Service manual<br />

GEAR REDUCER PROTECTION – RM4JA32<br />

- Gear reducer of the rotating shaft<br />

Electrical supply: 400/50/3<br />

!<br />

the measuring relay (over current protection) is supplied with<br />

the machine, to protect the gear reducer and shaft.<br />

The control relay (control RM4JA32) measures the current on the power supply to<br />

the motor and controls its operation (see electrical circuit diagram).<br />

1<br />

2<br />

3<br />

4<br />

Dim. 45x78 mm<br />

In order to avoid an excessive formation of ice<br />

before the restart, the measuring relay has to close down the water inlet and<br />

refrigerant inlet.<br />

The current relay (gear-motor protection), has to be installed as follows:<br />

A1-A2 electrical supply 24~240V<br />

C+B1 supply phase drive-motor (EVE201-301-401-651-801)<br />

C+B2 supply phase drive-motor (EVE1001-1301-1501-2401)<br />

15 +18 supply relay with manual restart for plant control<br />

SET UP:<br />

1) Current absorbed in normal working conditions increased by 5%;<br />

2) Hysteresis = calibration 15%<br />

3) Timer = calibration 50%<br />

4) Motor function/delay = calibration to >1 sec<br />

26<br />