38<br />
Troubleshooting<br />
1. Check for 24 VAC at FS terminal on<br />
Ignition Module If none, Ignition Module<br />
is bad.<br />
POWER / T-STAT / AUX / PRESS<br />
HEAT (on then off) / SERVICE (off then on)<br />
Fan Running / HSI Energized / Burners ignite and<br />
the go off in 7 seconds or less<br />
2. Check for 24 VAC at Connector on Flame<br />
Sensor, if none, replace wire.<br />
3. Check to make sure the Flame Sensor is<br />
not shorted to Ground.<br />
4. If Flame Sensor voltage and amperage are<br />
OK, Ignition Module is bad.<br />
P/N <strong>NT</strong>SM03 Rev. B 2-11-04