Troubleshooting<br />

1. Check for 24 VAC at FS terminal on<br />

Ignition Module If none, Ignition Module<br />

is bad.<br />

POWER / T-STAT / AUX / PRESS<br />

HEAT (on then off) / SERVICE (off then on)<br />

Fan Running / HSI Energized / Burners ignite and<br />

the go off in 7 seconds or less<br />

2. Check for 24 VAC at Connector on Flame<br />

Sensor, if none, replace wire.<br />

3. Check to make sure the Flame Sensor is<br />

not shorted to Ground.<br />

4. If Flame Sensor voltage and amperage are<br />

OK, Ignition Module is bad.<br />

P/N <strong>NT</strong>SM03 Rev. B 2-11-04