10<br />

4. Fuel System<br />

The <strong>D7W</strong>B is most commonly provided with the<br />

fuel metering pump mounted inside the box.This<br />

is to reduce installation time and to protect the<br />

pump from corrosion. If specifications cannot be<br />

met the pump must be mounted externally. Refer<br />

to Figure IIC for connections and specifications.<br />

All parts necessary to do the installation are<br />

included in the kit as shown in Figure IIC.<br />

N o t e : Fuel line limits must not be ex c e e d e d .<br />

Ensure that the fo l l owing conditions are<br />

m e t .<br />

Bottom of the fuel metering pump must be<br />

within a height of 2’6” of the bottom of the<br />

fuel pick-up pipe.<br />

Fuel metering pump must be within a total<br />

distance of 6’6” from the fuel pick-up pipe.<br />

Fuel System Tolerances<br />

Figure IIC<br />

Note: Butt joints and clamps on<br />

all connections.<br />

1. Fuel Pick-Up Pipe 5. 9mm Clamp<br />

2. 11mm Clamp 6. 3.5mm Rubber Connector<br />

3. 5.0mm Fuel Line 7. 2.0mm White Plastic Fuel Line<br />

4. Fuel Metering Pump