Boiler Design & Clearances<br />
Description<br />
The <strong>Ultrapower</strong> <strong>sxi</strong> is a high efficiency central heating appliance,<br />
close <strong>co</strong>upled to an un-vented cylinder. The pump, expansion<br />
vessels and associated safety devices are all fitted within the<br />
appliance, providing a one box solution for properties requiring<br />
a high domestic hot water demand. The intelligent <strong>co</strong>ntrol<br />
system is designed for both simple operation and maximum<br />
<strong>co</strong>ntrol. Once the <strong>co</strong>ntrols are set the boiler will operate<br />
automatically.<br />
Additionally an immersion heater is supplied fitted to the<br />
cylinder. It is intended for use as a back up should the boiler<br />
fail, it will not give optimum DHW performance.<br />
13241<br />
Pluming from flue terminal<br />
Like all <strong>co</strong>ndensing boilers it will produce a plume of<br />
<strong>co</strong>ndensation from the flue terminal in <strong>co</strong>ol weather. This is<br />
due to the high efficiency and hence low flue gas temperature<br />
of the boiler. It is normal and not a fault indication.<br />
Compartment or Cupboard Installations<br />
Ventilation is not required for <strong>co</strong>mpartment or cupboard<br />
installations. Do not use the <strong>co</strong>mpartment or cupboard for<br />
storage.<br />
Diagram 1<br />
6<br />
www.glow-worm.<strong>co</strong>.<strong>uk</strong>