OPERATION<br />
1<br />
2<br />
BM5-041M<br />
Starting up the 230 V<br />
alternator system*<br />
The 230 V alternator system* is switched<br />
on by pressing the green button* with the<br />
engine running.<br />
To be switched on the alternator requires a<br />
speed of 2,700 rpm, which corresponds to<br />
an engine speed of 850 rpm.<br />
The maximum current draw of 16 A 1)<br />
(equivalent to 3.5 kVA) is possible at an engine<br />
speed of 1,700 rpm. At engine idling<br />
speed approx. 4 A 1) (equivalent to 0.9 kVA)<br />
is available.<br />
The green indicator lamp 1 in the switch*<br />
lights up when the system is ready for<br />
operation.<br />
1) Amperes<br />
During operation<br />
After the 230 V alternator system* is<br />
switched on you can connect your 230 V<br />
devices.<br />
Should the power draw be too high for the<br />
current engine speed, then the red indicator<br />
lamp in the On/Off switch* lights up and the<br />
system is switched off.<br />
In this operating state you can now either<br />
increase the engine speed to remove more<br />
power, or you must switch off a few consumers<br />
to limit the power draw. Then the<br />
230 V alternator system must be restarted.<br />
Should no power be available during operation<br />
and the red indicator lamp 2 in the On/<br />
Off switch* lights up, then there is a fault in<br />
the 230 V power system or in the 230 V<br />
alternator system*.<br />
In this case, see the chapter Self-Help from<br />
page 30.<br />