ODISHA TOURISM DEVELOPMENT CORPORATION LIMITED (A ...
ODISHA TOURISM DEVELOPMENT CORPORATION LIMITED (A ...
ODISHA TOURISM DEVELOPMENT CORPORATION LIMITED (A ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
1<br />
<strong>ODISHA</strong> <strong>TOURISM</strong> <strong>DEVELOPMENT</strong> <strong>CORPORATION</strong> <strong>LIMITED</strong><br />
(A Govt. of Orissa Undertaking)<br />
Panthanivas (Old Block): Lewis Road: Bhubaneswar-14<br />
(BUILDING PROJECT DIVISION-I)<br />
DETAILED TENDER CALL NOTICE<br />
With Tender Schedule<br />
PERCENTAGE RATE TENDER<br />
Name of Work: Construction of Tourist Reception Centre at Saunleipitha in Ganjam<br />
District. under Destination Development Scheme.
2<br />
<strong>ODISHA</strong> <strong>TOURISM</strong> <strong>DEVELOPMENT</strong> <strong>CORPORATION</strong> <strong>LIMITED</strong><br />
(A Government of Orissa Undertaking)<br />
BUILDING PROJECT DIVISION-I<br />
Sl.<br />
No.<br />
Detailed Tender Call Notice<br />
Sealed tenders in conformity with DTCN eventually to be drawn in P.W.D. form F-2<br />
are invited in prescribed form from registered contractors of state<br />
PWD/Irrigation/CPWD/MES/Railway and other Government organizations for the<br />
following works<br />
Name of work<br />
Estimate cost<br />
(Rs in lakhs.)<br />
Cost of<br />
Tender<br />
paper<br />
( Nonrefunda<br />
ble)<br />
EMD<br />
( 1%<br />
estimated<br />
cost)<br />
Class of<br />
Contract<br />
or<br />
Period of<br />
completion<br />
1 2 3 4 5 6 7<br />
1. Construction of Tourist<br />
Reception Centre at<br />
Saunleipitha in Ganjam<br />
District.<br />
under<br />
Destination Development<br />
Scheme.<br />
Rs49,79,000.00<br />
Rs6000+<br />
4%VAT.<br />
Rs.49,790.00 “B‘’ & “A” 6(Six)<br />
Calendar<br />
Months.<br />
The details of tender documents can be had from our Web site:<br />
www.panthanivas.com. The Tender paper will be received up to 3 P.M of 31.05.2012 at<br />
O.T.D.C. Head office by speed post/registered post only and will be opened on the same day<br />
at 4.00 P.M. O.T.D.C. Ltd will not be held responsible for postal delay.<br />
The Authority reserves the right to reject any or all the tenders without assigning<br />
any reason thereof.<br />
CONTRACTOR<br />
2<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
3<br />
TERMS & CONDITIONS<br />
1. Eligibility criteria:<br />
The tender documents should contain the following requirements without<br />
which the tender shall be liable for rejection .<br />
a) The cost of Tender paper (at col-4 above) in shape of Bank Draft in favour of<br />
the Managing Director, O.T.D.C. Ltd payable at any nationalized bank,<br />
Bhubaneswar. .<br />
b) EMD 1% (one percent) of estimated cost put to tender(at col-5 above) in<br />
shape of P.O.S.B. /P.O.T.D. /N.S.C. /K.V.P. /Deposit Receipt of schedule Bank<br />
etc. duly pledged in favour of Managing Director OTDC Ltd. Bhubaneswar/<br />
Bank Draft in favour of the Managing Director, O.T.D.C. Ltd payable at any<br />
Nationalized bank, Bhubaneswar .<br />
c) Attested copies of valid contractor registration License<br />
d) Attested copies of VAT Clearance Certificate/ TIN No<br />
e) Attested copies of Up to date PAN CARD<br />
f) Attested copies of E.P.F. Registration Certificate.<br />
2. The tender should be sealed with wax properly with own seal.<br />
3. The sealed envelope containing the tender should be super scribed with the<br />
name of the work and should be addressed to the Sr.Divisional Manager<br />
(B.P.-I),OTDC Ltd. Bhubaneswar.<br />
4. PENALTY CLAUSE:<br />
Penalty @ 1% of the agreement value per month (30days) computed on perday<br />
basis shall be imposed for delay from the stipulated date of completion.<br />
5. Percentage Rate Tender :<br />
The tender will be on percentage rate over the estimated cost and not on item rate<br />
basis as per works department letter no codes-5/07-17190 dt.09.10.07. The<br />
percentage rate over the estimated cost should be quoted both in words and<br />
figures. In case of discrepancy between words and figures, the words shall prevail.<br />
6 (a) The Plan and Specification for the work can be seen at the Office of the<br />
Sr. Divisional Manager (BP)-I, O.T.D.C.Ltd, during working hours and days.<br />
Complaints at a future date that the plan and specification have not been seen, will<br />
not be entertained.<br />
(b) All other information can be had from the Sr.Divisional Manager (BP)-I,<br />
O.T.D.C. ltd.<br />
7 Additional performance security shall be deposited by the bidders when the<br />
bid amount is seriously unbalanced i.e. less than the estimated cost by more<br />
than 10%. In such an event, the bidder will deposit the additional<br />
performance security to the extent of the differential cost of the bid amount<br />
and 90% of the estimated cost in shape of post office savings bank<br />
Account/National Savings Certificate/Post Office Time Deposit Account/<br />
Kissan Vikash Patra/ Deposit receipt of schedule Bank at the time of<br />
execution of agreement. Failing on which the tender is liable for rejection.<br />
8 The Managing Director, O.T.D.C. Ltd. reserves the right to reject any or all<br />
tenders received without assigning any reason thereof.<br />
CONTRACTOR<br />
3<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
4<br />
9 EARNEST MONEY DEPOSIT AND INITIAL SECURITY DEPOSIT<br />
The tenderers whose tender is selected for acceptance shall within a period of<br />
seven days upon written intimation being given to him of acceptance of his tender<br />
make an initial security deposit of 1% (one percent) of the tendered amount as<br />
shown in clause.3 above so that the earnest money and initial security deposit will<br />
be 2% of the tendered amount and sign the agreement in the Office of<br />
O.T.D.C.Ltd, failing which, the tender will be rejected with forfeiture of E.M.D.<br />
This security deposit, together with the earnest money and the amount withheld if<br />
any shall be retained as security deposit for the due fulfillment of this contract.<br />
Failure to enter into the required agreement and to make the security deposit, as<br />
above shall entail forfeiture of the Earnest Money. No tender shall be finally<br />
accepted until the required amount of security deposit (money) is deposited. The<br />
written agreement to be entered into between the contractor and the Corporation<br />
shall be the foundation of the right of both the parties and the contract shall<br />
deem to be incomplete until the agreement has first been signed by the contractor<br />
and then by the Sr.Divisional Manager (BP)-I, O.T.D.C.Ltd.<br />
10 The contractors will be responsible for payment of all royalties or other charges<br />
for quarrying materials. All local taxes inclusive of State Sales Tax and Income<br />
Tax, Octroi charges, Ferry and Tollage charges are to be paid by the Contractor.<br />
11 I.T.C.C/PAN and S.T.C.C./VATCC :<br />
The tender may not, at the discretion of the competent authority, be considered<br />
unless accompanied with attested true copy of the PAN card and VAT clearance<br />
certificate as the case may be and the original certificate to be produced at the<br />
time of opening of tenders.<br />
12 If the contractor removes any materials or stock so supplied to him from the site<br />
of work with a view to disposing off the same dishonestly, he should in addition to<br />
any other liabilities Civil or Criminal arising out of the contract be liable to pay a<br />
penalty equivalent to five times the price of the materials on stock according to<br />
the stipulated rates and the penalty so imposed shall be recovered from any sum<br />
that may then or at any time thereafter become due to the contractor or from his<br />
security.<br />
13 The contractor should be fully liable to indemnify the Corporation for payment of<br />
any compensation under Workmen's Compensation Act-V-III of 1923 on account<br />
of the workmen being employed by him and the full amount of compensation paid<br />
will be recovered from the contractor.<br />
14 Every tenderer must examine the detailed specification of Orissa before<br />
submitting his tender. The right is reserved without impairing the contract to<br />
make such increase or decrease in the quantities or items of work mentioned in<br />
the schedule attached to the tender notice as may be considered necessary to<br />
complete the work fully and satisfactorily. Such increase shall in no case<br />
invalidate the contract rates. It shall be definitely understood that the<br />
Corporation does not accept any responsibility for the correctness or<br />
completeness of the quantities shown in the schedule. The schedule is liable to<br />
alteration by omissions or additions or deductions and such omissions/ deductions<br />
CONTRACTOR<br />
4<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
5<br />
shall in no case invalidate the contract and no extra monetary compensation will be<br />
entertained.<br />
15 Engineer contractors desirous to avail the facility of exemption of EMD are<br />
required to submit affidavit to the effect that he/she has not yet availed this<br />
facility for more than two works during the current financial year. The name of<br />
work for which and the authority to whom the tenders have been submitted, must<br />
be mentioned in the affidavit failing which the tender will be rejected. Exemption<br />
of EMD will be entered in the original Registration Certificate of the Engineer<br />
Contractor at the time of participating in the tender. Hence the Engineer<br />
Contractor or his authorized representative has to produce the original license for<br />
necessary entry within 2 days of opening of the tender.<br />
16 The agency should produce work experience of the similar nature of the work and<br />
produce the certificate regarding completion of similar works during the last five<br />
financial years.<br />
17 The agency should use all building materials such as reinforcement, sand etc. free<br />
from corrosion/corrosive materials etc. No extra payment will be made for such<br />
purpose by O.T.D.C. Ltd.<br />
18 Orissa Detailed Standard Specification will be followed during execution of work.<br />
19 All materials including those issued direct to the work will be received by the<br />
contractor from the respective Store of the Corporation in the sizes as per<br />
availability of stock. After issue, it will be the contractor's responsibility for<br />
transportation, storage, handling, safe custody and proper upkeepment of<br />
materials. The rate of the contractor should include all the incidental charges<br />
required after the issue of material from Corporation store till its utilisation in<br />
the work and return of surplus and good materials at the issuing store.<br />
The contractor will have to bear the cost of straightening, cutting, jointing,<br />
welding etc. of all steel reinforcement and structural and no cut pieces less than<br />
1(one) meter length will be accepted. After completion of the work the contractor<br />
has to return all surplus and good materials at the issuing store at his own cost<br />
failing which the cost of the unutilized balance Corporation materials and such<br />
other damaged materials not receptacle to the Corporation would be recovered<br />
from him at 5 (five) times the stock issue rates.<br />
20 All reinforced cement concrete work should conform to Orissa Detailed Standard<br />
Specification and should be of grade M-150/200 with 12mm. Size black hard<br />
crusher broken granite stone chips (20mm. Size not to exceed 25%) having a<br />
minimum compressive strength (in work test) 150kg/200kg/cm 2 in 15 cm. cubes at<br />
28 days after mixing and tests conducted in accordance with IS 456 and IS 516.<br />
21 Shuttering and centering shall be with seasoned Sal wood planks the inside of<br />
which shall be lined with suitable sheeting and made leak-proof and water tight or<br />
alternatively steel shuttering and centering may be used.<br />
22 The selected contractor may take delivery of supply of materials according to his<br />
need for the work issued by the Engineer-in-charge of the work. The contractor<br />
shall make all arrangements for proper storage of materials. But no cost for<br />
raising shed for the storage of materials and pay of watchmen etc. will be borne<br />
by the Corporation. These are all to be borne by the Contractor. The Corporation<br />
CONTRACTOR<br />
5<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
6<br />
is not responsible for considering the theft of materials at site. It is<br />
contractor's risk. Under any such plea if the contractor stops the work he shall<br />
have to pay the penalty as per the clauses of the contract.<br />
23 For the purpose of jurisdiction in the event of dispute if any contract should be<br />
deemed to have entered into within the State of Orissa and it is agreed that,<br />
neither party to the contract nor the agreement will be competent to bring a suit<br />
in regard to the matters covered by this contract at any place outside the State<br />
of Orissa.<br />
24 After the work is finished, all surplus materials and debris are to be removed by<br />
the contractor and preliminary works such as vats, mixing platforms, etc. are to be<br />
dismantled and all the materials are to be removed from the site. No extra<br />
payment will be made to the contractor on this account. The rate quoted should<br />
be inclusive of all these items. The ground upto 15 meter shall be cleared and<br />
rough dressed.<br />
25 The contractor shall not interfere with the execution of water supply or electrical<br />
fittings arrangements and any other works entrusted to any other agency by the<br />
Corporation at any time during the progress of work.<br />
26 The Corporation will have the right to inspect the scaffolding and centering made<br />
for the work and can reject partly or fully such structures if found defective in<br />
their opinion.<br />
27 The Contractor will have to arrange for water supply for all works and made<br />
sanitary arrangements at his own cost for his Labour camps. The contractor has<br />
to arrange adequate lighting arrangements for night works whenever necessary at<br />
his own cost.<br />
28 Bailing out water from the foundation either rain water or sub-soil water if<br />
necessary should be borne by the contractor. No payment will be made for<br />
benchmarks, level pillars profiles and benching and leveling ground where required.<br />
The rates quoted should be for finished items of work inclusive of these incidental<br />
items of work.<br />
29 All the quantities mentioned in the schedule are combined for ground floor and<br />
multi-floors in case of multistoried building and the rates should be through for<br />
the same.<br />
30 Cement concrete in roof slabs, beams and wherever prescribed by the Engineer-incharge<br />
shall be machine mixed and vibrated, and the contractor should arrange his<br />
own concrete mixers, vibrators, and pumps etc. for the purpose.<br />
31 It should be understood clearly that no claims whatsoever will be entertained.<br />
32 The tenderer shall have to abide by the C.P.W. Safety Code introduced by the<br />
Govt. of India, Ministry of Works, Housing and Supply in their standing orders<br />
No.44250 dt.25.11.57.<br />
33 The contractor will abide by the Fair Wages clause as introduced by the<br />
Government.<br />
34 The Corporation have the right to supply at any time in the interest of work any<br />
Corporation materials to be used in the work in addition to those mentioned in the<br />
clause 13 and the contractor shall use such materials without any controversy or<br />
CONTRACTOR<br />
6<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
7<br />
dispute on that account. The rates of the materials will be at the stock issue<br />
rates fixed by the Corporation or market rates whichever is higher.<br />
35 The contractor will be responsible for the loss or damage if any of Corporation<br />
materials supplied to him under clauses 13 and 30 during execution of the work<br />
due to reasons whatsoever and the cost of such materials will be recovered from<br />
him at the prevailing stock issue rates or market rates whichever is higher.<br />
36 CONTRACTOR'S TOOLS & PLANT AND SUPPLY OF DEPARTMENTAL TOOLS &<br />
PLAT TO CONTRACTORS.<br />
The contractor should arrange at his own cost necessary tools and plant such as<br />
Pumps, Vibrator, Concrete mixer etc. required for the efficient execution of the<br />
work and rates quoted should be inclusive of the running charges of such plant and<br />
cost of consumables.<br />
37 The contractor will have to submit to the Sr.Divisional Manager (BP)-I, O.T.D.C.<br />
Ltd. monthly return of labour both skilled & un-skilled employed by him on the<br />
work.<br />
38 The tenderers are required to go through each clause of Corporation contract<br />
form carefully in addition to clauses mentioned herewith before tendering.<br />
39 No part of the contract shall be sublet without written permission of the<br />
Sr.Divisional Manager (BP)-I O.T.D.C.Ltd., Bhubaneswar or transfer be made by<br />
power of attorney authorising others to receive payment on the contractor's<br />
behalf.<br />
40 No tender documents will be sold to the intending, tenderers after the last date<br />
stipulated for selling of Tender papers.<br />
41 If any further necessary information is required, Sr.Divisional Manager (BP)-I,<br />
O.T.D.C. Ltd., Bhubaneswar will furnish such but it must be clearly understood that<br />
tenders must be received in order and according to the instructions.<br />
42 Bags and weight of one cubic metre of cement being taken, as 14.42 quintals.<br />
43 In the event of any delay in the supply of Departmental materials or supply of<br />
detailed structural designs for unavoidable reasons, reasonable extension of time<br />
will be granted on the application of the contractor. But no claim for monetary<br />
compensation will be entertained under any circumstances.<br />
44 No contractors will be permitted to furnish their tender in their own manuscript<br />
papers.<br />
45 SAMPLE OF MATERIALS:<br />
Every tenderer is expected before quoting his rates to inspect the site of<br />
proposed work. He should also inspect the quarries and satisfy himself about the<br />
quality, availability of materials, medical aids, labour and foodstuffs etc. and the<br />
rates may be inclusive of all these items of work. In every case the materials must<br />
comply with the relevant specification and samples of materials in sealed bag may<br />
be submitted along with the tender for approval of the Sr.Divisional Manager (BP),<br />
O.T.D.C.Ltd.<br />
46 O.T.D.C.Ltd. Will not however, after acceptance of contract rate, pay any extra<br />
charges for lead or for any other reason in case the contractor is found later on<br />
to have mis-judged the materials available.<br />
CONTRACTOR<br />
7<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
8<br />
47 All fittings for doors and windows if supplied by the Contractor should be of best<br />
quality and should be got approved by the Engineer-in-charge before they are used<br />
on the work<br />
48 EXTRANEOUS CONDITION:<br />
The tenders containing extraneous conditions not covered by the tender call notice<br />
are liable for rejection.<br />
49 VALIDITY<br />
All tenders received will remain valid for a period of ninety days from the date of<br />
receipt of tenders and validity of tender can also be extended if agreed to by the<br />
contractor and the Corporation.<br />
50 After completion of the work the contractor shall arrange at his own cost all<br />
requisite equipments for testing building if found necessary and bear the entire<br />
cost of such test.<br />
51 LIST OF WORKS IN HAND, T & P & WORK EXECUTED:<br />
Tenderers are required to submit, (i) list of works in the hand in the following<br />
prescribed proforma 'A', (ii) list of works executed in the prescribed proforma 'B'<br />
and (iii) the list of T & P in the prescribed proforma 'C' along with the tenders.<br />
52 Letters etc. found in the tender box, raising or lowering rates or dealing with any<br />
point in connection with the tender will not be considered.<br />
53 All reinforced cement concrete works should be finished smooth, Extra charges<br />
for plastering if required to any R.C.C. structures like columns, beams, chajjas etc.<br />
shall not be paid.<br />
54 2% of the gross amount of bill will be deducted towards income tax from the<br />
contractor’s bill. Also 4% of the gross amount of the bill will be deducted towards<br />
Sales Tax for all contracts costing Rs.1.00 lakh & more. This will vary as per<br />
prevailing Govt. orders from time to time.<br />
55 1% of the gross amount of bill will be deducted towards CESS from the<br />
contractor’s bill under the Building and other construction worker’s(RE&CS)<br />
Act 1996 vide Lt. NO: 12653 dated 15 th December,2008 of labour<br />
&Employment Dept. Govt. of Orissa.<br />
PROFORMA-'C'<br />
CERTIFICATE OF TOOLS AND PLANTS<br />
I/We hereby certify that the following tools and plants, machineries and vehicles<br />
are in my/our possession in working orders.<br />
i.<br />
ii.<br />
iii.<br />
iv.<br />
v.<br />
I/We also note that, non-submission of this certificate will render my/our tender<br />
liable for rejection.<br />
CONTRACTOR<br />
8<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
9<br />
Signature of the tenderer<br />
Date_______________<br />
56 The tenderer shall bear cost of various incidental sundries and contingencies<br />
necessitated by the works falling within the following or similar category.<br />
(a) Rent, royalties and other charges of materials, Octroi duty, all other taxes<br />
including sales tax, ferry tolls, conveyance charges and other costs on<br />
account of land and buildings including temporary buildings required by the<br />
tenderer for collection of materials, storage, housing of staff or other<br />
purpose of the work. No rent however be payable to Corporation for<br />
temporary occupation of land owned by the Corporation at the site of the<br />
work.<br />
(b) Labour camps and huts necessary to a suitable scale including conservancy<br />
and sanitary arrangements thereon to the satisfaction of the local health<br />
authorities.<br />
(c) Suitable water supply including pipe water supply wherever available for the<br />
staff and labourers for the works.<br />
(d) Fees and dues hired by Municipal, Canal and water supply authorities.<br />
(e) Suitable equipments and wearing apparatus for the labourers engaged in<br />
risky operation.<br />
(f) Suitable fencing barriers, signal including paraffin and electrical signal<br />
where necessary at works and approaches in order to protect the public and<br />
employees from accidents.<br />
(g) Compensation including cost of any suit for injury to person or property due<br />
to neglect of any major precautions also sums which may become payable<br />
due to operation of workmen's Compensation Act.<br />
(h) The contractor has to arrange adequate lighting arrangement for night<br />
works wherever necessary at his own cost.<br />
(i) The contractor has to arrange all the building materials including the<br />
equipments required for under reamed pile foundation for starting the work.<br />
57 INTEREST:<br />
Under no circumstances interest is chargeable for the dues or additional dues if<br />
any payable for the work.<br />
58 Special class contractor shall employ under him one Graduate Engineer and two<br />
Diploma Holders belonging to the State of Orissa, like wise 'A' class contractor<br />
shall employ under him one Graduate Engineer or two Diploma Holder belonging to<br />
the State of Orissa. The employment of such Graduate Engineer and Diploma<br />
Holders under the contractor shall be full-time and continuous and they shall not<br />
be superannuated, retired, dismissed or removed personnel from any state Govt.<br />
or Central Govt. service/Public Sector undertaking/Private companies and firms or<br />
be ineligible for appointment to Govt. service. The contractor shall pay them<br />
monthly emoluments, which shall not be less than the emoluments of the personnel<br />
of equivalent qualification employed under the State Govt. of Orissa. The<br />
Sr.Divisional Manager, Building Project may however, assist the contractor with<br />
names of such un-employed Graduate Engineers and Diploma Holders if such help is<br />
sought for by the Contractor.<br />
CONTRACTOR<br />
9<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
10<br />
59 The name of such Engineer personnel appointed by the Contractor should be<br />
intimated to the tender receiving authority along with each tender, as to who would<br />
be supervising the work.<br />
60 Each bill of the Special Class or 'A' class contractor shall be accompanied by an<br />
Employment Roll of the Engineering personnel together with a certificate of the<br />
Graduate Engineer or Diploma Holder so employed by the contractor to the effect<br />
that the work executed as per the bill has been supervised by him. A prescribed<br />
proforma is enclosed herewith for furnishing the required certificate there in<br />
under this clause.<br />
61. He sealed cover should be super-scribed with the material of contents.<br />
62 His quantity/volume of item may alter during construction as per field condition.<br />
63. Wherever there is ambiguity or missing data, the work shall be done as per the<br />
direction of the Engineer-in-charge.<br />
64. The colour of the pole should match with that of the luminary.<br />
65. The interested bidders may visit the site and should be acquainted themselves with<br />
the field activities to be experienced during construction.<br />
66. The delay if any due to other departments such as digging on road etc. shall be the<br />
responsibility of the successful bidder.<br />
67. Separate sheets may be attached if the space is not sufficient in the tender paper.<br />
68 The bidder shall possess electrical license from ELBO, Orissa.<br />
69 Statutory clearance if any from electrical inspector shall be the responsibility of<br />
the successful bidder.<br />
70 Wherever the items appear with a sign (/) both rates shall be quoted.<br />
71 The Contractor shall have to furnish an affidavit about the authentication of<br />
tender documents including bank guarantee at the time of submission of Tender<br />
paper.<br />
Total 71 (seventy One) clauses only.<br />
Sr. Divisional Manager<br />
(Building Project)-I<br />
O.T.D.C. Ltd.<br />
CONTRACTOR<br />
10<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
QUALITY CONTROL REQUIREMENTS<br />
1.0 Earth work<br />
1.1. Density requirements for embankments and sub-grade materials. MoRTH<br />
Specification (4 th Revision).<br />
Sl.<br />
No.<br />
Type of work<br />
11<br />
Maximum dry density at<br />
OMC (IS:2720 Part-8)<br />
1. Embankment upto 3m height not subjected to<br />
extensive flooding<br />
2. Embankment exceeding 3m height or embankment<br />
subjected or embankment subjected to long periods<br />
of inundation.<br />
Minimum 15.2kN/m 3<br />
Minimum 16kN/m 3<br />
3. Subgrade and earthen shoulder and back fill. Minimum 17.5kN/m 3<br />
1.2. Compaction requirement for embankment and sub-grade.<br />
Sl.<br />
No.<br />
Type of work<br />
Percentage of<br />
Compaction at OMC<br />
1. Sub-grade and shoulder Minimum 97%<br />
2. Embankment Minimum 95%<br />
3. Expansive clay<br />
a. Sub-grade Not allowed<br />
b. Remaining portion Minimum 90%<br />
1.3. Criteria for small embankment (dams) (IS : 12169)<br />
The general guidelines for embankment sections are furnished in Table No.-1.<br />
TABLE-4<br />
(GENERAL GUIDELINES FOR EMBANKMENT SECTIONS)<br />
SL.<br />
NO.<br />
DESCRIPTION<br />
HEIGHT UPTO<br />
5m<br />
1. Type of section Homogeneous<br />
Modified<br />
homogeneous<br />
section<br />
Ii Slopes U/S U/S<br />
a. Coarse grained soil<br />
(GW, GP, SW, SP)<br />
(H:V)<br />
(H:V)<br />
HT. ABOVE 5M<br />
AND UPTO 10m<br />
Zoned section/<br />
Modified<br />
homogeneous<br />
section/<br />
homogeneous<br />
section<br />
U/S<br />
(H:V)<br />
D/S<br />
(H:V)<br />
HT. ABOVE 10M AND<br />
UPTO 15m<br />
Zoned section/ modified<br />
homogeneous section/<br />
homogenous section<br />
U/S<br />
D/S<br />
Not suitable Not suitable Not suitable for core.<br />
Suitable for casing zone.<br />
CONTRACTOR<br />
11<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
. Coarse grained soil<br />
(GW,GP, SW, SP)<br />
c. Fine grained soil (Cl,<br />
ML, Cl, Ml)<br />
d. Fine grained Soil<br />
(CH, MH)<br />
12<br />
2:1 2:1 2:1 2:1 Section to be decided<br />
based upon the stability<br />
analysis in accordance with<br />
IS: 7894-1975.<br />
2:1 2:1 25:1 2251:1 -do-<br />
2:1 2:1 3.75:1 25:1 may<br />
be provided<br />
a. Top width -- 3m 3m<br />
Necessary<br />
b. Top level -- 0.5m above MWL 0.5m above MWL<br />
Iv Rock toe height Not necessary<br />
upto 3m above<br />
3m ht, 1m, ht of<br />
rock toe may be<br />
provided<br />
Necessary H/5,<br />
where H is the<br />
height of the<br />
embankment.<br />
Necessary H/5, where H is<br />
the height of the embkt.<br />
v. Berms Not necessary Not necessary The berm may be provided<br />
as per design. The min.<br />
berm width shall be 3m.<br />
The berm may be provided<br />
also on the D/S slope for<br />
facilities<br />
during<br />
maintenance.<br />
1.4. Criteria for small embankments (dams) : (IS : 12169)<br />
The general guidelines regarding suitability of soil for construction of dams are<br />
furnished in table No. 2.<br />
Relative<br />
suitability<br />
Table – 2<br />
Suitability of soil for construction of dams.<br />
Homogeneous<br />
Dykes<br />
Zone dam<br />
Impervious cure<br />
Pervisou casing<br />
Very GC GC SW,GW GC<br />
Suitable<br />
Suitable CL, Cl Cl, Cl GM CL,Cl<br />
Impervious<br />
blanket<br />
Fairly suitable SP, SM, CH GM, GC, SM, SC, CH SP, GP CH, SM, SC, GC<br />
Poor<br />
Not suitable<br />
Ml, Ml, MH<br />
OLOl, OH, Pt<br />
1.5. Frequency of test<br />
Table-3<br />
Sl. Test Designation Frequency of test as Frequency of test of ODR & VR<br />
CONTRACTOR<br />
12<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
13<br />
No. per MoRTH as recommended by IRC-SP-20<br />
1. Mechanical analysis of<br />
soil<br />
2 tests/3000m 3<br />
2. Plastic of soil 2 tests/3000m 3<br />
3. Density test of soil 2 tests/3000m 3<br />
4. Deleterious content As & when required<br />
5. Moisture content of<br />
soil<br />
6. CBR test of soil 1 tests/3000m 3 or<br />
more<br />
7. Compaction test of soil<br />
for each layer<br />
1 tests/250m 3 2-3 tests per 250m 3 of loose soil<br />
5-10 tests/1000m 3 5-10 tests per 1000m 3<br />
Note : CBR of sub-grade should not be less than 2%<br />
MoRTH- Ministry of road transport and highways<br />
Table-7<br />
E.W. COMPACTION : The information given should be taken only as an approximate<br />
guide<br />
Materi<br />
al<br />
Major<br />
Division<br />
Sub-groups<br />
Suitable<br />
type of<br />
compacting<br />
equipment<br />
No. of<br />
passes<br />
for<br />
satisfact<br />
ory<br />
compactio<br />
n (Min.)<br />
Thicknes<br />
s of<br />
loose<br />
layer<br />
(Actual<br />
thicknes<br />
s<br />
depends<br />
on plant<br />
used),<br />
Max cm.<br />
Remarks<br />
1 2 3 4 5 6 7<br />
Coarse<br />
grained<br />
soil and<br />
other<br />
materia<br />
ls<br />
Gravel and<br />
gravelly soils<br />
Well-graded<br />
gravel, gravels<br />
and mixtures,<br />
little or no<br />
fines<br />
Well-graded<br />
gravel sand<br />
mixtures with<br />
excellent clay<br />
blinder<br />
uniform gravel<br />
with little or<br />
no fines poorly<br />
graded gravel<br />
Smoothwheel<br />
roller<br />
pneumatictyred<br />
roller<br />
vibrating<br />
smooth<br />
wheel<br />
roller<br />
heavy<br />
bivrating<br />
plate frogrammer<br />
6<br />
6<br />
6<br />
2*<br />
3**<br />
20<br />
20<br />
20<br />
37.5<br />
37.5<br />
20<br />
Vibrating rollers<br />
or vibrators will<br />
be very<br />
satisfactory if<br />
the moisture<br />
conent of the soil<br />
is low, but may be<br />
uneconomical<br />
close moisture<br />
content control is<br />
essential when<br />
the moisture<br />
content is<br />
relatively high it<br />
CONTRACTOR<br />
13<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
Fine<br />
grained<br />
soils<br />
CONTRACTOR<br />
Soils having<br />
low<br />
compressibili<br />
ty<br />
Soils having<br />
high<br />
compressibili<br />
ty<br />
Fibrous<br />
organic soils<br />
and gravel sand<br />
mixtures little<br />
or no fines<br />
Gravel with<br />
fines. Silty<br />
gravel, clayey<br />
gravel, poorlygraded<br />
gravelsand-clay<br />
mixtures<br />
Well grained<br />
sands and<br />
gravelly sands,<br />
little or no<br />
fines<br />
Uniform sands<br />
with little or<br />
no fines silts<br />
(inorganic) and<br />
very fine<br />
sands, rock<br />
flour, silty or<br />
clayey fine<br />
sands, with<br />
slight<br />
plasticity. Silty<br />
and sandy clays<br />
(inorganic or<br />
medium<br />
plasticity.<br />
Clays<br />
(inorganic) or<br />
medium<br />
plasticity.<br />
Micaceous or<br />
distomaccous<br />
fine sandy and<br />
silty soils,<br />
elastic silts<br />
14<br />
Well-graded<br />
sand with<br />
excellent claybinder<br />
powerrammer<br />
Smooth<br />
wheel<br />
roller<br />
pneumatic<br />
tyred<br />
roller<br />
track<br />
laying<br />
tractor<br />
sheep foot<br />
roller frog<br />
rammer<br />
power<br />
rammer.<br />
14<br />
4<br />
--<br />
10<br />
30<br />
2*<br />
2*<br />
20<br />
Sr.DIVISIONAL MANAGER (B.P.)-I<br />
--<br />
15<br />
15<br />
37.5<br />
20<br />
is preferably to<br />
use a pneumatic<br />
tyred roller<br />
--<br />
--<br />
These soils are<br />
considered very<br />
undesirable for<br />
use in earthwork<br />
and should not be<br />
employed if they<br />
are highly<br />
compressible it is<br />
advisable to<br />
compact these<br />
soils at the<br />
moisture content<br />
at which no<br />
change will occur<br />
subsequently<br />
As for micaceious<br />
or distomaceous<br />
fine sandy and<br />
silty soils these
15<br />
with very<br />
high<br />
compressibili<br />
ty<br />
Clays<br />
(inorganic) or<br />
high plasticity,<br />
fat clays<br />
soils are entirely<br />
unsuitable for<br />
earthwork<br />
construction.<br />
Organic clays<br />
of high<br />
plasticity pest<br />
and other<br />
highly organic<br />
swamp soils.<br />
5. Materials for cement concrete :<br />
This includes the I.S. specification of the materials such as cement, coarse and fine<br />
aggregate, water, and reinforcement. For details respective I.S. specification may be<br />
referred to.<br />
5.1. Fine aggregate : IS 383<br />
5.1.1. Zoning: The fine aggregates suitable for concrete shall be in zone-I, II or III.<br />
Fine aggregate in zone-IV are not suitable for concrete. The zone can be<br />
decided by grain size analysis by sieving as follows.<br />
Table-21 (IS-383-Table No.-4)<br />
IS Sieve<br />
Designation<br />
Grading Zone-<br />
I<br />
Percentage passing for<br />
Grading Zone-<br />
II<br />
Grading Zone-<br />
III<br />
Grading Zone-<br />
IV<br />
10m. 100 100 100 100<br />
4.75mm 90-100 90-100 90-100 95-100<br />
2.36mm 60-95 75-100 85-100 95-100<br />
1.18mm 30-70 55-90 75-100 90-100<br />
600 micron 15-34 35-59 60-79 80-100<br />
300 micron 5-20 8-30 12-40 15-50<br />
150 micron 0-10 0-10 0-10 0-15<br />
5.1.2. Bulkage :- Maximum buklage shall be limited to 20%<br />
5.2. Quality of coarse aggregates:<br />
5.2.1. Crushing value Permissible Value Method of test<br />
a. All concrete woks<br />
except wearing surface.<br />
Maximum 45% IS 2386-1963 part –<br />
IV<br />
b For wearing surface -do- 30% -do-<br />
5.2.2. Impact value Permissible Limit Method of test<br />
a. All concrete woks Maximum 45% IS 2386-1963 part –<br />
CONTRACTOR<br />
15<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
16<br />
except wearing surface.<br />
IV<br />
b For wearing surface -do- 30% -do-<br />
5.2.3. Abrasion value<br />
a. All concrete woks<br />
except wearing surface.<br />
Maximum 50% -do-<br />
b For wearing surface -do- 30% -do-<br />
5.2.4. Deleterious materials : Maximum percentage shall be 5%.<br />
5.2.5. Alkali aggregate reaction:- It is harmful for concrete. The test shall be conducted<br />
and use of pozzolanic cement or pozzolanic admixture shall be studied.<br />
5.2.6. Gradation of coarse aggregate of nominal size:<br />
Table-22<br />
IS Sieve (mm)<br />
Percentage passing for graded aggregates of nominal size<br />
40 20 15 12.5<br />
80 100 -- -- --<br />
40 95-100 100 -- --<br />
20 30-70 95-100 100 100<br />
16 -- -- 90-100 --<br />
12.5 -- -- -- 90-100<br />
10 10.35 25.55 30.70 40-85<br />
4.75 0-5 0-10 0-10 0-10<br />
2.36 -- -- -- --<br />
5.3. Cement : The normal type of cement used are :<br />
1. Ordinary Portland cement 33 grade, 43 grade, 53 grade conforming to IS: 269,<br />
IS:8112 & IS:12269 respectively.<br />
2. Port land slag cement IS: 544<br />
3. Port land pozzolana cement I.S : 1489<br />
5.3.1. Standard of physical test of cement<br />
a. Initial setting time - minimum 30 minutes<br />
b. Final setting time - Maximum 10 hrs.<br />
c. Fineness - (i) 225 (m 2 /kg) for OPC & PSC<br />
(ii) 300 (m 2 /kg) for PPC<br />
d. Soundness - a. 10mm maximum (Lechat expansion)<br />
b. Maximum 0.8% in Autoclave<br />
e. Compressive Strength :<br />
Time<br />
33 grade OPC,<br />
PSC, PPC<br />
43 grade OPC 53 grade OPC<br />
CONTRACTOR<br />
16<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
17<br />
a. 72 hrs. 16MP 2 23MP 2 27MP 2<br />
b. 7 days 22MP 2 33MP 2 37MP 2<br />
c. 28 days 33MP 2 43MP 2 53MP 2<br />
5.3.2. Standards for chemical test :<br />
Table – 23<br />
Percentage by mass (Max.)<br />
Types of cement OPC PPC PSC Remarks<br />
33 43 53<br />
1. Magnesia 6 6 6 6 8<br />
2. Insoluble residue 4 2 2 x+4(100-x)<br />
100<br />
4 Where x=% of<br />
pozollana in cement<br />
3. Sulphur trioxide 2.5d 2.5d 2.5d 3 3 Where d-3% when<br />
C,A>5%<br />
4. Sulphur as sulphide -- -- -- -- 1.5<br />
5. Loss on ignition 5 5 4 5 5<br />
6. Chloride 0.5 0.05 0.05 -- -- Maximum for prestressed<br />
and long<br />
span structures<br />
5.4. Water :<br />
Normal potable water shall be used for concrete. The pH value shall be not less than 6.<br />
Permissible limits of solids – I.S. :3025.<br />
Organic - 2000mg/litre<br />
Chloride - 2000mg/litre<br />
Inorganic - 3000mg/litre<br />
Sulphate - 400 mg/litre<br />
Suspended matter - 2000mg/litre<br />
5.5. Reinforcement steel :<br />
The normal reinforcement steel bars may be mild and medium tensile steel bars or high<br />
strength deformed steel bars conforming to I.S.-432 and IS:1786 respectively. The<br />
limits of physical and chemicals properties of deformed bar.<br />
a. Mechanical properties<br />
Sl.<br />
No.<br />
Table – 24 (IS : 1786, Table No.-3)<br />
Property F 3 415 Grade F c 500 F e 550<br />
1 2 3 4 5<br />
1 0.2% proof stress/yield<br />
stress, Min, N.mm 2 415.0 500.0 550.0<br />
2. Elongation, percent, Min,<br />
on gauge length 5.56 v(A),<br />
14.5 12.0 8.0<br />
CONTRACTOR<br />
17<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
18<br />
where A is the cross<br />
sectional area of the test<br />
piece.<br />
8% more than the<br />
3. Tensile strength, Min 10%more than<br />
485.0 N/mm 2<br />
the actual 0.2%<br />
proof stress but<br />
not less than<br />
actual 0.2% proof<br />
stress but not less<br />
than 545.0 N/mm 2<br />
6% more than the<br />
actual 0.2% proof<br />
stress but not less<br />
than 585.0 N/mm 2<br />
b. Chemical properties :<br />
Constituent<br />
Table – 24 (IS : 1786)<br />
Percent, maximum<br />
F e 415 F e 500 F e 550<br />
Carbon 0.30 0.30 0.30<br />
Sulphur 0.060 0.055 0.055<br />
Phosphorous 0.060 0.055 0.050<br />
Sulphur and phosphorous 0.11 0.105 0.10<br />
c. Frequency of test (IS : 1786)<br />
One test of each type of MS rod to be used in each structure.<br />
d. Pull out test : As per IS:2770<br />
e. Bend and rebend test : IS : 1786.<br />
f. Mass and cross sectional area (IS : 1786).<br />
Nominal size (mm) Sectional area (mm 2 ) Mass per meter (kg)<br />
6 28.3 0.222<br />
8 50.3 0.395<br />
10 78.6 0.617<br />
12 113.1 0.888<br />
16 201.2 1.580<br />
20 314.3 2.47<br />
25 491.1 3.85<br />
28 616.0 4.83<br />
32 804.6 6.31<br />
5.6. Construction joints :<br />
The concreting shall be done up to construction joints, but while commencing the<br />
work on the cold joints, the aggregates shall be exposed with high pressure water jet or<br />
CONTRACTOR<br />
18<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
19<br />
any other method. It is preferable to expose the aggregates previously i.e. just after the<br />
closer of the work by wire brushing and cleaning. Cleaning may be done be by air water<br />
jetting or any other method.<br />
6. Concrete works.<br />
6.1. Grade of concrete<br />
The grade designation shall be as follows.<br />
a. Ordinary concrete M10, M15 & M20<br />
b. Standard concrete M25, M30, M35, M40, M45, M50 & M55<br />
c. High strength concrete M60, M65, M70, M75 & M80<br />
d. Concrete exposed to seawater shall be at least M20 & M30 for P.C.C. & R.C.C.<br />
respectively. The use of slag or pozzolana cement is advantageous under such<br />
conditions.<br />
6.2. Workability of concrete<br />
Table –26<br />
Placing conditions<br />
Binding concrete; shallow sections; pavements<br />
using lavers;<br />
Mass concrete; lightly reinforced sections in<br />
slabs, beams, walls, columns; floors; hand<br />
placed pavements; canal lining; strip footings.<br />
Degree of<br />
workability<br />
Slump (mm)<br />
1 2 3<br />
Heavily reinforced sections in slabs, beams,<br />
walls, columns; slipfonn work; pumped concrete<br />
Trench fill;<br />
In-situ pilling<br />
Very low<br />
Low 25-75<br />
Medium 50-100<br />
Compacting factor from<br />
0.75 to 0.8 is suggested<br />
75-10<br />
High 100-150<br />
Tremie concrete; Very high Refer IS :9103<br />
Note : For most of the placing conditions, internal vibrators (neddle vibrators) are<br />
suitable. The diameter of the needle shall be determined based on the density and spacing<br />
of reinforcement bars and thickness of sections. For tremie concrete, vibrators are not<br />
required to be used.<br />
6.3. Mild : Concrete surfaces protected against weather or aggressive conditions<br />
except those situated in coastal area.<br />
6.3.2. Moderate : Concrete surfaces sheltered from severe rain or freezing whilst wet.<br />
Concrete exposed to condensation and rain.<br />
Concrete continuously under water.<br />
Concrete in contact of buried under non-aggressive soils/ ground water.<br />
Concrete surfaces sheltered from saturated salt air in coastal area.<br />
6.3.3. Severe : Concrete surfaces exposed to severe rain, alternate wetting and drying or<br />
occasional freezing whilst wet or severe condensation. Concrete complitely<br />
immersed in sea water concrete expose to coastal environment.<br />
CONTRACTOR<br />
19<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
20<br />
6.3.4. Very severe : Concrete surfaces exposed to sea water spray, corrosive fumes or<br />
severe freezing conditions whiles wet.<br />
Concrete incontact with or buried under aggressive sub-soil/ ground water.<br />
6.3.5. Extreme : Surface of members in tidal zone.<br />
Members indirect contact with liquid / solid aggressive chemicals.<br />
Exposure a.PCC<br />
Minimum W/C grade<br />
Cement<br />
ratio<br />
Content<br />
maximum<br />
Kg/(m 3 )<br />
Mild 220 0.6 --<br />
Moderate 240 0.6 M15<br />
Severe 250 0.50 M20<br />
Very severe 260 0.45 M20<br />
Extreme 280 0.40 M25<br />
b.PCC<br />
Mild 300 0.55 M20<br />
Moderate 300 0.50 M25<br />
Severe 320 0.45 M30<br />
Very severe 340 0.45 M35<br />
Extreme 360 0.40 M40<br />
6.4. Nominal mix concrete<br />
The nominal mix concrete may be used for concrete of M20 grade and lower as per the<br />
table below:<br />
Grade of concrete<br />
Total qty. of dry<br />
aggregate for<br />
50kg of cement in<br />
kg<br />
Table – 27<br />
Proportion of fine<br />
to coarse<br />
aggregate by mass<br />
Max. qty. of<br />
water per 50kg of<br />
cement in litre<br />
M5 800 Generally 60<br />
M 7.5 625 1:2 45<br />
M10 480 -- 34<br />
M15 330 -- 32<br />
M20 250 -- 30<br />
6.5. Design Mix : Ref. IS : 10262<br />
6.6. Placing : The concrete shall be placed and compacted before initial setting time of<br />
cement.<br />
6.7. Curing : The period for moisture curing shall be minimum 10 days. It may be<br />
extended upto 28 days.<br />
6.8. Stripping time : Following stripping time may followed.<br />
Type of form work<br />
Minimum period before striking form<br />
CONTRACTOR<br />
20<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
21<br />
a. Vertical 16-25 h<br />
b. Soffit form work to slab 3 days<br />
c. Soffit form work to beam 7 days<br />
d. Props to slab<br />
(i) Spanning upto 4.5m<br />
(ii) Spanning over 4.5m<br />
7 days<br />
14 days<br />
work.<br />
6.9 Nominal cover:<br />
Cover to be provided depending on exposure condition.<br />
Exposure<br />
Cover in mm<br />
Mild 20<br />
Moderate 30<br />
Sever 45<br />
6.9. Frequency of sampling : Depending on quantity of work, number of samples are to<br />
be taken.<br />
Qty. in m 3 No. of samples<br />
1-5 1 Set<br />
6-15 2 Set<br />
16-30 3 Set<br />
31-50 4 Set<br />
51 to above 4 plus one additional<br />
set for each 50m 3 or part.<br />
(one set= 6 Nos. of samples)<br />
6.10. Concrete works :<br />
Sl.<br />
No.<br />
A. Coarse aggregate<br />
Test<br />
Table – 28<br />
1. Sieve analysis flakiness and elongation<br />
index<br />
2. Specific gravity, bulk density, moisture<br />
content and absorption.<br />
Frequency as per MoRTH<br />
One test for every 150m 3 or less<br />
-do-<br />
3. Soundness -do-<br />
4. Abrasion, impact, aggregate crushing value -do-<br />
5. Organic impurities value<br />
6. Alkali-aggregate reactivity Twice in one season<br />
7. Petro-graphic test -do-<br />
B. Fine Aggregates<br />
1. Sieve analysis One test for every 1.50m 3 of sand<br />
CONTRACTOR<br />
21<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
2. Organic impurities -do-<br />
3. Soundness -do-<br />
22<br />
4. Sp. Gravity, moisture contents and<br />
absorption<br />
C. Cement<br />
1. Fineness One test for each brand and batch of cement<br />
-do-<br />
2. Setting time -do-<br />
3. Compressive strength<br />
D. Finished concrete<br />
1. Slump test One test for each shift both at mixer and at<br />
placement site. As frequently as possible.<br />
2. Compressive strength -do-<br />
3. Cement content One test every 3 months<br />
6.12 Aceptance criteria for concrete (IS : 456-2000, clause-16):<br />
The concrete shall be deemed to comply with the strength requirements when both the<br />
following conditions are met.<br />
a. The mean strength determined from any group of four consecutive tests<br />
results shall satisfy the following conditions.<br />
(i) Mean strength :<br />
a. For M 13 grade : f a + 0.825 x established standard deviation<br />
(rounded to 0.5) N/mm 2<br />
OR<br />
Fa + 3N/mm 2 (which ever is greater).<br />
b. For M 20 grade : Mean strengthf a + 0.825 standard<br />
or above deviation (rounded to nearest 0.5) N/mm 2<br />
OR<br />
F a + 4N/mm 2 (which ever is greater).<br />
In absence of data for SD, the SD may be taken 3.5 for M 10 and M 15 grade, 4 for M 20 and<br />
M 25 grade and 5 for M 30 to M 50 grade.<br />
b. Individual test results :<br />
For M 13 grade<br />
Strength f ck – 3N/mm 2<br />
For M 20 grade or above<br />
Strength f ck – 4N/mm 2<br />
(Where f ck is the characteristic strength of concrete)<br />
7. Common Burnt clay bricks :<br />
7.1. Brick classification : (IS : 1077 & IS : 2180)<br />
Class<br />
CONTRACTOR<br />
Average compressive strength<br />
(M/mm 2 )<br />
22<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
100 100<br />
75 75<br />
35 35<br />
30 30<br />
25 25<br />
20 20<br />
17.5 17.5<br />
15 15<br />
12.5 12.5<br />
10 10<br />
7.5 7.5<br />
5 5<br />
3.5<br />
7.2. Dimension : (IS : 1077)<br />
a. Modular<br />
Length (mm) Width (mm) Height (mm)<br />
190 90 90<br />
190 90 90<br />
b. Non-modular<br />
Length (mm) Width (mm) Height (mm)<br />
230 110 70<br />
230 110 30<br />
N. B. : Tolerance for 20 bricks of modular and non-modular are 80 mm &<br />
40mm for different heights.<br />
7.3. Water absorption : (IS : 3495).<br />
After immersion in cold water for 24 hours<br />
a. Upto class 12.5 : Maximum 20%<br />
b. Higher pressure : Maximum 15%<br />
7.4. Frequency of tests :<br />
20 bricks shall be tested out of 50,000 & 1,00,000 bricks in class 100 & 75.<br />
7.5. Grading of sand for plaster (IS : 1542).<br />
IS sieve designation (mm) Percentage passing by weight<br />
10 100<br />
4.75 95.100<br />
2.236 95-100<br />
1.18 90-100<br />
600 micron 80-100<br />
300 micron 20-65<br />
150 micron 0-50<br />
23<br />
WATER SUPPLY<br />
CONTRACTOR<br />
23<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
24<br />
8. Pipes, pipe fitting valves and specials:<br />
Pipes of different types and classes, pipe fittings, valves and specials used for pipe<br />
laying work should be manufacturer and factory tested hy7drostatically as per the<br />
relevant I.S. specifications as given below. The CI and DI pipes on DGS&D contract are to<br />
be tested by the agency authorized by DGS&D/EPM and PVC pipes and fittings are to be<br />
tested by CIPET (Central Institute of Plastic Engineering and technology).<br />
8.1. Pipe<br />
8.11. Reference to I.S. code :<br />
IS : 1536<br />
Specification for centrifugally cast spun iron pressure pipe for<br />
water, gas & sewege.<br />
IS : 8329<br />
Specification for centrifugally cast (spun) ductile iron pressure pipe<br />
for water, gas & sewege.<br />
IS : 3589<br />
IS : 4985<br />
Specification for electrically welded steel pipe (first revision)<br />
Specification for electrically welded steel pipes (first revision)<br />
IS : 4958<br />
IS : 10221<br />
Un plasticised PVC pipes for potable water supplies.<br />
Code of practice for coating and wrapping under ground steel pipes.<br />
IS : 11906 Recommendation for cement master lining of cast iron milk steel and<br />
ductile Iron pipes and fitting for transport of<br />
water.<br />
8.2. Pipe fittings and jointing materials.<br />
8.2.1. Reference to code :<br />
IS : 1538 Specification for cast iron fitting for pressure pipe (para 1 to 24)<br />
for water, gas & sewge<br />
IS : 10124 Febricated PVC fitting for potable water samples(para 1 to 13)<br />
IS : 782<br />
IS : 5383<br />
Specification for caulking lead<br />
Rubber gaskets for double iron pipes.<br />
8.3. Valves and specials<br />
IS : 780<br />
IS : 2906<br />
IS : 2685<br />
IS : 5312<br />
Specification for sluice valves for water works purpose (50mm to<br />
300mm)<br />
Specification for sluice valves for water works purpose (350mm to<br />
1200mm)<br />
Code of practice for selection installation and<br />
maintenance of sluice values.<br />
Specification for swing check type reflux (Non-return<br />
valves) for water works purpose.<br />
8.3. Inspection of pipes before final acceptance.<br />
24<br />
CONTRACTOR<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
25<br />
Each pipe shall have cast, stamped or indelibly painted the trade mark of<br />
manufacturer, the nominal dia, class weight, batch number, last two digits of the year of<br />
manufacturer and also with ISI certificate mark. The pipes should bear the stamping of<br />
testing agency like DGS & D in case of CI & DI pipes CIPET in case of PVC pipes etc.<br />
8.3.1. Pipe laying<br />
8.3.2. Laying of cast iron pipes :<br />
Inspection of pipes before laying :<br />
Before laying the pipes and fittings shall be inspected for defects and be rung with<br />
a light hammer, preferably while suspended, to detect cracks. Smearing the outside with<br />
chalk dust helps in the location of cracks. If doubt persists further confirmation may be<br />
obtained by pouring a little kerosene on the inside of the pipe at the suspected spot. If<br />
crack is present, the kerosene seeps thorough and shows on the outer surface. Any pipe<br />
found unsuitable after inspection before laying shall be rejected.<br />
Laying should be done as per IS code of practice 3114 (Third Revision).<br />
a) Depth of Trench – The depth of trench should be less than 900mm<br />
measured from the top of pipe to the surface of ground and not less than<br />
750mm else where.<br />
b) Width of Trench : The width of trench should be 200 mm more on either<br />
side of the external dia of pipe (i.e. External dia of pipe + 2 x 200mm).<br />
Additional width shall be provided at position of sockets and flanges for<br />
jointing.<br />
c) Cover over the pipe- Minimum cover of 1M in recommended under road way<br />
and may be modified to meet the local condition.<br />
8.3.3. Laying and jointing of ductile iron pipes :<br />
The pipes should be laid as per the specification laid down in IS : 12288.<br />
a) Width of Trench :- The width of trench at bottom shall provide not less than<br />
200mm clearance on both sides of pipe (i.e. external dia of pipe + 2x 200mm)<br />
b) Cover over the pipe – In agricultural land the depth should be sufficient to<br />
provide cover not less than 900mm and under a roadway the cover should be<br />
minimum 1.0M.<br />
8.3.4. Laying of welded steel pipes :<br />
The laying should be done as per IS – 5822 (First revision).<br />
a) Width of Trench – The width at the bottom below in the faces should not be<br />
less than 200 mm clearance on either side of the pipes.<br />
b) Cover over the pipe – When the pipeline is under a roadway, a minimum cover of<br />
1.0 Meter should be provided and can be modified to suit the local condition by<br />
taking necessary precaution.<br />
c) Pipe welding :- In case of welding the pipe in the trench, additional excavation<br />
of not more than 600 mm in depth 900mm in length should be provided all round<br />
the pipe at the position of the joints for facility of welding.<br />
d) Coating and wrapping of pipes :- Against internal corrosion, steel pipes are given<br />
epoxy lining or hot applied coal tar/asphalt lining or rich cement mortar lining at<br />
works or the field by centrifugal process. The outer coating for under ground<br />
CONTRACTOR<br />
25<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
26<br />
pipeline may be in cement sand gunniting or hot applied coal tar asphalt enamel<br />
reinforced with fiber glass fabric yarn. Coating and wrapping should be done as<br />
per IS 10221.<br />
8.3.5. Laying of PVC pipes :<br />
Laying and joining of PVC pipes should be done as per IS: 7634 (part – III).<br />
a) Width of trench :- The trench should be as narrow as practicable. As a normal<br />
practice this may be kept from 0.30M over the outside dia or pipe (i..e external dia<br />
of pipe + 30 cum.).<br />
b) Depth of Trench – The depth of trench should be 1.00M from the ground level.<br />
c) The trench bottom where it is rocky and un-even a layer of sand or alluvial earth of<br />
100mm depth should be provided under the pipe.<br />
d) Jointing of pipes : Solvent welding technique offers as easy and ample type of joint<br />
in PVC pipe used spigot and socket type joints. The cement solvent to be used for<br />
jointing should be as per the recommendations of the pipe manufacturer.<br />
8.4. Testing of pipe line after laying (field test pressure).<br />
After laying and jointing, the mains shall be slowly and carefully charged with<br />
water, so that all air is expelled from the main by providing a25mm inlet with a stop cock,<br />
allowed to stand full of water for a few days if time permits, and then tested with<br />
pressure.<br />
The field test pressure to be imposed should be not less than the maximum of the<br />
following.<br />
a) 1.5times the maximum sustained operating pressure.<br />
b) 1.5 times the maximum pipeline static pressure.<br />
c) Sum of the maximum sustained operating pressure and the maximum surge<br />
pressure.<br />
d) Sum of the maximum pipe line static pressure and the maximum equal to the work<br />
test pressure for any pipe fitting in corporate.<br />
9.0. Production wells (large dia tube wells):<br />
9.1. Materials for constructions :<br />
1. Casting pipes should be mild steel or UPVC pipes. Mild steel pipes should<br />
conform to IS :4270 and ASTM-DN-1785. The UPVC pipes should be of<br />
ASTM quality (Sch-40, Sch-80 or Sch-120 depending on site condition) and<br />
should also confirm to IS:2818.<br />
2. Well screens and slotted pipes should conform to IS : 8110. The well<br />
screens may be monometal, bimetal, stainless steel or PVC.<br />
Sufficient opening should be provided for screens and slotted pipes so that 70% or<br />
more of sand grains in the natural aquifer where uniformity co-efficient should range<br />
between 2.0 to 2.50. For soils with uniformly coefficient less than 1.5, pea gravel pack<br />
should be used.<br />
The total area of opening should be such s to maintain on entrance velocity less<br />
than necessary to carry the finest particle of sand that is to be excluded by the screen.<br />
In general, it should be 4 to 6 cm/sec. With the gravel shrouding.<br />
The opening should preferably be ‘V’ shaped.<br />
CONTRACTOR<br />
26<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
27<br />
3. Gravel to be used for shrouding (packing around the casing pipe) should confirm to<br />
IS : 4099. The gravel wall provided may vary in thickness to suit the size and depth<br />
of boring and may vary from 10cm to 25cm but usually 10cm.<br />
9.2. Construction of tube well :<br />
The drilling operation should be taken up with rotary drilling rig. Down the whole<br />
Hammer Rig or Combination Rig depending on type of strata and conforming to IS :2800<br />
(Part-I).<br />
For drilling with rotary drilling rig in soft formations, bentonite powder should be<br />
used in place of local mud as sealing compound to facilitate drilling operation. The casing<br />
pipe and well strainer should be lowered perfectly vertically and well screen should be<br />
properly placed against the aquifers. The casing pipe should be extended to at least 60 cm<br />
above the ground level.<br />
The annular space between the bore and the housing pipe (casing pipe) should be<br />
cement grouted upto at least 5m below ground level to provide a sanitary sealing.<br />
9.3. Testing and development of tube well :<br />
9.3.1. The testing of tube well should be conducted as per IS : 2800 (part-II).<br />
Tube wells are to be tested for plumbness and alignment normally after completion<br />
of drilling but immediately after the housing pipes are installed and prior to<br />
commencement of gravel fitting in the case of gravel shrouded tube well. For wells<br />
encased with pipes less than 350mm dia meter, the verticality of tube well shall have a<br />
deviation not exceeding 10cm per 30 m depth of the tube well and the deviation shall be in<br />
one direction and in one place only.<br />
In the case gravel shrouded tube well, if the pipe assembly is found included in a<br />
start position. It should be pulled in a desired directions to rectify the stantness and<br />
bringing the pipe assembly into permissible limit of verticality.<br />
9.3.2. Development of tubewell :<br />
The object of well development is the removal of silt, fine sand and other such<br />
materials form a zone immediately around the well, screen, there by creating larger<br />
passage in the formation through which water can flow more freely towards the<br />
wells.<br />
Well development includes the operation of flushing, testing and equipping the wells<br />
before they are put into service.<br />
The development should be carried on with an air compressor of suitable capacity<br />
(to develop 7kg to 10kg/Cm 2 and airflow of 2m 3 /min) In accordance with IS : 11189,<br />
and the process should be continued until the stabilization of sand gravel pack and<br />
discharge of clear water is fully assured.<br />
10. Pumping sets :<br />
10.1. Reference & code<br />
The pumping sets and accessories should conform to following IS specification:<br />
IS 1520<br />
Horizontal centrifugal pumps for clear cold fresh water (2 nd revision)<br />
CONTRACTOR<br />
27<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
28<br />
IS 6595<br />
IS 9684<br />
IS 1710<br />
IS 8034<br />
IS 10825<br />
Horizontal centrifugal pumps for clear cold fresh water for Agricultural<br />
purpose (first revision).<br />
Selection, installation, operation and maintenance of Horizontal centrifugal<br />
pumps for agricultural purpose.<br />
Vertical turbine pumps for clear. Cold fresh water (1 st revision).<br />
Submersible pump sets for clear, cold, fresh water.<br />
Foot valve, Reflex value or non return valve and bore valves to be used in<br />
suction line of agriculture pumping sets. (first revision).<br />
IS 325/19758<br />
Three phase induction motors.<br />
IS 7538<br />
Motors for submersible pumps<br />
10.2. Inspection of pumps before final acceptance.<br />
1. The name plates of the pump and motor with details like Sl. No.- Head,<br />
Discharge, rpm, HP/KW of motor etc engraved on the name plate should be<br />
clearly verified to confirm within the pumping set is as per the supply<br />
order.<br />
2. Manufacturer’s test report along with laboratory hydrostatic test reports<br />
of the pumps should be verified to know the duty of pump.<br />
3. The supplier should give at lest one copy of specific installation and<br />
operation manual of the pumping sets supplied by them.<br />
4. The field test for pumps should be conducted to confirm the duty of pumps<br />
after ins installation.<br />
10.3. Pump installation<br />
The installation of centrifugal pumps should proceed through five stages in the<br />
following order.<br />
1. Preparing the foundation and locate the foundation bolts.<br />
2. Locating the pump on the foundation bolts, however resting on leveling wedges,<br />
which permit not only easy leveling but also space for fitting the grunt later on.<br />
3. Levelling<br />
4. Grouting<br />
5. Alignment<br />
The foundation should be sufficiently substantial to absorb vibrating and to form a<br />
permanent, rigid support for the base plate.<br />
Alignment of the pump sets should be checked even if they are received aligned by<br />
the manufacturer. The alignment should be proper both for parallelism (by filler gauge)<br />
and for coasiablity (by straight edge or by dial gauge).<br />
During all alignment- checks both the shafts should be pressed hard, over to one<br />
side while talking the readings alignment should also be checked after fastening the piping<br />
and there after periodically during operation.<br />
Submersible pumps with wet type motors should be fitted with water and the<br />
opening should be properly plugged after filling water.<br />
Pumps kept in storage for a long time should be thoroughly cleaned before<br />
installation.<br />
CONTRACTOR<br />
28<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
29<br />
10.4. Testing of pumps :<br />
There are two types of pumps testing.<br />
1. Testing in the shop or laboratory at the manufacturer works.<br />
2. Testing in the field after installation<br />
Every pump must be tested before it is finally accepted. It is necessary for<br />
comparision of specified, predicated and actual performance after installation, relating<br />
to head, discharge power, efficiency and suction requirements centrifugal pumps should<br />
be listed as per IS-9137 (Class ‘C’ code of testing) and IS-11346.<br />
The scheme of testing includes taking readings, doing calculation and plotting of<br />
(i) The H-Q characteristics<br />
(ii) The P-Q characteristics.<br />
(iii) The efficiency versus Q characteristics<br />
11. Water Quality<br />
11.1. Recommended guidelines for physical and chemical parameter:<br />
Sl.<br />
No.<br />
Characteristics *Acceptable **Cause for<br />
1. Turbidity (NTU) 1 10<br />
2. Colour (Units on Platinum Cobalt<br />
scale)<br />
5 25<br />
3. Teste and Odour Unobjectionable Objectionable<br />
4. PH 7.0 to 8.5 9.0<br />
5. Total dissolved solids (mg/I) 500 2000<br />
6. Chlorides (as CI) (mg/I) 20 600<br />
7. Chlorides (as CI) (mg/I) 200 1000<br />
8. Sulphates (as SO 4 (mg/I) 200 400<br />
9. Fluorides (as F) (mg/I) 1.0 1.5<br />
10. Nitrates (as NO 3 (mg/I) 45 45<br />
11. Calcium (as Ca) (mg/I) 75 200<br />
12. Magnesium (as Mg) (mg/I) 30 150<br />
If there are 250 mg/I of sulphates, Mg content can be increased to maximum<br />
of 125mg/I with the reduction of sulphates at the rate of I unit per every 2.5 units<br />
of sulphates.<br />
Sl.<br />
No.<br />
Characteristics *Acceptable **Cause for<br />
13. Iron (as Fe) mg/I 0.1 1.0<br />
14. Manganese (as Mn) mg/I 0.05 0.5<br />
CONTRACTOR<br />
29<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
15. Copper (as Cu) (mg/I) 0.05 1.5<br />
16. Aluminium (as AI) (mg/I) 0.03 0.2<br />
17. Residual Chloride (mg/I) 0.2 >1.0<br />
18. Zinc (as Zn) (mg/I) 5.0 15.0<br />
19. Phenolic compounds (as Phenol)<br />
(mg/I)<br />
20. Anionic detergents (mg/I) (as<br />
MBAS)<br />
30<br />
0.001 0.002<br />
0.2 1.0<br />
21. Mineral Oil (mg/I) 0.01 0.03<br />
TOXIC MATERIALS<br />
22. Arsenic (as As) (mg/I) 0.01 0.05<br />
23. Cadmium (as CD) (mg/I) 0.01 0.01<br />
24. Chromium<br />
(as hexavalent Cr) (mg/I) 0.05 0.05<br />
25. Cyanides (as CN) (mg/I) 0.05 0.05<br />
26. Lead (as Pb) (mg/I) 0.05 0.05<br />
27. Selenium (as SC) (mg/I) 0.01 0.01<br />
28. Mercury (total as Hg)<br />
(mg/I) 0.001 0.001<br />
29. Polynuclear aromatic 0.2 0.2<br />
Hydrocarbons (PAH) (ug/I)<br />
Pesticides (total, mg/I) Absent Refer to WHO<br />
guidelines for<br />
drinking water<br />
quality Vol.-I-1993<br />
RADIO ACTIVITY<br />
30. Gross Alpha activity (Bq/I) 0.1 0.1<br />
31. Gross Beta activity (Bq/I) 0.1 1.0<br />
The figures indicated under the column ‘Acceptable’ are the limits upto which<br />
water is generally acceptable to the consumers.<br />
Figures in excess of those mentioned under ‘Acceptable’ render the water not<br />
acceptable, but still may be tolerated in the absence of an alternative and better source<br />
but upto the limits indicated under column “Cause for Rejection” above which the sources<br />
will have to be rejected.<br />
CONTRACTOR<br />
30<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
31<br />
It is possible that some mine and spring waters may exceed these radio activity<br />
limits and in such cases it is necessary to analyses the individual radio-nuclide order to<br />
assess the acceptability or otherwise for public consumption.<br />
<br />
Sr. Divisional Manager<br />
(Building Project-I)<br />
Sl.<br />
No<br />
PROFORMA-'A'<br />
CERTIFICATE OF LIST OF WORKS IN HAND<br />
I/We do hereby certify that the following works have been executed by<br />
me/us in the past.<br />
Particulars<br />
of works<br />
now in<br />
hand<br />
Amount of<br />
each work<br />
Period which<br />
the work is<br />
stipulated to<br />
be<br />
completed<br />
(in month)<br />
Approximate value<br />
of work done<br />
against each work<br />
on the date of<br />
submission of<br />
Tender<br />
Deptt.<br />
Under which<br />
the work is<br />
being taken<br />
up.<br />
Remark<br />
s<br />
1 2 3 4 5 6 7<br />
CONTRACTOR<br />
31<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
32<br />
I/We also note that, non-submission of this certificate may render my/our tender<br />
liable for rejection.<br />
Signature of the tenderer<br />
Date________________<br />
CERTIFICATE OF EMPLOYMENT OF UN-EMPLOYED GRADUATE<br />
ENGINEERS/DIPLOMA HOLDERS<br />
(For Special Class and 'A' Class Contractors only)<br />
I/We do hereby certify that at present the following Engineering personnel are<br />
working with me/in our firm/company and their bio-data are furnished below:<br />
Sl.<br />
No<br />
.<br />
Name of<br />
Engineering<br />
personnel<br />
appointed for<br />
supervising<br />
contractor's<br />
works with<br />
address<br />
Qualificat<br />
ion<br />
Date of<br />
appointme<br />
nt<br />
Monthly<br />
emolume<br />
nt<br />
Whether full<br />
time<br />
engagement<br />
and<br />
continuous<br />
If they are<br />
Superannuated/<br />
Retired/ dismissed<br />
or removed<br />
personnel from<br />
State Govt./<br />
Central Govt./<br />
Public sector<br />
undertakings/<br />
Private companies<br />
and firms or any<br />
one ineligible for<br />
Govt. service.<br />
1 2 3 4 5 6 7<br />
I/We also note that non-submission of this certificate may render my/our tenders<br />
liable for rejection.<br />
Signature of the tenderer<br />
Date________________<br />
CONTRACTOR<br />
32<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
33<br />
PROFORMA-'B'<br />
CERTIFICATE OF LIST OF WORKS EXECUTED<br />
I/We do hereby certify that the following works have been executed by<br />
me/us in the past.<br />
Sl.No.<br />
Particulars of<br />
works already<br />
executed<br />
Approximate<br />
amount of<br />
each work<br />
Name of<br />
Deptt.<br />
under<br />
which the<br />
works were<br />
executed<br />
Period of<br />
commencemen<br />
t and period<br />
of completion<br />
Whether the<br />
works were<br />
completed in<br />
stipulated<br />
period<br />
1 2 3 4 5 6 7<br />
Remark<br />
s<br />
I/We also note that, non-submission of this certificate may render my/our tender<br />
liable for rejection.<br />
Signature of the tenderer<br />
Date________________<br />
CONTRACTOR<br />
33<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
34<br />
WORK PROGRAMME<br />
Name of the Work: Construction of Tourist Reception Centre at Saunleipitha in Ganjam<br />
District. under Destination Development Scheme<br />
Time<br />
Description of work<br />
1 st Month<br />
2 nd Month<br />
3 rd Month<br />
4 th Month<br />
5 th Month<br />
6 th Month<br />
CONTRACTOR<br />
34<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
35<br />
TENDER SCHEDULE FOR THE WORK:- Construction of Tourist Reception Centre at<br />
Saunleipitha in Ganjam District. under<br />
Destination Development Scheme<br />
Sl.<br />
No<br />
Description of Items Qnty. Unit Rate Amount<br />
1 2 3 4 5 6<br />
PUBLIC CONVENIENCE<br />
1 Earthwork in excavation of foundation<br />
trenches in ordinary soil including moorum<br />
stoney earth and earth mixed with<br />
boulders except sheet rock and boulders<br />
requiring blasting including dressing of<br />
sides and leveling the bed up to the<br />
required depth and depositing the<br />
excavated materials away from the work<br />
site with all leads and lifts, including<br />
shoring, shuttering and dewatering (if<br />
required) with cost of labour, hire &<br />
running charges of water pumps sundries &<br />
T&P required for the work complete as<br />
directed by the Engineer-in-charge. 345.09 Each Cum 39.09 13489.57<br />
2 Supplying and filling in foundation trenches<br />
and plinth, ditches with sand well watered<br />
and rammed in layers not exceeding 23 cm.<br />
In depth with all lead and lift including<br />
cost, conveyance, loading, unloading,<br />
royalties and taxes of all materials, cost of<br />
all labour, sundries, T&P required for the<br />
work etc. complete in all respect as per<br />
specification and direction of Engineer-incharge.<br />
(Measurement will be taken on<br />
finished compacted section only). 1096.89 Each Cum 180.80 198317.71<br />
3 Providing and lying plain cement concrete<br />
of proportion (1:4:8) in foundation and<br />
floors using Portland Slag Cement(PSC)<br />
with 4 cm. Size black hard crusher broken<br />
granite stone metal and screened and<br />
washed sharp sand for mortar of approved<br />
quality from approved quarry, washed and<br />
cleaned including hoisting, lowering, laying<br />
concrete, ramming, watering and curing<br />
etc. complete to required levels laid in<br />
layers not exceeding 15 cm thick in each<br />
layer including cost, conveyance, loading, 87.28 Each Cum 2825.80 246635.82<br />
CONTRACTOR<br />
35<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
36<br />
unloading, royalties and taxes all materials<br />
and cost all labours, sundries, T & P<br />
required for the work including shoring,<br />
shuttering and dewatering if required<br />
including hire & running charges of water<br />
pump complete as per specification and<br />
direction of Engineer-in-charge.<br />
4 Providing Random Rubble stone masonry in<br />
cement mortar of mix (1:6) with Portland<br />
slag cement (PSC) in foundation & plinth<br />
with screened and washed sharp sand for<br />
mortar of approved quality from approved<br />
quarry and using black hard hand broken<br />
granite stone free from weathered skins<br />
of approved size, weight and quality from<br />
approved quarry including providing key<br />
stones in regular intervals for each layer<br />
including splays cutting, circular moulding<br />
and similar such type of works with all<br />
necessary projections, champering and<br />
corbelling, watering and curing etc. with all<br />
cost, conveyance, royalties, loading &<br />
unloading & tax of all materials and cost of<br />
all labour, sundries, T & P required for the<br />
work including hoisting, lowering,<br />
dewatering if required etc. complete in all<br />
respect as directed by Engineer-in-Charge 172.64 Each Cum 1802.80 311235.39<br />
5 Providing, lifting, hoisting and laying<br />
Reinforced cement concrete of M-200<br />
grade as per approved designs and<br />
drawings having a minimum compressive<br />
strength (in work test) 200 Kg. / Square<br />
cm. in 15 cm. cubes at 28 days after mixing<br />
and test conducted in accordance with I.S.<br />
516 using 12 mm. to 20 mm. size black hard<br />
crushed broken granite stone chips and<br />
screened and washed sharp sand for<br />
mortar of approved quality from approved<br />
quarry, washed and cleaned ( 20mm. size<br />
chips not to exceeds 25 % ) to be mixed in<br />
concrete mixture with Portland slag<br />
cement (PSC) including hoisting, lowering,<br />
laying and compaction concrete by using<br />
vibrators, watering and curing for 28 days,<br />
centering and shuttering then after<br />
CONTRACTOR<br />
36<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
dismantling and removing debris from the<br />
work site and finishing the exposed<br />
surface smooth providing grooves or beads<br />
wherever necessary including cost,<br />
conveyance, loading, unloading, royalties<br />
and taxes of all materials and cost of all<br />
labours, sundries, T & P required of the<br />
work etc. complete in all respect as<br />
directed by the Engineer-in-Charge. But<br />
excluding cost and conveyance of M.S. rods<br />
or Tor steel and binding wires and labour<br />
charges for straightening, cutting, bending<br />
etc. of M.S. rods or tor steel tying the<br />
grills and placing in proper position.<br />
a) Column base<br />
37<br />
i)Ground floor<br />
b) Column<br />
i)Ground floor<br />
ii)First floor<br />
c) Plinth band/ Grade beam<br />
i)Ground floor<br />
d) Lintel<br />
i)Ground floor<br />
ii)First floor<br />
e) Beam<br />
i)Ground floor<br />
ii)First floor<br />
f) Roof slab<br />
i)Ground floor<br />
ii)First floor<br />
g) Staircase<br />
i)Ground floor<br />
h) Chajja<br />
CONTRACTOR<br />
37<br />
27.59 Each Cum 4465.10 123192.11<br />
7.52 Each Cum 6834.50 51395.44<br />
1.60 Each Cum 7351.50 11762.40<br />
21.38 Each Cum 4701.70 100522.35<br />
3.95 Each Cum 6560.70 25914.77<br />
0.63 Each Cum 7023.00 4424.49<br />
14.53 Each Cum 6834.50 99305.29<br />
1.96 Each Cum 7351.50 14408.94<br />
28.9 Each Cum 6639.90 191893.11<br />
3.38 Each Cum 7118.10 24059.18<br />
1.08 Each Cum 6544.90 7068.49<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
38<br />
i)Ground floor<br />
ii)First floor<br />
i)shelf<br />
15.24 Each Sqm 534.00 8138.16<br />
0.74 Each Sqm 585.60 433.34<br />
Ground floor<br />
4.49 Each Sqm 414.00 1858.86<br />
6 Providing, fixing and placing of MS bars/<br />
Tor steel (HYSD) for RCC work in all<br />
floors of required diameter of approved<br />
quality with straightening, Cutting,<br />
bending, binding welding or jointing if<br />
necessary, bending, binding, tying the grills<br />
as required for R.C.C. works, providing fan<br />
hooks where necessary and hoisting,<br />
lowering and placing in proper position<br />
according to approved designs and<br />
drawings including cost, conveyance,<br />
loading, unloading, taxes of M.S. rods or<br />
Tor steel and binding wires of 18 to 20<br />
gauge required for the work and cost of all<br />
labour, sundries, T & P and scaffolding<br />
complete in all respect as directed by the<br />
Engineer-in-Charge ( payment will be made<br />
according to the actual weight of M.S rod<br />
/Tor steel consumed in the work and no<br />
separate payment will be made towards<br />
weight of binding wires which is to be<br />
borne by the contractor at his own cost<br />
i)Ground floor<br />
111.56 Each Qntl 6270.40 699525.82<br />
ii)First floor<br />
10.06 Each Qntl 6276.80 63144.61<br />
7 First class well burnt brick masonry using<br />
K.B. bricks of size 23 cm. x 11 cm. x 8 cm.<br />
Having crushing strength not less than 75<br />
kg. Per Sqr. Cm. In cement mortar of mix<br />
(1:6) with screened and washed sharp sand<br />
for mortar after immersing the bricks for<br />
6 (six) hours in water before use in<br />
foundation and plinth for masonry work,<br />
ornamental flower beds, plinth moulding<br />
and similar such type of works with all<br />
necessary projections, splays cutting,<br />
circular moulding, corbelling, chamfering<br />
watering and curing etc. including cost, 56.10 Each Cum 2530.60 141966.66<br />
CONTRACTOR<br />
38<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
39<br />
conveyance, loading, unloading, royalties<br />
and taxes of all materials and cost of all<br />
labour, sundries, T&P required for the<br />
works etc. complete in all respect as per<br />
specification and direction of Engineer-incharge.<br />
8 First class well burnt brick masonry using<br />
K.B. bricks of size 23 cm. x 11 cm. x 8 cm.<br />
Having crushing strength not less than 75<br />
kg. Per Sqr. Cm. In cement mortar of mix<br />
(1:6) with screened and washed sharp sand<br />
for mortar after immersing the bricks for<br />
6 (six) hours in water before use in<br />
superstructure for masonry work,<br />
ornamental flower beds, plinth moulding<br />
and similar such type of works with all<br />
necessary projections, splays cutting,<br />
circular moulding, corbelling, chamfering<br />
watering and curing etc. including cost,<br />
conveyance, loading, unloading, royalties<br />
and taxes of all materials and cost of all<br />
labour, sundries, T&P required for the<br />
works etc. complete in all respect as per<br />
specification and direction of Engineer-incharge.<br />
i)Ground floor<br />
ii)First floor<br />
9 Providing 16mm thick cement plaster in all<br />
floors at all height with cement mortar of<br />
mix (1:6) with Portland slag cement (PSC)<br />
and with screened and washed sharp sand<br />
for mortar and finished smooth to the<br />
rough surface of brick masonry walls after<br />
racking out joints including watering and<br />
curing rounding of corners etc. complete<br />
with cost, conveyance, loading, unloading,<br />
royalties and taxes of all materials, cost of<br />
all labour, T&P, sundries and scaffolding<br />
required for the work etc. with providing<br />
grooves as directed by the Engineer-in-<br />
Charge<br />
i)Ground floor<br />
ii)First floor<br />
CONTRACTOR<br />
39<br />
57.07 Each Cum 2564.00 146327.48<br />
21.87 Each Cum 2636.20 57653.69<br />
470.59 Each Sqm 81.70 38447.20<br />
116.28 Each Sqm 83.00 9651.24<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
40<br />
10 Providing 12mm. thick cement plaster with<br />
cement mortar of mix (1:6) in all floors<br />
with Portland slag cement (PSC) with neat<br />
cement punning and two coats of bitumen<br />
painting over top of the walls complete<br />
including watering and curing along with<br />
the cost, conveyance, loading and unloading,<br />
royalties and taxes of all materials and<br />
cost of all labours, sundries, T&P and<br />
scaffolding required for the work etc.<br />
complete in all respect as directed by the<br />
Engineer–in-Charge.<br />
i)Ground floor 220.78 Each Sqm 60.90 13445.50<br />
ii)First floor 100.21 Each Sqm 62.40 6253.10<br />
11 Providing 6 mm. thick cement plaster with<br />
cement mortar of mix (1:4) in all floors at<br />
all height with screened and washed sharp<br />
sand for mortar to ceiling plaster of roof<br />
slab, staircase, landings, chajja and shelves<br />
etc. including roughening, scraping,<br />
chiseling, cleaning closed deep chipping<br />
with slurry treatment and finished smooth<br />
to all R.C.C surface including cost,<br />
conveyance, loading, unloading, royalties<br />
and taxes of all materials, cost of all<br />
labour, sundries, T&P , scaffolding,<br />
watering and curing etc. complete in all<br />
respect as per specification and direction<br />
of Engineer-in-charge.<br />
i)Ground floor 283.60 Each Sqm 65.70 18632.52<br />
ii)First floor 22.14 Each Sqm 66.70 1476.74<br />
12 20mm. thick cement plaster in cement<br />
mortar (1:6) finished smooth to stone<br />
masonry after racking out joints including<br />
watering & curing with cost, conveyance,<br />
royalties, loading, unloading and taxes of all<br />
materials and cost of all labour, T&P,<br />
sundries, scaffolding etc. required for the<br />
work as directed by the Engineer-in-<br />
Charge. 138.79 Each Sqm 93.30 12949.11<br />
13 Providing 20mm thick granite tile flooring<br />
(using granite tile above 0.4 sqm ) of<br />
approved quality, colour and size in floors,<br />
treads on steps and landings in all floors at<br />
all height on 25mm thick bed of cement<br />
CONTRACTOR<br />
40<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
41<br />
mortar of mix (1:1) laid in proper slope and<br />
gradient with screened and washed sharp<br />
sand for mortar and grouted with neat<br />
white cement slurry joining the tile with<br />
neat white cement slurry mixed with<br />
required quantities of pigments of<br />
approved marks to match the shades of<br />
the granite tile if required watering and<br />
curing for 21 days, including cost,<br />
conveyance, loading, unloading, royalties<br />
and taxes of all materials, cost of all<br />
labour, sundries, T&P required for the<br />
work including rubbing mechanically and<br />
wax polishing etc. complete in all respect<br />
as per specification and direction of<br />
Engineer-in-charge.<br />
i)Ground floor 166.90 Each Sqm 2025.00 337972.50<br />
ii)First floor 5.19 Each Sqm 2027.70 10523.76<br />
14 Providing 10mm thick granite tile(using<br />
granite tile above 0.1 Sqm. Up to 0.4 sqm )<br />
of approved quality, colour and size in<br />
Dadoes over 12mm thick cement plaster<br />
1:3 (1 Cement: 3 Coarse sand) finished with<br />
modular pointing in white cement & pigment<br />
to match the shade of the tiles including<br />
cost, conveyance, loading, unloading,<br />
royalties and taxes of all materials, cost of<br />
all labour curing sundries and T & P etc.<br />
required for the work etc. complete as per<br />
specification and direction of Engineer-incharge.<br />
21.48 Each Sqm 1308.20 28100.14<br />
15 Providing 30cmx30cm/40cmx40cm special<br />
plain/printed series ceramic floor tiles of<br />
premium grade having thickness 7mm to<br />
8mm conforming IS13755 for ceramic tile<br />
flooring of approved quality, colour and<br />
size in floors, treads on steps and landings<br />
in all floors at all height on 10mm thick bed<br />
of cement mortar of mix (1:1) laid in proper<br />
slope and gradiant with screened and<br />
washed sharp sand for mortar and with<br />
ordinary Portland slag cement (PSC)<br />
grouted with neat white cement slurry<br />
joining the tile with neat white cement<br />
slurry mixed with required quantities of 45.23 Each Sqm 636.30 28779.85<br />
CONTRACTOR<br />
41<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
42<br />
pigments of approved marks to match the<br />
shades of the ceramic tile if required ,<br />
watering and curing for 21 days, including<br />
cost, conveyance, loading, unloading,<br />
royalties and taxes of all materials, cost of<br />
all labour, sundries, T&P required for the<br />
work including rubbing mechanically and<br />
wax polishing etc. complete in all respect<br />
as directed by the Engineer-in-charge.<br />
16 Providing 20cmx30cm/20cmx20cm special<br />
plain/printed series ceramic glazed wall<br />
tiles of premium grade having thickness<br />
6.5mm to6.7mm conforming IS 13753 of<br />
approved make & shade in Dadoos over<br />
12mm thick cement plaster 1:3 (1 Cement:<br />
3 Coarse sand) finished with modular<br />
pointing in white cement & pigment to<br />
match the shade of the tiles including cost,<br />
conveyance, loading, unloading, royalties<br />
and taxes of all materials, cost of all<br />
labour curing sundries and T & P etc.<br />
required for the work etc. complete as per<br />
specification and direction of Engineer-incharge.<br />
119.88 Each Sqm 520.40 62385.55<br />
17 Supplying, fitting and fixing well dressed<br />
and well seasoned sal wood choukaths of<br />
different length and 6.35cm. x 12.70cm.<br />
sizes in all floors in proper position<br />
including two coats coats of coaltaring to<br />
wall and lintel side faces of choukaths<br />
including cost of coaltar and labour for<br />
coaltaring and fixing required nos. of W.I.<br />
clamps to the choukaths with approved<br />
qualities of screws including cost,<br />
conveyance, loading, sundries, T&P required<br />
for the work etc. complete in all respect as<br />
directed by the Engineer-in-charge but<br />
excluding the cost of W.I. clamps. 0.26 Each Cum 37316.90 9702.39<br />
18 Supplying, fitting & fixing of Flush door<br />
using 32mm thick BWR Block Board(I.S.I)<br />
with 4mm thick teak wood veneer both side<br />
including melamine polish etc complete with<br />
Floor spring (make- Godrej),Door<br />
stopper(DS1),Handel(Godrej make 10Ck<br />
Universal Brass Handel Set) including 13.66 Each Sqm 5925.90 80947.79<br />
CONTRACTOR<br />
42<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
43<br />
necessary Hardware and other required<br />
fittings complete in all respect with cost<br />
of all materials and labour all taxes<br />
,transportation and as per the drawings<br />
given by Architect and the direction of the<br />
Engineer -in- charge.<br />
19 Providing and fixing factory made UPVC<br />
frame with shutter for windows made of<br />
UPVC extruded section having an overall<br />
dimension, as below (tolerance ± 1mm) with<br />
all thickness 2mm ± 0.2mm .Corners of the<br />
door frame to be jointed with galvanized<br />
brackets and stainless steel screws,<br />
jointed and mired and plastic welded. The<br />
hinge side vertical of the frame<br />
reinforced by galvanized M.S tube of size<br />
19mmx19mm and 1mm ± 0.1mm wall<br />
thickness and 3 no stainless steel hinges<br />
fixed to the frame complete as per<br />
manufacture specification and direction of<br />
Engineer in charge.(Extruded section<br />
profile size 42x50mm) :(MAKE :LG or<br />
equivalent ) complete in all respect as<br />
directed by the Engineer-in-charge. 18.68 Each Sqm 5489.80 102549.46<br />
20 Providing fitting and fixing of 30mm thick<br />
factory made of solid panel PVC door<br />
shutter ( conforming to criteria of testing<br />
as per IS:4020 with upto date<br />
amendments) of approved quality<br />
consisting of frame made out of M.S. tubes<br />
of 19 gauge thickness and size of 19mm x<br />
19mm for stiles, and 15mm x 15mm for top<br />
and bottom rails. M.S. frame shall have a<br />
coat of steel primers of approved make<br />
and manufacture. M.S. frame shall be<br />
covered with 5mm thick heat moulded “<br />
Rajshri” PVC ‘C’ channel of size 30 x 50mm<br />
forming stiles, and 5mm thick, 75mm wide<br />
PVC sheets for top rail, lock rail and<br />
bottom rail on either side, and 10mm (5mm<br />
x 2) thick, 20mm wide cross PVC sheet as<br />
gap insert for top rail and bottom rail.<br />
Paneling of 5mm thick PVC sheet to be<br />
fitted in the M.S. frame welded/sealed to<br />
the stiles and rails with 30mm wide x 5mm 14.63 Each Sqm 2506.00 36662.78<br />
CONTRACTOR<br />
43<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
thick PVC sheet beading on either side, and<br />
joined together with solvent cement<br />
adhesive etc. an additional 5mm thick PVC<br />
strip of 20mm width is to be stuck on the<br />
interior side of the ‘C’ channel using PVC<br />
solvent adhesive including PVC door frame<br />
(Choukhat) of PVC Hollow Door Frame of<br />
size 50mmx47mm with a wall thickness of<br />
5mm,made out of extruded 5mm rigid PVC<br />
foam sheet, miter cut at two corners and<br />
joined with 2nos. of 150mm long brackets<br />
of 15x15mm M.S. square tube. The two<br />
vertical door profiles are to be reinforced<br />
with 19x19mm M.S. Square tube of 19<br />
gauge, EPDM rubber gasket Weather seal<br />
to be provided through out the frame. The<br />
door frame shall be fixed to the wall using<br />
65/100mm long M.S. Screws through the<br />
frame by using PVC fasteners. A minimum<br />
of 4nos. of screws to be provided for each<br />
vertical member & minimum 2nos. for<br />
horizontal member of approved quality<br />
including drilling holes in masonry wall<br />
with cost of all materials, rawlplug , screws<br />
and other required fittings with cost of all<br />
materials, all taxes, labour T & P etc<br />
complete as per specification and direction<br />
of Engineer –in-charge.<br />
44<br />
21 Supplying, fitting and fixing of Stainless<br />
steel of 304 grade in hand railing using<br />
50mm dia of 2mm thick circular pipe with<br />
balustrade of size 32mm x 32mm x 2mm @<br />
0.90mtr. C/C and stainless square pipe<br />
bracing of size 32mm x 32mm x 2mm in 3<br />
rows in stair case as per approved design<br />
and specification, buffing, polishing etc.<br />
with cost, conveyance, taxes of all<br />
materials, T & P etc. required for the<br />
complete in all respect as directed by the<br />
Engineer-in-charge. 16.64 Each Rmt 3169.00 52732.16<br />
22 French polishing two coats to Doors &<br />
Windows with any approved polish or with<br />
prepared polishing materials like sprit, lac<br />
be required to give the best polished 8.10 Each Sqm 44.20 358.02<br />
CONTRACTOR<br />
44<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
45<br />
surface to wood work after cleaning the<br />
surface smooth including the cost,<br />
conveyance, loading, unloading and taxes of<br />
all materials and cost of all labour, T & P,<br />
sundries required for the work complete in<br />
all respect as directed by the Engineer-incharge.<br />
23 Providing and painting two coats with<br />
plastic emulsion paint of approved quality<br />
and approved shade manufactured by<br />
reputed manufacture like NEROLAC<br />
/ASIAN /BERGER /DULOX or equivalent<br />
to make in all floors at all height by making<br />
the surface to the interior plastered<br />
surface of wall smooth with a coat of<br />
Acrylic Putty and primer of approved<br />
quality including cost, conveyance, loading<br />
and unloading and taxes of all materials,<br />
cost of all labour, sundries, T & P,<br />
scaffolding etc. required for the work and<br />
complete in all respect as per specification<br />
and direction of Engineer-in-charge.<br />
i)Ground floor 665.17 Each Sqm 118.50 78822.65<br />
ii)First floor 60.71 Each Sqm 119.30 7242.70<br />
24 Wall painting two coats with 100% Acrylic<br />
emulsion paint (1 st quality) exterior grade<br />
(weather coat) of approved make & shade<br />
manufactured by reputed manufacture like<br />
NEROLAC /ASIAN /BERGER /DULOX or<br />
equivalent to make an even finished<br />
surface over a coat of primer with water<br />
bond cement primer in all heights with all<br />
scaffolding and staging charges including<br />
cost, conveyance, taxes of all materials,<br />
cost of all labour, etc. complete as per<br />
specification and direction of Engineer-in-<br />
Charge. 0.00<br />
i)Ground floor 448.59 Each Sqm 56.50 25345.34<br />
ii)First floor 170.65 Each Sqm 57.30 9778.25<br />
PH<br />
25 Supplying all material and labour tools and<br />
plants & fitting, including testing & jointing<br />
of the following Astral CPVC pipes and<br />
fittings in SDR 11 and SDR 13.5 fittings<br />
having ISI mark with points including<br />
CONTRACTOR<br />
45<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
46<br />
supply of pipe and pipes to lengths<br />
including wastage providing necessary<br />
offsets and long screw with extra socket<br />
and jam nut including earthwork in<br />
excavation of pipe line trenches in 0.3048<br />
mtr. layers with fully watering and ramming<br />
, providing pegs , threads, lights , barriers<br />
etc., or fixing to walls & floors with supply<br />
of holder-bat-clamps fixing wooden plugs<br />
in walls complete as per I.S specification<br />
including cost , conveyance and taxes of all<br />
materials etc., complete and as per the<br />
direction of Engineer-in-charge<br />
(Make- Oriplast/ Supreme)<br />
a) 20mm dia CPVC pipe 65.00 Each Rmt 94.60 6149.00<br />
b) 40mm dia CPVC pipe 35.00 Each Rmt 219.00 7665.00<br />
c) 50mm dia CPVC pipe 40.00 Each Rmt 356.40 14256.00<br />
26 Providing fitting & fixing of the following<br />
SWR U-PVC pipes as per IS-13592<br />
(Oriplast/Supreme) and fittings as per IS-<br />
14735 on the wall surface below the floor<br />
and ground level for use as soil waste and<br />
anti-syphonic pipes fixing the pipes and<br />
fitting on the wall<br />
a)75mm dia UPVC pipe 16.20 Each Rmt 123.80 2005.56<br />
b)110mm dia UPVC pipe 70.00 Each Rmt 220.10 15407.00<br />
27 Providing and fixing porcelain EWC with “P”<br />
of “S” trap with vent horn ISI marked and<br />
approved make (Hind ware- Cat. No-<br />
92058)(S-22) coupled with 10 litres<br />
capacity PVC cistern Florence (Pastel)<br />
make Hindware model no-92122(White)of<br />
approved make necessary bracket, screw<br />
etc. complete with other components like<br />
commode seat and lid, special attachment<br />
for coupling the cistern on the top of EWC,<br />
PVC water connection pipe, 450 mm long<br />
cutting the floor and wall including mending<br />
good the damages, including cost of all<br />
materials as per direction E.I.C. 2 Each No 12908.60 25817.20<br />
28 Providing and installing vitreous china<br />
Orissa pattern water closet pan of Size<br />
58cmx43cm of Hindware cat. No-20070)<br />
with 10lt capacity cistern 100mm SCI P or<br />
S trap complete including cost of all 5 Each No 3838.60 19193.00<br />
CONTRACTOR<br />
46<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
47<br />
materials, all taxes and as per direction of<br />
E.I.C.<br />
29 Providing and installing vitreous china Flat<br />
back Large urinal ( Cat. No-60002, Pastel)<br />
of Hindware with automatic flushing<br />
cistern complete with all required fittings<br />
including cost of all materials as per<br />
direction E.I.C. 2 Each No 7297.30 14594.60<br />
30 Providing and installing vitreous china<br />
Counter Top basin of size 55cmx46cmof<br />
Lara of make Hind ware cat. No-91039<br />
Pastel ) complete including cost of all<br />
materials, all taxes and as per direction of<br />
E.I.C. 6 Each No 5393.60 32361.60<br />
31 Providing and installing vitreous china wash<br />
basin of size 46cmx36cm of WINDSOR of<br />
make Hind ware cat. No-10036 Pastel)<br />
with all fittings complete including cost of<br />
all materials, all taxes complete as per PH<br />
specification & direction of E.I.C. 1 Each No 2873.60 2873.60<br />
32 Providing and fixing Concealed stop cocks<br />
of make JAQUAR cat. No-KUB-35089<br />
(KUBIX) with all fittings complete<br />
including cost of all materials, all taxes<br />
complete as per PH specification &<br />
direction of E.I.C. . . 14 Each No 1528.10 21393.40<br />
33 Providing and fixing Over Head Shower<br />
150mm dia Round Shape Single flow with<br />
Rubit Cleaning system (cat. No OHS-1803)<br />
of JAQUAR with all fittings complete<br />
including cost of all materials, all taxes<br />
complete as per PH specification &<br />
direction of E.I.C. 3 Each No 3250.80 9752.40<br />
34 Providing and fixing of towel ring (cat. No -<br />
AKB-35721 of JAQUAR ) with all fittings<br />
complete including cost of all materials, all<br />
taxes complete as per PH specification &<br />
direction of E.I.C. 4 Each No 1047.00 4188.00<br />
35 Providing and fixing of two way Bib cock<br />
with wall flange (KUBIX ) (cat. No -AKB-<br />
35041 of JAQUAR ) with all fittings<br />
complete including cost of all materials, all<br />
taxes complete as per PH specification &<br />
direction of E.I.C. 8 Each No 1723.70 13789.60<br />
36 Providing and fixing of Florentine Bib cock 1 Each No 1420.70 1420.70<br />
CONTRACTOR<br />
47<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
48<br />
with with Extended lever Handle & wall<br />
flange (cat. No - FLR-5043, Jaquar) with<br />
all fittings complete including cost of all<br />
materials, all taxes complete as per PH<br />
specification & direction of E.I.C.<br />
37 Providing and fixing of click clark waste<br />
32mm size Half Thread with 80 mm height<br />
with wall flange (cat. No -ALD-709 of<br />
JAQUAR ) with all fittings complete<br />
including cost of all materials, all taxes<br />
complete as per PH specification &<br />
direction of E.I.C. 6 Each No 265.00 1590.00<br />
38 Providing and fixing of Soap Dish (cat. No-<br />
AKB-35731 of JAQUAR ) with all fittings<br />
complete including cost of all materials, all<br />
taxes complete as per PH specification &<br />
direction of E.I.C. 15 Each No 921.20 13818.00<br />
39 Providing and fixing of Toilet paper (cat.<br />
No -AKB-35753 of JAQUAR) complete<br />
including cost of all materials, all taxes<br />
complete as per PH specification &<br />
direction of E.I.C. 2 Each No 1148.50 2297.00<br />
40 Providing and fixing of Hand<br />
shower(Health Faucet) with 8mm dia<br />
1metre long Flexible Tube with wall Hook<br />
with NRV (Black Flow Preventer) (cat. No -<br />
ALD-577 of JAQUAR) complete including<br />
cost of all materials, all taxes complete as<br />
per PH specification & direction of E.I.C. 2 Each No 1483.30 2966.60<br />
41 Supply of all materials, labour, T&P , fitting<br />
and fixing in all floors fixed type beveled<br />
plate glass mirror of size 600mm x<br />
450mm x 5.5mm thick best Indian make<br />
,supply of 13mm thick asbestos backing and<br />
CP Brass screw including cost conveyance,<br />
taxes of all materials complete as per PH<br />
specification and direction of Engineer-incharge(Make-Modi<br />
Guard/Belgium) 6 Each No 500.00 3000.00<br />
42 Providing and fixing of Brass/Gun metal<br />
Full way Valve (Leader/Shakti/Laxmi or<br />
equivalent) with C.I. wheel of approved<br />
quality including jointing as per<br />
specification complete including cost of all<br />
materials, all taxes complete as per PH<br />
specification & direction of E.I.C.<br />
CONTRACTOR<br />
48<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
49<br />
a) 50mm dia 4 Each No 2506.90 10027.60<br />
b)25mm dia 7 Each No 647.20 4530.40<br />
43 Providing and fixing of 125 mm dia CP<br />
Grating of approved quality including cost<br />
of all materials, all taxes complete as per<br />
PH specification & direction of E.I.C. 11 Each No 59.35 652.85<br />
44 Providing and fixing Marble Partition (<br />
105cm x 60cm x1.8 cm) using 16mm thick<br />
Marble Tile of approved quality etc.<br />
complete including all fittings complete as<br />
per PH specification and direction of the<br />
Engineer-in-charge. 1.86 Each Sqm 631.20 1174.03<br />
45 Providing and fixing C.P. Glass shelf of<br />
Kubix (cat. No -AKB-35771) of Jaquar with<br />
5mm thick Glass ,fixed to wall including<br />
cutting the wall and making good the<br />
damages, including cost of all materials<br />
complete as per PH specification and<br />
direction of Engineering-in-charge. 3 Each No 1502.00 4506.00<br />
46 Supplying all materials , labour T&P and<br />
fittings required for fixing of NP or CP<br />
Brass or GM fixtures of following sizes and<br />
specification with leak proof threaded<br />
joints tightened with spun yarn and white<br />
zinc or any other method as required as<br />
directed including testing and rectification<br />
of detects, after testing complete as per<br />
direction of Engineer-in-charge.(Make-<br />
Jaquar).<br />
a) Providing and fixing 2’ Single Towel rail<br />
of Kubix (cat. No -AKB-35711) of Jaquar<br />
with all fittings complete including cost of<br />
all materials, all taxes complete as per PH<br />
specification & direction of E.I.C. 3 Each No 1199.00 3597.00<br />
Physically Challanged<br />
47 Providing and fixing Wall mounted Back<br />
Support for Toilet Seat(-Model no-EGBS<br />
020 WH of ENOX )with all fittings<br />
complete with testing including cost of all<br />
materials, labour, all taxes complete as<br />
per PH specification & direction of E.I.C. 1 Each No 16100.00 16100.00<br />
48 Providing and fixing Wall mounted shower<br />
chair with Cushioning Device-(Model no-<br />
EGBS 022 WH of ENOX) with all fittings<br />
complete with testing including cost of all 1 Each No 41650.00 41650.00<br />
CONTRACTOR<br />
49<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
50<br />
materials, labour, all taxes complete as<br />
per PH specification & direction of E.I.C.<br />
49 Providing and fixing Wall mounted Toilet<br />
Handle support for Multi function (Model<br />
no-EGBS 002 WH of ENOX )with all<br />
fittings complete with testing including<br />
cost of all materials, labour, all taxes<br />
complete as per PH specification &<br />
direction of E.I.C. 1 Each No 15750.00 15750.00<br />
50 Providing and fixing Wall mounted<br />
Surface Finger Grip Support Handle<br />
(Model no-EGBS 009 WH-300 of ENOX)<br />
with all fittings complete with testing<br />
including cost of all materials, labour, all<br />
taxes complete as per PH specification &<br />
direction of E.I.C. 1 Each No 2975.00 2975.00<br />
SEPTIC TANK<br />
51 Earthwork in excavation of foundation<br />
trenches in ordinary soil including dressing<br />
of sides and leveling the bed up to the<br />
required depth and depositing the<br />
excavated materials away from the work<br />
site with all leads and lifts, including<br />
shoring, shuttering and dewatering (if<br />
required) with cost of labour, hire &<br />
running charges of water pumps sundries &<br />
T&P required for the work complete as<br />
directed by the Engineer-in-charge. 41.33 Each Cum 39.09 1615.59<br />
52 Supplying and filling in foundation trenches<br />
and plinth, ditches with sand well watered<br />
and rammed in layers not exceeding 23 cm.<br />
In depth with all lead and lift including<br />
cost, conveyance, loading, unloading,<br />
royalties and taxes of all materials, cost of<br />
all labour, sundries, T&P required for the<br />
work etc. complete in all respect as per<br />
specification and direction of Engineer-incharge.<br />
(Measurement will be taken on<br />
finished compacted section only). 3.02 Each Cum 180.80 546.02<br />
53 Providing and lying plain cement concrete<br />
of proportion (1:2:4) in foundation and<br />
floors using Portland Slag Cement(PSC)<br />
with 12 mm. Size black hard crusher<br />
broken granite stone metal and screened<br />
and washed sharp sand for mortar of 2.02 Each Cum 4384.80 8857.30<br />
CONTRACTOR<br />
50<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
approved quality from approved quarry,<br />
washed and cleaned including hoisting,<br />
lowering, laying concrete, ramming,<br />
watering and curing etc. complete to<br />
required levels laid in layers not exceeding<br />
15 cm thick in each layer including cost,<br />
conveyance, loading, unloading, royalties<br />
and taxes all materials and cost all labours,<br />
sundries, T & P required for the work<br />
including shoring, shuttering and<br />
dewatering if required including hire &<br />
running charges of water pump complete as<br />
per specification and direction of<br />
Engineer-in-charge.<br />
54 Providing, lifting, hoisting and laying<br />
Reinforced cement concrete of M-200<br />
grade in plinth protection as per approved<br />
designs and drawings having a minimum<br />
compressive strength (in work test) 200<br />
Kg. / Square cm. in 15 cm. cubes at 28 days<br />
after mixing and test conducted in<br />
accordance with I.S. 516 using 12 mm. to<br />
20 mm. size black hard crushed broken<br />
granite stone chips and screened and<br />
washed sharp sand for mortar of approved<br />
quality from approved quarry, washed and<br />
cleaned ( 20mm. size chips not to exceeds<br />
25 % ) to be mixed in concrete mixture<br />
with Portland slag cement (PSC) including<br />
hoisting, lowering, laying and compaction<br />
concrete by using vibrators, watering and<br />
curing for 28 days, centering and<br />
shuttering then after dismantling and<br />
removing debris from the work site and<br />
finishing the exposed surface smooth<br />
providing grooves or beads wherever<br />
necessary including cost, conveyance,<br />
loading, unloading, royalties and taxes of all<br />
materials and cost of all labours, sundries,<br />
T & P required of the work etc. complete in<br />
all respect as directed by the Engineer-in-<br />
Charge. But excluding cost and conveyance<br />
of M.S. rods or Tor steel and binding wires<br />
and labour charges for straightening,<br />
cutting, bending etc. of M.S. rods or tor<br />
51<br />
CONTRACTOR<br />
51<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
52<br />
steel tying the grills and placing in proper<br />
position.<br />
a) Raft 1.89 Each Cum 4465.10 8439.04<br />
b)Wall 5.75 Each Cum 6206.40 35686.80<br />
c) Roof slab 1.26 Each Cum 6639.90 8366.27<br />
55 Providing, fixing and placing of MS bars/<br />
Tor steel (HYSD)(TATA/SAIL) for RCC<br />
work of required diameter of approved<br />
quality with straightening, Cutting,<br />
bending, binding welding or jointing if<br />
necessary, bending, binding, tying the grills<br />
as required for R.C.C. works, providing fan<br />
hoocks where necessary and hoisting,<br />
lowering and placing in proper position<br />
according to approved designs and<br />
drawings including cost, conveyance,<br />
loading, unloading, taxes of M.S. rods or<br />
Tor steel and binding wires of 18 to 20<br />
gauge required for the work and cost of all<br />
labour, sundries, T & P and scaffolding<br />
complete in all respect as directed by the<br />
Engineer-in-Charge ( payment will be made<br />
according to the actual weight of M.S rod<br />
/Tor steel consumed in the work and no<br />
separate payment will be made towards<br />
weight of binding wires which is to be<br />
borne by the contractor at his own cost 8.04 Each Qntl 6270.40 50414.02<br />
56 Providing 12mm. thick cement plaster with<br />
cement mortar of mix (1:4) in all floors<br />
with Portland slag cement (PSC) and with<br />
screened and washed sharp sand for<br />
mortar with neat cement punning for<br />
skirting finished smooth to brick walls in<br />
dadoes and skirting after racking out the<br />
joints including watering and curing<br />
complete with cost, conveyance, loading<br />
and unloading, royalties and taxes of all<br />
materials, cost of all labour, sundries, T&P,<br />
scaffolding required for the work etc.<br />
complete in all respect as directed by the<br />
Engineer-in-Charge. 32.04 Each Sqm 83.80 2684.95<br />
57 Providing 20mm OMS step iron as per<br />
design and drawing complete including cost<br />
conveyance, taxes of all materials, labour,<br />
T & P, loading and unloading etc. complete 11 Each No 150.00 1650.00<br />
CONTRACTOR<br />
52<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
53<br />
as per specification and direction of<br />
Engineer-in-charge.<br />
58 Making soak pit 1.2m diameter 2.59 m deep<br />
with 45x45 cm dry brick honey comb<br />
shaft with bricks of class designation 75<br />
and S.W. drain pipe 100 mm diameter ,1.8<br />
m long complete as per standard design.<br />
With F.P.S. brick including cement<br />
concrete cover etc. completein all respect<br />
with all cost, conveyance, royalties, loading<br />
& unloading & tax of all materials and cost<br />
of all labour, sundries, T & P required for<br />
the work including hoisting, lowering,<br />
dewatering if required etc. complete in all<br />
respect as directed by Engineer-in charge. 3 Each No 9900.00 29700.00<br />
59 Supplying all materials, labours, T&P and<br />
constructing gully trap chamber of<br />
250mmx250mm inside size with 8cm thick<br />
RCC precast cover slab in cement concrete<br />
(1:2:4) mix using 12mm size hg chips,<br />
foundation concrete (1:4:8) using 40mm<br />
size hard granite metal on bed and around<br />
trap, KB brickwork in cement mortar (1:6)<br />
in F&P and inside 12mm thick cement<br />
plaster in cement mortar (1:3) finished<br />
with a floating coat of neat cement<br />
including fixing 100mmx100mm size HCI<br />
gully trap,150mm x150mm size CI grating<br />
etc all complete as per approved drawing,<br />
PH specification and direction of Engineerin-charge.<br />
10 Each No 903.70 9037.00<br />
60 Constructing brick masonary Manhole<br />
chamber with 75 class designation bricks<br />
in cement mortar 1:4 (1 cement :4 coarse<br />
sand) R.C.C top slab with 1:2:4mix(1<br />
cement:2 coarse sand :4 graded stone<br />
aggregate 20 mm nominal size, foundation<br />
concrete 1:4:8 (1 cement:4 coarse sand : 8<br />
graded stone aggregate 40 mm nominal<br />
size) inside plastering 12 mm thick with<br />
cement mortar 1:3(1 cement :3 coarse sand<br />
) finished with floating oat of neat cement<br />
and making channels in cement concrete<br />
1:2:4 (1 cement :2 coarse sand :4 graded<br />
stone aggregate 20 mm nominal size ) 15 Each No 6141.90 92128.50<br />
CONTRACTOR<br />
53<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
54<br />
finished with a floating coat of neat<br />
cement complete as per standard design.<br />
Inside dimensions 900 mmx900mmx750mm<br />
deep including C I cover with frame (light<br />
duty 455x610 mm internal dimensions total<br />
weight of cover and frame to be not less<br />
than 38 kg ( weight of cover 23 kg and<br />
weight of frame 15 kg) /RCC Precast Slab<br />
with F P S brick. as per approved drawing,<br />
PH specification and direction of Engineerin-charge.<br />
61 Providing and fixing 2000 litres capacity<br />
P.V.C Over head (Sintex make)tank over<br />
RCC(1:1.5:3) Staging with all piping and<br />
valve arrangement with all labour &<br />
materials ,including cost, T&P , scaffolding<br />
etc., complete as directed by the Engineerin-charge.<br />
2 Each No 11000.00 22000.00<br />
ELECTRICAL WORK<br />
62 Recessed wiring to light point with 1.5<br />
sq.mm FR PVC insulated single core<br />
multistrand copper conductor of ISI<br />
marked with 20 mm dia non-metallic PVC<br />
flexible conduit with S.P. 5 / 6 amps, one<br />
way modular switch, ISI marked type<br />
switch, Modular base & cover for 1 module,<br />
Modular G.I. box for 2 module 18 SWG ISI<br />
marked and ceiling rose ISI marked<br />
mounted on MS box having front Bakelite<br />
cover of suitable size , MS box with 1.5<br />
sq.mm FR PVC insulated single core multi<br />
strand copper conductor as earth wire<br />
including all accessories and connection as<br />
per direction of Engineer in Charge. ( Make<br />
of wire Finolex/ L&T / Anchor / Havels / V<br />
Guard )<br />
Group-A 10 Each No 467.00 4670.00<br />
Group-B 12 Each No 566.00 6792.00<br />
Group-C 12 Each No 700.00 8400.00<br />
63 Recessed wiring to ceiling fan point with<br />
1.5 sq.mm FR PVC insulated single core<br />
multi strand copper conductor of ISI<br />
marked with 20 mm dia non-metallic PVC<br />
flexible conduit with S.P. 5 / 6 amps, one<br />
way modular switch, ISI marked type<br />
CONTRACTOR<br />
54<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
55<br />
switch, Modular base & cover for 1 module,<br />
Modular G.I. box for 2 module 18 SWG ISI<br />
marked and ceiling rose ISI marked<br />
mounted on MS box having front Bakelite<br />
cover of suitable size , MS box with 1.5<br />
sq.mm FR PVC insulated single core multi<br />
strand copper conductor as earth wire<br />
including all accessories and connection as<br />
per direction of Engineer in Charge. ( Make<br />
of wire Finolex/ L&T / Anchor / Havels / V<br />
Guard )<br />
Group-B 6 Each No 566.00 3396.00<br />
Group-C 6 Each No 1063.00 6378.00<br />
64 Recessed wiring to exhaust fan point with<br />
1.5 sq.mm FR PVC insulated single core<br />
multistrand copper conductor of ISI<br />
marked with 20 mm dia non-metalic PVC<br />
flexible conduit with S.P. 5 / 6 amps, one<br />
way modular switch, ISI marked type<br />
switch, Modular base & cover for 1 module,<br />
Modular G.I. box for 2 module 18 SWG ISI<br />
marked and ceiling rose ISI marked<br />
mounted on MS box having front Bakelite<br />
cover of suitable size , MS box with 1.5<br />
sq.mm FR PVC insulated single core<br />
multistrand copper conductor as earth wire<br />
including all accessories and connection as<br />
per direction of Engineer in Charge. ( Make<br />
of wire Finolex/ L&T / Anchor / Havels / V<br />
Guard ) including cost, all taxes complete in<br />
all respect as per specification and<br />
direction of Engineer-in-charge<br />
Group-A 9 Each No 467.00 4203.00<br />
65 Recessed wiring to submain in 2 x 2.5<br />
sq.mm FR PVC insulated single core<br />
multistrand copper conductor of ISI<br />
marked confirming to IS-694/1990 in 20<br />
mm dia non-metallic heavy duty flexible<br />
conduit 1.6 mm thick along with 1 x 1.5<br />
sq.mm FR PVC insulated single core<br />
multistrand copper conductor as earth wire<br />
as required.(Make of wire<br />
Finolex/L&T/Anchor/Havels/V Guard)<br />
including cost, all taxes complete in all<br />
respect as per specification and direction 150.00 Each Mtr 96.00 14400.00<br />
CONTRACTOR<br />
55<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
56<br />
of Engineer-in-charge<br />
66 Recessed wiring for power plug with 2 x 4<br />
sq.mm FR PVC insulated single core multi<br />
strand copper conductor of ISI marked<br />
with 20 mm dia non-metallic PVC flexible<br />
conduit along with 1 x 2.5 sq.mm FR PVC<br />
insulated single core multistrand copper<br />
conductor for loop earthing as required. (<br />
Make of wire Finolex / L&T /Anchor /<br />
Havels / V Guard ) including cost, all taxes<br />
complete in all respect as per specification<br />
and direction of Engineer-in-charge 120.00 Each Mtr 133.00 15960.00<br />
67 Recessed wiring for power plug with 4<br />
x6sq.mm FR PVC insulated single core multi<br />
strand copper conductor of ISI marked<br />
with 20 mm dia non-metallic PVC flexible<br />
conduit / casing caping along with 1 x 2.5<br />
sq.mm FR PVC insulated single core multi<br />
strand copper conductor for loop earthing<br />
as required. ( Make of wire Finolex / L&T<br />
/Anchor / Havels / V Guard ) 15.00 Each Mtr 275.00 4125.00<br />
68 Recessed wiring for power plug with 2<br />
x6sq.mm FR PVC insulated single core<br />
multistrand copper conductor of ISI<br />
marked with 20 mm dia non-metallic PVC<br />
flexible conduit / casing caping along with 1<br />
x 2.5 sq.mm FR PVC insulated single core<br />
multistrand copper conductor for loop<br />
earthing as required. ( Make of wire<br />
Finolex / L&T /Anchor / Havels / V Guard ) 15.00 Each Mtr 156.50 2347.50<br />
69 Point wiring for 5 / 6 amp mudolar socket<br />
outlet with 2 x 1.5 sq.mm FR PVC insulated<br />
single core multi strand copper conductor<br />
of ISI marked in recess 20 mm dia nonmetallic<br />
PVC flexible conduit with modular<br />
type switch ,phenolic laminated sheet<br />
suitable size ISI marked MS box and<br />
earthing point with 1 x 1.5 sq.mm FR<br />
PVCinsulated single core multistrand<br />
copper conductor for loop earthing etc. as<br />
required. ( Make of wire Finolex /L&T /<br />
Anchor / Havels / V Guard ) 8 Each No 652.00 5216.00<br />
70 Supply and fixing a set of 1 no modular grid<br />
plate mounted 240 volt 6 amp 4 pin<br />
universal round/flat pin combined 6 Each No 463.00 2778.00<br />
CONTRACTOR<br />
56<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
57<br />
shuttered socket outlet with 240 volt 6<br />
amp control switch, all housed in a 3 module<br />
recessed zinc chromate passivated MS box<br />
including moulded cover plate etc. complete<br />
as required.<br />
71 Supply and fixing a set of 1 no modular grid<br />
plate mounted 240 volt 6/16 amp 4 pin<br />
universal round/flat pin combined<br />
shuttered socket outlets each with 240<br />
volt 16 amp control switch, all housed in a<br />
single 4 module recessed zinc chromate<br />
passivated MS box including one moulded<br />
cover plate etc. complete as required. 2 Each No 632.00 1264.00<br />
72 Supplying and fixing of 15A /16A Modular<br />
Switch with 4 Modular metal box with<br />
cover of in Recess including providing and<br />
fixing connection, etc as required.(For<br />
plugs to be used in non residential<br />
buildings) including cost, all taxes complete<br />
in all respect as per specification and<br />
direction of Engineer-in-charge 4 Each No 354.00 1416.00<br />
73 Supplying and fixing of 15A /16A Modular<br />
socket with 4 Modular metal box with<br />
cover of in Recess including providing and<br />
fixing connection, etc as required.(For<br />
plugs to be used in non residential<br />
buildings) including cost, all taxes complete<br />
in all respect as per specification and<br />
direction of Engineer-in-charge 4 Each No 414.00 1656.00<br />
74 Supply, Installation, Testing, and<br />
commissioning of ceiling fan 1200 mm<br />
sweep 230/250 volts, 50HZ complete with<br />
suitable, clamp, down rod, blades, canopy,<br />
rubber, shackle, and connections with 1.5<br />
sq.mm PVC insulated copper conductor<br />
cable etc as required. ( Havells SS 390/<br />
Equivalent) 12 Each No 2601.00 31212.00<br />
75 Supply, Installation, Testing, and<br />
commissioning of Exhaust fan 250mm dia<br />
900mm suitable to work on 230/250 volts,<br />
50HZ complete with mounting frame and<br />
louvers including making the hole to suit<br />
the size of above fan, making good the<br />
damage, connections, with 1.5 sq.mm PVC<br />
insulated, copper conductor, single core 9 Each No 1809.00 16281.00<br />
CONTRACTOR<br />
57<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
58<br />
cable etc including all accessories and<br />
connection as per direction of Engineer in<br />
Charge.<br />
76 Supplying & fixing of15W CFL TARNADO<br />
(Philips) etc. complete. 16 Each No 210.00 3360.00<br />
77 Supply & Fixing of 1 x 28 watt T5 4' long<br />
flouroscent tube light fitting on wall<br />
surface complete with 1 no of 28 watt T5<br />
tube of approved make complete with all<br />
other necessary fixing materials including<br />
termination and labour.(Make : Phillips /<br />
Equivalent) 15 Each No 957.00 14355.00<br />
78 Supply & fixing of 4 way, Triple pole and<br />
Neutral, sheet steel MCB double door<br />
distribution box complete with tinned<br />
copper busbar, neutral link, earth bar, din<br />
rail, detachable gland plate including 1 no.<br />
of 63A TPN MCB as I/C , 8 no. of 6/10<br />
Amps, 10kA rating, 240Volts, Single pole<br />
Miniature Circuit Breaker in each phase as<br />
O/G of approved make complete with<br />
connections, testing and commissioning &<br />
all other required materials etc including<br />
all accessories and connection as per<br />
direction of Engineer in Charge. 1 Each No 5242.00 5242.00<br />
79 Supply & fixing of 2 way, Single pole and<br />
Neutral, sheet steel MCB double door<br />
distribution box complete with tinned<br />
copper busbar, neutral link, earth bar, din<br />
rail, detachable gland plate including 1 no.<br />
of 63A TPN MCB as I/C , 10no. of 6/10<br />
Amps, 10kA rating, 240Volts, Single pole<br />
Miniature Circuit Breaker in each phase as<br />
O/G of approved make complete with<br />
connections, testing and commissioning &<br />
all other required materials etc including<br />
all accessories and connection as per<br />
direction of Engineer in Charge. 1 Each No 3763.00 3763.00<br />
80 Providing and making earth pits including<br />
the cost of 2mm thick 2.5 mtr. long 50 mm<br />
dia pipe, CI funnel with wire mesh charcoal,<br />
salt, all earth work, masonry enclosure with<br />
CI frame & 300 mm x 300 mm cover plate<br />
having locking arrangement complete as per<br />
IS 3043:1987 for LT Panel including all 2 Each No 3000.00 6000.00<br />
CONTRACTOR<br />
58<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
59<br />
accessories and connection as per direction<br />
of Engineer in Charge.<br />
81 Supplying and laying of the following<br />
earthling clamped to wall with suitable<br />
clamps saddles and fixing bolts/ in ground<br />
including the cost of digging and back<br />
filling with sand and brick protection as<br />
required and complete as required including<br />
all accessories and connection as per<br />
direction of Engineer in Charge.<br />
19 mm x 3 mm GI strip 25.00 Each Mtr 79.50 1987.50<br />
82 Supply & lying with following 1.1 kv grade<br />
XLPE / PVC insulated, PVC sheathed AYFY<br />
Al conductor cable of approved make in<br />
existing cable trance / direct laying<br />
complete with dressing etc along with<br />
other necessary materials and labour<br />
including all accessories and connection as<br />
per direction of Engineer in Charge.<br />
3.5c x 25 sq.mm 1.1kv grade AYFY AL.<br />
cable 50.00 Each Mtr 322.00 16100.00<br />
83 Supply , Installation, testing &<br />
commissioning of the following indoor wall<br />
mounted type L.T Distribution panel board<br />
of 415V , 50Hz. Power supply made out of<br />
1.6mm thick CRCA steel duly de rusted &<br />
painted with two coats of light grey &<br />
enamel paint of approved shade over a coat<br />
of primer, dust, damp & vermin proof,<br />
cubicle fixed on M.S angle channel base,<br />
having compartmental arrangement for<br />
each equipment and suitable size of<br />
Aluminium bus bar having provision for<br />
cable entry at bottom, providing Earthling<br />
point to terminate 19mm x 3mm G.I flat,<br />
Nomenclature plate, Enameled danger<br />
board, earthling studs as per specification<br />
mentioned below duly factory wired<br />
confirming to the relevant ISS including all<br />
accessories and connection as per direction<br />
of Engineer in Charge.<br />
a)One no of 200Amp 16kA 4P MCCB.<br />
b)1 set of 3 ph. 25 x 6 mm size cu. Bus bar<br />
(250A)<br />
c)One no of 63Amp 4P Change over.<br />
CONTRACTOR<br />
59<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
60<br />
d)1 set of 3 ph. 25 x 6 mm size cu. Bus bar<br />
(100A)<br />
e)3 nos. of 100 Amp TPN MCB.<br />
f)3 nos. of 32 Amp TPN MCB.<br />
The panel board should contain Toggle<br />
switch, 3 ph.(R,Y,B) Indicator, Voltmeter<br />
(0-500v), Ammeter (0-100A) with Selector<br />
Switch & 3 nos. of 100/5 A CT of<br />
approved make should be fixed in wall at a<br />
suitable place along with other necessary<br />
materials and labour. 1 Each No 48500.00 48500.00<br />
84 Supply , Installation, testing &<br />
commissioning of 9mtr long tubular pole of<br />
size 5''x4''x3'' with round type head<br />
braket of 2''dia GI Bracket with provison<br />
for 4nos light fittings as per approved<br />
make & Model as per specification and<br />
direction of Engg –in- Charge. 3 Each No 25000.00 75000.00<br />
85 Supply , Installation, testing &<br />
commissioning Non integral floodlight<br />
luminaries with pressure die cast aluminium<br />
housing and heat resistant toughened flat<br />
glass (IP 65) complete with external single<br />
CG BoxRVP302 2xSONT400W*<br />
2xSONT400W (Phillips) as per approved<br />
make & Model as per specification and<br />
direction of Engg –in- Charge. 12 Each No 15500.00 186000.00<br />
86 Supply of 10 sq.mm 2 core PVC Armoured<br />
Cables ISI Marked as per approved make &<br />
Model as per specification and direction of<br />
Engg –in- Charge. 300.00 Each Mtr 115.00 34500.00<br />
87 Laying of one number of PVC insulated and<br />
PVC seatheled / XLPE power cable of 1.1<br />
KV grade of size not exceeding 25 sq.mm<br />
direct in ground including excavation, sand<br />
Cushing, protective covering and refilling<br />
the trench etc. as required. 300.00 Each Mtr 75.00 22500.00<br />
88 Supply and installation of Floor type<br />
outdoor panel board 100 AMP DP Switch<br />
and 100A DP CUPPER BUS BAR ISI<br />
Marked as per approved make & Model as<br />
per specification and direction of Engg –in-<br />
Charge. 1 Each No 15000.00 15000.00<br />
DEEP TUBE WELL<br />
89 Labour for drilling a perfectly bore hole<br />
CONTRACTOR<br />
60<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
61<br />
for specified dia for specified depth below<br />
G.L through consolidated and<br />
unconsolidated rocks with fast drilling<br />
sophisticated DTH/combination rig to suit<br />
the site condition as per the direction of<br />
the Engineer-in-charge including use of<br />
own Rigs with it accessories, T&P<br />
consumables etc.,for lowering of 200mm<br />
dia GI/PVC pipe for housing fitted with<br />
socket and with or without well screen as<br />
per necessity for soft , medium, hard &<br />
boulder formation (GI/PVC/MS casing pipe<br />
if required to prevent collapse of over<br />
burden is to be provided by the contractor<br />
including lowering and withdrawing after<br />
completion of Tube well) 200mm doa to<br />
400mm dia in overburden portion including<br />
packing of gravel etc. complete as per<br />
direction of Engineer-in-charge.<br />
a) 200 mm dia<br />
1) 0 Mtr to 30 Mtr 30.00 Each Mtr 748.00 22440.00<br />
2) 30 Mtr to 164 Mtr 134.00 Each Mtr 828.00 110952.00<br />
90 Lowering the following size of G.I.<br />
/PVC/MS housing pipe with or without<br />
slotted pipes as per the necessity from<br />
ground level up to 45mtr depth fitted and<br />
fixed up in perfectly vertical position<br />
including cutting & threading of pipes &<br />
slotted pipes & supplying & fixing all<br />
jointing materials, tools & plant etc. all<br />
complete & keeping the top of casing pipe<br />
threaded including plugging tube-wells to<br />
prevent entry of foreign materials and<br />
keeping the casing pipe 1.00mtr above GL.<br />
etc. complete as per direction of Engineerin-charge.<br />
a) 200 mm dia<br />
1) 0 Mtr to 30 Mtr 30.00 Each Mtr 76.00 2280.00<br />
2) 30 Mtr to 120 Mtr 90.00 Each Mtr 99.00 8910.00<br />
91 Cleaning and developing the tube well with<br />
their own compressor continuously worked<br />
till clear and adequate discharge is<br />
obtained from the tube well including<br />
supply and use of all necessary equipments<br />
and labour as per direction of Engineer-in- 1 Each No 2895.00 2895.00<br />
CONTRACTOR<br />
61<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
62<br />
charge.<br />
92 Supplying all materials, labour, T&P and<br />
providing sanitary sealing by cement<br />
concretes grouting of annular space around<br />
G.I./PVC/M.S. Housing pipe up to 5 meters<br />
below G.L. to plug the bore including cost<br />
of cement etc all complete as per the<br />
direction of Engineer-in-charge minimum<br />
one mtr casing pipe to be inserted in the<br />
bore into the rock at the bottom to ensure<br />
sanitary sealing. 1 Each No 999.00 999.00<br />
93 Supplying all materials, labour, T&P for<br />
fitting and fixing of PVC casing pipe<br />
(ASTM D 1785 Sch-80) of following dia<br />
with socket including cost of all materials,<br />
all taxes, all labour, transportation to sites<br />
etc. complete as per PH specification &<br />
direction of Engineer-in-charge<br />
(Oriplast/Finolex or Equivalent).<br />
150 mm dia PVC Pipes 120.00 Each Mtr 1030.00 123600.00<br />
94 Supplying fitting, fixing of 5.00 HP<br />
submersible pump TEXMO Make ( model<br />
No: TRF -2025S+SF037) or Equivalent<br />
including cost of all materials,<br />
transportation and taxes of pump etc.<br />
complete as per PH specification &<br />
direction of Engineer-in-charge. 1 Each Set 24450.00 24450.00<br />
95 Supplying all materials, labour, T&P for<br />
fitting and fixing of required control panel<br />
of approved quality including DOL starter<br />
with indicator 32 Amp TPN main switch<br />
including connection, installation etc. all<br />
complete as per specification & direction<br />
of Engineer-in-charge. 1 Each Set 2250.00 2250.00<br />
96 Supplying, fitting and fixing of 3core flat<br />
industrial cable for submission conforming<br />
to IS 694 Flexible 1100V. To IS 694.<br />
including all cost of material, labour, T&P<br />
etc all complete.(Make:Havels/ Finolex or<br />
Equivalent. 80.00 Each Mtr 139.60 11168.00<br />
97 Supplying all materials, labour, T&P for<br />
fitting and fixing of HDPC pipe of approved<br />
quality as directed by Engineer-in – charge.<br />
a) 40 mm dia HDPC Pipes 45.00 Each Mtr 63.00 2835.00<br />
98 Supplying, fitting, fixing of S.S tapper 1 Each Set 1600.00 1600.00<br />
CONTRACTOR<br />
62<br />
Sr.DIVISIONAL MANAGER (B.P.)-I
63<br />
2nos of 0.45mtr long M.S supporting<br />
clamps with M.S nuts & bolt and 200mm<br />
tube well cover & cap suitable for the<br />
above pump sets.<br />
Total-Rs. 49,79,240.06<br />
Say Rs. 49,79,000.00<br />
(Rupees Forty nine lakh Seventy nine thousand) only.<br />
Total: 98 (Ninety eight) Items only.<br />
N.B: The tenderer is required to quote only the percentage excess or less over the<br />
estimated cost here-below both in words and figures:<br />
( )<br />
(In figures)<br />
(In words)<br />
NO. OF CORRECTIONS ………………………IN ITEM NO………………….<br />
NO. OF OVERWRITING……………………….IN ITEM NO…………………<br />
NO. OF INTERPOLATIONS…………………IN ITEM NO………………….<br />
CONTRACTOR<br />
63<br />
Sr.DIVISIONAL MANAGER (B.P.)-I