Basic System Operation<br />

22<br />

TO OPERATE HEATER<br />

1. Start pump, make sure the pump is running and is primed, to close water pressure switch and<br />

supply power to heater. Be sure the pool and/or spa is properly filled with water.<br />

2. Follow the Lighting/Operating instructions on the following page.<br />

FIRING SEQUENCE<br />

1. Pump on.<br />

2. Heater on.<br />

3. T-stats call for heat.<br />

4. Pre-purge for 15 seconds (clears combustion chamber of combustible gas).<br />

5. Hot surface igniter heat up time of 40 seconds.<br />

6. Main valve opens for 7 seconds for flame rectification.<br />

7. Heater runs until desired temperature is reached.<br />

8. Gas valve closes and fan runs for 45 seconds to cool combustion chamber.<br />

IGNITION FAILURE<br />

1. If flame is not rectified in 7 seconds or less the heater goes into pre-purge for 15 seconds, then starts<br />

the ignition sequence again.<br />

2. After 3 attempts, the heater goes into hard lock<br />

out for 1 hour and tries over again.<br />

(Note: The fan will stay running during lockout.)<br />

3. To get out of the 1 hour lock out you must<br />

de-energize the heater by cutting power either<br />

with the pool / spa rocker switch or internal<br />

rocker switch.<br />

HARD LOCK OUT<br />

❖ Lock out can occur under the following condition:<br />

I<strong>NT</strong>ERNAL ROCKER SWITCH<br />

1. Heater has failed to fire on three attempts.<br />

(Under J-Box)<br />

❖ When a lock out occurs the heater shows a<br />

service light, no heat light, and the exhaust fan stays running until the one hour time out has expired.<br />

At that point the heater will attempt to fire three more times. It is important to discover why the lock<br />

out has occurred before you attempt to reset the control board.<br />

P/N <strong>NT</strong>SM03 Rev. B 2-11-04