18.05.2014 Views

MiniMax® NT Series - Pentair

MiniMax® NT Series - Pentair

MiniMax® NT Series - Pentair

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation (Gas Line)<br />

8<br />

Pipe Sized For Length Of Run In Equivalent Feet<br />

MODEL<br />

NAT<br />

PIPE SIZING FOR GAS LINE CONNECTIONS<br />

MAXIMUM EQUIVALE<strong>NT</strong> PIPE LENGTH<br />

Natural gas at 1000 B.T.U. per Cubic Foot<br />

Propane Gas at 2500 B.T.U. per Cubic Foot<br />

Table 1.<br />

1 /2” 3 /4”<br />

1 ” 1 -1/4”<br />

1 -1/2”<br />

2 ” 2-1/2”<br />

PRO<br />

NAT<br />

PRO<br />

NAT<br />

PRO<br />

NAT<br />

PRO<br />

NAT<br />

PRO<br />

NAT<br />

PRO<br />

200<br />

- 20’<br />

30’<br />

80’<br />

125’<br />

250’<br />

450’<br />

600’<br />

- - - - - -<br />

250<br />

- 10’<br />

20’<br />

50’<br />

70’<br />

150’<br />

250’<br />

500’<br />

600’<br />

- - - - -<br />

300<br />

- - 10’<br />

30’<br />

50’<br />

100’<br />

200’<br />

350’<br />

400’<br />

600’<br />

- - - -<br />

400<br />

- - - 10’<br />

20’<br />

60’<br />

100’<br />

150’<br />

200’<br />

450’<br />

400’<br />

- - -<br />

NAT<br />

PRO<br />

“RESIDE<strong>NT</strong>IAL” PROPANE 2 STAGE REGULATION<br />

In many Propane gas line installations, the gas supplier and/or installer will utilize a two stage regulation process<br />

where by at the supply tank they will install the first stage gas regulator, which would be at a higher pressure, usually<br />

10 psi. This higher pressure allows for a much longer distance and in a much smaller pipe size. Then within a short<br />

distance of the pool heater, usually around 24 inches, they will install a second regulator, which is the second stage,<br />

and this would be set at the required inlet pressure of the heater.<br />

See “Gas Pressure Requirement Charts”<br />

Stage One "High Pressure" Gas Pipe Sizing<br />

10 PSI @ 2500 B.T.U. Per CU. FT.<br />

MAXIMUM EQUIVALE<strong>NT</strong> PIPE LENGTH<br />

M odel 0 to 50 Ft.<br />

50<br />

to 100 Ft.<br />

100 to 150 Ft.<br />

75<br />

through 400 1 /2 in.<br />

1 /2 in.<br />

1/2 in.<br />

Stage Two "Low Pressure" Gas Pipe Sizing<br />

Stage 2 set at 14 in. W.C.<br />

MAXIMUM EQUIVALE<strong>NT</strong> PIPE LENGTH<br />

M odel 0 to 10 Ft.<br />

10 to 20 Ft.<br />

75<br />

through 400 3 /4 in.<br />

3/4 in.<br />

Table 2. Table 3.<br />

“RESIDE<strong>NT</strong>IAL” NATURAL GAS 2 STAGE REGULATION<br />

In many Natural gas line installations, the gas supplier and/or installer may utilize a two stage regulation process<br />

where by at the streets main gas supply they will install the first stage gas regulator, which would be at a higher<br />

pressure. This higher pressure is usually set at 2 psi or 5 psi and can be for long distances and in a much smaller pipe<br />

size. Then within a short distance of the pool heater, generally around 24 inches, they will install a second regulator,<br />

which is the second stage. This second stage regulator would be set at the minimum operating pressure for the heater.<br />

For “Natural Gas <strong>Pentair</strong> Pool Heaters” the minimum is 7 inches W.C.<br />

See “Gas Pressure Requirement Charts”<br />

Stage One "High Pressure" Gas Pipe Sizing<br />

2 PSI @ 1000 B.T.U. Per CU. FT.<br />

MAXIMUM EQUIVALE<strong>NT</strong> PIPE LENGTH<br />

M odel 0 to 50 Ft.<br />

50<br />

to 100 Ft.<br />

100 to 150 Ft.<br />

75<br />

through 300 1 /2 in.<br />

1 /2 in.<br />

1/2 in.<br />

350<br />

& 400 3 /4 in.<br />

3 /4 in.<br />

3/4 in.<br />

5 PSI @ 1000 B.T.U. Per CU. FT.<br />

75<br />

through 400 1 /2 in.<br />

1 /2 in.<br />

1/2 in.<br />

Stage Two "Low Pressure" Gas Pipe Sizing<br />

Stage 2 set at 7 in. W.C.<br />

MAXIMUM EQUIVALE<strong>NT</strong> PIPE LENGTH<br />

M odel 0 to 10 Ft.<br />

10 to 20 Ft.<br />

75<br />

through 300 3 /4 in.<br />

3/4 in.<br />

350<br />

& 400 3 /4 in.<br />

1 in.<br />

Stage 2 set at 7 in. W.C.<br />

75<br />

through 400 3 /4 in.<br />

1 in.<br />

Table 4. Table 5.<br />

P/N <strong>NT</strong>SM03 Rev. B 2-11-04

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!