„Filius- <strong>ACS</strong> <strong>Multi</strong> <strong>IQ</strong>“ operating instructions<br />
7.4 Preparing settings<br />
7.4.1.1.1.1 Mainsvoltagecalibration(see°6.5.3.2.9.1°Resetregulator<br />
The current controller converts from current to Skt. For that the control executes a learning welding<br />
operation. The first welding operation after a controller reset is a learning welding operation.<br />
When should a learning welding operation be done?<br />
A new learning welding operation has to be done absolutely when changing the power unit. In case<br />
of nonsatisfying weldings by reason of changed marginal conditions a new learning welding<br />
operation may lead to better results.<br />
<br />
<br />
<br />
Alignment of mains voltage compensation)<br />
Review and calibration of the ignition point if necessary<br />
(see°6.5.3.2.9.6°Alignment of ignition point)<br />
Adjustment of the cos (see 6.5.3.2.5 Welding parameters)<br />
7.5 Initial welding operation<br />
7.5.1 Neededsignals<br />
For the welding process at least the following input signals are needed:<br />
<br />
<br />
<br />
<br />
<br />
Emergency stop<br />
Transformer temperature<br />
Program selection if external program selection (6.5.3.2.5 Welding parameters) is set.<br />
Pressure contact<br />
Start<br />