4 <strong>VRIOGS</strong> <strong>012.2.1</strong> REVISION A<br />

SECTION 3.0 SCOPE AND GENERAL<br />

3.1 Scope<br />

This Standard mandates the accepted criteria that shall be employed when installing new,<br />

or making alterations on the <strong>Victoria</strong>n Rail Network. For existing installations, the standard<br />

only applies to the altered part(s). The standard is not intended to be retrospectively<br />

applied to existing installations (but when a change is introduced, that change is required<br />

to comply with this standard).<br />

The purpose of this Standard is to provide the requirements for the Construction of the<br />

Signal and Communications cable route and Signalling civil type works.<br />

This Standard describes the minimum requirements for the following works:<br />

a) Construction of various types of cable routes<br />

b) Construction of under line and under road crossings.<br />

c) Construction of cable pits, jointing pits and cable turning chambers.<br />

d) Construction of foundations for signals and signal gantries<br />

e) Construction of foundations for Equipment Boxes<br />

f) Construction of access paths and associated works<br />

g) Construction of retaining walls, ladders and safety handrails<br />

h) Construction of fencing and gates for signalling works<br />

3.2 Application<br />

This standard applies to all of the <strong>Victoria</strong>n Rail Network encompassed by the State<br />

borders and shall be applied for the construction of cable routes and signalling civil works,<br />

as well as Telecommunications works in shared infrastructure such as trenches, ground<br />

level troughing, trunking and similar.<br />

This Standard shall be used in conjunction with <strong>VRIOGS</strong> 012.2 Signalling Supply,<br />

Construction and Installation.<br />

For Telecommunications Design and Construction works this specification shall be used in<br />

conjunction with VicTrack Communications Installation Specification TS-SP013 (latest<br />

version) and <strong>VRIOGS</strong> Telecommunications Standards and Specifications.<br />

3.3 Background<br />

The following standards have been superseded by this standard with relation to the<br />

construction of cable routes and signalling civil works.<br />

List of documents superseded or utilised for the signalling and communications cable<br />

route and signalling civil type works areas;<br />

a) <strong>VRIOGS</strong> 012.2 Specification for Signalling Supply, Construction and Installation,<br />

and only sections where defining the construction of cable routes and signalling civil<br />

works.<br />

NOTE: This document is controlled only when viewed on the DOT Engineering Standards website.<br />