40<br />

Troubleshooting<br />

THE SERVICE LIGHT<br />

1. The primary responsibility for the SERVICE Light is to illuminate whenever there is a problem<br />

that prevents the heater from firing (please see Diagnostic Lights explanation at the beginning of<br />

this section). However, it will also be ON during the Fan 15-second pre-purge and the 40-second<br />

Hot Surface Igniter heat up.<br />

2. The SERVICE Light also comes ON if the burners do not continue to burn properly or if the<br />

flame goes out, if there is a bad Flame Sensor or Flame Sensor wire or if anything else causes the<br />

Ignition Module to restart the ignition sequence. So, if the SERVICE Light comes ON and heater<br />

stops firing and then the heater fires and the SERVICE Light goes out, simulating a Rapid Cycle,<br />

it can be caused by a loss of or weak signal to the Ignition Module by the Flame Sensor.<br />

3. The SERVICE Light will come ON if the water temperature in the Inlet side of the Header<br />

reaches 115 degrees or if the water temperature at the outlet of the heat exchanger reaches 150<br />

degrees. If the heater is cycling in this mode, the three green lights on the back of the Control<br />

Board will flash OFF and ON as the heater shuts down and refires.<br />

NOTE<br />

If a weak Flame Sensor signal causes the cycling, the SERVICE Light will go ON and OFF, but<br />

the High Limit Light will remain ON. If water temperature causes the cycling, the SERVICE Light<br />

will go ON and OFF AND the High Limit will go ON and OFF as well.<br />

OUT<br />

EXT SWITCH<br />

RETURN<br />

POOL<br />

POTE<strong>NT</strong>IOMETER<br />

24 VAC PRESS HILMT TFUSE VALVE IGNITION MOD<br />

MODEL 6800<br />

ELECTRONIC THERMOSTAT<br />

SPA COM POOL<br />

TPROBE<br />

SPA<br />

POTE<strong>NT</strong>IOMETER<br />

PVALV LED<br />

TFUSE LED<br />

HITEMP LED<br />

Figure 36.<br />

FRO<strong>NT</strong> PANEL<br />

POOL / OFF/SPA<br />

THERMOSTAT SELECT SWITCH<br />

P/N <strong>NT</strong>SM03 Rev. B 2-11-04