Service Manual<br />

d) ICE WHICH IS DIFFICULT TO BREAK:<br />

Check the distance between the scraping roller and scraping blade and adjust as<br />

required, if the problem persists add some salt to the water, see start-up and<br />

adjustment.<br />

e) LIQUID RETURN TO THE COMPRESSOR:<br />

The evaporator is being overfed; it is necessary to adjust the regulation tap (FTL) or<br />

the thermostatic valve.<br />

This could also occur when the machine has not been shut-down according to the<br />

correct procedure.<br />