„Filius- <strong>ACS</strong> <strong>Multi</strong> <strong>IQ</strong>“ operating instructions<br />
9 Connectiondiagrams<br />
The welding control "Filius" features a lot of functionalities. So connecting the welding<br />
control "Filius" is illustrated in several connection diagrams.<br />
The supply of the "Filius" welding control including any inputs and outputs is done by the<br />
thyristor power unit, if it is attached with a thyristor power unit of the "Filius" power unit<br />
family.<br />
If other power units are used the control as well as inputs and outputs must be supplied<br />
with 24 VDC by an additional power supply unit.<br />
The "Filius" signal inputs can be connected to contacts or PLC outputs. The contact inputs<br />
are supplied over plug 1 of the connectors X7, X8.<br />
When using PLC outputs the 0 V level of the PLC supply must be connected with pin<br />
X7/12 and X8/10.<br />
<br />
Caution; external voltage must not be connected<br />
to the pins X7/1 or X8/1!<br />
44