5. Accessories<br />
Internal Accessories<br />
Left-side<br />
mounting<br />
Handle AL AX SHT or UVT TI Cassette-type accessories<br />
Right-side<br />
mounting MG EAL TBL PAL TBM Lead wire direction<br />
Type<br />
NF-C/S/H<br />
NF400-CW/SW<br />
NF400-SEW/HEW/REW<br />
NF630-CW/SW<br />
NF630-SEW/HEW/REW<br />
NF800-CEW/SDW<br />
NF800-SEW/HEW/REW<br />
NF1000-SEW<br />
NF1250-SEW<br />
NF1600-SEW<br />
NF1250-SDW<br />
NF1600-SDW<br />
NF-U<br />
NF400-UEW (3P)<br />
NF400-UEW (4P), NF800-UEW<br />
—<br />
Poles<br />
2, 3, 4<br />
Switch<br />
type<br />
S V<br />
✳3<br />
AL<br />
✳3<br />
AX<br />
1 3<br />
2 4<br />
1 5 3<br />
2 6 4<br />
1<br />
2<br />
5<br />
3<br />
4<br />
6<br />
SHT<br />
or<br />
UVT<br />
✳1<br />
✳2<br />
✳1<br />
✳2<br />
✳2<br />
✳3<br />
✳3<br />
AL + AX<br />
Accessories<br />
AL + SHT or UVT<br />
✳1<br />
✳2<br />
✳3<br />
✳4<br />
✳1<br />
✳2<br />
✳3<br />
✳4<br />
✳2<br />
AX + SHT or UVT<br />
3<br />
1<br />
2<br />
✳1<br />
✳2<br />
✳3<br />
✳4<br />
1 3<br />
2 4<br />
3<br />
4<br />
5<br />
1<br />
2<br />
✳1<br />
✳2<br />
✳3<br />
✳4<br />
✳2<br />
AL + AX + SHT or UVT<br />
✳1<br />
✳2<br />
✳3<br />
✳4<br />
✳1<br />
✳2<br />
✳3<br />
✳4<br />
✳2<br />
✳5<br />
✳5<br />
✳5<br />
PAL<br />
(contact output)<br />
Option for<br />
NF400-SEW/HEW/REW/UEW (3P)<br />
NF630-SEW/HEW/REW<br />
✳6<br />
Option for NF400-UEW(4P)<br />
NF800-CEW/SEW/HEW/REW/UEW<br />
✳6<br />
Option for NF1000-SEW<br />
NF1250-SEW<br />
NF1600-SEW<br />
TI<br />
Option for NF400-SEW/HEW/REW/UEW (3P)<br />
NF630-SEW/HEW/REW<br />
Option for NF400-UEW(4P)<br />
NF800-CEW/SEW/HEW/REW/UEW<br />
45<br />
The number within the circle shows the order of mounting.<br />
✳ 1.<br />
SHT and UVT are right-pole mounting as standard. Please specify if left-pole mounting is required.<br />
✳ 2. UVT mounting requires a UVT voltage module (SHT requires no such voltage module) .<br />
✳ 3. When mounting more than three left-pole mounting devices by SLT, or when mounting a SHT or UVT to the same pole as the AL, AX or AL + AX, a special-order SLT is necessary .<br />
✳ 4. When mounting a UVT to the same pole as the AL, AX, or AL + AX, the UVT voltage module is separate .<br />
✳ 5. SLT-equipped is standard. Control voltage (AC100~200V) is necessary. (In this case, no other accessories can be mounted to the breaker's right pole. )<br />
✳ 6. SLT-equipped is standard. Control voltage (AC100~200V/DC100~200V) is necessary. (In this case, no other accessories can be mounted to the breaker's right pole. )