Reversing Headers<br />
12<br />
Reversible Inlet/Outlet Connection<br />
The MiniMax <strong>NT</strong> <strong>Series</strong> heater is factory assembled<br />
with right side inlet/outlet water connections. The<br />
inlet/outlet header can be reversed for left side water<br />
connections without removing the heat exchanger.<br />
Reversing Water Connections<br />
Tools required:<br />
Phillips Screw Driver<br />
9/16 in. Socket and Wrench<br />
1/2 in. & 9/16 in. Open Wrench<br />
NOTE<br />
Do NOT remove the high-limit and pressure<br />
switches or the thermistor from the front header<br />
during the reversing procedure, as they will be in<br />
the proper location when installed on the left side.<br />
3. Disconnect the pressure switch wiring.<br />
4. Disconnect the temperature sensor wires from<br />
the circuit board and feed them back to the<br />
header.<br />
1. Remove the right and left large inspection plates.<br />
It is not necessary to remove the top of the<br />
heater to gain access to the headers.<br />
2. Disconnect all wires from the high-limit<br />
switches except the short jumper wire.<br />
5. Remove the 8 bolts holding the main inlet/outlet<br />
head.<br />
P/N <strong>NT</strong>SM03 Rev. B 2-11-04