4. Fuel System<br />
The <strong>D7W</strong>B is most commonly provided with the<br />
fuel metering pump mounted inside the box.This<br />
is to reduce installation time and to protect the<br />
pump from corrosion. If specifications cannot be<br />
met the pump must be mounted externally. Refer<br />
to Figure IIC for connections and specifications.<br />
All parts necessary to do the installation are<br />
included in the kit as shown in Figure IIC.<br />
N o t e : Fuel line limits must not be ex c e e d e d .<br />
Ensure that the fo l l owing conditions are<br />
m e t .<br />
Bottom of the fuel metering pump must be<br />
within a height of 2’6” of the bottom of the<br />
fuel pick-up pipe.<br />
Fuel metering pump must be within a total<br />
distance of 6’6” from the fuel pick-up pipe.<br />
Fuel System Tolerances<br />
Figure IIC<br />
Note: Butt joints and clamps on<br />
all connections.<br />
1. Fuel Pick-Up Pipe 5. 9mm Clamp<br />
2. 11mm Clamp 6. 3.5mm Rubber Connector<br />
3. 5.0mm Fuel Line 7. 2.0mm White Plastic Fuel Line<br />
4. Fuel Metering Pump