20 <strong>VRIOGS</strong> <strong>012.2.1</strong> REVISION A<br />

d) The buried conduits shall be extended past the edge of the creek banks a minimum<br />

of 4 metres on either side of the creek or waterway. The minimum depth of the<br />

whole of this conduit run shall be 800 mm.<br />

6.18 Cable Routes on Embankments<br />

a) The proposed methods for installing cable routes up or down embankments shall be<br />

submitted for approval to the Infrastructure Manager, and shall be compliant with<br />

this Standard.<br />

b) The methods proposed shall be such that there will be no destabilising of the<br />

embankment and no erosion in the vicinity of the route.<br />

6.19 Cable Routes on Bridges and Viaducts<br />

a) The proposed methods for installing cable routes on bridges shall be submitted for<br />

approval to the Infrastructure Manager.<br />

b) The methods proposed shall be such that there will adequate capacity for future<br />

cabling requirements, and all provisions of this Standard shall be complied with;<br />

separation and segregation of the various services, access and egress for<br />

maintenance purposes, installation methods.<br />

c) Suggested appropriate cable route types being; Type 4 conduits and pits, Type 5<br />

ground level troughing (GLT), Type 6 Galvanised steel Troughing (GST).<br />