Horizon Seafari Model 450-1800 Owner's Manual - Zanshin
Horizon Seafari Model 450-1800 Owner's Manual - Zanshin
Horizon Seafari Model 450-1800 Owner's Manual - Zanshin
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
HROSystems <strong>Horizon</strong> <strong>Seafari</strong> Specifications<br />
HIGH PRESSURE PUMP ELECTRICAL MOTOR SPECIFICATIONS WITH SOFT<br />
MOTOR STARTER (SINGLE PHASE ONLY):<br />
(H.P. = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes @ Start Up)<br />
<strong>450</strong>-1 & 900-2 SYSTEMS<br />
50 Hz H.P. 60 Hz H.P.<br />
PHASE VAC 50 Hz FLA LRA VAC 60 Hz FLA LRA<br />
Single 110 2.2 21 54.5 115 2.2 18 42.3<br />
Single 220 2.2 10.5 27.2 230 2.2 9 21.2<br />
700-1 & 1400-2, and 900-1 & <strong>1800</strong>-2 SYSTEMS<br />
50 Hz H.P. 60 Hz H.P.<br />
PHASE VAC 50 Hz FLA LRA VAC 60 Hz FLA LRA<br />
Single 110 2.2 21 54.5 115 2.6 21.2 49.1<br />
Single 220 2.2 10.5 27.2 230 2.6 10.6 24.5<br />
BOOSTER PUMP MOTOR:<br />
1/2 horse power<br />
PHASE Hz VAC H.P. FLA LRA<br />
Single 50/60 115 .5 7.4 34<br />
Single 50/60 220/230 .5 3.7 17<br />
Three 50/60 220/230 .5 2 12<br />
Three 50/60 380/460 .5 1 6<br />
RECOMMENDED CIRCUIT BREAKER:<br />
Operating Voltage Hz & Phase<br />
Recommended Circuit Breaker Size<br />
115 VAC Single Phase 35 Amperes<br />
230 VAC Single Phase 15 Amperes<br />
Soft Motor starters are available for single phase only. The Soft Start lowers the starting<br />
torque of the high-pressure pump motor only. This reduces the locked rotor amps required to<br />
start the system. These reduced locked rotor amp values are shown in the above High<br />
Pressure Pump Motor Specifications with Soft Motor Starter.<br />
Page B - 5