej make 10Ck<br />

Universal Brass Handel Set) including 13.66 Each Sqm 5925.90 80947.79<br />

CONTRACTOR<br />

42<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


43<br />

necessary Hardware and other required<br />

fittings complete in all respect with cost<br />

of all materials and labour all taxes<br />

,transportation and as per the drawings<br />

given by Architect and the direction of the<br />

Engineer -in- charge.<br />

19 Providing and fixing factory made UPVC<br />

frame with shutter for windows made of<br />

UPVC extruded section having an overall<br />

dimension, as below (tolerance ± 1mm) with<br />

all thickness 2mm ± 0.2mm .Corners of the<br />

door frame to be jointed with galvanized<br />

brackets and stainless steel screws,<br />

jointed and mired and plastic welded. The<br />

hinge side vertical of the frame<br />

reinforced by galvanized M.S tube of size<br />

19mmx19mm and 1mm ± 0.1mm wall<br />

thickness and 3 no stainless steel hinges<br />

fixed to the frame complete as per<br />

manufacture specification and direction of<br />

Engineer in charge.(Extruded section<br />

profile size 42x50mm) :(MAKE :LG or<br />

equivalent ) complete in all respect as<br />

directed by the Engineer-in-charge. 18.68 Each Sqm 5489.80 102549.46<br />

20 Providing fitting and fixing of 30mm thick<br />

factory made of solid panel PVC door<br />

shutter ( conforming to criteria of testing<br />

as per IS:4020 with upto date<br />

amendments) of approved quality<br />

consisting of frame made out of M.S. tubes<br />

of 19 gauge thickness and size of 19mm x<br />

19mm for stiles, and 15mm x 15mm for top<br />

and bottom rails. M.S. frame shall have a<br />

coat of steel primers of approved make<br />

and manufacture. M.S. frame shall be<br />

covered with 5mm thick heat moulded “<br />

Rajshri” PVC ‘C’ channel of size 30 x 50mm<br />

forming stiles, and 5mm thick, 75mm wide<br />

PVC sheets for top rail, lock rail and<br />

bottom rail on either side, and 10mm (5mm<br />

x 2) thick, 20mm wide cross PVC sheet as<br />

gap insert for top rail and bottom rail.<br />

Paneling of 5mm thick PVC sheet to be<br />

fitted in the M.S. frame welded/sealed to<br />

the stiles and rails with 30mm wide x 5mm 14.63 Each Sqm 2506.00 36662.78<br />

CONTRACTOR<br />

43<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


thick PVC sheet beading on either side, and<br />

joined together with solvent cement<br />

adhesive etc. an additional 5mm thick PVC<br />

strip of 20mm width is to be stuck on the<br />

interior side of the ‘C’ channel using PVC<br />

solvent adhesive including PVC door frame<br />

(Choukhat) of PVC Hollow Door Frame of<br />

size 50mmx47mm with a wall thickness of<br />

5mm,made out of extruded 5mm rigid PVC<br />

foam sheet, miter cut at two corners and<br />

joined with 2nos. of 150mm long brackets<br />

of 15x15mm M.S. square tube. The two<br />

vertical door profiles are to be reinforced<br />

with 19x19mm M.S. Square tube of 19<br />

gauge, EPDM rubber gasket Weather seal<br />

to be provided through out the frame. The<br />

door frame shall be fixed to the wall using<br />

65/100mm long M.S. Screws through the<br />

frame by using PVC fasteners. A minimum<br />

of 4nos. of screws to be provided for each<br />

vertical member & minimum 2nos. for<br />

horizontal member of approved quality<br />

including drilling holes in masonry wall<br />

with cost of all materials, rawlplug , screws<br />

and other required fittings with cost of all<br />

materials, all taxes, labour T & P etc<br />

complete as per specification and direction<br />

of Engineer –in-charge.<br />

44<br />

21 Supplying, fitting and fixing of Stainless<br />

steel of 304 grade in hand railing using<br />

50mm dia of 2mm thick circular pipe with<br />

balustrade of size 32mm x 32mm x 2mm @<br />

0.90mtr. C/C and stainless square pipe<br />

bracing of size 32mm x 32mm x 2mm in 3<br />

rows in stair case as per approved design<br />

and specification, buffing, polishing etc.<br />

with cost, conveyance, taxes of all<br />

materials, T & P etc. required for the<br />

complete in all respect as directed by the<br />

Engineer-in-charge. 16.64 Each Rmt 3169.00 52732.16<br />

22 French polishing two coats to Doors &<br />

Windows with any approved polish or with<br />

prepared polishing materials like sprit, lac<br />

be required to give the best polished 8.10 Each Sqm 44.20 358.02<br />

CONTRACTOR<br />

44<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


45<br />

surface to wood work after cleaning the<br />

surface smooth including the cost,<br />

conveyance, loading, unloading and taxes of<br />

all materials and cost of all labour, T & P,<br />

sundries required for the work complete in<br />

all respect as directed by the Engineer-incharge.<br />

23 Providing and painting two coats with<br />

plastic emulsion paint of approved quality<br />

and approved shade manufactured by<br />

reputed manufacture like NEROLAC<br />

/ASIAN /BERGER /DULOX or equivalent<br />

to make in all floors at all height by making<br />

the surface to the interior plastered<br />

surface of wall smooth with a coat of<br />

Acrylic Putty and primer of approved<br />

quality including cost, conveyance, loading<br />

and unloading and taxes of all materials,<br />

cost of all labour, sundries, T & P,<br />

scaffolding etc. required for the work and<br />

complete in all respect as per specification<br />

and direction of Engineer-in-charge.<br />

i)Ground floor 665.17 Each Sqm 118.50 78822.65<br />

ii)First floor 60.71 Each Sqm 119.30 7242.70<br />

24 Wall painting two coats with 100% Acrylic<br />

emulsion paint (1 st quality) exterior grade<br />

(weather coat) of approved make & shade<br />

manufactured by reputed manufacture like<br />

NEROLAC /ASIAN /BERGER /DULOX or<br />

equivalent to make an even finished<br />

surface over a coat of primer with water<br />

bond cement primer in all heights with all<br />

scaffolding and staging charges including<br />

cost, conveyance, taxes of all materials,<br />

cost of all labour, etc. complete as per<br />

specification and direction of Engineer-in-<br />

Charge. 0.00<br />

i)Ground floor 448.59 Each Sqm 56.50 25345.34<br />

ii)First floor 170.65 Each Sqm 57.30 9778.25<br />

PH<br />

25 Supplying all material and labour tools and<br />

plants & fitting, including testing & jointing<br />

of the following Astral CPVC pipes and<br />

fittings in SDR 11 and SDR 13.5 fittings<br />

having ISI mark with points including<br />

CONTRACTOR<br />

45<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


46<br />

supply of pipe and pipes to lengths<br />

including wastage providing necessary<br />

offsets and long screw with extra socket<br />

and jam nut including earthwork in<br />

excavation of pipe line trenches in 0.3048<br />

mtr. layers with fully watering and ramming<br />

, providing pegs , threads, lights , barriers<br />

etc., or fixing to walls & floors with supply<br />

of holder-bat-clamps fixing wooden plugs<br />

in walls complete as per I.S specification<br />

including cost , conveyance and taxes of all<br />

materials etc., complete and as per the<br />

direction of Engineer-in-charge<br />

(Make- Oriplast/ Supreme)<br />

a) 20mm dia CPVC pipe 65.00 Each Rmt 94.60 6149.00<br />

b) 40mm dia CPVC pipe 35.00 Each Rmt 219.00 7665.00<br />

c) 50mm dia CPVC pipe 40.00 Each Rmt 356.40 14256.00<br />

26 Providing fitting & fixing of the following<br />

SWR U-PVC pipes as per IS-13592<br />

(Oriplast/Supreme) and fittings as per IS-<br />

14735 on the wall surface below the floor<br />

and ground level for use as soil waste and<br />

anti-syphonic pipes fixing the pipes and<br />

fitting on the wall<br />

a)75mm dia UPVC pipe 16.20 Each Rmt 123.80 2005.56<br />

b)110mm dia UPVC pipe 70.00 Each Rmt 220.10 15407.00<br />

27 Providing and fixing porcelain EWC with “P”<br />

of “S” trap with vent horn ISI marked and<br />

approved make (Hind ware- Cat. No-<br />

92058)(S-22) coupled with 10 litres<br />

capacity PVC cistern Florence (Pastel)<br />

make Hindware model no-92122(White)of<br />

approved make necessary bracket, screw<br />

etc. complete with other components like<br />

commode seat and lid, special attachment<br />

for coupling the cistern on the top of EWC,<br />

PVC water connection pipe, 450 mm long<br />

cutting the floor and wall including mending<br />

good the damages, including cost of all<br />

materials as per direction E.I.C. 2 Each No 12908.60 25817.20<br />

28 Providing and installing vitreous china<br />

Orissa pattern water closet pan of Size<br />

58cmx43cm of Hindware cat. No-20070)<br />

with 10lt capacity cistern 100mm SCI P or<br />

S trap complete including cost of all 5 Each No 3838.60 19193.00<br />

CONTRACTOR<br />

46<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


47<br />

materials, all taxes and as per direction of<br />

E.I.C.<br />

29 Providing and installing vitreous china Flat<br />

back Large urinal ( Cat. No-60002, Pastel)<br />

of Hindware with automatic flushing<br />

cistern complete with all required fittings<br />

including cost of all materials as per<br />

direction E.I.C. 2 Each No 7297.30 14594.60<br />

30 Providing and installing vitreous china<br />

Counter Top basin of size 55cmx46cmof<br />

Lara of make Hind ware cat. No-91039<br />

Pastel ) complete including cost of all<br />

materials, all taxes and as per direction of<br />

E.I.C. 6 Each No 5393.60 32361.60<br />

31 Providing and installing vitreous china wash<br />

basin of size 46cmx36cm of WINDSOR of<br />

make Hind ware cat. No-10036 Pastel)<br />

with all fittings complete including cost of<br />

all materials, all taxes complete as per PH<br />

specification & direction of E.I.C. 1 Each No 2873.60 2873.60<br />

32 Providing and fixing Concealed stop cocks<br />

of make JAQUAR cat. No-KUB-35089<br />

(KUBIX) with all fittings complete<br />

including cost of all materials, all taxes<br />

complete as per PH specification &<br />

direction of E.I.C. . . 14 Each No 1528.10 21393.40<br />

33 Providing and fixing Over Head Shower<br />

150mm dia Round Shape Single flow with<br />

Rubit Cleaning system (cat. No OHS-1803)<br />

of JAQUAR with all fittings complete<br />

including cost of all materials, all taxes<br />

complete as per PH specification &<br />

direction of E.I.C. 3 Each No 3250.80 9752.40<br />

34 Providing and fixing of towel ring (cat. No -<br />

AKB-35721 of JAQUAR ) with all fittings<br />

complete including cost of all materials, all<br />

taxes complete as per PH specification &<br />

direction of E.I.C. 4 Each No 1047.00 4188.00<br />

35 Providing and fixing of two way Bib cock<br />

with wall flange (KUBIX ) (cat. No -AKB-<br />

35041 of JAQUAR ) with all fittings<br />

complete including cost of all materials, all<br />

taxes complete as per PH specification &<br />

direction of E.I.C. 8 Each No 1723.70 13789.60<br />

36 Providing and fixing of Florentine Bib cock 1 Each No 1420.70 1420.70<br />

CONTRACTOR<br />

47<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


48<br />

with with Extended lever Handle & wall<br />

flange (cat. No - FLR-5043, Jaquar) with<br />

all fittings complete including cost of all<br />

materials, all taxes complete as per PH<br />

specification & direction of E.I.C.<br />

37 Providing and fixing of click clark waste<br />

32mm size Half Thread with 80 mm height<br />

with wall flange (cat. No -ALD-709 of<br />

JAQUAR ) with all fittings complete<br />

including cost of all materials, all taxes<br />

complete as per PH specification &<br />

direction of E.I.C. 6 Each No 265.00 1590.00<br />

38 Providing and fixing of Soap Dish (cat. No-<br />

AKB-35731 of JAQUAR ) with all fittings<br />

complete including cost of all materials, all<br />

taxes complete as per PH specification &<br />

direction of E.I.C. 15 Each No 921.20 13818.00<br />

39 Providing and fixing of Toilet paper (cat.<br />

No -AKB-35753 of JAQUAR) complete<br />

including cost of all materials, all taxes<br />

complete as per PH specification &<br />

direction of E.I.C. 2 Each No 1148.50 2297.00<br />

40 Providing and fixing of Hand<br />

shower(Health Faucet) with 8mm dia<br />

1metre long Flexible Tube with wall Hook<br />

with NRV (Black Flow Preventer) (cat. No -<br />

ALD-577 of JAQUAR) complete including<br />

cost of all materials, all taxes complete as<br />

per PH specification & direction of E.I.C. 2 Each No 1483.30 2966.60<br />

41 Supply of all materials, labour, T&P , fitting<br />

and fixing in all floors fixed type beveled<br />

plate glass mirror of size 600mm x<br />

450mm x 5.5mm thick best Indian make<br />

,supply of 13mm thick asbestos backing and<br />

CP Brass screw including cost conveyance,<br />

taxes of all materials complete as per PH<br />

specification and direction of Engineer-incharge(Make-Modi<br />

Guard/Belgium) 6 Each No 500.00 3000.00<br />

42 Providing and fixing of Brass/Gun metal<br />

Full way Valve (Leader/Shakti/Laxmi or<br />

equivalent) with C.I. wheel of approved<br />

quality including jointing as per<br />

specification complete including cost of all<br />

materials, all taxes complete as per PH<br />

specification & direction of E.I.C.<br />

CONTRACTOR<br />

48<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


49<br />

a) 50mm dia 4 Each No 2506.90 10027.60<br />

b)25mm dia 7 Each No 647.20 4530.40<br />

43 Providing and fixing of 125 mm dia CP<br />

Grating of approved quality including cost<br />

of all materials, all taxes complete as per<br />

PH specification & direction of E.I.C. 11 Each No 59.35 652.85<br />

44 Providing and fixing Marble Partition (<br />

105cm x 60cm x1.8 cm) using 16mm thick<br />

Marble Tile of approved quality etc.<br />

complete including all fittings complete as<br />

per PH specification and direction of the<br />

Engineer-in-charge. 1.86 Each Sqm 631.20 1174.03<br />

45 Providing and fixing C.P. Glass shelf of<br />

Kubix (cat. No -AKB-35771) of Jaquar with<br />

5mm thick Glass ,fixed to wall including<br />

cutting the wall and making good the<br />

damages, including cost of all materials<br />

complete as per PH specification and<br />

direction of Engineering-in-charge. 3 Each No 1502.00 4506.00<br />

46 Supplying all materials , labour T&P and<br />

fittings required for fixing of NP or CP<br />

Brass or GM fixtures of following sizes and<br />

specification with leak proof threaded<br />

joints tightened with spun yarn and white<br />

zinc or any other method as required as<br />

directed including testing and rectification<br />

of detects, after testing complete as per<br />

direction of Engineer-in-charge.(Make-<br />

Jaquar).<br />

a) Providing and fixing 2’ Single Towel rail<br />

of Kubix (cat. No -AKB-35711) of Jaquar<br />

with all fittings complete including cost of<br />

all materials, all taxes complete as per PH<br />

specification & direction of E.I.C. 3 Each No 1199.00 3597.00<br />

Physically Challanged<br />

47 Providing and fixing Wall mounted Back<br />

Support for Toilet Seat(-Model no-EGBS<br />

020 WH of ENOX )with all fittings<br />

complete with testing including cost of all<br />

materials, labour, all taxes complete as<br />

per PH specification & direction of E.I.C. 1 Each No 16100.00 16100.00<br />

48 Providing and fixing Wall mounted shower<br />

chair with Cushioning Device-(Model no-<br />

EGBS 022 WH of ENOX) with all fittings<br />

complete with testing including cost of all 1 Each No 41650.00 41650.00<br />

CONTRACTOR<br />

49<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


50<br />

materials, labour, all taxes complete as<br />

per PH specification & direction of E.I.C.<br />

49 Providing and fixing Wall mounted Toilet<br />

Handle support for Multi function (Model<br />

no-EGBS 002 WH of ENOX )with all<br />

fittings complete with testing including<br />

cost of all materials, labour, all taxes<br />

complete as per PH specification &<br />

direction of E.I.C. 1 Each No 15750.00 15750.00<br />

50 Providing and fixing Wall mounted<br />

Surface Finger Grip Support Handle<br />

(Model no-EGBS 009 WH-300 of ENOX)<br />

with all fittings complete with testing<br />

including cost of all materials, labour, all<br />

taxes complete as per PH specification &<br />

direction of E.I.C. 1 Each No 2975.00 2975.00<br />

SEPTIC TANK<br />

51 Earthwork in excavation of foundation<br />

trenches in ordinary soil including dressing<br />

of sides and leveling the bed up to the<br />

required depth and depositing the<br />

excavated materials away from the work<br />

site with all leads and lifts, including<br />

shoring, shuttering and dewatering (if<br />

required) with cost of labour, hire &<br />

running charges of water pumps sundries &<br />

T&P required for the work complete as<br />

directed by the Engineer-in-charge. 41.33 Each Cum 39.09 1615.59<br />

52 Supplying and filling in foundation trenches<br />

and plinth, ditches with sand well watered<br />

and rammed in layers not exceeding 23 cm.<br />

In depth with all lead and lift including<br />

cost, conveyance, loading, unloading,<br />

royalties and taxes of all materials, cost of<br />

all labour, sundries, T&P required for the<br />

work etc. complete in all respect as per<br />

specification and direction of Engineer-incharge.<br />

(Measurement will be taken on<br />

finished compacted section only). 3.02 Each Cum 180.80 546.02<br />

53 Providing and lying plain cement concrete<br />

of proportion (1:2:4) in foundation and<br />

floors using Portland Slag Cement(PSC)<br />

with 12 mm. Size black hard crusher<br />

broken granite stone metal and screened<br />

and washed sharp sand for mortar of 2.02 Each Cum 4384.80 8857.30<br />

CONTRACTOR<br />

50<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


approved quality from approved quarry,<br />

washed and cleaned including hoisting,<br />

lowering, laying concrete, ramming,<br />

watering and curing etc. complete to<br />

required levels laid in layers not exceeding<br />

15 cm thick in each layer including cost,<br />

conveyance, loading, unloading, royalties<br />

and taxes all materials and cost all labours,<br />

sundries, T & P required for the work<br />

including shoring, shuttering and<br />

dewatering if required including hire &<br />

running charges of water pump complete as<br />

per specification and direction of<br />

Engineer-in-charge.<br />

54 Providing, lifting, hoisting and laying<br />

Reinforced cement concrete of M-200<br />

grade in plinth protection as per approved<br />

designs and drawings having a minimum<br />

compressive strength (in work test) 200<br />

Kg. / Square cm. in 15 cm. cubes at 28 days<br />

after mixing and test conducted in<br />

accordance with I.S. 516 using 12 mm. to<br />

20 mm. size black hard crushed broken<br />

granite stone chips and screened and<br />

washed sharp sand for mortar of approved<br />

quality from approved quarry, washed and<br />

cleaned ( 20mm. size chips not to exceeds<br />

25 % ) to be mixed in concrete mixture<br />

with Portland slag cement (PSC) including<br />

hoisting, lowering, laying and compaction<br />

concrete by using vibrators, watering and<br />

curing for 28 days, centering and<br />

shuttering then after dismantling and<br />

removing debris from the work site and<br />

finishing the exposed surface smooth<br />

providing grooves or beads wherever<br />

necessary including cost, conveyance,<br />

loading, unloading, royalties and taxes of all<br />

materials and cost of all labours, sundries,<br />

T & P required of the work etc. complete in<br />

all respect as directed by the Engineer-in-<br />

Charge. But excluding cost and conveyance<br />

of M.S. rods or Tor steel and binding wires<br />

and labour charges for straightening,<br />

cutting, bending etc. of M.S. rods or tor<br />

51<br />

CONTRACTOR<br />

51<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


52<br />

steel tying the grills and placing in proper<br />

position.<br />

a) Raft 1.89 Each Cum 4465.10 8439.04<br />

b)Wall 5.75 Each Cum 6206.40 35686.80<br />

c) Roof slab 1.26 Each Cum 6639.90 8366.27<br />

55 Providing, fixing and placing of MS bars/<br />

Tor steel (HYSD)(TATA/SAIL) for RCC<br />

work of required diameter of approved<br />

quality with straightening, Cutting,<br />

bending, binding welding or jointing if<br />

necessary, bending, binding, tying the grills<br />

as required for R.C.C. works, providing fan<br />

hoocks where necessary and hoisting,<br />

lowering and placing in proper position<br />

according to approved designs and<br />

drawings including cost, conveyance,<br />

loading, unloading, taxes of M.S. rods or<br />

Tor steel and binding wires of 18 to 20<br />

gauge required for the work and cost of all<br />

labour, sundries, T & P and scaffolding<br />

complete in all respect as directed by the<br />

Engineer-in-Charge ( payment will be made<br />

according to the actual weight of M.S rod<br />

/Tor steel consumed in the work and no<br />

separate payment will be made towards<br />

weight of binding wires which is to be<br />

borne by the contractor at his own cost 8.04 Each Qntl 6270.40 50414.02<br />

56 Providing 12mm. thick cement plaster with<br />

cement mortar of mix (1:4) in all floors<br />

with Portland slag cement (PSC) and with<br />

screened and washed sharp sand for<br />

mortar with neat cement punning for<br />

skirting finished smooth to brick walls in<br />

dadoes and skirting after racking out the<br />

joints including watering and curing<br />

complete with cost, conveyance, loading<br />

and unloading, royalties and taxes of all<br />

materials, cost of all labour, sundries, T&P,<br />

scaffolding required for the work etc.<br />

complete in all respect as directed by the<br />

Engineer-in-Charge. 32.04 Each Sqm 83.80 2684.95<br />

57 Providing 20mm OMS step iron as per<br />

design and drawing complete including cost<br />

conveyance, taxes of all materials, labour,<br />

T & P, loading and unloading etc. complete 11 Each No 150.00 1650.00<br />

CONTRACTOR<br />

52<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


53<br />

as per specification and direction of<br />

Engineer-in-charge.<br />

58 Making soak pit 1.2m diameter 2.59 m deep<br />

with 45x45 cm dry brick honey comb<br />

shaft with bricks of class designation 75<br />

and S.W. drain pipe 100 mm diameter ,1.8<br />

m long complete as per standard design.<br />

With F.P.S. brick including cement<br />

concrete cover etc. completein all respect<br />

with all cost, conveyance, royalties, loading<br />

& unloading & tax of all materials and cost<br />

of all labour, sundries, T & P required for<br />

the work including hoisting, lowering,<br />

dewatering if required etc. complete in all<br />

respect as directed by Engineer-in charge. 3 Each No 9900.00 29700.00<br />

59 Supplying all materials, labours, T&P and<br />

constructing gully trap chamber of<br />

250mmx250mm inside size with 8cm thick<br />

RCC precast cover slab in cement concrete<br />

(1:2:4) mix using 12mm size hg chips,<br />

foundation concrete (1:4:8) using 40mm<br />

size hard granite metal on bed and around<br />

trap, KB brickwork in cement mortar (1:6)<br />

in F&P and inside 12mm thick cement<br />

plaster in cement mortar (1:3) finished<br />

with a floating coat of neat cement<br />

including fixing 100mmx100mm size HCI<br />

gully trap,150mm x150mm size CI grating<br />

etc all complete as per approved drawing,<br />

PH specification and direction of Engineerin-charge.<br />

10 Each No 903.70 9037.00<br />

60 Constructing brick masonary Manhole<br />

chamber with 75 class designation bricks<br />

in cement mortar 1:4 (1 cement :4 coarse<br />

sand) R.C.C top slab with 1:2:4mix(1<br />

cement:2 coarse sand :4 graded stone<br />

aggregate 20 mm nominal size, foundation<br />

concrete 1:4:8 (1 cement:4 coarse sand : 8<br />

graded stone aggregate 40 mm nominal<br />

size) inside plastering 12 mm thick with<br />

cement mortar 1:3(1 cement :3 coarse sand<br />

) finished with floating oat of neat cement<br />

and making channels in cement concrete<br />

1:2:4 (1 cement :2 coarse sand :4 graded<br />

stone aggregate 20 mm nominal size ) 15 Each No 6141.90 92128.50<br />

CONTRACTOR<br />

53<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


54<br />

finished with a floating coat of neat<br />

cement complete as per standard design.<br />

Inside dimensions 900 mmx900mmx750mm<br />

deep including C I cover with frame (light<br />

duty 455x610 mm internal dimensions total<br />

weight of cover and frame to be not less<br />

than 38 kg ( weight of cover 23 kg and<br />

weight of frame 15 kg) /RCC Precast Slab<br />

with F P S brick. as per approved drawing,<br />

PH specification and direction of Engineerin-charge.<br />

61 Providing and fixing 2000 litres capacity<br />

P.V.C Over head (Sintex make)tank over<br />

RCC(1:1.5:3) Staging with all piping and<br />

valve arrangement with all labour &<br />

materials ,including cost, T&P , scaffolding<br />

etc., complete as directed by the Engineerin-charge.<br />

2 Each No 11000.00 22000.00<br />

ELECTRICAL WORK<br />

62 Recessed wiring to light point with 1.5<br />

sq.mm FR PVC insulated single core<br />

multistrand copper conductor of ISI<br />

marked with 20 mm dia non-metallic PVC<br />

flexible conduit with S.P. 5 / 6 amps, one<br />

way modular switch, ISI marked type<br />

switch, Modular base & cover for 1 module,<br />

Modular G.I. box for 2 module 18 SWG ISI<br />

marked and ceiling rose ISI marked<br />

mounted on MS box having front Bakelite<br />

cover of suitable size , MS box with 1.5<br />

sq.mm FR PVC insulated single core multi<br />

strand copper conductor as earth wire<br />

including all accessories and connection as<br />

per direction of Engineer in Charge. ( Make<br />

of wire Finolex/ L&T / Anchor / Havels / V<br />

Guard )<br />

Group-A 10 Each No 467.00 4670.00<br />

Group-B 12 Each No 566.00 6792.00<br />

Group-C 12 Each No 700.00 8400.00<br />

63 Recessed wiring to ceiling fan point with<br />

1.5 sq.mm FR PVC insulated single core<br />

multi strand copper conductor of ISI<br />

marked with 20 mm dia non-metallic PVC<br />

flexible conduit with S.P. 5 / 6 amps, one<br />

way modular switch, ISI marked type<br />

CONTRACTOR<br />

54<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


55<br />

switch, Modular base & cover for 1 module,<br />

Modular G.I. box for 2 module 18 SWG ISI<br />

marked and ceiling rose ISI marked<br />

mounted on MS box having front Bakelite<br />

cover of suitable size , MS box with 1.5<br />

sq.mm FR PVC insulated single core multi<br />

strand copper conductor as earth wire<br />

including all accessories and connection as<br />

per direction of Engineer in Charge. ( Make<br />

of wire Finolex/ L&T / Anchor / Havels / V<br />

Guard )<br />

Group-B 6 Each No 566.00 3396.00<br />

Group-C 6 Each No 1063.00 6378.00<br />

64 Recessed wiring to exhaust fan point with<br />

1.5 sq.mm FR PVC insulated single core<br />

multistrand copper conductor of ISI<br />

marked with 20 mm dia non-metalic PVC<br />

flexible conduit with S.P. 5 / 6 amps, one<br />

way modular switch, ISI marked type<br />

switch, Modular base & cover for 1 module,<br />

Modular G.I. box for 2 module 18 SWG ISI<br />

marked and ceiling rose ISI marked<br />

mounted on MS box having front Bakelite<br />

cover of suitable size , MS box with 1.5<br />

sq.mm FR PVC insulated single core<br />

multistrand copper conductor as earth wire<br />

including all accessories and connection as<br />

per direction of Engineer in Charge. ( Make<br />

of wire Finolex/ L&T / Anchor / Havels / V<br />

Guard ) including cost, all taxes complete in<br />

all respect as per specification and<br />

direction of Engineer-in-charge<br />

Group-A 9 Each No 467.00 4203.00<br />

65 Recessed wiring to submain in 2 x 2.5<br />

sq.mm FR PVC insulated single core<br />

multistrand copper conductor of ISI<br />

marked confirming to IS-694/1990 in 20<br />

mm dia non-metallic heavy duty flexible<br />

conduit 1.6 mm thick along with 1 x 1.5<br />

sq.mm FR PVC insulated single core<br />

multistrand copper conductor as earth wire<br />

as required.(Make of wire<br />

Finolex/L&T/Anchor/Havels/V Guard)<br />

including cost, all taxes complete in all<br />

respect as per specification and direction 150.00 Each Mtr 96.00 14400.00<br />

CONTRACTOR<br />

55<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


56<br />

of Engineer-in-charge<br />

66 Recessed wiring for power plug with 2 x 4<br />

sq.mm FR PVC insulated single core multi<br />

strand copper conductor of ISI marked<br />

with 20 mm dia non-metallic PVC flexible<br />

conduit along with 1 x 2.5 sq.mm FR PVC<br />

insulated single core multistrand copper<br />

conductor for loop earthing as required. (<br />

Make of wire Finolex / L&T /Anchor /<br />

Havels / V Guard ) including cost, all taxes<br />

complete in all respect as per specification<br />

and direction of Engineer-in-charge 120.00 Each Mtr 133.00 15960.00<br />

67 Recessed wiring for power plug with 4<br />

x6sq.mm FR PVC insulated single core multi<br />

strand copper conductor of ISI marked<br />

with 20 mm dia non-metallic PVC flexible<br />

conduit / casing caping along with 1 x 2.5<br />

sq.mm FR PVC insulated single core multi<br />

strand copper conductor for loop earthing<br />

as required. ( Make of wire Finolex / L&T<br />

/Anchor / Havels / V Guard ) 15.00 Each Mtr 275.00 4125.00<br />

68 Recessed wiring for power plug with 2<br />

x6sq.mm FR PVC insulated single core<br />

multistrand copper conductor of ISI<br />

marked with 20 mm dia non-metallic PVC<br />

flexible conduit / casing caping along with 1<br />

x 2.5 sq.mm FR PVC insulated single core<br />

multistrand copper conductor for loop<br />

earthing as required. ( Make of wire<br />

Finolex / L&T /Anchor / Havels / V Guard ) 15.00 Each Mtr 156.50 2347.50<br />

69 Point wiring for 5 / 6 amp mudolar socket<br />

outlet with 2 x 1.5 sq.mm FR PVC insulated<br />

single core multi strand copper conductor<br />

of ISI marked in recess 20 mm dia nonmetallic<br />

PVC flexible conduit with modular<br />

type switch ,phenolic laminated sheet<br />

suitable size ISI marked MS box and<br />

earthing point with 1 x 1.5 sq.mm FR<br />

PVCinsulated single core multistrand<br />

copper conductor for loop earthing etc. as<br />

required. ( Make of wire Finolex /L&T /<br />

Anchor / Havels / V Guard ) 8 Each No 652.00 5216.00<br />

70 Supply and fixing a set of 1 no modular grid<br />

plate mounted 240 volt 6 amp 4 pin<br />

universal round/flat pin combined 6 Each No 463.00 2778.00<br />

CONTRACTOR<br />

56<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


57<br />

shuttered socket outlet with 240 volt 6<br />

amp control switch, all housed in a 3 module<br />

recessed zinc chromate passivated MS box<br />

including moulded cover plate etc. complete<br />

as required.<br />

71 Supply and fixing a set of 1 no modular grid<br />

plate mounted 240 volt 6/16 amp 4 pin<br />

universal round/flat pin combined<br />

shuttered socket outlets each with 240<br />

volt 16 amp control switch, all housed in a<br />

single 4 module recessed zinc chromate<br />

passivated MS box including one moulded<br />

cover plate etc. complete as required. 2 Each No 632.00 1264.00<br />

72 Supplying and fixing of 15A /16A Modular<br />

Switch with 4 Modular metal box with<br />

cover of in Recess including providing and<br />

fixing connection, etc as required.(For<br />

plugs to be used in non residential<br />

buildings) including cost, all taxes complete<br />

in all respect as per specification and<br />

direction of Engineer-in-charge 4 Each No 354.00 1416.00<br />

73 Supplying and fixing of 15A /16A Modular<br />

socket with 4 Modular metal box with<br />

cover of in Recess including providing and<br />

fixing connection, etc as required.(For<br />

plugs to be used in non residential<br />

buildings) including cost, all taxes complete<br />

in all respect as per specification and<br />

direction of Engineer-in-charge 4 Each No 414.00 1656.00<br />

74 Supply, Installation, Testing, and<br />

commissioning of ceiling fan 1200 mm<br />

sweep 230/250 volts, 50HZ complete with<br />

suitable, clamp, down rod, blades, canopy,<br />

rubber, shackle, and connections with 1.5<br />

sq.mm PVC insulated copper conductor<br />

cable etc as required. ( Havells SS 390/<br />

Equivalent) 12 Each No 2601.00 31212.00<br />

75 Supply, Installation, Testing, and<br />

commissioning of Exhaust fan 250mm dia<br />

900mm suitable to work on 230/250 volts,<br />

50HZ complete with mounting frame and<br />

louvers including making the hole to suit<br />

the size of above fan, making good the<br />

damage, connections, with 1.5 sq.mm PVC<br />

insulated, copper conductor, single core 9 Each No 1809.00 16281.00<br />

CONTRACTOR<br />

57<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


58<br />

cable etc including all accessories and<br />

connection as per direction of Engineer in<br />

Charge.<br />

76 Supplying & fixing of15W CFL TARNADO<br />

(Philips) etc. complete. 16 Each No 210.00 3360.00<br />

77 Supply & Fixing of 1 x 28 watt T5 4' long<br />

flouroscent tube light fitting on wall<br />

surface complete with 1 no of 28 watt T5<br />

tube of approved make complete with all<br />

other necessary fixing materials including<br />

termination and labour.(Make : Phillips /<br />

Equivalent) 15 Each No 957.00 14355.00<br />

78 Supply & fixing of 4 way, Triple pole and<br />

Neutral, sheet steel MCB double door<br />

distribution box complete with tinned<br />

copper busbar, neutral link, earth bar, din<br />

rail, detachable gland plate including 1 no.<br />

of 63A TPN MCB as I/C , 8 no. of 6/10<br />

Amps, 10kA rating, 240Volts, Single pole<br />

Miniature Circuit Breaker in each phase as<br />

O/G of approved make complete with<br />

connections, testing and commissioning &<br />

all other required materials etc including<br />

all accessories and connection as per<br />

direction of Engineer in Charge. 1 Each No 5242.00 5242.00<br />

79 Supply & fixing of 2 way, Single pole and<br />

Neutral, sheet steel MCB double door<br />

distribution box complete with tinned<br />

copper busbar, neutral link, earth bar, din<br />

rail, detachable gland plate including 1 no.<br />

of 63A TPN MCB as I/C , 10no. of 6/10<br />

Amps, 10kA rating, 240Volts, Single pole<br />

Miniature Circuit Breaker in each phase as<br />

O/G of approved make complete with<br />

connections, testing and commissioning &<br />

all other required materials etc including<br />

all accessories and connection as per<br />

direction of Engineer in Charge. 1 Each No 3763.00 3763.00<br />

80 Providing and making earth pits including<br />

the cost of 2mm thick 2.5 mtr. long 50 mm<br />

dia pipe, CI funnel with wire mesh charcoal,<br />

salt, all earth work, masonry enclosure with<br />

CI frame & 300 mm x 300 mm cover plate<br />

having locking arrangement complete as per<br />

IS 3043:1987 for LT Panel including all 2 Each No 3000.00 6000.00<br />

CONTRACTOR<br />

58<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


59<br />

accessories and connection as per direction<br />

of Engineer in Charge.<br />

81 Supplying and laying of the following<br />

earthling clamped to wall with suitable<br />

clamps saddles and fixing bolts/ in ground<br />

including the cost of digging and back<br />

filling with sand and brick protection as<br />

required and complete as required including<br />

all accessories and connection as per<br />

direction of Engineer in Charge.<br />

19 mm x 3 mm GI strip 25.00 Each Mtr 79.50 1987.50<br />

82 Supply & lying with following 1.1 kv grade<br />

XLPE / PVC insulated, PVC sheathed AYFY<br />

Al conductor cable of approved make in<br />

existing cable trance / direct laying<br />

complete with dressing etc along with<br />

other necessary materials and labour<br />

including all accessories and connection as<br />

per direction of Engineer in Charge.<br />

3.5c x 25 sq.mm 1.1kv grade AYFY AL.<br />

cable 50.00 Each Mtr 322.00 16100.00<br />

83 Supply , Installation, testing &<br />

commissioning of the following indoor wall<br />

mounted type L.T Distribution panel board<br />

of 415V , 50Hz. Power supply made out of<br />

1.6mm thick CRCA steel duly de rusted &<br />

painted with two coats of light grey &<br />

enamel paint of approved shade over a coat<br />

of primer, dust, damp & vermin proof,<br />

cubicle fixed on M.S angle channel base,<br />

having compartmental arrangement for<br />

each equipment and suitable size of<br />

Aluminium bus bar having provision for<br />

cable entry at bottom, providing Earthling<br />

point to terminate 19mm x 3mm G.I flat,<br />

Nomenclature plate, Enameled danger<br />

board, earthling studs as per specification<br />

mentioned below duly factory wired<br />

confirming to the relevant ISS including all<br />

accessories and connection as per direction<br />

of Engineer in Charge.<br />

a)One no of 200Amp 16kA 4P MCCB.<br />

b)1 set of 3 ph. 25 x 6 mm size cu. Bus bar<br />

(250A)<br />

c)One no of 63Amp 4P Change over.<br />

CONTRACTOR<br />

59<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


60<br />

d)1 set of 3 ph. 25 x 6 mm size cu. Bus bar<br />

(100A)<br />

e)3 nos. of 100 Amp TPN MCB.<br />

f)3 nos. of 32 Amp TPN MCB.<br />

The panel board should contain Toggle<br />

switch, 3 ph.(R,Y,B) Indicator, Voltmeter<br />

(0-500v), Ammeter (0-100A) with Selector<br />

Switch & 3 nos. of 100/5 A CT of<br />

approved make should be fixed in wall at a<br />

suitable place along with other necessary<br />

materials and labour. 1 Each No 48500.00 48500.00<br />

84 Supply , Installation, testing &<br />

commissioning of 9mtr long tubular pole of<br />

size 5''x4''x3'' with round type head<br />

braket of 2''dia GI Bracket with provison<br />

for 4nos light fittings as per approved<br />

make & Model as per specification and<br />

direction of Engg –in- Charge. 3 Each No 25000.00 75000.00<br />

85 Supply , Installation, testing &<br />

commissioning Non integral floodlight<br />

luminaries with pressure die cast aluminium<br />

housing and heat resistant toughened flat<br />

glass (IP 65) complete with external single<br />

CG BoxRVP302 2xSONT400W*<br />

2xSONT400W (Phillips) as per approved<br />

make & Model as per specification and<br />

direction of Engg –in- Charge. 12 Each No 15500.00 186000.00<br />

86 Supply of 10 sq.mm 2 core PVC Armoured<br />

Cables ISI Marked as per approved make &<br />

Model as per specification and direction of<br />

Engg –in- Charge. 300.00 Each Mtr 115.00 34500.00<br />

87 Laying of one number of PVC insulated and<br />

PVC seatheled / XLPE power cable of 1.1<br />

KV grade of size not exceeding 25 sq.mm<br />

direct in ground including excavation, sand<br />

Cushing, protective covering and refilling<br />

the trench etc. as required. 300.00 Each Mtr 75.00 22500.00<br />

88 Supply and installation of Floor type<br />

outdoor panel board 100 AMP DP Switch<br />

and 100A DP CUPPER BUS BAR ISI<br />

Marked as per approved make & Model as<br />

per specification and direction of Engg –in-<br />

Charge. 1 Each No 15000.00 15000.00<br />

DEEP TUBE WELL<br />

89 Labour for drilling a perfectly bore hole<br />

CONTRACTOR<br />

60<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


61<br />

for specified dia for specified depth below<br />

G.L through consolidated and<br />

unconsolidated rocks with fast drilling<br />

sophisticated DTH/combination rig to suit<br />

the site condition as per the direction of<br />

the Engineer-in-charge including use of<br />

own Rigs with it accessories, T&P<br />

consumables etc.,for lowering of 200mm<br />

dia GI/PVC pipe for housing fitted with<br />

socket and with or without well screen as<br />

per necessity for soft , medium, hard &<br />

boulder formation (GI/PVC/MS casing pipe<br />

if required to prevent collapse of over<br />

burden is to be provided by the contractor<br />

including lowering and withdrawing after<br />

completion of Tube well) 200mm doa to<br />

400mm dia in overburden portion including<br />

packing of gravel etc. complete as per<br />

direction of Engineer-in-charge.<br />

a) 200 mm dia<br />

1) 0 Mtr to 30 Mtr 30.00 Each Mtr 748.00 22440.00<br />

2) 30 Mtr to 164 Mtr 134.00 Each Mtr 828.00 110952.00<br />

90 Lowering the following size of G.I.<br />

/PVC/MS housing pipe with or without<br />

slotted pipes as per the necessity from<br />

ground level up to 45mtr depth fitted and<br />

fixed up in perfectly vertical position<br />

including cutting & threading of pipes &<br />

slotted pipes & supplying & fixing all<br />

jointing materials, tools & plant etc. all<br />

complete & keeping the top of casing pipe<br />

threaded including plugging tube-wells to<br />

prevent entry of foreign materials and<br />

keeping the casing pipe 1.00mtr above GL.<br />

etc. complete as per direction of Engineerin-charge.<br />

a) 200 mm dia<br />

1) 0 Mtr to 30 Mtr 30.00 Each Mtr 76.00 2280.00<br />

2) 30 Mtr to 120 Mtr 90.00 Each Mtr 99.00 8910.00<br />

91 Cleaning and developing the tube well with<br />

their own compressor continuously worked<br />

till clear and adequate discharge is<br />

obtained from the tube well including<br />

supply and use of all necessary equipments<br />

and labour as per direction of Engineer-in- 1 Each No 2895.00 2895.00<br />

CONTRACTOR<br />

61<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


62<br />

charge.<br />

92 Supplying all materials, labour, T&P and<br />

providing sanitary sealing by cement<br />

concretes grouting of annular space around<br />

G.I./PVC/M.S. Housing pipe up to 5 meters<br />

below G.L. to plug the bore including cost<br />

of cement etc all complete as per the<br />

direction of Engineer-in-charge minimum<br />

one mtr casing pipe to be inserted in the<br />

bore into the rock at the bottom to ensure<br />

sanitary sealing. 1 Each No 999.00 999.00<br />

93 Supplying all materials, labour, T&P for<br />

fitting and fixing of PVC casing pipe<br />

(ASTM D 1785 Sch-80) of following dia<br />

with socket including cost of all materials,<br />

all taxes, all labour, transportation to sites<br />

etc. complete as per PH specification &<br />

direction of Engineer-in-charge<br />

(Oriplast/Finolex or Equivalent).<br />

150 mm dia PVC Pipes 120.00 Each Mtr 1030.00 123600.00<br />

94 Supplying fitting, fixing of 5.00 HP<br />

submersible pump TEXMO Make ( model<br />

No: TRF -2025S+SF037) or Equivalent<br />

including cost of all materials,<br />

transportation and taxes of pump etc.<br />

complete as per PH specification &<br />

direction of Engineer-in-charge. 1 Each Set 24450.00 24450.00<br />

95 Supplying all materials, labour, T&P for<br />

fitting and fixing of required control panel<br />

of approved quality including DOL starter<br />

with indicator 32 Amp TPN main switch<br />

including connection, installation etc. all<br />

complete as per specification & direction<br />

of Engineer-in-charge. 1 Each Set 2250.00 2250.00<br />

96 Supplying, fitting and fixing of 3core flat<br />

industrial cable for submission conforming<br />

to IS 694 Flexible 1100V. To IS 694.<br />

including all cost of material, labour, T&P<br />

etc all complete.(Make:Havels/ Finolex or<br />

Equivalent. 80.00 Each Mtr 139.60 11168.00<br />

97 Supplying all materials, labour, T&P for<br />

fitting and fixing of HDPC pipe of approved<br />

quality as directed by Engineer-in – charge.<br />

a) 40 mm dia HDPC Pipes 45.00 Each Mtr 63.00 2835.00<br />

98 Supplying, fitting, fixing of S.S tapper 1 Each Set 1600.00 1600.00<br />

CONTRACTOR<br />

62<br />

Sr.DIVISIONAL MANAGER (B.P.)-I


63<br />

2nos of 0.45mtr long M.S supporting<br />

clamps with M.S nuts & bolt and 200mm<br />

tube well cover & cap suitable for the<br />

above pump sets.<br />

Total-Rs. 49,79,240.06<br />

Say Rs. 49,79,000.00<br />

(Rupees Forty nine lakh Seventy nine thousand) only.<br />

Total: 98 (Ninety eight) Items only.<br />

N.B: The tenderer is required to quote only the percentage excess or less over the<br />

estimated cost here-below both in words and figures:<br />

( )<br />

(In figures)<br />

(In words)<br />

NO. OF CORRECTIONS ………………………IN ITEM NO………………….<br />

NO. OF OVERWRITING……………………….IN ITEM NO…………………<br />

NO. OF INTERPOLATIONS…………………IN ITEM NO………………….<br />

CONTRACTOR<br />

63<br />

Sr.DIVISIONAL MANAGER (B.P.)-I