Some examples of replicated microstructures, documented with both a<br />

scanning electron microscope and with conventional optical microscopy, are<br />

shown in Figs. 58 to 61. Replication is used for detection of high temperature<br />

creep damage, stress corrosion cracking, hydrogen cracking mechanisms,<br />

as well as the precipitation of carbides, nitrides and second phase<br />

precipitates such as sigma or gamma prime. Replication is also used for<br />

distinguishing fabrication discontinuities from operational discontinuities.<br />