„Filius- <strong>ACS</strong> <strong>Multi</strong> <strong>IQ</strong>“ operating instructions<br />

7.4 Preparing settings<br />

7.4.1.1.1.1 Mainsvoltagecalibration(see°6.5.3.2.9.1°Resetregulator<br />

The current controller converts from current to Skt. For that the control executes a learning welding<br />

operation. The first welding operation after a controller reset is a learning welding operation.<br />

When should a learning welding operation be done?<br />

A new learning welding operation has to be done absolutely when changing the power unit. In case<br />

of nonsatisfying weldings by reason of changed marginal conditions a new learning welding<br />

operation may lead to better results.<br />

<br />

<br />

<br />

Alignment of mains voltage compensation)<br />

Review and calibration of the ignition point if necessary<br />

(see°6.5.3.2.9.6°Alignment of ignition point)<br />

Adjustment of the cos (see 6.5.3.2.5 Welding parameters)<br />

7.5 Initial welding operation<br />

7.5.1 Neededsignals<br />

For the welding process at least the following input signals are needed:<br />

<br />

<br />

<br />

<br />

<br />

Emergency stop<br />

Transformer temperature<br />

Program selection if external program selection (6.5.3.2.5 Welding parameters) is set.<br />

Pressure contact<br />

Start<br />