f) settings functions<br />
These functions let you access to system functions of the controller, as setting the date-time, setting global<br />
variables, get the program version.<br />
• SETSHIFTINCVAR<br />
setting settting a shift increment to the current file<br />
Syntaxe :<br />
SETSHIFTINCVAR < Increment name > < Value >[CR][LF]<br />
Answer :<br />
SETSHIFTINCVAR OK[CR][LF]<br />
SETSHIFTINCVAR VAR NOT FOUND [CR][LF]<br />
OK<br />
not found<br />
Data :<br />
Increment name<br />
Shift<br />
Value<br />
in upper case<br />
shift number<br />
caution, the value is the decimal value of the increment.<br />
Example : setting the value12 for the first shift to the increment named NB_PART<br />
String to send :<br />
SETSHIFTINCVAR NB_PART 1 12[LF]<br />
String received:<br />
SETSHIFTINCVAR OK[CR][LF]<br />
• SETGLOBALVAR<br />
Affectation variable globale<br />
Syntaxe :<br />
SETGLOBALVAR [CR][LF]<br />
Answer :<br />
SETGLOBALVAR OK[CR][LF]<br />
OK<br />
Data :<br />
Number number of the global var ( from 1 to 10)<br />
Value Value to set<br />
Example : setting the first global variable to FACTORY<br />
Envoie de :<br />
SETGLOBALVAR 1 FACTORY_ONE[LF]<br />
String received:<br />
SETGLOBALVAR OK[CR][LF]<br />