44 <strong>VRIOGS</strong> <strong>012.2.1</strong> REVISION A<br />

15.5 Station Buildings, Platform Signals and Indicators<br />

a) Cabling to platform signals and indicators shall be run in pipes buried in the<br />

platforms or in conduits or cable ducts in or on station buildings or other structures<br />

subject to specific approval. Exposed conduits or cable ducts shall be made as<br />

unobtrusive as possible and painted to blend with the supporting structure. (Note:<br />

On some stations, which are heritage listed, posts that more closely match the<br />

period architecture of the station may be required.<br />

15.6 Boom Barriers and Level Crossing<br />

a) The signalling and civil works shall be carried out as per current <strong>VRIOGS</strong> standard<br />

plans and agreed site layout plans.<br />

15.7 Pedestrian Gates<br />

a) The signalling and civil works shall be carried out as per current <strong>VRIOGS</strong> standard<br />

plans and agreed site layout plans<br />

15.8 Train Stabling Gates<br />

a) The signalling and civil works shall be carried out as per current <strong>VRIOGS</strong> standard<br />

plans and agreed site layout plans<br />

15.9 Signal Post Mounted Telephones (SPT)<br />

a) Signal Post Telephone’s are installed at identified signals and signal gantries; for<br />

train driver’s use in case of emergency or during delays or interruptions to railway<br />

traffic.<br />

b) A suitably drained, graded and level surface shall be provided for persons using the<br />

telephone. Where the telephone is immediately adjacent to the danger zone, a<br />

galvanised steel conduit railing shall be provided between the telephone and the<br />

danger zone.<br />

c) The Constructor is to provide pedestrian access to the SPT, to enable train crew to<br />

alight from the cab of a train stopped within 20 metres of the post phone and walk<br />

safely to/from and use the SPT.<br />