11.11.2014 Views

EM3800SX•EM5000SX•EM6500SX - Geotech Environmental ...

EM3800SX•EM5000SX•EM6500SX - Geotech Environmental ...

EM3800SX•EM5000SX•EM6500SX - Geotech Environmental ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DC Operation<br />

The DC terminals may ONLY be used for charging 12-volt automotive<br />

type batteries.<br />

Connecting the battery charging cables:<br />

1. Before connecting the battery charging cables to a battery that is<br />

installed in a vehicle, disconnect the vehicle ground battery cable<br />

from the battery negative ( ) terminal.<br />

The battery gives off explosive gases; keep sparks, flames, and<br />

cigarettes away. Provide adequate ventilation when charging or<br />

using batteries.<br />

WARNING: Battery posts, terminals, and related accessories contain<br />

lead and lead components. Wash hands after handling.<br />

2. Connect the positive ( ) battery cable to the battery positive ( )<br />

terminal.<br />

3. Connect the other end of the positive ( ) battery cable to the<br />

generator positive ( ) terminal.<br />

DC CIRCUIT<br />

PROTECTOR<br />

NEGATIVE TERMINAL<br />

(BLACK)<br />

POSITIVE TERMINAL<br />

(RED)<br />

4. Connect the negative ( ) battery cable to the battery negative ( )<br />

terminal.<br />

5. Connect the other end of the negative ( ) battery cable to the<br />

generator negative ( ) terminal.<br />

6. Start the generator.<br />

Do not start the vehicle while the battery charging cable is connected<br />

and the generator is running. The vehicle or the generator may be<br />

damaged.<br />

26

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!