Air Requirements (Indoor)<br />

16<br />

vent terminated at least 24"<br />

above any object within 10 ft.<br />

More Than10 ft.<br />

Ridge<br />

Cap<br />

2 ft. min.<br />

;;Vent<br />

3 ft. min.<br />

J<br />

Detail H<br />

;;<br />

K<br />

Roof<br />

L Jack<br />

Chimney<br />

Vent for roof penetration installations:<br />

J<br />

must extend at least 3 ft. higher than the<br />

point at which it passes through the roof,<br />

or as permitted by local code.<br />

K<br />

must use a double-wall vent pipe through<br />

the roof penetration.<br />

L<br />

must terminate with an approved (listed)<br />

roof jack, storm collar, and vent/weather cap.<br />

Vent pipe extension:<br />

must be the same diameter as the<br />

vent connector.<br />

A<br />

B<br />

C<br />

must be suitable for use with category III<br />

appliances which have flue gas temperatures<br />

of less than 400 deg. F.<br />

may use a single wall vent pipe with<br />

permanently sealed seams and joints.<br />

G<br />

INDOOR INSTALLATIONS<br />

MINIMAX <strong>NT</strong> VE<strong>NT</strong>ING GUIDELINES<br />

H<br />

E<br />

Air Supply<br />

Ventilation<br />

F<br />

1' min.<br />

F<br />

1' min.<br />

Vent Hood<br />

Vent Hood<br />

A<br />

4'<br />

7'<br />

Air Supply<br />

Combustion<br />

G<br />

4'<br />

D<br />

Vent Hood<br />

3'<br />

B C<br />

1' min.<br />

above grade<br />

G<br />

Walkway<br />

Vent termination for side wall installations:<br />

must be not less than 7 ft. above public walkways.<br />

must be at least 3 ft. above any outside air intake located within a 10 ft. radius.<br />

must NOT be within 3 ft. of an inside corner of the structure.<br />

must be at least 1 ft. above grade.<br />

Recommended sources for<br />

side wall Vent Hood; see page 17,<br />

Section Venting.<br />

must be located the following distances away from any door, window, or gravity air inlet:<br />

D 4 ft. below<br />

E 4 ft. horizontally<br />

F 1 ft. above<br />

Air Supply<br />

See Air Supply Requirements Table.<br />

Figure 13.<br />

(Table 10. on page 15.)<br />

P/N <strong>NT</strong>SM03 Rev. B 2-11-04