TECHNICAL IN<strong>FOR</strong>MATION Page 19<br />
w w w. d r o o f f - k a m i n o f e n . d e<br />
Performance parameters Logs/ Wood briquette Lignite briquettes<br />
Rated thermal output in kW 4.0 8.0 8.0<br />
Thermal output range in kW 3 - 10 3 - 10<br />
Exhaust gas mass flow in g/s 3.6 6.2 7.0<br />
Temp. at chimney sleeve in °C 300 330 345<br />
Suction pressure in mbar 0.12 min. 0.12 min. 0.12 min.<br />
0.20 max. 0.20 max. 0.20 max.<br />
CO emission in mg/Nm 3 1250.0 1250.0 2000.0<br />
Dust emission in mg/Nm 3 < 40.0 < 40.0<br />
Efficiency in % 82.5 82.9 78.9<br />
(All data is laboratory data)<br />
DISTANCE TO COMBUSTIBLE MATERIALS<br />
Safety clearance to inflammable materials/partition walls<br />
Rear 15 cm<br />
Position near wall<br />
Back wall<br />
15 cm<br />
Side 20 cm<br />
Front 85 cm 20 cm<br />
Side wall<br />
For your own safety it is essential to observe the above distances between the stove and<br />
combustible or valuable objects e.g. furniture, panelling, wood etc. as well as structural walls<br />
of steel reinforced concrete. The distance between the stove and non-combustible materials<br />
or objects may be slightly less. These clearances are required for compliance with the<br />
regulations applicable in Germany for fireplaces, stoves and other heating appliances.<br />
In spite of compliance with the above safety clearances, the stove may cause discolouration<br />
of sensitive materials in its vicinity e.g. wallpapers containing vinyl, textile or other structuring<br />
substances. These discolourations are due to the quality of the materials and are not covered<br />
by the guarantee. The specified safety clearances between the stove and inflammable or<br />
valuable objects are intended only to prevent the outbreak of fire.<br />
Side wall<br />
85 cm<br />
Corner position<br />
Back wall<br />
15 cm<br />
15 cm<br />
20 cm<br />
20 cm<br />
85 cm<br />
DROOFF Kaminöfen — Feuer aus dem Sauerland