28 <strong>ST60</strong> <strong>Tridata</strong> <strong>Instrument</strong> Owner’s Manual<br />
• Lock the shallow alarm.<br />
• Set the required units for speed readings.<br />
• Set the speed resolution.<br />
• Select the log distance units<br />
• Either calibrate the speed reading to Speed Over Ground (SOG) or<br />
manually apply a calibration factor, to obtain correct speed through<br />
the water.<br />
• Select temperature units.<br />
• Calibrate for correct temperature readings.<br />
• Set timer alarm buzzer on or off.<br />
Separate routines are provided for the User calibration of the depth and<br />
speed functions. To carry out either of these routines:<br />
1. Power up the <strong>ST60</strong> <strong>Tridata</strong> instrument.<br />
To start User calibration<br />
hold down<br />
depth and speed<br />
for approximately 2 seconds<br />
User calibration<br />
entry screen<br />
press either<br />
depth<br />
see User calibration - depth illustration<br />
or<br />
speed<br />
see User calibration - speed illustration<br />
Starting User calibration D4416-1<br />
2. Press the depth and speed keys for approximately 2 seconds so that<br />
the User calibration entry screen is displayed.<br />
3. Carry out the User calibration procedures for Depth and Speed.