HROSystems <strong>Horizon</strong> <strong>Seafari</strong> Specifications<br />

HIGH PRESSURE PUMP ELECTRICAL MOTOR SPECIFICATIONS WITH SOFT<br />

MOTOR STARTER (SINGLE PHASE ONLY):<br />

(H.P. = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes @ Start Up)<br />

<strong>450</strong>-1 & 900-2 SYSTEMS<br />

50 Hz H.P. 60 Hz H.P.<br />

PHASE VAC 50 Hz FLA LRA VAC 60 Hz FLA LRA<br />

Single 110 2.2 21 54.5 115 2.2 18 42.3<br />

Single 220 2.2 10.5 27.2 230 2.2 9 21.2<br />

700-1 & 1400-2, and 900-1 & <strong>1800</strong>-2 SYSTEMS<br />

50 Hz H.P. 60 Hz H.P.<br />

PHASE VAC 50 Hz FLA LRA VAC 60 Hz FLA LRA<br />

Single 110 2.2 21 54.5 115 2.6 21.2 49.1<br />

Single 220 2.2 10.5 27.2 230 2.6 10.6 24.5<br />

BOOSTER PUMP MOTOR:<br />

1/2 horse power<br />

PHASE Hz VAC H.P. FLA LRA<br />

Single 50/60 115 .5 7.4 34<br />

Single 50/60 220/230 .5 3.7 17<br />

Three 50/60 220/230 .5 2 12<br />

Three 50/60 380/460 .5 1 6<br />

RECOMMENDED CIRCUIT BREAKER:<br />

Operating Voltage Hz & Phase<br />

Recommended Circuit Breaker Size<br />

115 VAC Single Phase 35 Amperes<br />

230 VAC Single Phase 15 Amperes<br />

Soft Motor starters are available for single phase only. The Soft Start lowers the starting<br />

torque of the high-pressure pump motor only. This reduces the locked rotor amps required to<br />

start the system. These reduced locked rotor amp values are shown in the above High<br />

Pressure Pump Motor Specifications with Soft Motor Starter.<br />