APPENDIX D: DIAGRAM OF JOINT IN<br />

TEST FIXTURE<br />

Loading Fixture with Torsional Loadcase LVDT Placement<br />

152.4 mm<br />

C L<br />

152.4mm<br />

LVDT 1 LVDT 2<br />

LVDT 3<br />

<strong>Report</strong>: A/SP-005-1 <strong>Light</strong> <strong>Truck</strong> <strong>Frame</strong> <strong>Joint</strong> <strong>Study</strong> 120