GSM and EDGE Analyzer<br />

GSM and EDGE Analyzer<br />

Optional GSM and EDGE Tx Analyzer <strong>Measurement</strong> Settings<br />

results. If your measured TS Power is outside your specified limits, the numeric<br />

results reported in the metrics portion of the screen will be displayed in red, and the<br />

Limit Failure will be indicated by “(F)” after the results.<br />

To Set the TS Power Limits:<br />

Step<br />

Notes<br />

1 [Setup]<br />

2 [TS Pwr Limits]<br />

3 [Limits]<br />

4 [On] or [Off]<br />

5 Set the upper limit.<br />

a. [High Limit]<br />

b. Enter the number on<br />

the numeric keypad.<br />

c. [dBm]<br />

6 Set the lower limit.<br />

a. [Low Limit]<br />

b. Enter the number on<br />

the numeric keypad.<br />

c. [dBm]<br />

Setting the I/Q Offset Limit<br />

You can set an upper I/Q Offset Limit for your <strong>Measurement</strong> results.<br />

If I/Q Offset Limit is turned On, and your measured I/Q Offset is below the limit<br />

you have specified, the numeric results reported in the metrics portion of the screen<br />

will be displayed in green, and the Limit Pass will be indicated by “(P)” after the<br />

result. If your measured I/Q Offset is above your specified limit, the numeric result<br />

reported in the metrics portion of the screen will be displayed in red, and the Limit<br />

Failure will be indicated by “(F)” after the results.<br />