<strong>UFC</strong> 2-000-05N<br />

31 JAN 2005<br />

Table 74040-7 POOL/BILLIARDS DEMAND CALCULATION<br />

Note # Dem<strong>and</strong> Units x Usage Factor = Peak Dem<strong>and</strong><br />

(1) ____ Bowling Lanes x 0.22 machines per lane = ____ tables<br />

(2)<br />

____ Non-Bowling Patrons<br />

per Peak Hour<br />

x<br />

0.20 table-hours per<br />

patron<br />

= + ____ tables<br />

Total Dem<strong>and</strong> (round to the nearest whole unit) = ____ tables<br />

74040-6 SPACE ALLOWANCES. Space allowances for Bowling Centers are<br />

determined according to the planning criteria presented in Table 74040-8 below. The<br />

total allowance for a facility is the sum total of the space allowances for each functional<br />

component. The number of units of each component required to meet the dem<strong>and</strong> is<br />

obtained from the calculations in Tables 74040-1 through 74040-7.<br />

Table 74040-8 SPACE ALLOWANCES FOR BOWLING CENTERS<br />

Note Table Functional Component<br />

A, B<br />

ACTIVITY AREAS<br />

Bowling<br />

Bowling Lanes (incl. pin<br />

spotting, settee, promenade,<br />

lockers)<br />

#<br />

Units<br />

x<br />

Space<br />

Allocation<br />

Factor<br />

=<br />

Total<br />

NSF<br />

___ x 650 NSF per lane = ___<br />

A, B Workroom ___ x 70 NSF per lane = +___<br />

Food Service<br />

C<br />

Snack Bar (incl. seating,<br />

kitchen, serving counter, ___ x 27 NSF per lane = +___<br />

storage)<br />

D<br />

Lounge (incl. seating, bar,<br />

storage)<br />

___ x 20 NSF per lane = +___<br />

(1) E<br />

Combined Snack Bar/Lounge<br />

(incl. seating, kitchen, serving ___ x 25 NSF per lane = +___<br />

counter, bar, storage)<br />

(2) Meeting/Function Room ___ x 12 NSF per lane = +___<br />

Games<br />

Video Games ___ x 30 NSF per lane = +___<br />

Pool/Billiards ___ x 370 NSF per lane = +___<br />

Subtotal Activity Areas = +___<br />

ACTIVITY SUPPORT AREAS<br />

Toilets 3% x Subtotal Activity Areas = +___<br />

Administration (incl. pro shop,<br />

control counter, storage)<br />

3% x Subtotal Activity Areas = +___<br />

Subtotal Activity Support Areas = +___<br />

BUILDING SUPPORT<br />

AREAS<br />

Minimum or<br />

Maximum<br />

NSF<br />

120 NSF min.<br />

840 NSF max.<br />

1,000 NSF<br />

max.<br />

700 SERIES - 34