16.11.2014 Views

MOLDED-CASE CIRCUIT BREAKERS & EARTH ... - Piti Group

MOLDED-CASE CIRCUIT BREAKERS & EARTH ... - Piti Group

MOLDED-CASE CIRCUIT BREAKERS & EARTH ... - Piti Group

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MOLDED</strong>-<strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKERS</strong> &<br />

<strong>EARTH</strong>-LEAKAGE <strong>CIRCUIT</strong> <strong>BREAKERS</strong><br />

World Super<br />

Series<br />

<br />

Mitsubishi Electric Corporation's Fukuyama Works,<br />

which produces these products, is certified as meeting<br />

the ISO 14001:2004 environmental management system standard.<br />

07<br />

A


INDEX<br />

This material has been prepared for those who use the products for<br />

manufacturing assemblies, for holding electric works, for holding<br />

maintenance and for the others acquainted with electric expertise<br />

including those who operate the products (final users).<br />

Introduction ........................................................................................................................................ 1<br />

Features .............................................................................................................................................. 3<br />

The Great Variable Accessories for Perfect Solution ...................................................................... 9<br />

1. Series Configuration and List of Product Models ...................................................................... 11<br />

2. Detailed Specifications ................................................................................................................. 13<br />

Molded-Case Circuit Breakers ........................................................................................................................................ 13<br />

Earth-Leakage Circuit Breakers ...................................................................................................................................... 21<br />

Motor-Protection Breakers .............................................................................................................................................. 25<br />

UL Listed Products .......................................................................................................................................................... 26<br />

Miniature Circuit Breakers ............................................................................................................................................... 27<br />

ELRs and ZCTs ................................................................................................................................................................. 31<br />

Circuit Protectors ............................................................................................................................................................. 33<br />

3. Special Purpose Breakers ............................................................................................................ 34<br />

Mag Only (Instantaneous tripping circuit breakers) ............................................................................................................ 34<br />

DC-Use MCCBs and DSN-type Switches ....................................................................................................................... 34<br />

400Hz-Use MCCBs ........................................................................................................................................................... 35<br />

Low-Instantaneous MCCBs ............................................................................................................................................. 35<br />

Generator-Protection MCCBs ......................................................................................................................................... 35<br />

Measuring Display Unit (MDU) Breakers ....................................................................................................................... 36<br />

4. Connection Method ...................................................................................................................... 42<br />

1. Connection Types<br />

2. Connection Accessories<br />

3. Connection of Line and Load<br />

......................................................................................................................................................................<br />

............................................................................................................................................................<br />

.....................................................................................................................................................<br />

42<br />

42<br />

42


Caution<br />

The manual covers the product specifications for selecting an appropriate<br />

low-voltage breaker. There is the “HANDLING AND MAINTENANCE”<br />

describing how to handle the products. To use the products, separately<br />

request the “HANDLING AND MAINTENANCE”, for correct operation.<br />

1<br />

5. Accessories ................................................................................................................................... 43<br />

Internal Accessories .........................................................................................................................................................<br />

1. Accessories ...............................................................................................................................................................................<br />

2. Switch Operation and Rating .....................................................................................................................................................<br />

3. Maximum Number of Internally Mounted Accessories ..............................................................................................................<br />

4. Shunt Trip (SHT) ........................................................................................................................................................................<br />

5. Undervoltage Trip (UVT).............................................................................................................................................................<br />

6. Test Button Module (TBM) .........................................................................................................................................................<br />

7. Lead-wire Specifications ............................................................................................................................................................<br />

8. Internal Terminal Type (INT) .......................................................................................................................................................<br />

9. Vertical Lead-wire Terminal Block (SLT) ....................................................................................................................................<br />

10. Pre-Alarm Module (PAL) ..........................................................................................................................................................<br />

11. Trip Indicator (TI) ......................................................................................................................................................................<br />

12. 3ø4W Neutral-pole protection Relay (NR) ...............................................................................................................................<br />

External Accessories .......................................................................................................................................................<br />

1. V-type Operating Handle ............................................................................................................................................................<br />

2. F-type Operating Handle ............................................................................................................................................................<br />

3. S-type Operating Handle............................................................................................................................................................<br />

4. R-type Operating Handle ...........................................................................................................................................................<br />

5. Terminal Cover ...........................................................................................................................................................................<br />

6. Electrical Operation Device ........................................................................................................................................................<br />

7. Mechanical Interlocks (MI) .........................................................................................................................................................<br />

8. Handle Lock Devices and Card Holder ......................................................................................................................................<br />

9. IEC 35mm Rail Mounting Adapters ............................................................................................................................................<br />

6. Characteristics and Dimensions..................................................................................................<br />

71<br />

Molded-Case Circuit Breakers and Motor Breakers ..................................................................................................... 71<br />

Earth-Leakage Circuit Breakers ................................................................................................................................... 107<br />

UL489 Listed Molded-Case Circuit Breakers ............................................................................................................... 131<br />

Miniature Circuit Breakers ............................................................................................................................................ 143<br />

DIN Series ....................................................................................................................................................................... 146<br />

Circuit Protectors ........................................................................................................................................................... 151<br />

7. Ordering Information................................................................................................................... 153<br />

Molded-Case Circuit Breakers ...................................................................................................................................... 153<br />

Earth-Leakage Circuit Breakers ................................................................................................................................... 153<br />

8. Melshort 2 .................................................................................................................................... 154<br />

(A more rational and easier breakers selections)<br />

9. Low-voltage switchgears Technical information service via the internet .............................. 155<br />

(http://global.MitsubishiElectric.com/lvs)<br />

43<br />

43<br />

43<br />

44<br />

49<br />

49<br />

50<br />

50<br />

50<br />

51<br />

52<br />

53<br />

53<br />

54<br />

54<br />

55<br />

57<br />

58<br />

60<br />

61<br />

69<br />

70<br />

70<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9


Full range of MITS<br />

(30A to 16<br />

High-Performance<br />

Downsizing of 630AF, New Digital ETR<br />

Previous<br />

210<br />

New<br />

140<br />

Glo<br />

Compliance with w<br />

ASTA<br />

275<br />

257<br />

Time (s)<br />

1 x 10 4 Ir<br />

Switch<br />

Current setting<br />

with fuse<br />

1 x 10 3<br />

High<br />

High-voltage fuse-<br />

voltage<br />

Allowable short-time<br />

Ip<br />

1 x 10 2<br />

TL<br />

characteristics<br />

Low<br />

Long-delay operating time<br />

voltage<br />

Transformer<br />

Pre-alarm<br />

10<br />

NFB<br />

current<br />

Short-delay<br />

(electronic)<br />

Is<br />

tripping current<br />

M<br />

1<br />

Short-delay<br />

Load<br />

Load current<br />

Ts operating time<br />

0.1<br />

Ii<br />

Instantaneous tripping current<br />

0.01<br />

Current-converted value<br />

Current (A) on the high-voltage side<br />

EN<br />

TUV<br />

GB<br />

CCC<br />

TPC<br />

JIS<br />

Volume<br />

60% downsized<br />

New Digital ETR<br />

IEC<br />

SABS<br />

Best Solution<br />

Plenty of accessories, Easy installation<br />

250AF (Type“SGW, HGW, RGW, UGW”) Product Skelton<br />

16<br />

22<br />

10<br />

11 12 13<br />

LR GL DNV ABS BV NK<br />

World Super<br />

17<br />

23<br />

7<br />

8<br />

9<br />

18<br />

24<br />

6<br />

19<br />

15<br />

14<br />

1<br />

20<br />

21<br />

1<br />

5<br />

4<br />

7<br />

8<br />

9<br />

3<br />

2<br />

Series<br />

10<br />

11<br />

12<br />

13<br />

1


UBISHI WS Series<br />

00A frame)<br />

bal<br />

orldwide standards<br />

Relay<br />

JPT<br />

Reliable<br />

High reliability, Best performance<br />

Mechanism<br />

Breaking Performance<br />

Terminal<br />

CSA<br />

UL<br />

Internal Accessories<br />

Shunt-less Advanced ISTAC PA Auto-Puffer<br />

External Accessories<br />

Intelligent<br />

Measuring and communicating<br />

Personal<br />

Computer<br />

By using various application software for PLC, users can also connect to the<br />

network SCADA system.<br />

MELSECNET/10<br />

Interface card<br />

MELSECNET/10<br />

CC-Link®<br />

PLC<br />

Interface<br />

Unit<br />

I/O Unit<br />

Eco Monitor Pro<br />

ME110S<br />

AE-SW<br />

MDU<br />

2


Global<br />

Compliance with worldwide standards<br />

World Super<br />

ASTA<br />

EN<br />

TUV<br />

GB<br />

CCC<br />

JIS<br />

CSA<br />

UL<br />

Series<br />

TPC<br />

IEC<br />

SABS<br />

LR GL DNV ABS BV NK<br />

WS Series International Standard Conformance List<br />

Safety Certification<br />

Marine Approvals<br />

IEC JIS EN GB<br />

UL CSA LR GL DNV ABS BV NK<br />

International Japan Europe<br />

China<br />

USA<br />

Canada<br />

UK Germany Norway USA France Japan<br />

Standards<br />

• Compliance with worldwide standards (IEC/JIS/EN/GB/UL/CSA)<br />

• Applicable to marine approvals<br />

• New design with Laser Marking<br />

• All products with lsolation function<br />

• RoHS compliance<br />

RoHS…The Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment<br />

■ Full range of WS Series (up to 1600AF)<br />

MCCB<br />

ELCB<br />

AF 32(30) 63 125 160 250 400 630 800 1000 1250 1600<br />

NF-C NF30-CS NF63-CW<br />

NF-S NF32-SW NF63-SW<br />

NF1000-SEW<br />

NF-H<br />

NF-U<br />

NV-C<br />

NV-S<br />

NV-H<br />

NV-U<br />

NV30-CS<br />

NV32-SW<br />

NF63-HW<br />

NV63-CW<br />

NV63-SW<br />

NV63-HW<br />

NF125-CW<br />

NF125-SW<br />

NF125-SGW<br />

NF125-HW<br />

NF125-HGW<br />

NF125-RGW<br />

NF125-UGW<br />

NV125-CW<br />

NV125-SW<br />

NV125-HW<br />

NV125-RW<br />

NF160-SW<br />

NF160-SGW<br />

NF160-HW<br />

NF160-HGW<br />

NF250-CW<br />

NF250-SW<br />

NF250-SGW<br />

NF250-HW<br />

NF250-HGW<br />

NF250-RGW<br />

NF250-UGW<br />

NV250-CW<br />

NV250-SW<br />

NV250-SEW<br />

NV250-HW<br />

NV250-HEW<br />

NV250-RW<br />

NF400-CW<br />

NF400-SW<br />

NF400-SEW<br />

NF400-HEW<br />

NF400-REW<br />

NF400-UEW<br />

NV400-CW<br />

NV400-SW<br />

NV400-SEW<br />

NV400-HEW<br />

NV400-REW<br />

NF630-CW<br />

NF630-SW<br />

NF630-SEW<br />

NF630-HEW<br />

NF630-REW<br />

NV630-CW<br />

NV630-SW<br />

NV630-SEW<br />

NV630-HEW<br />

NF800-CEW<br />

NF800-SEW<br />

NF800-SDW<br />

NF800-HEW<br />

NF800-REW<br />

NF800-UEW<br />

NV800-SEW<br />

NV800-HEW<br />

NF250-SGW 3P<br />

NF1250-SEW<br />

NF1250-SDW<br />

NF1600-SEW<br />

NF1600-SDW<br />

3


High-Performance<br />

Downsizing,<br />

New Digital ETR<br />

World Super<br />

Series<br />

■ 400AF, 630AF & 800AF models easier to use<br />

● 630AF models downsized to the size of 400AF model, contributing to<br />

compact panels and simplification of design.<br />

● MCCB-AC/DC common use (excl. Electronic trip type)<br />

3-pole:available up to 400VDC, 4-pole:available up to 500VDC<br />

(NF400-SW, NF630-SW)<br />

Previous<br />

210<br />

New<br />

140<br />

● Improved breaking capacity at 690VAC (NF400-HEW, NF630-HEW)<br />

275<br />

257<br />

Previous<br />

Icu/Ics<br />

15/15 kA<br />

New<br />

Icu/Ics<br />

35/18 kA<br />

Volume<br />

60% downsized<br />

● Improved breaking capacity at 400/415VAC (NF400-SEW, NF630-SW/SEW, NF800-SEW)<br />

Previous<br />

Icu/Ics<br />

45/45 kA<br />

New<br />

Icu/Ics<br />

50/50 kA<br />

■ NEW Digital ETR (Electronic Trip Relay) for<br />

NF1000-SEW, NF1250-SEW & NF1600-SEW<br />

● Installed digital ETR same as Electronic relay for under 800AF<br />

• Multi adjustment available (Long time delay, short time delay,<br />

Instantaneous, pre-alarm characteristics):easier coordination with upper<br />

breakers.<br />

• Pre-alarm equipped as Standard:LED turned on when load current<br />

exceeds pre-alarm setting current.<br />

• Suitable for use as a main breaker:isolation comformity to IEC Standard.<br />

Rated current<br />

Long time-delay<br />

operating time<br />

Current setting<br />

Short time-delay<br />

tripping current<br />

Short time-delay<br />

operating time<br />

Pre-alarm<br />

current<br />

Instantaneous<br />

tripping current<br />

Time (s)<br />

1 x 10 4 Ir<br />

1 x 10 3<br />

1 x 10 2<br />

10<br />

1<br />

0.1<br />

0.01<br />

Previous<br />

Current setting<br />

Is<br />

Current (A)<br />

Short-delay<br />

tripping current<br />

Time (s)<br />

New<br />

1<br />

Ir<br />

Current setting<br />

1 x 10 3<br />

1 x 10 2<br />

Ip<br />

TL<br />

Pre-alarm<br />

10 current<br />

1<br />

Is<br />

Load current<br />

0.1<br />

Ts<br />

0.01<br />

x 104 Current (A)<br />

High-voltage fuse-<br />

Allowable short-time<br />

characteristics<br />

Long-delay operating time<br />

Ii<br />

Short-delay<br />

tripping current<br />

Short-delay<br />

operating time<br />

Switch<br />

with fuse<br />

Instantaneous tripping current<br />

Current-converted value<br />

on the high-voltage side<br />

High<br />

voltage<br />

Low<br />

voltage<br />

Transformer<br />

NFB<br />

(electronic)<br />

M<br />

Load<br />

4


Reliable<br />

High reliability, Best performance<br />

■ Technology for WS Series<br />

Relay<br />

• Relay-unit Thermal type & Electronic type<br />

• AC/DC common use<br />

• Thermal adjustable range is expanded.<br />

Mechanism<br />

• Isolation suitability<br />

• Class ll insulation<br />

• Increased operating cycles<br />

Breaking Performance<br />

• Increased lcu<br />

• High voltage<br />

• Ics=100% lcu<br />

JPT<br />

Terminal<br />

• IP20 Mold-cover Finger<br />

protection<br />

• Front compression terminal<br />

⇔ Box terminal ⇔ Rear ⇔<br />

PM<br />

Internal Accessories<br />

Shunt-less<br />

Advanced ISTAC<br />

PA Auto-Puffer<br />

External Accessories<br />

• Cassette-type accessories<br />

• Wide range of Rated Voltage<br />

• Electric operators<br />

High speed type<br />

Isolation suitability<br />

• IP20 PM with Safety Device<br />

• Handle Lock Device<br />

• R/V handle<br />

• IP40 Terminal cover<br />

[PA Auto-Puffer]<br />

Adopted on SGW,<br />

Polymer Ablation type Auto-Puffer [ HGW, RGW, UGW]<br />

[JPT]<br />

Adopted on SGW,<br />

Jet Pressure Trip Mechanism [ HGW, RGW, UGW]<br />

[Advanced ISTAC]<br />

Adopted on SGW,HGW,<br />

Advanced Impulsive Slot-Type Accelerator [<br />

RGW, UGW ]<br />

[Shunt-less]<br />

Adopted on SGW,<br />

Shunt-less Current Flow Technology [ HGW, RGW, UGW]<br />

Double plates conductors hold the movable conductor without<br />

flexible wires. This shunt-less structure achieves the increased<br />

operating cycles.<br />

Holder<br />

Movable contact<br />

Endurance<br />

(C-O cycles)<br />

(times)<br />

50,000<br />

40,000<br />

Electrical<br />

Mechanical<br />

30,000<br />

20,000<br />

10,000<br />

0<br />

NF125-SGW/HGW NF160-SGW/HGW NF250-SGW/HGW<br />

Spring<br />

Movable contact<br />

revolving shaft<br />

During revolution the movable contact is constantly<br />

in contact with the holder, maintaining current flow.<br />

5


LN326N429-11<br />

MADE IN JAPAN<br />

I<br />

MADE IN JAPAN<br />

LN326N433-1<br />

World Super<br />

Series<br />

■ Best performance of SGW / HGW / RGW / UGW<br />

Breaking Capacity lcu/lcs<br />

(kA) 200 200 200 200 200<br />

200<br />

200<br />

125<br />

150<br />

125 125 125 125 125<br />

100<br />

100<br />

85 75 75<br />

70<br />

65<br />

50<br />

36<br />

50<br />

36<br />

25 30<br />

36 36<br />

30 20<br />

U(UGW)<br />

0<br />

230VAC<br />

R(RGW)<br />

380VAC<br />

400VAC 415VAC 8 H(HGW)<br />

440VAC<br />

500VAC S(SGW) Series<br />

690VAC<br />

Max. peak current (kA)<br />

(10 6 )<br />

MAX. I 2 t (A 2 • s)<br />

200<br />

100<br />

80<br />

60<br />

40<br />

20<br />

10<br />

8<br />

6<br />

4<br />

2<br />

Max. let-through peak current (kA) (400VAC)<br />

Prospective short-circuit<br />

current asym. peak<br />

NF250-HGW<br />

NF250-UGW<br />

1 1 2 4 6 8 10 20 40 60 80 100 200<br />

10<br />

8<br />

6<br />

4<br />

2<br />

1<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0.1<br />

0.08<br />

0.06<br />

Short-Circuit Current, sym.r.m.s.(kA)<br />

I 2 t let-through characteristics (400VAC)<br />

NF250-HGW<br />

NF250-UGW<br />

0.04<br />

1 2 4 6 8 10 20 40 60 80 100 200<br />

Short-Circuit Current, sym.r.m.s.(kA)<br />

■ 2 types of Relay for SGW / HGW / RGW / UGW<br />

Thermal Adjustable Relay<br />

6 8<br />

li(DC)=1.3Xli(AC) 4 10<br />

li(X250A AC)<br />

T<br />

lr<br />

li<br />

MODEL<br />

RT 250<br />

ln 250 A<br />

50/60Hz<br />

3P3E<br />

200<br />

160<br />

250<br />

lr(A)<br />

Rating ln(A) 25 40 63 100 125 160 250<br />

Type<br />

NF250-SGW/HGW<br />

NF160-SGW/HGW<br />

NF125-SGW/HGW Hi<br />

Lo<br />

Tripping threshold lr (A)<br />

Neutral protection<br />

(note 1) 4P3E<br />

4P4E<br />

Overload Protection (Thermal)<br />

16-25 25-40 40-63 63-100 80-125 125-160 160-250<br />

No Protection<br />

1 lr<br />

Short-Circuit Protection (Magnetic)<br />

Fixed<br />

Adjustable<br />

Tripping threshold li<br />

10ln (AC), 13ln (DC) 4 to 10ln (AC), 5.2 to 13ln(DC)<br />

Note: (1) The type 4P3E is standard. If the type 4P4E is required, specify the type 4P4E separately and explicitly.<br />

Thermal type unit<br />

lr li l<br />

Electronic Relay<br />

T<br />

MODEL<br />

RE250 ln 250 A<br />

AC only<br />

50/60Hz<br />

Ir (A)<br />

TEST T L(s) Is (XIr)<br />

Ts (s)<br />

200<br />

160<br />

60 80<br />

4 5<br />

6<br />

2<br />

3.5<br />

1<br />

3<br />

7<br />

2.5<br />

8<br />

125<br />

250 12<br />

100 2<br />

10 0.6<br />

T<br />

lp<br />

TL<br />

lr<br />

Ii<br />

ls<br />

Ts<br />

Ip<br />

(X250A)<br />

6<br />

TL<br />

Ir<br />

Is<br />

Ts<br />

8 10<br />

12<br />

3 4 14 7<br />

Ii<br />

7.5<br />

70%<br />

li<br />

Ip (XIr)<br />

8<br />

8.5 9<br />

9.5<br />

l<br />

PAL<br />

10<br />

4P3E<br />

OVER<br />

I<br />

pN<br />

4P4E<br />

Rating<br />

Type<br />

ln(A) (40C) 32 63 100 125 160 250<br />

NF250-SGW/HGW<br />

NF160-SGW/HGW<br />

Hi<br />

NF125-SGW/HGW<br />

Lo<br />

Tripping threshold lr (A)<br />

Tripping time TL(s)<br />

LTD<br />

Neutral protection (Slectable)<br />

STD<br />

INST<br />

PAL<br />

Pickup current ls<br />

Tripping time Ts(s)<br />

Tripping threshold li<br />

Pickup current lp<br />

Operating time Tp<br />

70%-LED (green)<br />

PAL-LED (orange)<br />

Over-LED (red)<br />

Overload Protection<br />

16-32 32-63 63-100 75-125 80-160 125-250<br />

12-60-80-100 step adjustable (at 2 lr)<br />

0-1 lr (Step adjustable)<br />

Short-Circuit Protection<br />

2-2.5-3-3.5-4-5-6-7-8-10 lr step adjustable<br />

0.06-0.1-0.2-0.3 step adjustable (at 1.5 ls)<br />

4 to 14 ln continuous adjustable<br />

Pre-Alarm (for Indication)<br />

0.7-0.75-0.8-0.85-0.9-0.95-1.0 lr step adjustable<br />

TL/2<br />

Indicator (LED)<br />

Lights at 0.7 lr<br />

Flashs at lp and Lights at over Tp<br />

Lights at 1.15 lr<br />

Electronic type unit<br />

6


Best Solution<br />

Plenty of Accessories, Easy installation<br />

Internal Accessories<br />

Internal accessories become easier to use by adopting a cassette type.<br />

Common use of different voltages realizes the major reduction in types.<br />

The UVT for ELCB is also available. Time delay type variations have<br />

also been expanded, offering a wide range of applications.<br />

3 Way Lead Wire (Selectable)<br />

Vertical Lead-wire Terminal Block (SHT)<br />

Previous models<br />

WS Series (New)<br />

SHT<br />

voltuge<br />

AC (V)<br />

DC (V)<br />

(24), (48), 100-120, 200-240,<br />

380-450, (440-550)<br />

(12), (24), (36), (48), 100, (110), (125), (220)<br />

24-48, 100-240, 380-550<br />

12, 24-36, 36-48, 100-125, 220-250<br />

UVT<br />

voltuge<br />

AC (V)<br />

100-110, (100-120), 200-220, (220-240),<br />

(380-415), 400-440, (440-480), (500-550)<br />

DC (V) (24), (48), 100, (110)<br />

24/48, 100-110/120-130, 200-220/230-250,<br />

380-415/440-480, 500-550/690<br />

24/48, 100/110, 110/125<br />

Lead-wire to Line side<br />

Flying Lead-wire<br />

Cassette-type Accessories<br />

Cassette-type accessories give greater flexbility when<br />

upgrading circuits.<br />

Easier ordering and one-touch simple installation become<br />

possible. The insulation function increases its safety.<br />

Fits all breaker series<br />

The alarm switch (AL), auxiliary switch (AX), shunt trip (SHT),<br />

and undervoltage trip (UVT) all come as cassette-type<br />

accessories to suit all breaker series.<br />

1.Push the trip button<br />

(PTT)<br />

2.Loosen the front<br />

cover screws<br />

3.Open the front<br />

cover<br />

4.Install the<br />

accessories<br />

5.Close the front cover<br />

and tighten the screws.<br />

External Accessories<br />

Hight-speed Motor Device<br />

Motor devices for 125-250AF become easier to use:contributing to the<br />

simple installation.<br />

Adoption of a spring charge mechanism for high-speed operation<br />

(0.05~0.1seconds)<br />

Swift and simple installation by tightening only two screws.<br />

Power Supply Module<br />

External Handle<br />

Adoption of a safer and easy to operate handle.<br />

Complying with protection degree IP65.<br />

Isolation function achieved through combination with the breaker unit.<br />

Structured to allow relay adjustments after installation as well.<br />

Equipped with cylinder key (option) to prevent false operation.<br />

V-Handle<br />

R-Handle<br />

IP-20PM with Safety Device<br />

[Adopted on SGW, HGW]<br />

Specialized for 3-and4-pole use (2 pole incompatible).<br />

Complies with the protection degree IP20.<br />

Safety device supplied as an option.<br />

May be connected with up to nine leads (for PLT).<br />

May be modified from front connection to rear connection.<br />

(Note: Modification by end users not authorized)<br />

IP20: Finger protection.<br />

(IP-20PM)<br />

7


World Super<br />

Series<br />

Product design which pursues greater ease of use by wide variations<br />

IP-20 Terminal Connection<br />

With the SGW, HGW,<br />

connection safety has been<br />

increased.<br />

Standard IP-20 protection<br />

degree ensured.<br />

Terminal Cover<br />

Major improvements have been achieved<br />

in front connection terminal safety.<br />

With terminal covers, IP40 protection<br />

degree is ensured.<br />

(Type “SGW, HGW, RGW, UGW”)<br />

Variable Connections<br />

Compatible with various<br />

connection methods.<br />

Solderless terminals are<br />

now built inside the<br />

breaker contrary to the<br />

conventional style where<br />

terminals were built<br />

outside.<br />

Maximum connecting Cable of 185mm 2 (SGW/HGW).<br />

(Note: Certain models have externally attached terminals)<br />

IEC Rail Mounting for 32, 63AF<br />

The 32,63AF includes<br />

installation hooks to IEC rails,<br />

greatly simplifying installation<br />

works.<br />

Handle Locks<br />

With the WS Series, ON/OFF locking is<br />

possible with the padlock.<br />

Up to three padlocks may be attached.<br />

Customers are requested their own<br />

padlocks.<br />

ON Lock<br />

OFF Lock<br />

OFF Lock with 3 Padlock<br />

(Type “SGW, HGW, RGW, UGW”)<br />

Intelligent<br />

Measuring and communicating<br />

• MDU (Measuring Display Unit) with NF 250-800AF<br />

• Small and white measuring unit<br />

• Measuring data can be transmitted to PC or PLC through CC-Link<br />

• AL / AX with CC-Link transmission<br />

• Improved accuracy(Electric energy): ±2.5% of rated value → ±2.5% of true value<br />

Personal<br />

Computer<br />

By using various application software for PLC, users can also connect to the network<br />

SCADA system.<br />

MELSECNET/10<br />

Interface card<br />

MELSECNET/10<br />

CC-Link®<br />

PLC<br />

Interface<br />

Unit<br />

I/O Unit<br />

Eco Monitor Pro<br />

ME110S<br />

AE-SW<br />

MDU<br />

8


Product Skelton<br />

16<br />

10<br />

22<br />

17<br />

23<br />

18<br />

24<br />

19<br />

20<br />

5<br />

4<br />

21<br />

10<br />

9


World Super<br />

Series<br />

11 12 13<br />

7<br />

8<br />

9<br />

6<br />

1 MCCB<br />

2 Relay unit (Thermal type) (RT)*<br />

3 Relay unit (Electronic type) (RE)*<br />

4 Relay unit (Magnetic only type) (RM)*<br />

5 Relay unit (Switch-disconnector type)*<br />

6 Super current-limiting unit*<br />

7 Solderless (BOX) terminals<br />

8 Front connection nuts<br />

9 Rear connections<br />

10 Insulating barrier (BA-F)<br />

11 Small terminal cover (TC-S)<br />

12 Large terminal cover (TC-L)<br />

13 Rear terminal cover (BTC)<br />

14 Plug-in base (PM)<br />

15 Connections for Plug-in<br />

16 Mechanical interlock device (MI)<br />

17 OFF Lock with 3 Padlock (HLF3)<br />

18 Handle lock device (LC/HLF/HLN/HLS)<br />

19 Variable-depth operating handle (V type)<br />

20 Rotary operating handle (R type)<br />

21 Electrical operation device (MD)<br />

22 Alarm/Auxiliary switch device (AL/AX)<br />

23 Under voltage trip device (UVT)<br />

24 Shunt trip device (SHT)<br />

Note *: All the accessories are field mounting type<br />

except No.2, 3, 4, 5 and 6.<br />

15<br />

14<br />

1<br />

7<br />

8<br />

9<br />

3<br />

2<br />

11<br />

12<br />

13<br />

10


1. Series Configuration and List of Product Models<br />

Series Configuration<br />

Molded-case circuit breakers<br />

NF-C<br />

Economy type<br />

NF-S<br />

Standard type<br />

NF-H<br />

High-performance<br />

type<br />

NF-U<br />

Current limiting-type<br />

ultra breaker<br />

Earth-leakage circuit breakers<br />

NV-C<br />

Economy type<br />

NV-S<br />

Standard type<br />

NV-H<br />

High-performance<br />

type<br />

NV-U<br />

Ultra current-limiting<br />

type<br />

Motor-protection breakers<br />

MB<br />

Motor breaker<br />

Circuit protectors<br />

CP30-BA CP-B CP-S<br />

For equipment<br />

Miniature circuit breakers<br />

BH BH-P BH-S BH-PS BH-D6 BH-DN BV-D BV-DN KB-D<br />

NEMA-type for consumer unit<br />

DIN-series for general consumer unit<br />

11


1<br />

List of Product Models<br />

Series<br />

NF-C<br />

Economy type<br />

Molded-case circuit breaker<br />

Earth-leakage circuit breaker<br />

Motor-protection<br />

breaker<br />

NF-S<br />

Standard type<br />

NF-H<br />

High-performance type<br />

NF-U<br />

Ultra current-limiting type<br />

NV-C<br />

Economy type<br />

NV-S<br />

Standard type<br />

Frame A<br />

NV-H<br />

High-performance type<br />

NV-U<br />

Ultra current-limiting type<br />

32 (30) 63 125 (100) 160 250 400 630 800 1000 1250 1600<br />

NF30-CS NF63-CW NF125-CW NF250-CW NF400-CW NF630-CW<br />

NF32-SW<br />

NF63-SW<br />

NF63-HW<br />

NF125-SW NF160-SW NF250-SW NF400-SW NF630-SW NF800-SDW<br />

NF1250-SEW NF1600-SEW<br />

NF1000-SEW<br />

NF125-SGW NF160-SGW NF250-SGW NF400-SEW NF630-SEW NF800-SEW<br />

NF1250-SDW NF1600-SDW<br />

NF125-HW NF160-HW NF250-HW NF400-HEW NF630-HEW NF800-HEW<br />

NF125-HGW NF160-HGW NF250-HGW NF400-REW NF630-REW NF800-REW<br />

NF125-RGW NF250-RGW NF400-UEW NF800-UEW NF1250-UR<br />

NF125-UGW<br />

NF250-UGW<br />

NV30-CS NV63-CW NV125-CW NV250-CW NV400-CW NV630-CW<br />

NV32-SW<br />

NV63-SW<br />

NV63-HW<br />

NV125-SW<br />

NV125-HW<br />

NV125-RW<br />

NV250-SW NV400-SW NV630-SW<br />

NV800-SEW<br />

NV250-SEW NV400-SEW NV630-SEW<br />

NV250-HW NV400-HEW<br />

NV630-HEW NV800-HEW<br />

NV250-HEW NV400-REW<br />

NV250-RW<br />

MB30-CS MB50-CW<br />

MB<br />

Motor breaker MB100-SW MB225-SW<br />

MB30-SW MB50-SW<br />

NF800-CEW<br />

NF-UL<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

UL listed products<br />

NV-UL<br />

Earth-leakage protector<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

Frame A<br />

Series<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

UL listed<br />

products<br />

Earth-leakage protector<br />

UL489 Listed<br />

Molded-case circuit breaker<br />

Details will be available<br />

( upon request. )<br />

50 100 150 225 250 400 600<br />

NF50-SWU NF100-CWU NF-SJW<br />

NF-SFW NF225-CWU NF-SKW NF-SLW<br />

NF100-SWU<br />

NF-HJW<br />

NV50-SWU<br />

NV100-SWU<br />

NV225-CWU<br />

NV-SKW<br />

Details will be available<br />

( upon request. )<br />

Miniature Circuit Breakers<br />

AF 60 100<br />

BH<br />

BH-P<br />

BH<br />

BH-S —<br />

BH-PS —<br />

DIN Series<br />

AF 63 and less<br />

MCB<br />

RCCB<br />

RCBO<br />

Isolating<br />

switch<br />

BH-D6<br />

BH-DN<br />

BV-D<br />

BV-DN<br />

KB-D<br />

Circuit Protectors<br />

AF 30 and less<br />

CP30-BA<br />

CP CP-B<br />

CP-S<br />

12


2. Detailed Specifications<br />

Molded-Case Circuit Breakers<br />

Series<br />

Frame Size<br />

C series<br />

30<br />

S series C series S series<br />

H series<br />

C series<br />

32<br />

63<br />

63<br />

63<br />

125<br />

Photo<br />

Type name<br />

NF30-CS<br />

NF32-SW<br />

NF63-CW<br />

NF63-SW<br />

NF63-HW<br />

NF125-CW<br />

Rated current In (Amp.)<br />

Rated ambient temperature (°C)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated<br />

short-circuit<br />

breaking<br />

capacities (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC<br />

Suitability for isolation<br />

Utilization category<br />

Reverse connection (terminals unmarked)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Pollution degree<br />

without current<br />

Number of operating cycles<br />

Overall dimensions (mm)<br />

with current<br />

690V<br />

525V<br />

500V<br />

440V<br />

415V<br />

400V<br />

380V<br />

230V<br />

250V<br />

300V<br />

440V-In/2<br />

440V-In<br />

690V-In/2<br />

690V-In<br />

a<br />

b<br />

c<br />

ca<br />

Mass of front-face type (kg)<br />

Screw terminal<br />

Front Solderless (box) terminal (SL)<br />

Fixed<br />

Busbar terminal<br />

Installation<br />

and<br />

Rear<br />

(B)<br />

connections<br />

Rear<br />

(PM)<br />

Plug-in<br />

Rear/front IP20<br />

(PM-IP)<br />

IEC 35mm<br />

rail<br />

Mounting hook (option)<br />

Adapter (option)<br />

Alarm switch<br />

(AL)<br />

Cassette-type Auxiliary switch<br />

(AX)<br />

accessories Shunt trip<br />

(SHT)<br />

(option) ✽5<br />

Undervoltage trip (UVT)<br />

Non-Synchronous Closing (UVT-N)<br />

Synchronous Closing (UVT-S)<br />

Accessorie’s with Lead-wire terminal block<br />

(SLT)<br />

connection with Internal terminal type<br />

(INT)<br />

(option) with Flying leads<br />

Built-in Pre-alarm (contact output) ✽3<br />

(PAL)<br />

accessories Overcurrent trip alarm ✽3<br />

(OAL)<br />

(option) Cylinder key lock Available soon<br />

(S)<br />

Dustproof<br />

Enclosure<br />

( I )<br />

Waterproof<br />

(W)<br />

Electrical operation device<br />

(MD)<br />

Mechanical interlock<br />

(MI)<br />

Handle lock device Handle lock<br />

(HL)<br />

(HL-S)<br />

Lock cover<br />

(LC)<br />

External<br />

accessories<br />

(V)<br />

External Door mounting<br />

(option)<br />

(S)<br />

operating<br />

handle<br />

(R)<br />

Mounted on breaker<br />

(F)<br />

Insulating Between phase<br />

(BA-F)<br />

barrier To ground<br />

(BA-G)<br />

Large<br />

(TC-L)<br />

Small<br />

(TC-S)<br />

Terminal<br />

cover<br />

Transparent<br />

(TTC)<br />

for rear connection<br />

(BTC)<br />

for plug-in<br />

(PTC)<br />

L/R<br />

G/L<br />

Marine approval<br />

BV<br />

DNV<br />

ABS<br />

Automatic tripping device<br />

Trip button<br />

Notes ✽1: Use two poles in the case of three-pole or four-pole products.<br />

In addition, wiring as shown to the right allows the three poles to be used<br />

for up to 400V DC and the four poles to be used for up to 500V DC.<br />

✽2: Use two poles in the case of three-pole or four-pole products.<br />

In addition, wiring as shown to the right allows the three poles to be used<br />

for up to 500V DC and the four poles to be used for up to 600V DC.<br />

✽3: Both PAL and OAL is not available. Only one specified.<br />

✽4: Specify if for DC use.<br />

✽5: Cassette-type accessories are not suitable for NF30-CS.<br />

a<br />

b<br />

ca c<br />

3 5 10<br />

15 20 30<br />

40<br />

2 3<br />

500<br />

–<br />

–<br />

–<br />

–<br />

1.5/1.5<br />

1.5/1.5<br />

1.5/1.5<br />

2.5/2 (240V)<br />

–<br />

–<br />

–<br />

A<br />

–<br />

4<br />

2<br />

10,000<br />

6,000 (415V)<br />

6,000 (415V)<br />

–<br />

–<br />

45 67.5<br />

96<br />

52<br />

67<br />

0.25 0.35<br />

●<br />

–<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

Hydraulicmagnetic<br />

–<br />

3 4 (5) 6 10 (15)<br />

16 20 25 (30) 32<br />

40<br />

2 3<br />

600<br />

–<br />

–<br />

2.5/1<br />

2.5/1<br />

2.5/1<br />

5/2<br />

5/2<br />

7.5/4<br />

2.5/1 ✽4 –<br />

–<br />

●<br />

A<br />

●<br />

6<br />

2<br />

10,000<br />

6,000<br />

6,000<br />

–<br />

–<br />

50 75<br />

130<br />

68<br />

90<br />

0.4 0.55<br />

●<br />

–<br />

–<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

– ●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

– ●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Hydraulicmagnetic<br />

Equipped<br />

3 4 (5) 6 10 (15) 16 20<br />

25 (30) 32 40 50 (60) 63<br />

40<br />

2 3<br />

600<br />

–<br />

–<br />

2.5/1<br />

2.5/1<br />

2.5/1<br />

5/2<br />

5/2<br />

7.5/4<br />

2.5/1 ✽4 –<br />

–<br />

●<br />

A<br />

●<br />

6<br />

2<br />

10,000<br />

6,000<br />

6,000<br />

–<br />

–<br />

50 75<br />

130<br />

68<br />

90<br />

0.45 0.6<br />

●<br />

–<br />

–<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

– ●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

– ●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Hydraulicmagnetic<br />

Equipped<br />

Line<br />

3-pole<br />

3 4 (5) 6 10 (15) 16 20<br />

25 (30) 32 40 50 (60) 63<br />

40<br />

40<br />

2 3 4 2 3 4<br />

7.5/4 ✽4<br />

600<br />

–<br />

–<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

15/8<br />

– 7.5/4 ✽4<br />

690<br />

2.5/1<br />

–<br />

7.5/4<br />

10/5<br />

10/5<br />

10/5<br />

10/5<br />

25/13<br />

–<br />

–<br />

●<br />

–<br />

●<br />

A<br />

●<br />

A<br />

●<br />

50<br />

6<br />

2<br />

15,000<br />

15,000<br />

8,000<br />

–<br />

–<br />

75 100 50<br />

6<br />

2<br />

15,000<br />

15,000<br />

8,000<br />

–<br />

-–<br />

75 100<br />

0.45<br />

130<br />

68<br />

90<br />

0.6 0.7 0.45<br />

130<br />

68<br />

90<br />

0.6 0.7<br />

●<br />

●<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

● – ● –<br />

● – ● –<br />

–<br />

– – ● –<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Hydraulicmagnetic<br />

Equipped<br />

Line<br />

Load<br />

–<br />

–<br />

–<br />

–<br />

–<br />

10 (15) 16 20 25 (30)<br />

32 40 50 (60) 63<br />

–<br />

4-pole<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Hydraulicmagnetic<br />

Equipped<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Load<br />

50 (60) 63 (75) 80<br />

100 125<br />

40<br />

2 3<br />

600<br />

–<br />

–<br />

7.5/4<br />

10/5<br />

10/5<br />

10/5<br />

10/5<br />

30/15<br />

7.5/4 ✽1<br />

–<br />

●<br />

A<br />

●<br />

8<br />

3<br />

10,000<br />

6,000<br />

6,000<br />

–<br />

–<br />

60 90<br />

130<br />

68<br />

90<br />

0.65 0.9<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Thermalmagnetic<br />

Equipped<br />

13


2<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

S series<br />

NF125-SW<br />

(15) 16 20 (30) 32 40 50<br />

(60) 63 (75) 80 100 125<br />

40<br />

690<br />

8/4<br />

18/5<br />

18/9<br />

25/13<br />

30/15<br />

30/15<br />

30/15<br />

50/25<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

20,000<br />

10,000<br />

1,000<br />

1,000<br />

130<br />

68<br />

90<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

125<br />

15/8 ✽1<br />

60<br />

0.7<br />

90 120<br />

0.95 1.3<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

4<br />

3<br />

2<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

NF125-SGW<br />

RT<br />

16–25 25–40 40–63<br />

63–100 80–125<br />

40<br />

–<br />

690<br />

8/8<br />

22/22<br />

30/30<br />

36/36<br />

36/36<br />

36/36<br />

36/36<br />

85/85<br />

A<br />

8<br />

3<br />

50,000<br />

40,000<br />

30,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

– –<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

NF125-SGW<br />

RE<br />

16–32 32–63 63–100<br />

75–125<br />

40<br />

3 4<br />

690<br />

8/8<br />

22/22<br />

30/30<br />

36/36<br />

36/36<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

–<br />

A<br />

8<br />

3<br />

50,000<br />

40,000<br />

30,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

105 140<br />

2.0 2.6<br />

105 140<br />

2.0 2.6<br />

–<br />

–<br />

–<br />

–<br />

4<br />

3<br />

2<br />

20/20 ✽2<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

NF125-HW<br />

(15) 16 20 (30) 32 40<br />

50 (60) 63 (75) 80 100<br />

40<br />

690<br />

10/5<br />

22/11<br />

30/15<br />

50/25<br />

50/25<br />

50/25<br />

50/25<br />

100/50<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

20,000<br />

10,000<br />

1,000<br />

1,000<br />

130<br />

68<br />

90<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

40/20 ✽1<br />

0.8 0.95<br />

90 120<br />

1.3<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

4<br />

3<br />

2<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

H series<br />

–<br />

Electronic<br />

125<br />

NF125-HGW<br />

RT<br />

16–25 25–40 40–63<br />

63–100 80–125<br />

40<br />

690<br />

20/20<br />

35/35<br />

50/50<br />

65/65<br />

70/70<br />

75/75<br />

75/75<br />

100/100<br />

A<br />

8<br />

3<br />

50,000<br />

40,000<br />

30,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

NF125-HGW<br />

RE<br />

16–32 32–63 63–100<br />

75–125<br />

40<br />

3 4<br />

690<br />

20/20<br />

35/35<br />

50/50<br />

65/65<br />

70/70<br />

75/75<br />

75/75<br />

100/100<br />

–<br />

–<br />

A<br />

8<br />

3<br />

50,000<br />

40,000<br />

30,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

Equipped<br />

105 140<br />

2.0 2.6<br />

105 140<br />

2.0 2.6<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

4<br />

3<br />

2<br />

40/40 ✽2<br />

U series<br />

NF125-RGW<br />

RT<br />

16–25 25–40<br />

40–63 63–100<br />

40<br />

2 3<br />

690<br />

25/25<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

–<br />

A<br />

8<br />

3<br />

50,000<br />

40,000<br />

30,000<br />

1,000<br />

1,000<br />

240<br />

105<br />

3.1<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Equipped<br />

NF125-UGW<br />

RT<br />

16–25 25–40<br />

40–63 63–100<br />

40<br />

690<br />

30/30<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

A<br />

8<br />

3<br />

50,000<br />

40,000<br />

30,000<br />

1,000<br />

1,000<br />

240<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Thermalmagnetic<br />

Equipped<br />

125<br />

–<br />

– –<br />

105 140<br />

3.1 3.9<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

4<br />

3<br />

2<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

14


2. Detailed Specifications<br />

Molded-Case Circuit Breakers<br />

Series<br />

Frame Size<br />

S series<br />

160<br />

H series<br />

160<br />

Photo<br />

Type name<br />

NF160-SW<br />

NF160-SGW<br />

RT<br />

NF160-SGW<br />

RE<br />

NF160-HW<br />

NF160-HGW<br />

RT<br />

NF160-HGW<br />

RE<br />

Rated current In (Amp.)<br />

125 150 160<br />

125–160<br />

80–160<br />

125 150 160<br />

125–160<br />

80–160<br />

Rated ambient temperature (°C)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated<br />

short-circuit<br />

breaking<br />

capacities (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC<br />

Suitability for isolation<br />

Utilization category<br />

Reverse connection (terminals unmarked)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Pollution degree<br />

without current<br />

Number of operating cycles<br />

Overall dimensions (mm)<br />

with current<br />

690V<br />

525V<br />

500V<br />

440V<br />

415V<br />

400V<br />

380V<br />

230V<br />

250V<br />

300V<br />

440V-In/2<br />

440V-In<br />

690V-In/2<br />

690V-In<br />

a<br />

b<br />

c<br />

ca<br />

Mass of front-face type (kg)<br />

Screw terminal<br />

Front Solderless (box) terminal (SL)<br />

Fixed<br />

Busbar terminal<br />

Installation<br />

and<br />

Rear<br />

(B)<br />

connections<br />

Rear<br />

(PM)<br />

Plug-in<br />

Rear/front IP20<br />

(PM-IP)<br />

IEC 35mm<br />

rail<br />

Mounting hook (option)<br />

Adapter (option)<br />

Alarm switch<br />

(AL)<br />

Cassette-type Auxiliary switch<br />

(AX)<br />

accessories Shunt trip<br />

(SHT)<br />

(option)<br />

Undervoltage trip (UVT)<br />

Non-Synchronous Closing (UVT-N)<br />

Synchronous Closing (UVT-S)<br />

Accessorie’s with Lead-wire terminal block<br />

(SLT)<br />

connection with Internal terminal type<br />

(INT)<br />

(option) with Flying leads<br />

Built-in Pre-alarm (contact output) ✽3<br />

(PAL)<br />

accessories Overcurrent trip alarm ✽3<br />

(OAL)<br />

(option) Cylinder key lock Available soon<br />

(S)<br />

Dustproof<br />

Enclosure<br />

( I )<br />

Waterproof<br />

(W)<br />

Electrical operation device<br />

(MD)<br />

Mechanical interlock<br />

(MI)<br />

Handle lock device Handle lock<br />

(HL)<br />

(HL-S)<br />

Lock cover<br />

(LC)<br />

External<br />

accessories<br />

(V)<br />

External Door mounting<br />

(option)<br />

(S)<br />

operating<br />

handle<br />

(R)<br />

Mounted on breaker<br />

(F)<br />

Insulating Between phase<br />

(BA-F)<br />

barrier To ground<br />

(BA-G)<br />

Large<br />

(TC-L)<br />

Small<br />

(TC-S)<br />

Terminal<br />

cover<br />

Transparent<br />

(TTC)<br />

for rear connection<br />

(BTC)<br />

for plug-in<br />

(PTC)<br />

L/R<br />

G/L<br />

Marine approval<br />

BV<br />

DNV<br />

ABS<br />

Automatic tripping device<br />

Trip button<br />

Notes ✽1: Use two poles in the case of three-pole or four-pole products.<br />

In addition, wiring as shown to the right allows the three poles to be used<br />

for up to 400V DC and the four poles to be used for up to 500V DC.<br />

✽2: Use two poles in the case of three-pole or four-pole products.<br />

In addition, wiring as shown to the right allows the three poles to be used<br />

for up to 500V DC and the four poles to be used for up to 600V DC.<br />

✽3: Both PAL and OAL is not available. Only one specified.<br />

a<br />

b<br />

ca c<br />

2<br />

40<br />

3<br />

690<br />

–<br />

–<br />

15/8<br />

25/13<br />

30/15<br />

30/15<br />

30/15<br />

50/25<br />

15/8 ✽1<br />

–<br />

●<br />

A<br />

●<br />

6<br />

2<br />

12,000<br />

4,000<br />

4,000<br />

–<br />

–<br />

1,000<br />

1,000<br />

105 140 105 140 105 140<br />

165<br />

165<br />

165<br />

68<br />

86<br />

86<br />

92<br />

110<br />

110<br />

1.3 1.5 1.9 2.0 2.6 2.0 2.6<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

–<br />

●<br />

●<br />

● –<br />

–<br />

–<br />

● – ● – ● –<br />

● – ● – ● –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

● ● ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

4<br />

2<br />

40<br />

3<br />

690<br />

8/8<br />

22/22<br />

30/30<br />

36/36<br />

36/36<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

20/20 ✽2<br />

●<br />

A<br />

●<br />

8<br />

3<br />

40,000<br />

30,000<br />

20,000<br />

1,000<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

40<br />

3 4<br />

690<br />

8/8<br />

22/22<br />

30/30<br />

36/36<br />

36/36<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

–<br />

●<br />

A<br />

●<br />

8<br />

3<br />

40,000<br />

30,000<br />

20,000<br />

1,000<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

4<br />

Line<br />

Electronic<br />

Equipped<br />

3-pole<br />

2<br />

40<br />

3 4 2<br />

40<br />

3 4<br />

690<br />

5/3<br />

–<br />

30/8<br />

50/13<br />

50/13<br />

50/13<br />

50/13<br />

100/25<br />

690<br />

20/20<br />

35/35<br />

50/50<br />

65/65<br />

70/70<br />

75/75<br />

75/75<br />

100/100<br />

40/20 ✽1<br />

–<br />

–<br />

●<br />

40/40 ✽2<br />

●<br />

A<br />

●<br />

A<br />

●<br />

6<br />

2<br />

12,000<br />

4,000<br />

4,000<br />

1,000<br />

1,000<br />

8<br />

3<br />

40,000<br />

30,000<br />

20,000<br />

1,000<br />

1,000<br />

105 140 105 140<br />

165<br />

68<br />

92<br />

165<br />

86<br />

110<br />

1.3 1.5 1.9 2.0 2.6<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

– ● – ●<br />

– ● – ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

Line<br />

Load<br />

4-pole<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

Load<br />

40<br />

3 4<br />

690<br />

20/20<br />

35/35<br />

50/50<br />

65/65<br />

70/70<br />

75/75<br />

75/75<br />

100/100<br />

–<br />

–<br />

●<br />

A<br />

●<br />

8<br />

3<br />

40,000<br />

30,000<br />

20,000<br />

1,000<br />

1,000<br />

105 140<br />

165<br />

86<br />

110<br />

2.0 2.6<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

15


2<br />

C series S series H series U series<br />

3 4 3 4<br />

NF250-SW<br />

(100) 125 150 175<br />

200 225 250<br />

40<br />

690<br />

–<br />

–<br />

15/8<br />

25/13<br />

30/15<br />

30/15<br />

30/15<br />

50/25<br />

–<br />

A<br />

6<br />

2<br />

12,000<br />

4,000<br />

4,000<br />

–<br />

-–<br />

165<br />

68<br />

92<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

105 140<br />

2.0 2.6<br />

105 140<br />

2.0 2.6<br />

250<br />

NF250-SGW<br />

RT<br />

125–160 160–250<br />

40<br />

690<br />

8/8<br />

22/22<br />

30/30<br />

36/36<br />

36/36<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

15,000<br />

10,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

NF250-SGW<br />

RE<br />

125–250<br />

40<br />

690<br />

8/8<br />

22/22<br />

30/30<br />

36/36<br />

36/36<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

15,000<br />

10,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

Electronic<br />

Equipped<br />

NF250-HW<br />

125 150 175<br />

200 225 250<br />

40<br />

690<br />

5/3<br />

–<br />

30/8<br />

50/13<br />

50/13<br />

50/13<br />

50/13<br />

100/25<br />

–<br />

A<br />

6<br />

2<br />

12,000<br />

4,000<br />

4,000<br />

1,000<br />

1,000<br />

165<br />

68<br />

92<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

NF250-HGW<br />

RT<br />

125–160<br />

160–250<br />

40<br />

690<br />

20/20<br />

35/35<br />

50/50<br />

65/65<br />

70/70<br />

75/75<br />

75/75<br />

100/100<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

15,000<br />

10,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

250<br />

NF250-HGW<br />

RE<br />

125–250<br />

40<br />

–<br />

690<br />

20/20<br />

35/35<br />

50/50<br />

65/65<br />

70/70<br />

75/75<br />

75/75<br />

100/100<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

15,000<br />

10,000<br />

1,000<br />

1,000<br />

165<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

105<br />

3.1<br />

2 3<br />

250<br />

NF250-RGW<br />

RT<br />

125–160 160–225<br />

40<br />

690<br />

25/25<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

15,000<br />

10,000<br />

1,000<br />

1,000<br />

240<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

Thermalmagnetic<br />

Thermalmagnetic<br />

Equipped<br />

NF250-UGW<br />

RT<br />

125–160 160–225<br />

40<br />

690<br />

30/30<br />

–<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

–<br />

A<br />

8<br />

3<br />

25,000<br />

15,000<br />

10,000<br />

1,000<br />

1,000<br />

240<br />

86<br />

110<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Equipped<br />

2 3 4<br />

2 3 4<br />

1.3 1.5 1.9<br />

15/8 ✽1<br />

20/20 ✽2 40/40 ✽2<br />

40/20 ✽1<br />

–<br />

105 140 105 140<br />

2.0 2.6<br />

105 140 105 140<br />

2.0 2.6<br />

105 140<br />

3.1 3.9<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

4<br />

3<br />

2<br />

1.9<br />

1.5<br />

1.3<br />

4<br />

3<br />

2 4<br />

3<br />

2<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

● ● –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

● ● ● ●<br />

–<br />

250<br />

NF250-CW<br />

(100) 125 150 175<br />

200 225 250<br />

40<br />

2 3<br />

10/5 ✽1<br />

105<br />

600<br />

–<br />

–<br />

10/5<br />

15/8<br />

18/9<br />

18/9<br />

18/9<br />

35/18<br />

–<br />

A<br />

6<br />

2<br />

8,000<br />

4,000<br />

4,000<br />

–<br />

–<br />

165<br />

68<br />

92<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

1.3 1.5<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

16


2. Detailed Specifications<br />

Molded-Case Circuit Breakers<br />

Series<br />

Frame Size<br />

C series<br />

400<br />

S series<br />

400<br />

400<br />

H series<br />

400<br />

Photo<br />

Type name<br />

NF400-CW<br />

NF400-SW<br />

NF400-SEW<br />

NF400-HEW<br />

NF400-REW<br />

Rated current In (Amp.)<br />

250 300 350 400<br />

250 300 350 400<br />

200~400<br />

adjustable<br />

200~400<br />

adjustable<br />

200~400<br />

adjustable<br />

Rated ambient temperature (°C)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated<br />

short-circuit<br />

breaking<br />

capacities (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC<br />

Suitability for isolation<br />

Utilization category<br />

Rated short-time withstand current Icw (kA)<br />

Reverse connection (terminals unmarked)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Pollution degree<br />

a ca c<br />

Overall dimensions (mm)<br />

b<br />

690V<br />

500V<br />

440V<br />

415V<br />

400V<br />

380V<br />

230V<br />

250V<br />

a<br />

b<br />

c<br />

ca<br />

Mass of front-face type (kg)<br />

Screw terminal<br />

Front Solderless (box) terminal (SL)<br />

Installation Fixed<br />

Busbar terminal<br />

and<br />

connections<br />

Rear<br />

(B)<br />

Rear<br />

(PM)<br />

Plug-in<br />

Rear/front IP20<br />

(PM-IP)<br />

Alarm switch<br />

(AL)<br />

Cassette-type Auxiliary switch<br />

(AX)<br />

accessories Shunt trip<br />

(SHT)<br />

(option)<br />

Undervoltage trip (UVT)<br />

Non-Synchronous Closing (UVT-N)<br />

Synchronous Closing (UVT-S)<br />

Accessorie’s with Lead-wire terminal block<br />

(SLT)<br />

connection with Internal terminal type<br />

(INT)<br />

(option) with Flying leads<br />

Built-in Pre-alarm (contact output) ✽3<br />

(PAL)<br />

accessories<br />

(option)<br />

Overcurrent trip alarm ✽3<br />

Trip indicator<br />

(OAL)<br />

(TI)<br />

(S)<br />

Dustproof<br />

Enclosure<br />

( I )<br />

Waterproof<br />

(W)<br />

Motoroperated<br />

type<br />

Electrical<br />

(MD)<br />

operation<br />

device<br />

Springcharge<br />

type<br />

(MDS)<br />

Mechanical interlock<br />

(MI)<br />

(HL)<br />

Handle lock device Handle lock<br />

(HL-S)<br />

External Lock cover<br />

(LC)<br />

accessories<br />

(option)<br />

(V)<br />

External Door mounting<br />

(S)<br />

operating<br />

handle<br />

(R)<br />

Mounted on breaker<br />

(F)<br />

Insulating Between phase<br />

(BA-F)<br />

barrier To ground<br />

(BA-G)<br />

Large<br />

(TC-L)<br />

Small<br />

(TC-S)<br />

Terminal<br />

cover<br />

Transparent<br />

(TTC)<br />

for rear connection<br />

(BTC)<br />

for plug-in<br />

(PTC)<br />

L/R<br />

G/L<br />

Marine approval<br />

BV<br />

DNV<br />

ABS<br />

Automatic tripping device<br />

Trip button<br />

40<br />

2 3<br />

690<br />

–<br />

15/8<br />

25/13<br />

36/18<br />

36/18<br />

40/20<br />

50/25<br />

20/10 ✽4<br />

●<br />

A<br />

–<br />

●<br />

8<br />

3<br />

140<br />

257<br />

103<br />

134<br />

4.7 5.5<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

Notes ✽1: In case of solderless terminal, interrupting capacity reduces: ( / ).<br />

✽2: Solid state relay output is option . Please specify if other output is<br />

necessary. (Standard type is thus SLT equipped.)<br />

✽3: Both PAL and OAL is not available. Only one specified.<br />

✽4: Use two poles in the case of three-pole or four-pole products.<br />

In addition, wiring as shown to the right allows the three poles to be used<br />

for up to 400V DC and the four poles to be used for up to 500V DC.<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

Thermalmagnetic<br />

Equipped<br />

40<br />

2 3 4<br />

690<br />

10/10(5/5) ✽1<br />

30/30(25/25) ✽1<br />

42/42(36/36) ✽1<br />

45/45(36/36) ✽1<br />

45/45(36/36) ✽1<br />

50/50(42/42) ✽1<br />

85/85(65/65) ✽1<br />

40/40 ✽4<br />

●<br />

A<br />

–<br />

●<br />

8<br />

3<br />

140 185<br />

4.9<br />

257<br />

103<br />

155<br />

5.7 7.5<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

Thermalmagnetic<br />

Equipped<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Line<br />

40<br />

3 4<br />

690<br />

10/10(5/5) ✽1<br />

30/30(25/25) ✽1<br />

42/42(36/36) ✽1<br />

50/50(36/36) ✽1<br />

50/50(36/36) ✽1<br />

50/50(42/42) ✽1<br />

85/85(65/65) ✽1<br />

–<br />

●<br />

B<br />

5<br />

●<br />

8<br />

3<br />

140 185<br />

257<br />

103<br />

155<br />

6.5 8.3<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

● ✽2<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

3-pole<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

Electronic<br />

Equipped<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Line<br />

Load<br />

40<br />

3 4<br />

690<br />

35/18<br />

50/50<br />

65/65<br />

70/70<br />

70/70<br />

70/70<br />

100/100<br />

–<br />

●<br />

B<br />

5<br />

●<br />

8<br />

3<br />

140 185<br />

257<br />

103<br />

155<br />

6.5 8.3<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

Electronic<br />

Equipped<br />

4-pole<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Load<br />

40<br />

3<br />

690<br />

–<br />

70/35<br />

125/63<br />

125/63<br />

125/63<br />

125/63<br />

150/75<br />

–<br />

●<br />

B<br />

5<br />

●<br />

8<br />

3<br />

140<br />

257<br />

103<br />

155<br />

6.5<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

Electronic<br />

Equipped<br />

17


2<br />

–<br />

C series<br />

S series<br />

630<br />

NF630-CW<br />

500 600 630<br />

40<br />

690<br />

–<br />

18/9<br />

36/18<br />

36/18<br />

36/18<br />

40/20<br />

50/25<br />

A<br />

8<br />

3<br />

257<br />

103<br />

257<br />

103<br />

257<br />

103<br />

155<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

Thermalmagnetic<br />

Equipped<br />

630<br />

H series<br />

630<br />

3 4<br />

140<br />

4<br />

3<br />

2<br />

U series<br />

400<br />

3 4<br />

140 280<br />

297 322<br />

NF400-UEW<br />

200~400<br />

adjustable<br />

–<br />

B<br />

5<br />

●<br />

8<br />

3<br />

200<br />

252<br />

–<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

40<br />

690<br />

–<br />

170/170<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

–<br />

–<br />

–<br />

16.7 26.1<br />

2 3<br />

20/10 ✽4<br />

5.2 6.0<br />

NF630-SW<br />

500 600 630<br />

40<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

50/50<br />

50/50<br />

85/85<br />

A<br />

155<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

40/40 ✽4<br />

140 185<br />

8.0<br />

6.2<br />

5.4<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

NF630-SEW<br />

300~630<br />

adjustable<br />

40<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

50/50<br />

50/50<br />

85/85<br />

B<br />

– – 7.6<br />

155<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

140<br />

6.5<br />

185<br />

8.3<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

8<br />

3<br />

8<br />

3<br />

257<br />

103<br />

3 4<br />

NF630-HEW<br />

300~630<br />

adjustable<br />

40<br />

690<br />

35/18<br />

50/50<br />

65/65<br />

70/70<br />

70/70<br />

70/70<br />

100/100<br />

B<br />

7.6<br />

155<br />

–<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

140 185<br />

6.5 8.3<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

8<br />

3<br />

630<br />

257<br />

103<br />

NF630-REW<br />

300~630<br />

adjustable<br />

40<br />

3<br />

690<br />

–<br />

70/35<br />

125/63<br />

125/63<br />

125/63<br />

125/63<br />

150/75<br />

B<br />

7.6<br />

155<br />

6.5<br />

–<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

Electronic<br />

Equipped<br />

–<br />

–<br />

8<br />

3<br />

140<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

18


2. Detailed Specifications<br />

Molded-Case Circuit Breakers<br />

Series<br />

Frame Size<br />

C series<br />

800<br />

S series<br />

800<br />

H series<br />

800<br />

Photo<br />

Type name<br />

NF800-CEW<br />

NF800-SDW<br />

NF800-SEW<br />

NF800-HEW<br />

NF800-REW<br />

Rated current In (Amp.)<br />

400~800<br />

adjustable<br />

(700) 800<br />

400~800<br />

adjustable<br />

400~800<br />

adjustable<br />

400~800<br />

adjustable<br />

Rated ambient temperature (°C)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated<br />

short-circuit<br />

breaking<br />

capacities (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

(50/60Hz)<br />

DC<br />

Suitability for isolation<br />

Utilization category<br />

Rated short-time withstand current low (kA)<br />

Reverse connection (terminals unmarked)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Pollution degree<br />

a ca c<br />

Overall dimensions (mm)<br />

b<br />

690V<br />

500V<br />

440V<br />

415V<br />

400V<br />

380V<br />

230V<br />

250V<br />

Mass of front-face type (kg)<br />

Screw terminal<br />

Front Solderless (box) terminal (SL)<br />

Installation Fixed<br />

Busbar terminal<br />

and<br />

connections<br />

Rear<br />

(B)<br />

Rear<br />

(PM)<br />

Plug-in<br />

Rear/front IP20<br />

(PM-IP)<br />

Alarm switch<br />

(AL)<br />

Cassette-type Auxiliary switch<br />

(AX)<br />

accessories Shunt trip<br />

(SHT)<br />

(option) ✽5<br />

Undervoltage trip (UVT)<br />

Non-Synchronous Closing (UVT-N)<br />

Synchronous Closing (UVT-S)<br />

Accessorie’s with Lead-wire terminal block<br />

(SLT)<br />

connection with Internal terminal type<br />

(INT)<br />

(option) with Flying leads<br />

Built-in Pre-alarm (contact output) ✽3<br />

(PAL)<br />

accessories<br />

(option)<br />

Overcurrent trip alarm ✽3<br />

Trip indicator<br />

(OAL)<br />

(TI)<br />

(S)<br />

Dustproof<br />

Enclosure<br />

( I )<br />

Waterproof<br />

(W)<br />

Motoroperated<br />

type<br />

Electrical<br />

(MD)<br />

operation<br />

device<br />

Springcharge<br />

type<br />

(MDS)<br />

Mechanical interlock<br />

(MI)<br />

(HL)<br />

Handle lock device Handle lock<br />

(HL-S)<br />

External<br />

Lock cover<br />

(LC)<br />

accessories<br />

(option)<br />

(V)<br />

External Door mounting<br />

(S)<br />

operating<br />

handle<br />

(R)<br />

Mounted on breaker<br />

(F)<br />

Insulating Between phase<br />

(BA-F)<br />

barrier To ground<br />

(BA-G)<br />

Large<br />

(TC-L)<br />

Small<br />

(TC-S)<br />

Terminal<br />

cover<br />

Transparent<br />

(TTC)<br />

for rear connection<br />

(BTC)<br />

for plug-in<br />

(PTC)<br />

L/R<br />

G/L<br />

Marine approval<br />

BV<br />

DNV<br />

ABS<br />

Automatic tripping device<br />

Trip button<br />

Notes ✽1: In case of solderless terminal, interrupting capacity reduces: ( / ).<br />

✽2: Solid state relay output is option . Please specify if other output is<br />

necessary. (Standard type is thus SLT equipped.)<br />

✽3: Both PAL and OAL is not available. Only one specified.<br />

✽4: Specify if for DC use.<br />

✽5: Cassette-type accessories are not suitable for NF1000-SW,<br />

NF1250-SW, NF1250-SDW, NF1600-SW, and NF1600-SDW.<br />

a<br />

b<br />

c<br />

ca<br />

40<br />

3<br />

690<br />

–<br />

18/9<br />

36/18<br />

36/18<br />

36/18<br />

40/20<br />

50/25<br />

–<br />

●<br />

B<br />

9.6<br />

●<br />

8<br />

3<br />

210<br />

275<br />

103<br />

155<br />

10.9<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

● ✽2<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Electronic<br />

Equipped<br />

40<br />

2<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

40/40 ✽4<br />

●<br />

A<br />

–<br />

●<br />

8<br />

3<br />

210<br />

275<br />

103<br />

155<br />

9<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

40<br />

3 4<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

50/50<br />

50/50<br />

85/85<br />

–<br />

●<br />

B<br />

9.6<br />

●<br />

8<br />

3<br />

210 280<br />

275<br />

103<br />

155<br />

10.9 14.2<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

● ✽2<br />

–<br />

●<br />

–<br />

● –<br />

● –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

–<br />

–<br />

–<br />

–<br />

40<br />

3 4<br />

690<br />

15/15<br />

50/50<br />

65/65<br />

70/70<br />

70/70<br />

70/70<br />

100/100<br />

–<br />

●<br />

B<br />

9.6<br />

●<br />

8<br />

3<br />

210 280<br />

275<br />

103<br />

155<br />

10.9 14.2<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

● –<br />

● –<br />

● –<br />

– –<br />

● –<br />

Electronic<br />

Equipped<br />

40<br />

3<br />

690<br />

–<br />

70/35<br />

125/63<br />

125/63<br />

125/63<br />

125/63<br />

150/75<br />

–<br />

●<br />

B<br />

9.6<br />

●<br />

8<br />

3<br />

210<br />

275<br />

103<br />

155<br />

10.9<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

–<br />

●<br />

Electronic<br />

Equipped<br />

19


2<br />

210 280<br />

406<br />

–<br />

B<br />

20<br />

●<br />

8<br />

3<br />

140<br />

190<br />

–<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

85/43<br />

85/43<br />

125/63<br />

–<br />

–<br />

23.5 30.7<br />

1000<br />

3 4<br />

NF1000-SEW<br />

40<br />

690<br />

–<br />

–<br />

– –<br />

– –<br />

–<br />

–<br />

–<br />

–<br />

–<br />

210 280<br />

406<br />

–<br />

B<br />

20<br />

●<br />

8<br />

3<br />

140<br />

190<br />

–<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

85/43<br />

85/43<br />

125/63<br />

–<br />

–<br />

23.5 30.7<br />

1250<br />

S series<br />

1600<br />

3 4<br />

NF1250-SEW<br />

40<br />

690<br />

–<br />

–<br />

–<br />

–<br />

–<br />

600~1250<br />

adjustable<br />

406<br />

40/20 ✽4<br />

A<br />

–<br />

●<br />

8<br />

3<br />

210<br />

140<br />

190<br />

22<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Thermalmagnetic<br />

Equipped<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

NF1250-SDW<br />

40<br />

2<br />

690<br />

1000 1250<br />

–<br />

–<br />

– –<br />

– –<br />

–<br />

210 280<br />

406<br />

–<br />

B<br />

20<br />

●<br />

8<br />

3<br />

140<br />

190<br />

–<br />

–<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

85/43<br />

85/43<br />

125/63<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

34.5 41.2<br />

3 4<br />

NF1600-SEW<br />

40<br />

690<br />

–<br />

–<br />

–<br />

–<br />

–<br />

800~1600<br />

adjustable<br />

406<br />

40/20 ✽4<br />

A<br />

–<br />

●<br />

8<br />

3<br />

210<br />

140<br />

190<br />

32<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

Magnetic<br />

Equipped<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

NF1600-SDW<br />

40<br />

2<br />

690<br />

1600<br />

210 280<br />

322<br />

–<br />

B<br />

9.6<br />

8<br />

3<br />

200<br />

252<br />

–<br />

–<br />

–<br />

–<br />

● ✽2<br />

–<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Equipped<br />

–<br />

35/35<br />

170/170<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

27.6 33.7<br />

– –<br />

800<br />

U series<br />

3 4<br />

NF800-UEW<br />

400~800<br />

adjustable<br />

500~1000<br />

adjustable<br />

40<br />

690<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

20


2. Detailed Specifications<br />

Earth-Leakage Circuit Breakers<br />

Series<br />

Frame size<br />

C series S series C series S series<br />

H series C series<br />

30<br />

32<br />

63<br />

63<br />

63<br />

125<br />

Photo<br />

Type name<br />

Rated current In (Amp.)<br />

Rated ambient temperature (°C)<br />

Number of poles<br />

Rated operational voltage Ue (AC V)<br />

NV30-CS<br />

5 10 15<br />

20 30<br />

40<br />

3<br />

NV32-SW<br />

(5) 6 10 (15) 16<br />

20 25 (30) 32<br />

40<br />

3<br />

NV63-CW<br />

(5) (10) (15) 16 20 25<br />

(30) 32 40 50 (60) 63<br />

40<br />

3<br />

NV63-SW<br />

(5) (10) (15) 16 20 25<br />

(30) 32 40 50 (60) 63<br />

40<br />

3<br />

NV63-HW<br />

(15) 16 20 25 (30)<br />

32 40 50 (60) 63<br />

40<br />

3<br />

NV125-CW<br />

(60) 63 (75) 80<br />

100 125<br />

40<br />

3<br />

✽6<br />

100–230<br />

100–440<br />

100–440<br />

100–440<br />

100–440<br />

100–440<br />

Multi-voltage type Multi-voltage type Multi-voltage type Multi-voltage type Multi-voltage type<br />

30,100 •200 •500 30,100 •200 •500 30,100 •200 •500 30,100 •200 •500 30,100 •200 •500<br />

High-speed type<br />

Rated current sensitivity I∆n (mA)<br />

30<br />

Selectable Selectable Selectable Selectable Selectable<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

0.04<br />

–<br />

0.04<br />

–<br />

0.04<br />

–<br />

0.04<br />

–<br />

0.04<br />

–<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

Time-delay type<br />

Max. operating time at 2I∆n (s)<br />

–<br />

–<br />

–<br />

–<br />

–<br />

0.45 •1.0 •2.0<br />

Selectable<br />

Inertial non-operating time at 2I∆n (s)<br />

Earth-leakage indication system<br />

–<br />

Button<br />

–<br />

Button<br />

–<br />

Button<br />

–<br />

Button<br />

–<br />

Button<br />

(0.1•0.5 •1.0)<br />

Button<br />

AC440V<br />

–<br />

5/2<br />

2.5/1<br />

7.5/4<br />

10/5<br />

10/5<br />

Rated short-circuit breaking capacity (kA)<br />

AC400V<br />

–<br />

5/2<br />

5/2<br />

7.5/4<br />

10/5<br />

10/5<br />

IEC60947-2 (Icu/Ics)<br />

AC230V 2.5/2<br />

10/5<br />

7.5/4<br />

15/8<br />

25/13<br />

30/15<br />

without current<br />

10,000<br />

10,000<br />

10,000<br />

15,000<br />

15,000<br />

10,000<br />

Number of operating cycles<br />

440V-In/2 6,000 (230V) 6,000<br />

6,000<br />

15,000<br />

15,000<br />

6,000<br />

with current<br />

440V-In 6,000 (230V) 6,000<br />

6,000<br />

8,000<br />

8,000<br />

6,000<br />

a ca c<br />

a<br />

67.5<br />

75<br />

75<br />

75<br />

75<br />

90<br />

Overall dimensions (mm)<br />

b<br />

96<br />

130<br />

130<br />

130<br />

130<br />

130<br />

b<br />

c<br />

ca<br />

52<br />

67<br />

68<br />

90<br />

68<br />

90<br />

68<br />

90<br />

68<br />

90<br />

68<br />

90<br />

Mass of front-face type (kg)<br />

0.4<br />

0.6<br />

0.65<br />

0.65<br />

0.65<br />

1.0<br />

Screw terminal<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Fixed<br />

Front Solderless (box) terminal (SL)<br />

Busbar terminal<br />

–<br />

–<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

Installation and<br />

Rear<br />

(B) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

connections<br />

Rear<br />

(PM) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Plug-in<br />

Rear/front IP20<br />

(PM-IP) –<br />

–<br />

–<br />

–<br />

–<br />

–<br />

IEC 35mm<br />

rail<br />

Mounting hook (option)<br />

Adapter (option)<br />

–<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

●<br />

Alarm switch<br />

(AL) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Cassette-type Auxiliary switch<br />

(AX) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

accessories Shunt trip<br />

(SHT) –<br />

–<br />

–<br />

–<br />

–<br />

–<br />

(option) ✽2<br />

Undervoltage trip (UVT)<br />

Non-synchronous closing (UVT-N) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Synchronous closing (UVT-S) –<br />

–<br />

–<br />

–<br />

–<br />

●<br />

Insulation switch<br />

(MG) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Built-in Earth-leakage trip alarm<br />

(EAL) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

accessories<br />

(option)<br />

Test button module<br />

Pre-alarm-contact output<br />

Cylinder key lock Available soon<br />

(TBM)<br />

(PAL)<br />

–<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

–<br />

●<br />

Accessorie’s with Lead-wire terminal block<br />

(SLT) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

connection (option) with Flying leads<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Enclosure<br />

Dustproof<br />

(S) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

( I ) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Waterproof<br />

(W) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Electrical operation device<br />

(MD) –<br />

–<br />

–<br />

–<br />

–<br />

●<br />

Mechanical interlock<br />

(MI) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Handle lock device Handle lock<br />

(HL) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

(HL-S) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Lock cover<br />

(LC) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

External<br />

(V) –<br />

●<br />

●<br />

●<br />

accessories External Door mounting<br />

●<br />

●<br />

(S) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

(option) operating<br />

handle<br />

(R) –<br />

–<br />

–<br />

–<br />

–<br />

●<br />

Mounted on breaker<br />

(F) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Insulating Between phase<br />

(BA-F) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

barrier To ground<br />

(BA-G) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Large<br />

(TC-L) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Small<br />

(TC-S) ●<br />

●<br />

●<br />

●<br />

●<br />

Terminal<br />

●<br />

cover<br />

Transparent<br />

(TTC) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

for rear connection<br />

(BTC) ●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

for plug-in<br />

(PTC) –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Automatic tripping device<br />

Hydraulicmagnetimagnetimagnetimagnetimagnetimagnetic<br />

Hydraulic-<br />

Hydraulic-<br />

Hydraulic-<br />

Hydraulic-<br />

Thermal-<br />

Trip button<br />

CE marking<br />

✽7<br />

Equipped ✽5<br />

–<br />

Equipped<br />

<br />

Equipped<br />

<br />

Equipped<br />

<br />

Equipped<br />

<br />

Equipped<br />

<br />

Note ✽1: 125A rated current is 3p only.<br />

✽2: Cassette-type aaccessories are not acceptable for NV30-CS.<br />

✽3: Standard type is thus SLT equipped.<br />

✽4: In case of ampere rating 15A and 16A, time-delay type is not available.<br />

✽5: Included in AL (type) only.<br />

✽6: Rated operational voltage of time-delay type is for 200-440V.<br />

✽7: Specify if for CE marking. In case of the CE marking article of 250A Frame or less, outside sizes differ.<br />

Rated operational voltage Available voltage range<br />

100 - 230V<br />

80~253V<br />

100 - 440V<br />

80~484V<br />

200 - 440V 160~484V<br />

21


S series<br />

125<br />

H series<br />

125<br />

U series<br />

125<br />

C series<br />

250<br />

S series<br />

250<br />

H series<br />

250<br />

U series<br />

250<br />

NV125-SW<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

– ● –<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

● ✽3<br />

● ✽3<br />

● ✽3<br />

● ✽3<br />

●<br />

●<br />

●<br />

● ✽3<br />

● ✽3<br />

● ✽3<br />

● ✽3<br />

● ✽3<br />

– – –<br />

–<br />

– ● ✽3<br />

–<br />

● ✽3<br />

●<br />

●<br />

– – – –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

– ● –<br />

● – ● –<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

NV125-HW<br />

✽4 (15) 16 20 (30) 32 40 50 ✽4 (15) 16 20 (30) 32 40 50<br />

(60) 63 (75) 80 100 125 ✽1<br />

40<br />

(60) 63 (75) 80 100<br />

40<br />

3<br />

100–440<br />

4<br />

200–440<br />

3<br />

100–440<br />

4<br />

200–440<br />

Multi-voltage type Multi-voltage type Multi-voltage type Multi-voltage type<br />

30,100 •200 •500 30,100 •200 •500<br />

Selectable<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

Selectable<br />

0.45 •1.0 •2.0<br />

0.45 •1.0 •2.0<br />

Selectable<br />

Selectable<br />

(0.1•0.5 •1.0)<br />

Button<br />

(0.1•0.5 •1.0)<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

25,000<br />

20,000<br />

10,000<br />

50/25<br />

50/25<br />

100/50<br />

25,000<br />

20,000<br />

10,000<br />

90 120 90 120<br />

130<br />

68<br />

90<br />

130<br />

68<br />

90<br />

1.1 1.4 1.1 1.4<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

NV125-RW<br />

✽4 (15) 16 20 (30) 32 40 50<br />

(60) 63 (75) 80 100<br />

40<br />

3<br />

100–440<br />

Multi-voltage type<br />

(30) 100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1 •0.5 •1.0)<br />

Button<br />

125/125<br />

125/125<br />

125/125<br />

25,000<br />

20,000<br />

10,000<br />

90<br />

191<br />

68<br />

90<br />

1.8<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Thermalmagnetic<br />

NV250-CW<br />

125 150 175<br />

200 225 250<br />

40<br />

3<br />

100–440<br />

Multi-voltage type<br />

30,100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1 •0.5 •1.0)<br />

Button<br />

15/8<br />

18/9<br />

35/18<br />

8,000<br />

4,000<br />

4,000<br />

105<br />

165<br />

68<br />

92<br />

1.7<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

● ✽3<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Thermalmagnetic<br />

NV250-SW<br />

125 150 175 125 150 175<br />

200 225 250 200 225<br />

40<br />

3 4<br />

100–440 200–440<br />

Multi-voltage type Multi-voltage type<br />

(30) 100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1 •0.5 •1.0)<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

12,000<br />

4,000<br />

4,000<br />

105 140<br />

165<br />

68<br />

92<br />

1.7 2.1<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

NV250-SEW<br />

125–225<br />

Adjustable<br />

40<br />

3 4<br />

100–440<br />

Multi-voltage type<br />

(30) 100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1 •0.5 •1.0)<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

12,000<br />

4,000<br />

4,000<br />

105 140<br />

165<br />

68<br />

92<br />

●<br />

–<br />

–<br />

NV250-HW<br />

125 150 175<br />

200 225<br />

40<br />

3 4<br />

100–440 200–440<br />

Multi-voltage type Multi-voltage type<br />

(30) 100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1 •0.5 •1.0)<br />

Button<br />

50/13<br />

50/13<br />

100/25<br />

12,000<br />

4,000<br />

4,000<br />

105 140<br />

165<br />

68<br />

92<br />

1.7 2.1<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

–<br />

NV250-HEW<br />

125–225<br />

Adjustable<br />

40<br />

3 4<br />

100–440<br />

Multi-voltage type<br />

(30) 100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1 •0.5 •1.0)<br />

Button<br />

50/13<br />

50/13<br />

100/25<br />

12,000<br />

4,000<br />

4,000<br />

105 140<br />

165<br />

68<br />

92<br />

1.8 2.3<br />

●<br />

●<br />

–<br />

●<br />

Thermalmagnetic<br />

Equipped<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

Thermalmagnetimagnetimagnetic<br />

Thermal-<br />

Electronic<br />

Thermal-<br />

Electronic<br />

Equipped<br />

Equipped Equipped<br />

Equipped<br />

Equipped<br />

Equipped<br />

Equipped<br />

<br />

<br />

– –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

1.8 2.3<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

NV250-RW<br />

125 150 175<br />

200 225<br />

40<br />

3<br />

100–440<br />

Multi-voltage type<br />

(30) 100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1 •0.5 •1.0)<br />

Button<br />

125/125<br />

125/125<br />

125/125<br />

12,000<br />

4,000<br />

4,000<br />

105<br />

240<br />

68<br />

92<br />

3.5<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

● ✽3<br />

● ✽3<br />

–<br />

–<br />

●<br />

●<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Thermalmagnetic<br />

Equipped<br />

<br />

2<br />

22


2. Detailed Specifications<br />

Earth-Leakage Circuit Breakers<br />

Series<br />

Frame size<br />

C series<br />

400<br />

S series<br />

400<br />

H series<br />

400<br />

Photo<br />

Type name<br />

NV400-CW<br />

NV400-SW<br />

NV400-SEW<br />

NV400-HEW<br />

Rated current In (Amp.)<br />

Rated ambient temperature (°C)<br />

Number of poles<br />

Rated operational voltage Ue (AC V)<br />

High-speed type<br />

Time-delay type<br />

Max. operating time at 2I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Earth-leakage indication system<br />

AC440V<br />

Rated short-circuit breaking capacity (kA)<br />

IEC60947-2 (Icu/Ics)<br />

AC400V<br />

AC230V<br />

Suitability for isolation<br />

a ca c<br />

a<br />

Overall dimensions (mm)<br />

b<br />

b<br />

c<br />

ca<br />

Mass of front-connection type (kg)<br />

Screw terminal<br />

Front Solderless (box) terminal (SL)<br />

Fixed<br />

Installation and<br />

Busbar terminal<br />

connections<br />

Rear<br />

(B)<br />

Plug-in<br />

Rear<br />

(PM)<br />

Rear/front IP20<br />

(PM-IP)<br />

Alarm switch<br />

(AL)<br />

Cassette-type Auxiliary switch<br />

(AX)<br />

accessories Shunt trip<br />

(SHT)<br />

(option)<br />

Undervoltage trip (UVT)<br />

Non-synchronous closing (UVT-N)<br />

Synchronous closing (UVT-S)<br />

Insulation switch<br />

(MG)<br />

Earth-leakage trip alarm<br />

(EAL)<br />

Built-in Test button module<br />

(TBM)<br />

accessories<br />

Pre-alarm-contact output<br />

(PAL)<br />

(option)<br />

Overcurrent trip alarm ✽3<br />

(OAL)<br />

Accessorie’s with Lead-wire terminal block<br />

(SLT)<br />

connection (option) with Flying leads<br />

Enclosure<br />

Dustproof<br />

(S)<br />

( I )<br />

Waterproof<br />

(W)<br />

Electrical operation device<br />

(MD)<br />

Mechanical interlock<br />

(MI)<br />

Handle lock device Handle lock<br />

(HL)<br />

(HL-S)<br />

Lock cover<br />

(LC)<br />

External<br />

(V)<br />

accessories External Door mounting<br />

(S)<br />

(option) operating<br />

handle<br />

(R)<br />

Mounted on breaker<br />

(F)<br />

Insulating Between phase<br />

(BA-F)<br />

barrier To ground<br />

(BA-G)<br />

Large<br />

(TC-L)<br />

Small<br />

(TC-S)<br />

Terminal<br />

cover<br />

Transparent<br />

(TTC)<br />

for rear connection<br />

(BTC)<br />

for plug-in<br />

(PTC)<br />

Automatic tripping device<br />

Trip button<br />

CE marking<br />

✽4<br />

✽3<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Note ✽1: In case of solderless terminal, interrupting capacity reduces: ( / )<br />

✽2: Solid state relay output is option. Please specify if order output is necessary. (Standard type is thus SLT equipped.)<br />

✽3: Rated operational voltage of time-delay type is for 200-440V.<br />

✽4: Specify if for CE marking.<br />

250 300 350 400<br />

250 300 350 400<br />

200~400 adjustable<br />

200~400 adjustable<br />

40<br />

40<br />

40<br />

40<br />

3<br />

3<br />

3 4 3 4<br />

100–440<br />

100–440<br />

100–440<br />

100–440<br />

Multi-voltage type<br />

Multi-voltage type<br />

Multi-voltage type<br />

Multi-voltage type<br />

(30) 100 •200 •500<br />

(30) 100 •200 •500<br />

(30) 100 •200 •500<br />

(30) 100 •200 •500<br />

Selectable<br />

Selectable<br />

Selectable<br />

Selectable<br />

0.04<br />

0.04<br />

0.04<br />

0.04<br />

100 •200 •500<br />

100 •200 •500<br />

100 •200 •500<br />

100 •200 •500<br />

Selectable<br />

Selectable<br />

Selectable<br />

Selectable<br />

0.45 •1.0 •2.0<br />

0.45 •1.0 •2.0<br />

0.45 •1.0 •2.0<br />

0.45 •1.0 •2.0<br />

Selectable<br />

Selectable<br />

Selectable<br />

Selectable<br />

(0.1•0.5 •1.0)<br />

(0.1•0.5 •1.0)<br />

(0.1•0.5 •1.0)<br />

(0.1•0.5 •1.0)<br />

Button<br />

Button<br />

Button<br />

Button<br />

25/13<br />

42/42(36/36) ✽1<br />

42/42(36/36) ✽1<br />

65/65<br />

36/18<br />

45/45(36/36) ✽1<br />

50/50(36/36) ✽1<br />

70/70<br />

50/25<br />

85/85(65/65) ✽1<br />

85/85(65/65) ✽1<br />

100/100<br />

●<br />

● ● ●<br />

140<br />

140<br />

140 185<br />

140 185<br />

257<br />

257<br />

257<br />

257<br />

103<br />

103<br />

103<br />

103<br />

134<br />

155<br />

155<br />

155<br />

6.1<br />

6.4<br />

7.1 8.9<br />

7.1 8.9<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

● ✽2<br />

● ✽2<br />

–<br />

–<br />

– –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Thermalmagnetimagnetic<br />

Thermal-<br />

Electronic<br />

Electronic<br />

Equipped<br />

Equipped<br />

Equipped<br />

Equipped<br />

<br />

<br />

Rated operational voltage<br />

100 - 440V<br />

200 - 440V<br />

Available voltage range<br />

80~484V<br />

160~484V<br />

23


H series<br />

400<br />

C series<br />

630<br />

S series<br />

630<br />

H series<br />

630<br />

S series<br />

800<br />

H series<br />

800<br />

NV400-REW<br />

NV630-CW<br />

NV630-SW<br />

NV630-SEW<br />

NV630-HEW<br />

NV800-SEW<br />

NV800-HEW<br />

2<br />

200~400 adjustable<br />

40<br />

500 600 630<br />

40<br />

500 600 630<br />

40<br />

300~630 adjustable<br />

40<br />

300~630 adjustable<br />

40<br />

400~800 adjustable<br />

40<br />

400~800 adjustable<br />

40<br />

3<br />

3<br />

3<br />

3 4<br />

3<br />

3<br />

3<br />

100–440<br />

Multi-voltage type<br />

100 •200 •500<br />

Selectable<br />

0.04<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

100–440<br />

Multi-voltage type<br />

100 •200 •500<br />

Selectable<br />

–<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

100–440<br />

Multi-voltage type<br />

100 •200 •500<br />

Selectable<br />

–<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

100–440<br />

Multi-voltage type<br />

100 •200 •500<br />

Selectable<br />

–<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

100–440<br />

Multi-voltage type<br />

100 •200 •500<br />

Selectable<br />

–<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

100–440<br />

Multi-voltage type<br />

100 •200 •500<br />

Selectable<br />

–<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

100–440<br />

Multi-voltage type<br />

100 •200 •500<br />

Selectable<br />

–<br />

100 •200 •500<br />

Selectable<br />

0.45 •1.0 •2.0<br />

Selectable<br />

(0.1•0.5 •1.0)<br />

Button<br />

(0.1•0.5 •1.0)<br />

Button<br />

0.1•0.5 •1.0<br />

Button<br />

(0.1•0.5 •1.0)<br />

Button<br />

(0.1•0.5 •1.0)<br />

Button<br />

0.1•0.5 •1.0<br />

Button<br />

(0.1•0.5 •1.0)<br />

Button<br />

125/63<br />

125/63<br />

150/75<br />

●<br />

36/18<br />

36/18<br />

50/25<br />

●<br />

42/42<br />

50/50<br />

85/85<br />

●<br />

42/42<br />

50/50<br />

85/85<br />

●<br />

65/65<br />

70/70<br />

100/100<br />

●<br />

42/42<br />

50/50<br />

85/85<br />

●<br />

65/65<br />

70/70<br />

100/100<br />

●<br />

140<br />

140<br />

140<br />

140 185<br />

140<br />

210<br />

210<br />

257<br />

103<br />

155<br />

257<br />

103<br />

155<br />

257<br />

103<br />

155<br />

257<br />

103<br />

155<br />

257<br />

103<br />

155<br />

275<br />

103<br />

155<br />

275<br />

103<br />

155<br />

7.1<br />

6.9<br />

6.9<br />

7.1 8.9<br />

7.1<br />

15.3<br />

15.3<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

● ✽2<br />

–<br />

–<br />

● ✽2<br />

● ✽2<br />

● ✽2<br />

● ✽2<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

–<br />

–<br />

●<br />

●<br />

●<br />

–<br />

–<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

–<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Electronic<br />

Thermalmagnetimagnetic<br />

Thermal-<br />

Electronic<br />

Electronic<br />

Electronic<br />

Electronic<br />

Equipped<br />

Equipped<br />

Equipped<br />

Equipped<br />

Equipped<br />

Equipped<br />

Equipped<br />

<br />

<br />

24


2. Detailed Specifications<br />

Motor-Protection Breakers<br />

Frame A 30<br />

50 100 225<br />

Type name MB30-CS<br />

MB30-SW<br />

MB50-CW MB50-SW MB100-SW MB225-SW<br />

200/220V 400/440V<br />

200/220V 400/440V<br />

A<br />

A<br />

kW kW<br />

kW kW<br />

200/220V 400/440V<br />

200/220V 400/440V<br />

200/220V 400/440V<br />

200/220V 400/440V<br />

A<br />

A<br />

A<br />

A<br />

32 7.5 15 32 7.5 15<br />

kW kW<br />

kW kW<br />

kW kW<br />

kW kW<br />

25 5.5 11 25 5.5 11<br />

100 – 55<br />

45 11 22 7.1 1.5 –<br />

225 55 110<br />

16 3.7 7.5 16 3.7 7.5<br />

90 22 45<br />

Rated current In (Amp.)<br />

(12) – 5.5 12 – 5.5 40 – 18.5 5 – 2.2<br />

200 – –<br />

10 2.2 – 10 2.2 –<br />

71 18.5 37<br />

Rated motor capacity: kW<br />

(8) – 3.7 8 – 3.7<br />

32 7.5 15 4 0.75 1.5 63 15 30<br />

175 45 90<br />

7.1 1.5 – 7.1 1.5 – 25 5.5 11 2.5 0.4 – 45 11 22 150 37 75<br />

Reference ambient temperature 40°C (5) – 2.2 5 – 2.2<br />

4 0.75 1.5 4 0.75 1.5<br />

16 3.7 7.5 2 – 0.75 (40) – 19 125 30 –<br />

(45°C for marine applications)<br />

2.5 0.4 – 2.5 0.4 –<br />

32 7.5 15<br />

12 – 5.5 1.4 0.2 –<br />

(2) – 0.75 2 – 0.75<br />

(25) 5.5 11<br />

1.4 0.2 – 1.4 0.2 –<br />

10 2.2 – 1.2 – 0.4<br />

(16) 3.7 7.5<br />

(1.2) – 0.4 1.2 – 0.4<br />

(0.8) – – 0.8 – –<br />

8 – 3.7 0.8 – – (12.5) – 5.5<br />

Number of poles<br />

2 (for single phase) 3<br />

3<br />

3 3 3 3<br />

Rated insulation voltage Ui (V)<br />

500<br />

500<br />

500 500 500 500<br />

440V 1.5/1.5 (415V)<br />

2.5/1<br />

2.5/1 7.5/4 25/13<br />

25/13<br />

lEC 60947-2<br />

(lcu/lcs)<br />

AC 400V 1.5/1.5 (380V)<br />

5/2<br />

5/2 7.5/4 30/15<br />

30/15<br />

230V 2.5/2 (240V)<br />

7.5/4<br />

7.5/4 15/8 50/25 50/25<br />

a ca c<br />

a 45 67.5<br />

75<br />

75 75 90 105<br />

b 96<br />

130<br />

130 130 130 165<br />

b<br />

c 52<br />

68<br />

68 68 68 68<br />

ca 67<br />

90<br />

90 90 90 92<br />

Mass of front-connection type (kg) 0.25 0.35<br />

0.55<br />

0.55 0.55 0.95 1.5<br />

Rated shortcircuit<br />

breaking<br />

capacities (kA)<br />

Overall<br />

dimensions<br />

(mm)<br />

Connection<br />

method<br />

Front connection<br />

(F)<br />

● Crimp contact<br />

● Crimp contact<br />

● Crimp contact ● Crimp contact ● Crimp contact ● Crimp contact<br />

Rear connection (B) ● Round stud (assembled in) ● Round stud ● Round stud ● Round stud ● Flat stud ● Flat stud<br />

Plug-in<br />

(PM)<br />

–<br />

●<br />

● ● ● ●<br />

Remark: The products of which rated current is parenthesized will be produced when an order is placed.<br />

25


2. Detailed Specifications<br />

UL Listed Products<br />

Frame A<br />

Type name<br />

100 225 50 100 150 250<br />

NF100-CWU NF225-CWU NF50-SWU NF100-SWU NF-SFW NF-SJW NF-HJW<br />

400<br />

NF-SKW<br />

600<br />

NF-SLW<br />

Photo<br />

2<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

50 60 75<br />

100<br />

125 150 175<br />

200 225<br />

(3) 5 10 15<br />

20 30 40 50<br />

15 20 30<br />

40 50 60<br />

75 100<br />

15 20 30 40 50<br />

60 70 80 90 100<br />

110 125 150<br />

(125) (150)<br />

175 200<br />

225 250<br />

125 150 175<br />

200 225 250<br />

250 300<br />

350 400<br />

500 600<br />

Number of poles<br />

2 3 3 2 3 2 3 3 3 3<br />

3<br />

3<br />

Rated voltage (V AC) 240 240 240 480Y/277 600Y/347 600Y/347 600Y/347<br />

600Y/347<br />

600Y/347<br />

600Y/347V – – – – 14 14 18<br />

20<br />

20<br />

Rated short-circuit breaking capacities (kA)<br />

UL 489<br />

JIS C 8201-2<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

480V – – – – 35 35 50<br />

480Y/277V – – – 22 35 35 50<br />

240V 10 35 14 35 65 65 100<br />

Rated insulation voltage Ui (V) 600 600 600 690 690 690 690<br />

690V – – – 8/4 8/8 8/8 15/15<br />

500V 7.5/4 10/5 7.5/4 18/9 30/30 30/30 36/36<br />

440V 10/5 15/8 7.5/4 25/13 36/36 36/36 50/50<br />

AC 415V 10/5 18/9 7.5/4 30/15 36/36 36/36 50/50<br />

400V 10/5 18/9 7.5/4 30/15 36/36 36/36 50/50<br />

380V 10/5 18/9 7.5/4 30/15 36/36 36/36 50/50<br />

35<br />

–<br />

65<br />

690<br />

10/10 (5/5) (✽5)<br />

30/30 (25/25) (✽5)<br />

42/42 (36/36) (✽5)<br />

45/45 (36/36) (✽5)<br />

45/45 (36/36) (✽5)<br />

50/50 (42/42) (✽5)<br />

35<br />

–<br />

85<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

45/45<br />

45/45<br />

50/50<br />

230V 30/15 35/18 15/8 50/25 85/85 85/85 100/100<br />

85/85 (65/65) (✽5)<br />

85/85<br />

DC 250V ✽3 7.5/4 10/5 – 15/8 20/20 20/20 20/20<br />

–<br />

–<br />

Compatible to AC/DC ✽1 ● ● – ● ● ● ●<br />

–<br />

–<br />

Suitability for isolation<br />

● ● ● ● ● ● ●<br />

●<br />

●<br />

Reverse connection<br />

● ● ● ● ● ● ●<br />

●<br />

●<br />

Overall<br />

dimensions<br />

(mm)<br />

a<br />

b<br />

ca c<br />

a 60 90 105 50 75 60 90 105 105 105<br />

b 150 165 150 150 185 185 185<br />

c 68 68 68 68 86 86 86<br />

140<br />

257<br />

103<br />

210<br />

275<br />

103<br />

ca 90 92 90 90 110 110 110<br />

155<br />

155<br />

Mass of front-connection type (kg)<br />

0.7 0.95<br />

1.5<br />

0.45<br />

0.6 0.7 0.95 2.0 2.0 2.0<br />

5.7<br />

9.6<br />

Connection<br />

method<br />

Accessories ✽2<br />

(option)<br />

Front<br />

connection<br />

Screw terminal<br />

Solderless<br />

terminal (box)<br />

Busbar terminal<br />

Alarm switch<br />

Auxiliary switch<br />

Shunt trip<br />

Under-voltage trip<br />

Vertical lead-wire terminal unit<br />

Mechanical interlock<br />

(F) ● ● ● ● ● ● ●<br />

(SL) ● – – ● ● ● ●<br />

●<br />

●<br />

(BAR) ● ● ● ● ● ● ● ● ●<br />

(AL) ● ● ● ● ● ● ●<br />

●<br />

●<br />

(AX) ● ● ● ● ● ● ●<br />

●<br />

●<br />

(SHT) ● ● ● ● ● ● ●<br />

●<br />

●<br />

(UVT) ● ● ● ● ● ● ●<br />

●<br />

●<br />

(SLT) ● ● ● ● ● ● ●<br />

●<br />

●<br />

(MI) ● ● ● ● ● ● ●<br />

●<br />

●<br />

–<br />

–<br />

External accessories ✽2<br />

(option)<br />

Handle lock device<br />

Operating handle<br />

Insulating barrier<br />

Terminal Large<br />

cover<br />

Small<br />

(HL) ● ● ● ● ● ● ●<br />

F ● ● ● ● ● ● ●<br />

S ● ● ● ● ● ● ●<br />

V – ● ● – ● – ● ● ● ●<br />

(IB) ● ● ● ● ● ● ●<br />

(TC-L) ● ● ● ● ● ● ●<br />

(TC-S) – – ✽4 – – – – –<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

●<br />

●<br />

●<br />

●<br />

●<br />

●<br />

–<br />

IEC 35mm rail fixture<br />

– – Supplied standardly – – – –<br />

–<br />

–<br />

Automatic tripping device<br />

Thermalmagnetic<br />

Thermalmagnetic<br />

Hydraulicmagnetic<br />

Thermalmagnetic<br />

Thermalmagnetic<br />

Thermalmagnetic<br />

adjustable magnetic<br />

Thermal-<br />

adjustable<br />

Thermalmagnetic<br />

Thermalmagnetic<br />

adjustable<br />

Trip button<br />

Equipped Equipped Equipped Equipped Equipped Equipped Equipped<br />

Equipped<br />

Equipped<br />

TÜV type approval<br />

●<br />

●<br />

● ● ● ● ●<br />

●<br />

●<br />

Notes: ✽1 The trip action characteristics differ between AC and DC for products that are compatible to both AC and DC.<br />

✽2 Specifications for products with a CE mark differ from those for general-purpose products. Details will<br />

be available upon request.<br />

✽3 Use two poles among the three poles in the case of three-pole products. In addition, wiring as shown to the<br />

right allows the models of NF100-CWU, NF100-SWU and NF225-CWU to be used for up to 400 V DC and<br />

the models of NF-SFW, NF-SJW, and NF-HJW to be used for up to 500 V DC.<br />

✽4 The standard configuration contains a protection cover and adopts the IP20 (finger protection) structure.<br />

✽5 In case of solderless terminal, interrupting capacity reduces: (/).<br />

Remark: The products of which rated current is parenthesized will be produced when an order is placed.<br />

The operating characteristics of breakers are different between AC and DC (JIS and IEC only).<br />

Line<br />

3-pole<br />

Load<br />

26


2. Detailed Specifications<br />

Miniature Circuit Breakers<br />

Type<br />

BH<br />

BH-P<br />

Frame (A)<br />

70<br />

100<br />

100<br />

70<br />

100<br />

100<br />

Photo<br />

Number<br />

of poles<br />

1 2 3 1 2 3<br />

Rated current (A)<br />

a t ambient temperature 40° C<br />

70 70,100<br />

70,100<br />

70<br />

70,100<br />

70,100<br />

Rated voltage (V)<br />

AC<br />

230/400<br />

DC<br />

125<br />

230/400<br />

125<br />

Breaking capacity<br />

(kA) sym.<br />

IEC 60898<br />

AC230/400V<br />

AC400V<br />

3<br />

—<br />

—<br />

3<br />

3<br />

—<br />

—<br />

3<br />

— DC125V<br />

1<br />

1<br />

Type of instantaneous operation<br />

Type C (5 In


Type<br />

BH-S M3<br />

BH-S M6<br />

Photo<br />

2<br />

Number<br />

of poles<br />

1 2 3 1 2 3<br />

Rated current (A)<br />

at ambient temperature 40°C<br />

5,10,15,20,(25),<br />

30,40,50,60<br />

10,15,20,(25),<br />

30,40,50,60<br />

15,20,(25),<br />

30,40,50,60<br />

5,10,15,20,(25),<br />

30,40,50,60<br />

10,15,20,(25),<br />

30,40,50,60<br />

15,20,(25),<br />

30,40,50,60<br />

Rated voltage (V)<br />

AC<br />

DC<br />

230/400<br />

400 400 230/400 400 400<br />

— 125<br />

— — 125<br />

—<br />

Breaking capacity<br />

(kA) sym.<br />

IEC 60898<br />

AC230/400V<br />

AC400V<br />

3<br />

—<br />

— 6<br />

—<br />

3<br />

—<br />

6<br />

—<br />

DC125V<br />

—<br />

1<br />

— —<br />

1<br />

—<br />

Type of instantaneous operation<br />

Types B,C,D ✳2<br />

a 25<br />

50<br />

75<br />

25<br />

50<br />

75<br />

Dimensions<br />

(mm)<br />

a<br />

b<br />

ca<br />

c<br />

b 95<br />

95<br />

c 57.<br />

5<br />

57. 5<br />

ca<br />

76<br />

76<br />

Mass (kg) 0.15<br />

0.32<br />

0.50<br />

0.15<br />

0.32<br />

0.50<br />

Clamp terminal<br />

Connection ✳1<br />

Automatic<br />

tripping device<br />

Optional<br />

accessories<br />

Terminal cover<br />

Mounting plate<br />

Handle lock<br />

Thermal, magnetic<br />

●<br />

●<br />

●<br />

L ock cover<br />

—<br />

A pproved by<br />

—<br />

✳ 1. If required Solderless terminal can be supplied (Line and Load side)<br />

✳ 2. Type B (3 In


2. Detailed Specifications<br />

Miniature Circuit Breakers<br />

Type<br />

BH-PS M3 BH-PS M9<br />

Photo<br />

Number<br />

of poles<br />

1 2 3 1 2 3<br />

Rated current (A)<br />

at ambient temperature 40°C<br />

10,15,20,<br />

30,40,50,60<br />

10,15,20,<br />

30,40,50,60<br />

15,20,<br />

30,40,50,60<br />

6,10,16,20,(25),<br />

32,40,50,60<br />

10,16,20,(25),<br />

32,40,50,60<br />

10,16,20,(25),<br />

32,40,50,60<br />

Rated voltage (V)<br />

AC<br />

DC<br />

230/400<br />

400 400 230/400 400 400<br />

— 125<br />

— —<br />

Breaking capacity<br />

(kA) sym.<br />

IEC 60898<br />

AC230/400V<br />

AC400V<br />

3<br />

—<br />

—<br />

3<br />

9<br />

—<br />

—<br />

9<br />

—<br />

DC125V<br />

—<br />

1<br />

—<br />

—<br />

Type of instantaneous operation<br />

Types B,C,D ✳<br />

a 25<br />

50<br />

75<br />

25<br />

50<br />

75<br />

Dimensions<br />

(mm)<br />

a<br />

b<br />

ca<br />

c<br />

b 81.5<br />

c 60.5<br />

81.5<br />

60.5<br />

ca<br />

79<br />

79<br />

Mass (kg) 0.15<br />

0.32<br />

0.50<br />

0.15<br />

0.32<br />

0.50<br />

Plug-in (line)<br />

Clam p (load)<br />

Connection<br />

Automatic<br />

tripping device<br />

Optional<br />

accessories<br />

Terminal cover<br />

Terminal base<br />

Lock cover<br />

Handle lock<br />

Thermal, magnetic<br />

—<br />

●<br />

—<br />

●<br />

A pproved by<br />

— LR<br />

✳ Type B (3 In


MCB BH-D6 (IEC 60898) BH-DN (IEC 60898)<br />

Photo<br />

2<br />

Number<br />

of poles<br />

1 2 3<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

6,10,13,16,20,25,<br />

32,40,50,63<br />

6,10,13,16,20,25,<br />

32,40,50,63<br />

6,10,13,16,20,25,<br />

32,40,50,63<br />

4 (3+N) 2 (1+N)<br />

610,13,16,20,25,<br />

, 6,10,13,16,20<br />

32,40,50,63<br />

25,32,40<br />

2 (1+N)<br />

6,10,16,20<br />

Rated<br />

voltage (VAC)<br />

230/400<br />

400<br />

400<br />

400<br />

Breaking<br />

capacity (kA) sym. (IEC60898)<br />

6<br />

Tripping<br />

characteristics<br />

Dimensions<br />

(mm)<br />

a<br />

b<br />

ca<br />

c<br />

Type B, C, D ✳<br />

a 18 36<br />

54<br />

b 87<br />

c 44<br />

ca<br />

70<br />

Mass (kg) 0.<br />

15<br />

0.30<br />

0.45<br />

Connection<br />

Automatic<br />

tripping device<br />

, Type D (10In , 20In)<br />

Solderless<br />

Thermal,magneti c<br />

Optional accessories Insulating barrier — 1 pc<br />

2 pcs<br />

RCCB BV-D (IEC 61008)<br />

72<br />

0.6<br />

3 pcs<br />

RCBO<br />

230<br />

Type B, C ✳<br />

36<br />

0.30<br />

230<br />

4.5<br />

Type C<br />

18<br />

88<br />

44<br />

70<br />

0.12<br />

1 pc —<br />

BV-DN (IEC 61009)<br />

Photo<br />

Photo<br />

Number<br />

of poles<br />

a<br />

b<br />

ca<br />

c<br />

2(1+N)<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

25, 40, 63<br />

Rated voltage (VAC )<br />

230 230/400<br />

Rated current sensitivity I∆n (mA)<br />

30, 300<br />

Max. operating time (s) at 5I∆ 0.04<br />

Pulsating current sensitivity<br />

Rated conditional short-circuit current (kA)<br />

Type AC<br />

6<br />

Dimensions<br />

(mm)<br />

a 36<br />

b 85<br />

c 44<br />

ca<br />

70<br />

Mass (kg) 0.2<br />

C onnection<br />

solderless<br />

4(3+N)<br />

72<br />

0.35<br />

Number of poles<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

Rated voltage (VAC)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time (s) at5I∆n<br />

Pulsating current sensitivity<br />

Breaking capacity (kA) sym. (IEC61009)<br />

Tripping characteristics<br />

DImension<br />

(mm)<br />

Mass (kg)<br />

Connection<br />

Automatic tripping device<br />

Option<br />

a<br />

b<br />

ca<br />

c<br />

a<br />

b<br />

c<br />

ca<br />

2 (1+N)<br />

6,10,16,20,25,32<br />

230<br />

30,100,300<br />

0.04<br />

Type AC<br />

4.5<br />

Type C ✳<br />

36<br />

88<br />

44<br />

70<br />

0.19<br />

Solderless<br />

Thermal,magnetic<br />

Over voltage release (280V±5%)<br />

Isolating switch KB-D (IEC 60947-3)<br />

Photo<br />

Number<br />

of poles<br />

1 2 3<br />

Utilization category<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

a<br />

b<br />

ca<br />

c<br />

32, 63, 80<br />

Rated<br />

voltage (VAC)<br />

230 400<br />

Short time withstand current (A)<br />

20 ✕ In, 1s<br />

Short-circuit making capacity (A)<br />

20 ✕ In<br />

Dimensions<br />

(mm)<br />

a 18<br />

36<br />

54<br />

b 87<br />

c 44<br />

ca<br />

70<br />

Mass (kg) 0.09 0.18 0.27<br />

Connection<br />

Optional accessories<br />

Insulating barrier<br />

AC22A class<br />

Solderless<br />

— 1 pc<br />

2 pcs<br />

4 (3+N)<br />

72<br />

0.36<br />

3 pcs<br />

30


2. Detailed Specifications<br />

ELRs and ZCTs<br />

Earth-Leakage relays<br />

Type<br />

Model name of ZCT combined<br />

(Note 5)<br />

Hole diameter mm<br />

15<br />

30<br />

40<br />

60<br />

80<br />

100<br />

Electrical self-hold type<br />

NV-ZBA<br />

ZT15B<br />

ZT30B<br />

ZT40B<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

ZT60B<br />

ZT80B<br />

ZT100B<br />

Mechanical self-hold type<br />

NV-ZSA<br />

ZT15B<br />

ZT30B<br />

ZT40B<br />

–<br />

–<br />

–<br />

Interchangeable leakage relay (Note 1)<br />

–<br />

–<br />

–<br />

ZT60B<br />

ZT80B<br />

ZT100B<br />

Harmonic surge ready<br />

Electrical self-hold type<br />

NV-ZHA<br />

ZT15B<br />

ZT30B<br />

ZT40B<br />

ZT60B<br />

ZT80B<br />

ZT100B<br />

Harmonic surge ready<br />

Mechanical self-hold type<br />

NV-ZLA<br />

ZT15B<br />

ZT30B<br />

ZT40B<br />

ZT60B<br />

ZT80B<br />

ZT100B<br />

Photo<br />

Control voltage AC V<br />

JIS<br />

UL/JIS<br />

UL/CE<br />

Built-in contact<br />

High speed<br />

type<br />

Delay<br />

type<br />

Delay type<br />

JIS<br />

UL/JIS (Note 2)<br />

UL/CE (Note 3)<br />

Rated sensitivity current mA<br />

Max. operating time s<br />

Rated sensitivity current mA<br />

Operating time s (Note 4)<br />

Inertial non-operating time s or longer than s<br />

Rated sensitivity current mA<br />

Max. operating time s<br />

Rated sensitivity current mA<br />

Max. operating time s (Note 4)<br />

Inertial non-operating time s or longer than s<br />

Rated sensitivity current mA<br />

Max. operating time s at5I∆n<br />

Rated sensitivity current mA<br />

Max. operating time s at2I∆n (Note 4)<br />

Inertial non-operating time s at2I∆n<br />

Earth-leakage indication<br />

Resetting method<br />

Configuration<br />

Continuous current capacity A<br />

Contact capacity A<br />

Connection<br />

Front<br />

Rear<br />

Standard attachment (Front connection)<br />

Mass kg<br />

Relay<br />

External<br />

Terminal cover<br />

accessories Mounting hook for IEC 35mm rail (DIN rail) Fixture<br />

Conforming standard<br />

High<br />

speed<br />

type<br />

High speed<br />

• Delay<br />

type<br />

High<br />

speed<br />

type<br />

Phase line type<br />

Max. consumption VA<br />

US UL standard (UR certified)<br />

Canada CSA standard<br />

European CE marking<br />

120VAC<br />

240VAC<br />

24VDC<br />

120 • 240 selectable<br />

30<br />

100 • 200 • 500<br />

selectable<br />

–<br />

cosφ=1<br />

5<br />

5<br />

5<br />

100 • 200 • 500<br />

selectable<br />

0.1<br />

100 • 200 • 500 selectable<br />

0.3 • 0.8 • 1.6 selectable<br />

0.1 • 0.5 • 1.1<br />

–<br />

–<br />

Electric type (LED)<br />

Push button or control power<br />

switch off<br />

1c<br />

5<br />

Clamp terminal<br />

–<br />

0.3<br />

(TC-ZBA)<br />

(DIN-ZBA)<br />

–<br />

–<br />

–<br />

cosφ=0.4<br />

L/R=0.007<br />

2<br />

2<br />

2<br />

120VAC<br />

240VAC<br />

415VAC<br />

30VDC<br />

100VDC<br />

200VDC<br />

120 • 240 selectable<br />

240 • 415 selectable<br />

30<br />

100 • 200 • 500<br />

selectable<br />

–<br />

cosφ=1<br />

5<br />

3<br />

2<br />

4<br />

0.4<br />

0.2<br />

3φ4W, 3φ3W, 1φ3W, 1φ2W<br />

100 • 200 • 500<br />

selectable<br />

0.1<br />

100 • 200 • 500 selectable<br />

(200 • 500 • 1000 selectable)<br />

0.3 • 0.8 • 1.6 selectable<br />

0.1 • 0.5 • 1.1<br />

–<br />

–<br />

Mechanical type (button)<br />

Push button<br />

(conbined with earth-leakage<br />

indicator)<br />

1a1c<br />

5<br />

cosφ=0.4<br />

L/R=0.007<br />

3<br />

2<br />

1<br />

3<br />

0.4<br />

0.2<br />

Clamp terminal<br />

Clamp terminal<br />

Mounting screw<br />

0.4<br />

(TC-ZSA)<br />

–<br />

3<br />

Note (1) Interchargeable leakage relay can be freely combined with relay and our ZCT. However, 30mA sensitivity product<br />

(excluding NV-ZHA/ZLA) can be combined with only ZT15B, ZT30B and ZT40B.<br />

(2) Indicates control voltage of UL. These are products indicating UL, CSA and JIS together. For voltage indication in<br />

JIS, 100-200V changeover for 120-240V changeover, 200-415V changeover for 240-440V changeover, 460V for<br />

480V are described together. When ordering, specify "UL/JIS".<br />

(3) Indicates control voltage of UL. These are products indicating UL, CSA and CE together. For voltage indication in<br />

CE, 120-230V changeover for 120-240V changeover, 230-440V changeover for 240-440V selectable are described<br />

together. When ordering, specify "UL/CE".<br />

(4) When the operating time are 0.3 and 0.45 seconds, 0.8 and 1.0 seconds, and 1.6 seconds, the relay operates<br />

between 0.15 and 0.45, between 0.6 and 1.0 seconds and between 1.2 and 2.0 seconds respectively.<br />

(5) Can be combined with interchangeable ZCT with primary conductor. Refer to the next page for detail.<br />

(6) It's not UL-certified.<br />

–<br />

–<br />

–<br />

–<br />

120 • 240 selectable<br />

240 • 440 selectable<br />

–<br />

30 50<br />

0.1<br />

100 • 200 • 500 selectable<br />

0.1 • 0.45 • 1.0 selectable<br />

– • 0.1 • 0.5<br />

30 • 50 • 100 selectable<br />

0.04<br />

100 • 300 • 500 selectable<br />

300 • 500 • 1000 selectable<br />

0.45 • 1.0 selectable<br />

0.1 • 0.5<br />

Electric type (LED)<br />

Push button or control power<br />

switch off<br />

1a1c<br />

5<br />

cosφ=1<br />

cosφ=0.4<br />

120VAC<br />

240VAC<br />

24VDC<br />

5<br />

5<br />

5<br />

L/R=0.007<br />

2<br />

2<br />

2<br />

Use auxiliary relay for AC415V contact.<br />

Clamp terminal<br />

Clamp terminal<br />

0.4<br />

(TC-ZSA)(Note 6)<br />

–<br />

UL1053<br />

Recognized component<br />

(File No.E196562)<br />

LR103083(Certified No.)<br />

Declaration for conformity<br />

IEC60947-2 AnnexB<br />

EN60947-2 AnnexB<br />

Control voltage<br />

120V<br />

240V<br />

415V<br />

Control voltage<br />

120V<br />

240V<br />

440V<br />

480V<br />

–<br />

120 • 240 selectable<br />

240 • 440 selectable<br />

480<br />

120VAC<br />

240VAC<br />

480VAC<br />

30VDC<br />

Available voltage range<br />

80~126V<br />

160~252V<br />

320~484V<br />

Available voltage range<br />

80~132V<br />

160~264V<br />

304~484V<br />

368~528V<br />

–<br />

30 50<br />

0.1<br />

100 • 200 • 500 selectable<br />

0.1 • 0.45 • 1.0 selectable<br />

– • 0.1 • 0.5<br />

30 • 50 • 100 selectable<br />

0.04<br />

100 • 300 • 500 selectable<br />

300 • 500 • 1000 selectable<br />

0.45 • 1.0 selectable<br />

0.1 • 0.5<br />

Mechanical type (button)<br />

Push button<br />

(conbined with earthleakage<br />

indicator)<br />

1a1c<br />

5<br />

cosφ=1<br />

5<br />

3<br />

1<br />

3<br />

Clamp terminal<br />

Clamp terminal<br />

cosφ=0.4<br />

L/R=0.007<br />

3<br />

2<br />

1<br />

3<br />

0.4<br />

(TC-ZSA)(Note 6)<br />

–<br />

UL1053<br />

Recognized component<br />

(File No.E196562)<br />

LR103083(Certified No.)<br />

Declaration for conformity<br />

IEC60947-2 AnnexB<br />

EN60947-2 AnnexB<br />

Remark (1) Relays with rate shown in the ( ) in the space for rate<br />

are manufactured by your order.<br />

(2) CE marking is for self-statement for the purpose of<br />

interrupting NF when ground-fault occurs by combining<br />

with our NF with CE marking (voltage tripping device).<br />

(3) NV-ZBA/ZSA<br />

(4) NV-ZHA/ZLA<br />

Example of applicable circuit voltage<br />

100 • 110V • 120V<br />

200 • 220 • 240V<br />

400 • 415 • 440V<br />

Example of applicable circuit voltage<br />

100 • 110 • 120V<br />

200 • 220 • 230 • 240V<br />

380 • 400 • 415 • 440V<br />

460 • 480V<br />

31


Interchangeable ZCT<br />

Type<br />

ZT15B<br />

ZT30B<br />

Aperture diameter (mm)<br />

15<br />

30<br />

40<br />

60<br />

80<br />

100<br />

Mass (kg) 0.<br />

2<br />

0.<br />

4<br />

0.<br />

6<br />

2.<br />

0<br />

2.<br />

6<br />

3. 3<br />

Rated short time current<br />

50 (peak value)<br />

Dimensions<br />

(mm)<br />

a 48<br />

68<br />

85<br />

140<br />

160<br />

185<br />

b 52<br />

52<br />

52<br />

90<br />

90<br />

90<br />

c 70<br />

90<br />

100<br />

150<br />

169<br />

190<br />

d<br />

a<br />

e<br />

b<br />

c<br />

ZT40B<br />

ZT60B<br />

ZT80B<br />

ZT100B<br />

d 25<br />

50<br />

50<br />

100<br />

100<br />

100<br />

e 40<br />

40<br />

40<br />

70<br />

70<br />

70<br />

2<br />

ZCT aperture diameter and permissible wire size<br />

ZCT aperture diameter (mm)<br />

15<br />

30<br />

40<br />

60<br />

80<br />

100<br />

2<br />

Max.<br />

permissible 600V rated wire size in mm (current in amperes )<br />

1ø2w<br />

P olyvinyl chloride insulated wire<br />

14<br />

(88)<br />

60<br />

(217)<br />

150<br />

(395)<br />

325<br />

(650)<br />

600<br />

(992)<br />

800 (1185)<br />

1ø3w<br />

3ø3w<br />

C ross-linked polyethylene insulated cable<br />

2 (33)<br />

38<br />

(190)<br />

60<br />

(260)<br />

250<br />

(655)<br />

400<br />

(870)<br />

600 (1140)<br />

P olyvinyl-chloride insulated wire<br />

8 (61)<br />

38<br />

(162)<br />

100<br />

(298)<br />

250<br />

(556)<br />

500<br />

(842)<br />

725 (1095)<br />

C ross-linked polyethylene insulated cable<br />

2 (33)<br />

22<br />

(135)<br />

60<br />

(260)<br />

200<br />

(560)<br />

325<br />

(760)<br />

600 (1140)<br />

3ø4w<br />

P olyvinyl-chloride insulated wire<br />

8 (61)<br />

38<br />

(162)<br />

100<br />

(298)<br />

150<br />

(395)<br />

325<br />

(650)<br />

600 (992)<br />

C ross-linked polyethylene insulated cable<br />

— 14<br />

(105)<br />

38<br />

(190)<br />

100<br />

(365)<br />

250<br />

(655)<br />

400 (870)<br />

Interchangeable ZCTs with primary conductors<br />

Type<br />

ZTA600A<br />

ZTA1200A<br />

Number<br />

of poles<br />

3<br />

ZTA2000A<br />

Rated<br />

voltage (VAC)<br />

600<br />

Rated short time current (kA) 100 (peak value )<br />

a<br />

a 227<br />

227<br />

360<br />

b 256<br />

298<br />

250<br />

ba<br />

366<br />

444<br />

594<br />

c<br />

c 42<br />

78<br />

79<br />

ca<br />

ca<br />

125<br />

176<br />

214<br />

b<br />

ba<br />

ELRs with a ZCT with primary conductors<br />

Frame (A)<br />

600<br />

1200<br />

2000<br />

3200<br />

Type<br />

ZBA<br />

ZSA<br />

ZHA<br />

ZLA<br />

Interchangeable ELR and interchangeable ZCTs with primary conductors<br />

Number<br />

of poles<br />

3<br />

NV-ZBA3200<br />

NV-ZSA3200<br />

NV-ZHA3200<br />

NV-ZLA3200<br />

Rated<br />

voltage (VAC)<br />

600<br />

Rated short time current (kA) 100 (peak value )<br />

a<br />

a 227<br />

227<br />

360<br />

490<br />

b 256<br />

298<br />

250<br />

320<br />

ba<br />

366<br />

444<br />

594<br />

868<br />

c<br />

c 42<br />

78<br />

79<br />

111<br />

ca<br />

ca<br />

125<br />

176<br />

214<br />

290<br />

Mass (kg) 6.<br />

5<br />

11<br />

27<br />

54<br />

b<br />

ba<br />

High-speed type<br />

C ontrol voltage (VAC)<br />

R ated current sensitivity (mA)<br />

M ax. operating time (s)<br />

Inertial non-operating time (s)<br />

ZBA 120<br />

• 240✳ 100<br />

• 200<br />

• 500✳<br />

ZSA<br />

120 • 240✳,<br />

240 • 415✳<br />

100<br />

• 200<br />

• 500✳<br />

0 .1<br />

—<br />

ZBA<br />

120 • 240✳<br />

100 • 200 • 500✳ 0.3 • 0.8 • 1.6✳ 0.1 • 0.5 • 1.1<br />

Specification of<br />

ELRs<br />

Time-delay type<br />

⎛High-speed • ⎞<br />

⎝Time-delay type⎠<br />

ZSA<br />

ZHA<br />

120 • 240✳<br />

240 • 415✳<br />

120 • 240✳<br />

240 • 440✳ 100 • 300 • 500✳<br />

300 • 500 • 1000✳<br />

100 • 200 • 500✳<br />

(200 • 500 • 1000✳)<br />

0.3 • 0.8 • 1.6✳ 0.1 • 0.5 • 1.1<br />

100 • 200 • 500✳ 0.1 • 0.45 • 1.0✳ – • 0.1 • 0.5<br />

0.45 • 1.0✳ (at 2l∆n) 0.1 • 0.5 (at 2l∆n)<br />

ZLA<br />

120 • 240✳<br />

240 • 440✳<br />

480<br />

100 • 200 • 500✳ 0.1 • 0.45 • 1.0✳ – • 0.1 • 0.5<br />

100 • 300 • 500✳<br />

300 • 500 • 1000✳<br />

0.45 • 1.0✳ (at 2l∆n) 0.1 • 0.5 (at 2l∆n)<br />

✳ Selectable .<br />

32


2. Detailed Specifications<br />

Circuit Protectors<br />

<strong>CIRCUIT</strong> PROTECTORS TYPE CP<br />

Frame (A) 30<br />

Type CP30-BA CP-S<br />

Photo<br />

33<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated impulse withstand voltage Uimp (kV)<br />

Rated current (A)<br />

Rated short-circuit<br />

capacity (kA)<br />

AC-DC common use<br />

Reverse connection<br />

Rated short time current<br />

(for switch only type)<br />

Mass (kg)<br />

Accessories<br />

Connection<br />

UL1077<br />

CSA C22.2 No.235 ✳ 11<br />

IEC 60934<br />

EN 60934<br />

GB 17701 ✳ 11<br />

(Icn)<br />

JIS C 4610<br />

(Icn)<br />

EN 60947-2<br />

IEC 60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Rated ambient temperature (°C)<br />

Operating characteristics<br />

Mode of tripping<br />

Method of operation<br />

Trip-free behaviour<br />

Inertial delay (ID)<br />

Alarm switch (AL)<br />

Auxiliary switch (AX)<br />

Shunt trip (SHT)<br />

Terminal cover (TC)<br />

Flushpanel mounting brackets (FP)<br />

Back facing wiring termnal (BT)<br />

Lock cover (LC)<br />

Accessory terminal cover (TC)<br />

Main body<br />

Alarm switch / Auxiliary switch<br />

AC (V)<br />

Rated voltage (V)<br />

DC (V)<br />

AC<br />

DC<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

1 2<br />

3<br />

1 2 3<br />

250<br />

250<br />

2.5 2.5<br />

0.1 0.25 0.3 0.5 1 2 3 5 7 10 15 20 30<br />

250<br />

65 125<br />

2.5kA at 250V<br />

2.5kA at 65V<br />

2.5kA at 125V<br />

250<br />

2.5/2.5kA at 60V 2.5/2.5kA at 120V –<br />

● – ✳ 1<br />

●<br />

0.08 0.16<br />

● (Medium, Slow type: AC only)<br />

Main body mounting method<br />

Srface, IEC rail mounting<br />

Flush panel mounting (option)<br />

International standard UL(cURus), CCC ✳ 5<br />

0.05 0.1 0.25 0.3 0.5 0.75 1 2 2.5 3 5 7 7.5 10 15 20 25 30<br />

250 –<br />

65 –<br />

1.5kA at 250V –<br />

1kA at 65V –<br />

250<br />

1kA at 60V<br />

✳ 1. The 3P products are use for AC only.<br />

✳ 2. Contact us for operating characteristics other than those mentioned above.<br />

✳ 3. In the pole with a shunt tripping apparatus, an over-current tripping element becomes nothing. (Switched type shunt tripping type)<br />

✳ 4. In the case of back wiring terminals, specify if it will be used with ratings 20A or less, or 30A.<br />

✳ 5. UL(cURus), CCC, and CE Marking are displayed on standard products.<br />

✳ 6. It is recognition of UL(cURus), CCC, and TUV.<br />

✳ 7. In case of DC use, only DC65V is available.<br />

✳ 8. Specify if for DC use when ordering.<br />

✳ 9. Specify when ordering. (In case of CP-S UL, type name is CP-SU.)<br />

✳ 10. Connection is male tub terminal only.<br />

✳ 11. CP30-BA only.<br />

Remark (1) The non-standard conditions products are also made by your order.<br />

(Low temperature, Moisture-fungus treatment of the 1st kind, Moisture-fungus treatment of the 2nd kind, Corrosion resistive.)<br />

(2) Although buzzing sound may be made if an instantaneous type becomes 80% or more of rated current when it is used by AC, there is no problem on a performance.<br />

Therefore, when used in a quiet environment, please select after taking this point into consideration.<br />

(3) Please use it in a circumference environment without temperature, humidity, dust, corrosive gas, vibration, and impact.<br />

And please do not use it in a circuit with inrush current, and a circuit with harmonics. It may become unnecessary action or trouble.<br />

1kA at 60V<br />

Trip-free (IEC60934)<br />

0.23<br />

0.06 0.12 0.18<br />

● (Medium, Slow, Fast type:AC only)<br />

● (1c) ✳ 7<br />

● (1c)<br />

● (for parallel and relay type:AC only)<br />

–<br />

–<br />

–<br />

● –<br />

–<br />

Male tub terminal 6.3mm (#250)<br />

[Screw terminal M4 (series type only)]<br />

Male tub terminal 2.8mm (#110)<br />

Panel mounting<br />

UL(UR) ✳ 9, 10 –<br />

⎛ Operating characteris is ⎞<br />

Medium type (M) only.<br />

EN60934 : TUV approval<br />

⎜<br />

⎟<br />

CE Marking EN60934 : TUV approval ✳ 10 The rated current, 0.3A,<br />

EN60947-2 : Self-declaration ✳ 5<br />

⎜ 2A, 3A and 7A are not ⎟<br />

⎝ applied.<br />

⎠<br />

250<br />

2.5kA at 60V 2.5kA at 120V –<br />

250<br />

2.5kA at 230V<br />

2.5kA at 60V 2.5kA at 120V –<br />

250<br />

2.5/2.5kA at 230V<br />

–<br />

40 (T40)<br />

Instantaneous type (I); Medium type (M), (MD);<br />

Slow type (S), (SD); Fast type (F) ✳ 2<br />

Instantaneous type (I): magnetic only [MO]<br />

Medium type (M), (MD)<br />

Slow type (S), (SD) : hydraulic-magnetic [HM]<br />

Fast type (F)<br />

● (1c)<br />

● (1c)<br />

● (for relay type) ✳ 3<br />

● ✳ 6<br />

●<br />

● ✳ 4, 6<br />

–<br />

● ✳ 6<br />

20A or less : Screw terminal M4<br />

30A : Screw termnal M5<br />

Screw terminal M3.5<br />

–<br />

–<br />

S-type (IEC60934)<br />

1kA at 65V<br />

–<br />

–<br />

–<br />

– ✳ 8<br />

25 (T25)<br />

Instantaneous type (I); Medium type (M), (MD);<br />

Slow type (S), (SD); Fast type (F) (FD)<br />

Instantaneous type (I): magnetic only [MO]<br />

Medium type (M), (MD)<br />

Slow type (S), (SD)<br />

Fast type (F), (FD)<br />

1.5kA at 230V<br />

2.5kA at 120V<br />

1kA at 120V<br />

(1kA at 60V) ✳ 7<br />

250<br />

1.5kA at 250V<br />

2.5kA at 125V<br />

1kA at 125V<br />

(1kA at 65V) ✳ 7<br />

–<br />

AC250V 50/60Hz 1500A 0.02s<br />

AC125V 50/60Hz 2500A 0.02s<br />

DC65V 1000A 0.02s<br />

DC125V 1000A 0.02s<br />

1kA at 65V<br />

: hydraulic-magnetic [HM]


3. Special Purpose Breakers<br />

Mag Only, DC-Use And DSN-Type<br />

Mag Only (Instantaneous tripping circuit breakers)<br />

NF63-CW/SW/HW<br />

NF125-CW/SW/HW<br />

AC, DC<br />

AC, DC<br />

Fixed<br />

NF160-SW/HW AC, DC<br />

Rated current x10<br />

NF250-CW/SW/HW AC, DC<br />

Adjustable<br />

NF400-CW/SW<br />

NF630-CW/SW<br />

NF125-SGW/HGW<br />

NF160-SGW/HGW<br />

NF250-SGW/HGW<br />

NF800-SEW<br />

NF800-SDW<br />

NF1000-SEW<br />

NF1250-SEW<br />

NF1600-SEW<br />

NF1250-SDW<br />

NF1600-SDW<br />

AC, DC<br />

AC, DC<br />

AC<br />

DC<br />

AC<br />

AC<br />

DC<br />

High: Rated current x10<br />

Low: Rated current x4<br />

(AC)<br />

High: Rated current x13<br />

Low: Rated current x5.2<br />

(DC)<br />

High: Rated current x10<br />

Low: Rated current x2<br />

High: 8000A<br />

Low: 3200A<br />

High: Rated current x10<br />

Low: Rated current x2<br />

High: Rated current x10<br />

Low: Rated current x2<br />

High: 8000A<br />

Low: 3200A<br />

Remarks: 1. The size, weight, accessories, etc., are all identical to the same-designation C, S<br />

and H series breakers.<br />

2. For more detail, contact your dealer.<br />

2<br />

3<br />

DC-Use MCCBs and DSN-type Switches<br />

Breaking is more difficult with direct currents because<br />

the current value never reaches zero. While ordinary<br />

DC breakers are suitable for low voltages, special<br />

voltage DC breakers are recommended for voltages in<br />

excess of 250VDC. Breakers for 550V are all 4-pole<br />

models.<br />

The size, shape, drilling plan, accessories, etc., are all<br />

identical to the S series of same-designation breakers.<br />

Type<br />

Number of poles<br />

Rated voltage (VDC)<br />

Rated breaking capacity (kA)<br />

IEC 60947-2 (Icu/Ics)<br />

Notes: 1: Time constant: 10ms or below.<br />

Type<br />

Number of poles<br />

Rated voltage (VDC)<br />

Interrupting capacity (kA)<br />

Instantaneous trip current (min.)<br />

NF63-SW NF125-SW NF160-SW NF250-SW NF400-SW NF630-SW NF800-SDW NF1250-SDW NF1600-SDW<br />

3<br />

400<br />

3<br />

440<br />

4<br />

550<br />

3<br />

440<br />

4<br />

550<br />

3<br />

440<br />

4<br />

550<br />

3<br />

500<br />

4<br />

600<br />

3<br />

500<br />

4<br />

600<br />

3<br />

500<br />

4<br />

600<br />

3<br />

500<br />

4<br />

600<br />

3<br />

500<br />

4<br />

600<br />

2/1 10/5 20/5 20/5 40/40 40/40 40/40<br />

40/20 40/20<br />

•DC side<br />

These breakers are designed as thyristor-Leonard<br />

system DC-side breakers. They protect the thyristor<br />

from short circuiting when there is a power or<br />

Wiring diagram for DC-usage.<br />

Wiring diagram for DC use.<br />

Note: The tripping characteristics will change if the wiring differs from the one<br />

shown here.<br />

communication failure. (Mag-Only breakers can also<br />

be used for this role.) Use these breakers in<br />

combination with fast fuses for even greater protection.<br />

NF125-SW NF160-SW NF250-SW NF400-SW NF630-SW NF800-SDW NF1250-SDW NF1600-SDW<br />

2<br />

250<br />

3<br />

440<br />

2<br />

250<br />

3<br />

440<br />

2<br />

250<br />

3<br />

440<br />

2<br />

250<br />

3<br />

440<br />

2<br />

250<br />

3<br />

440<br />

2<br />

250<br />

3<br />

440<br />

2<br />

250<br />

3<br />

440<br />

2<br />

250<br />

3<br />

440<br />

15 10 15 20 15 20<br />

20<br />

20<br />

20<br />

20<br />

20<br />

3 times rated current 3 times rated current 3 times rated current 900A<br />

1000A<br />

1400A<br />

2500A<br />

3200A<br />

•DSN-type switches<br />

These are standard MCCBs without the automatic<br />

tripping element. The tripping capacity is about six<br />

times the rated current.<br />

The appearance, size, drilling plan and available<br />

accessories are all identical to similar type standard S<br />

and C series MCCBs.<br />

Type<br />

DSN30-CS<br />

DSN63-CW DSN125-CW DSN250-CW DSN400-CW<br />

DSN630-CW<br />

DSN800-CW<br />

Rated<br />

current (A)<br />

30<br />

63 125 250<br />

400<br />

630<br />

800<br />

Number<br />

of poles<br />

2 3 2 3 2 3 2 3 2 3 3 3<br />

R ated voltage (AC/DC)<br />

460/<br />

—<br />

500/250<br />

500/250<br />

500/250<br />

600/250<br />

600/250<br />

600/250<br />

Max. switching current (AC/DC) 180/—<br />

378/155 750/310<br />

1500/625<br />

2400/1000<br />

3780/1575<br />

4800/2000<br />

Type<br />

Rated current (A)<br />

Number of poles<br />

Rated voltage (AC/DC)<br />

Max. switching current (AC/DC)<br />

DSN32-SW DSN50-SS DSN63-SW DSN125-SW DSN125-SGW DSN160-SGW DSN250-SW DSN250-SGW DSN400-SW DSN630-SW DSN800-SW DSN1000-SW DSN1250-SW DSN1600-SW<br />

32 50 63 125 125 160 250 250 400 630 800 1000 1250 1600<br />

2 3 1 2 3 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 3 4 3 4 3 4 3 4<br />

500/250 265/125 500/250 690/250 690/300 690/300 500/250 690/300 690/250 690/250 690/250 690/250 690/250 690/250<br />

192/80 300/125 378/155 750/310 750/315 960/400 1500/625 1500/625 2400/1000 3780/1575 4800/2000 6000/2500 7500/3125 9600/4000<br />

34


3. Special Purpose Breakers<br />

400Hz-Use, Instantaneous And Generator Protection<br />

400Hz-Use MCCBs<br />

Standard MCCBs cannot be used in 400Hz circuit.<br />

When standard MCCBs are used in the high frequency<br />

circuit (eq. 400Hz), the instantaneous chracteristic will<br />

be shifted higher. “400Hz use MCCBs” are<br />

reccomended to use in 400Hz circuit.<br />

•Specifications<br />

The appearance, size, rated interrupting capacity,<br />

drilling plan, accessories, etc., are all identical to the<br />

standard S and H series of same-designation breakers.<br />

Type<br />

Rated current (A)<br />

Number of poles<br />

Rated insulation voltage (V)<br />

Rated breaking capacity<br />

(kA)<br />

IEC60947-2 (Icu / Ics)<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

Note *1. Instantaneous trip current : Rated current x 14 (Fix)<br />

NF125-SW NF125-HW NF250-SW NF250-HW NF400-SW NF400-SEW NF630-SW *1 NF630-SEW NF800-SEW NF1250-SEW NF1600-SEW<br />

16, 20, 32,<br />

40, 50, 63,<br />

80, 100<br />

16, 20, 32,<br />

40, 50, 63,<br />

80, 100<br />

125, 150<br />

175, 200<br />

125, 150<br />

175, 200<br />

225, 250<br />

300, 350<br />

200~350<br />

adjustable<br />

400, 500<br />

300~500<br />

adjustable<br />

400~600<br />

adjustable<br />

600~800<br />

adjustable<br />

800~1200<br />

adjustable<br />

2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 3 4 3 4 3 4 3 4 3 4<br />

690<br />

8/4<br />

18/9<br />

25/13<br />

30/15<br />

50/25<br />

10/5<br />

30/15<br />

50/25<br />

50/25<br />

100/50<br />

–<br />

15/8<br />

25/13<br />

30/15<br />

50/25<br />

5/3<br />

30/8<br />

50/13<br />

50/13<br />

100/25<br />

10/10<br />

30/30<br />

42/42<br />

45/45<br />

85/85<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

125/63<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

125/63<br />

Low-Instantaneous MCCBs<br />

•Low-Inst. MCCBs for Discrimination<br />

When a power fuse (PF) is used for high-voltage<br />

proection, make sure that the MCCB on the secondary<br />

side is compatible.<br />

Type<br />

NF125-CW NF125-SW NF250-CW NF250-SW NF400-CW<br />

Number<br />

of poles<br />

2 3 2 3 4 2 3 2 3 4 2 3<br />

Rated current (A)<br />

50, 63, 80,<br />

100, 125<br />

16, 20, 32, 40<br />

50, 63, 80, 100,125<br />

125, 150, 175<br />

200, 225, 250<br />

125, 150, 175<br />

200, 225, 250<br />

250, 300<br />

350, 400<br />

•Specifications<br />

PF<br />

Tr1<br />

MCCB 1<br />

Time<br />

MCCB<br />

operating<br />

characteristic<br />

curve<br />

Low-inst.<br />

MCCBs<br />

PF short-time<br />

tolerance capacity<br />

Instantaneous trip<br />

(% of rated<br />

current)<br />

600<br />

● ● ● ● ●<br />

400<br />

— — ● ● ●<br />

MCCB 2<br />

Current<br />

Fig. 4.12 Low-inst. MCCB characteristics<br />

Remarks: 1. Ensure compatibility with motor, etc., before use to prevent accidental tripping at start up.<br />

2. Specify rated current and tripping characteristic.<br />

3. There are no short time delay characteristics.<br />

The appearance, size, rated interrupting capacity,<br />

accessories, etc., are all identical to the standard<br />

instantaneous trip breakers of the same designation.<br />

Generator-Protection MCCBs<br />

These breakers are designed for generator protection.<br />

•Specifications<br />

Type<br />

NF125-SGW<br />

NF125-HGW NF250-SGW NF250-HGW<br />

Number<br />

of poles<br />

3 3 3 3<br />

Rated current (A)<br />

16-32<br />

32-63<br />

63-100<br />

75-125<br />

adjustable<br />

16-32<br />

32-63<br />

63-100<br />

75-125<br />

adjustable<br />

125~250<br />

adjustable<br />

125~250<br />

adjustable<br />

Instantaneous<br />

trip (% of rated current)<br />

300<br />

✳1<br />

Operating time at 150% of rated current (s)<br />

Rated insulation voltage (V)<br />

18~28<br />

690<br />

✳1<br />

AC690V<br />

8/8<br />

20/20<br />

8/8<br />

20/20<br />

Rated breaking<br />

capacity<br />

(kA)<br />

IEC60947-2<br />

(Icu / Ics)<br />

AC500V<br />

AC440V<br />

AC400V<br />

30/30<br />

36/36<br />

36/36<br />

50/50<br />

65/65<br />

75/75<br />

30/30<br />

36/36<br />

36/36<br />

50/50<br />

65/65<br />

75/75<br />

AC230V<br />

85/85<br />

100/100<br />

85/85<br />

100/100<br />

✳1: These MCCBs operating characteristic must be adjusted as follows.<br />

STD ≤ 3 (Is setting)<br />

LTD: minimum setting (TL = 12s setting)<br />

35


3. Special Purpose Breakers<br />

MDU Breakers<br />

Measuring Display Unit (MDU)<br />

• Energy management becomes possible by measurement and display of load<br />

current, line voltage, electric power, electric energy, harmonic current (3rd, 5th,<br />

7th, 9th, 11th, 13th, 15th, 17th, 19th, and total) and power factor.<br />

• MDU with pulse output option can output pulse of electric energy.<br />

MDU with CC-Link option can transfer measured data to open network CC-Link.<br />

•<br />

When a circuit breaker outputs an alarm, LED on MDU turns on.<br />

PAL : pre-alarm<br />

OVER : over current<br />

• When the circuit breaker has tripped, fault cause and fault current stored in<br />

•<br />

EEPROM. It makes investigation of cause and restoration of power line possible.<br />

The max. demand value of load current, line voltage, total harmonic current,<br />

electric power and electric energy (hourly value), are stored in EEPROM.<br />

And MDU with CC-Link option can store the outbreak time of these. It makes easy<br />

finding of peak time of power consumption possible.<br />

NF400-SEP with MDU<br />

3<br />

Application type<br />

Type<br />

Frame size<br />

Rated current In (Amp.)<br />

Load current (Present value, demand value, maximum demand value)<br />

Line voltage (Present value, maximum value)<br />

Harmonic current (Present value, demand value, maximum demand value)<br />

Electric power (Present value, demand value, maximum demand value)<br />

Electric energy, electric energy (hourly value),<br />

maximum electric energy (hourly value)<br />

Measured<br />

Power factor (Present value)<br />

and<br />

Rated measuring current<br />

displayed Accuracy of measuring current (Limit deviation tolerance)<br />

value<br />

Rated measuring voltage<br />

Accuracy of measuring voltage (Limit deviation tolerance)<br />

Maximum measuring current (Note1.)<br />

Maximum measuring harmonic current (Note1.)<br />

Maximum measuring voltage (Note1.)<br />

Measurement range of power factor<br />

Fault current/cause (Note1.) (Note2.)<br />

Overload and short-circuit (Note 3.)<br />

Alarm LED indication<br />

Phasing line<br />

Electric energy accumulated pulse output (option) (Note3.)<br />

CC-Link transmission (option) (Note3.) (Note4.)<br />

Control power (Allowable voltage range 85~110%)<br />

Breaker mounting<br />

MDU installation<br />

Panel mounting (Note7.)<br />

Pre-alarm (PAL) (Power supply AC/DC100-240V required)<br />

Alarm contact output (option)<br />

Trip indicator (TI) (Power supply AC/DC100-240V required)<br />

NF250-SW<br />

with MDU<br />

250<br />

125, 150, 175,<br />

200, 225, 250<br />

250A<br />

±6.25A<br />

500A<br />

250A<br />

The fault cause: “AL” is<br />

displayed. The fault current: It<br />

displays it up to 10 times the<br />

rated current.<br />

(“AL switch for the MDU<br />

transmission” (option) is<br />

necessary. )<br />

Molded-Case Circuit Breaker<br />

NF400-SEP<br />

NF400-HEP<br />

with MDU<br />

400<br />

200-400<br />

adjustable<br />

400A<br />

±10A<br />

AC440V<br />

±11V<br />

800A<br />

400A<br />

AC690V<br />

Lead 0.0~100.0~0.0 Lag(%),<br />

The value of power factor is reference value if less than 50%.<br />

PAL, OVER<br />

3φ3W, 1φ3W (3 poles breaker), 3φ4W (4 poles breaker)<br />

AC/DC100-240V 12VA (Note5.)<br />

PAL<br />

NF630-SEP<br />

NF630-HEP<br />

with MDU<br />

630<br />

300-630<br />

adjustable<br />

630A<br />

±15.76A<br />

1260A<br />

630A<br />

NF800-SEP<br />

NF800-HEP<br />

with MDU<br />

800<br />

400-800<br />

adjustable<br />

800A<br />

±20A<br />

The fault cause: Overload “L” and short-circuit “SI” are<br />

displayed.<br />

The fault current: It displays it up to 16 times the<br />

maximum rated current.<br />

– PAL, OAL<br />

1600A<br />

800A<br />

Note1. When the input becomes more than the measurement maximum value, the current, the voltage, the harmonic current, and the fault current display the measurement maximum value. It does<br />

the blinking display.<br />

(However, when the fault occurs, the fault cause of and the fault current measurement value do the blinking display though it is less than measurement maximum value.)<br />

When electric power becomes more than the measurement maximum value of or either the current or the voltage becomes more than its measurement maximum value, the electric power<br />

does the blinking display.<br />

Note2. Either of overload (L) or short-circuit (SI) is displayed. It doesn’t display it at the same time.<br />

Note3. Pulse output option and CC-Link option cannot be attached at the same time.<br />

Note4. When the breaker mounting type of MDU is installed, the version of CC-Link is “Ver.1.10”.<br />

When the panel mounting type of MDU is installed, the version of CC-Link cable (FANC-SB) used for the terminal stand from the surface of MDU to the other side is “CC-Link Ver.1.00”.<br />

Note5. When control power supplied to MDU, then rushed current transitionally, max. 2Apeak, 1ms (at 240VAC).<br />

Note6. The module (terminal) is attached to the right side of the breaker.<br />

Pre-alarm (PAL) output function can set “Self-holding” or “Auto reset”.<br />

For function of alarm contact output (PAL, OAL), MDU and the circuit breaker must be connected with the mutuality and the control power must be supplied to MDU and alarm contact<br />

output module.<br />

Note7. In the case of panel mounting, the part set (the panel holder plate, the screws, the nuts and the MDU connection cable) is packed. And, the MDU connection cable is 2m (standard). (MDU<br />

connection cable can be specified by 0.5m, 3m, and as many as 5m.)<br />

36


3. Special Purpose Breakers<br />

MDU Breakers<br />

Measuring Display Unit<br />

i Numerical<br />

display LED<br />

(6digit)<br />

!4Alarm<br />

display<br />

LED<br />

o Mode<br />

selection<br />

LED<br />

!0 Phase<br />

selection<br />

LED<br />

!1 Measured<br />

value selection<br />

LED<br />

MODE PHASE VALUE FUNCTION<br />

!2 Function<br />

selection<br />

LED<br />

!3 Unit display<br />

LED<br />

(Characters light up.)<br />

u<br />

y<br />

active LED<br />

(UP) switch<br />

Displayed items and functions are changed by<br />

pushing q~r switch.<br />

Selected item is shown by LED (below o - !2).<br />

(Ex. Phase selection 1➞2➞3➞N➞1…)<br />

▲/▼ switchy is active when adjustment or<br />

reset operation is required.<br />

(▲▼ active LEDu is turned on)<br />

There may be functions which cannot be<br />

operated depending upon the specifications.<br />

The invalid function is skipped.<br />

y<br />

(DOWN) switch<br />

q Mode<br />

selection<br />

switch<br />

w Phase<br />

selection<br />

switch<br />

e Measure value<br />

selection switch<br />

r Function<br />

selection<br />

switch<br />

t ENTER<br />

switch<br />

Installed on the circuit<br />

breaker<br />

Installed on the panel<br />

37


NF250-SW with MDU<br />

Front-Connection<br />

Mounting hole<br />

100<br />

70<br />

22<br />

Insulating barrier<br />

(removable)<br />

Mounting hole<br />

100<br />

105<br />

35<br />

Insulating barrier<br />

(removable)<br />

M8 bolt<br />

(Hex-soket)<br />

4<br />

100<br />

92<br />

72<br />

68<br />

24<br />

Breaker<br />

Breaker<br />

22<br />

165<br />

144<br />

50<br />

102<br />

165<br />

144<br />

50<br />

102<br />

φ8.5<br />

126<br />

126<br />

100<br />

Trip<br />

button<br />

90<br />

105<br />

3-pole<br />

100<br />

Trip<br />

button<br />

MDU<br />

terminal<br />

cover<br />

90<br />

105<br />

140<br />

4-pole<br />

37<br />

75<br />

Neutral<br />

pole<br />

MDU<br />

MDU<br />

terminal<br />

cover<br />

30<br />

φ8.5<br />

45<br />

61<br />

φ4.5<br />

10<br />

23 max.<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

35<br />

3-pole<br />

35 35<br />

4-pole<br />

Drilling plan<br />

M4✕0.7 taps<br />

or φ5<br />

3<br />

Rear-Connection<br />

Front-plate cutout<br />

1mm clearance on each<br />

side of handle.<br />

4<br />

100<br />

92<br />

72<br />

68<br />

Mounting plate<br />

t max. 3.2<br />

Stud can be<br />

rotated 90°<br />

Insulating<br />

4-pole<br />

tube<br />

3-pole<br />

MDU<br />

Breaker<br />

105<br />

35<br />

Breaker<br />

(Load side of breaker mounting has given<br />

the space to pass wires to the terminal.)<br />

3-pole<br />

4-pole<br />

3-pole<br />

4-pole<br />

Breaker<br />

37<br />

φ8.5<br />

Connection<br />

allowance<br />

22<br />

20<br />

144<br />

8<br />

126<br />

144<br />

R1<br />

26<br />

150<br />

R1<br />

75<br />

52<br />

MDU<br />

30<br />

φ4.5<br />

45<br />

61<br />

71<br />

106<br />

15 15<br />

6<br />

φ9<br />

M8 bolt<br />

70<br />

105<br />

M4✕0.7<br />

breaker<br />

mounting<br />

screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

φ24<br />

M4✕0.7 taps<br />

or φ5<br />

Drilling plan<br />

35<br />

35<br />

4-pole<br />

φ24<br />

100<br />

32.5<br />

<br />

100<br />

32.5<br />

<br />

CC-Link ; only MDU panel mounting<br />

NF250-SW with MDU (No transmission, Pulse output)<br />

MDU panel mounting<br />

MDU is connected with circuit breaker via MDU connection cable.<br />

MDU Terminal<br />

M4 screw<br />

Upper<br />

side<br />

Operation/display<br />

side<br />

75<br />

70<br />

12<br />

28.5<br />

Panel<br />

Panel holder plate<br />

Terminal PE screw (M4)<br />

Terminal block<br />

MDU connector<br />

40<br />

M3 nut<br />

Panel<br />

thickness<br />

1~3.2mm<br />

90<br />

75<br />

MDU display<br />

part<br />

R2<br />

86.5<br />

40<br />

72<br />

40<br />

Front panel cutout<br />

Space greater than the value<br />

shown in the figure below<br />

must be secured, and must be<br />

separate 10cm or more from the<br />

distribution line.<br />

For the set<br />

installation<br />

198<br />

<br />

<br />

4<br />

3<br />

2<br />

1<br />

L2<br />

L1<br />

Control power<br />

1 2 3 4<br />

No transmission<br />

Pulse output 113 114<br />

72<br />

96<br />

85<br />

90<br />

158<br />

Terminal block<br />

M4 screw<br />

8.5<br />

54<br />

58.5<br />

30<br />

M3.5<br />

screw<br />

Terminal<br />

cover<br />

M3 nut<br />

In case of front connection,<br />

keep space between MDU and<br />

conductor or insulation<br />

barrier too.<br />

Control power<br />

L1L2 1 2 3 4 5 6<br />

No transmission<br />

Pulse output<br />

1 2 3 4 5 6<br />

FG<br />

FG 113 114<br />

38


3. Special Purpose Breakers<br />

MDU Breakers<br />

NF250-SW with MDU (CC-Link)<br />

MDU panel mounting<br />

Upper<br />

side<br />

Operation/display<br />

side<br />

43.1<br />

12<br />

M3 screw<br />

Terminal<br />

PE screw(M4)<br />

104.5<br />

28.5<br />

Terminal<br />

block<br />

55<br />

38<br />

75<br />

70<br />

58.5<br />

23<br />

MDU is connected with circuit breaker via MDU connection cable.<br />

Panel<br />

Panel holder<br />

plate<br />

MDU<br />

connector<br />

M3<br />

screw<br />

Terminal<br />

cover<br />

48<br />

67.5<br />

M3 screw<br />

M3 nut<br />

85<br />

90<br />

96<br />

M3 nut<br />

90<br />

Panel<br />

thickness<br />

1~3.2mm<br />

75<br />

MDU display<br />

part<br />

R2<br />

86.5<br />

40<br />

72<br />

76<br />

Front panel cutout<br />

Space greater than the value<br />

shown in the figure below<br />

must be secured, and must be<br />

separate 10cm or more from the<br />

distribution line.<br />

For the set<br />

installation<br />

218<br />

158<br />

In case of front connection,<br />

keep space between MDU and<br />

conductor or insulation<br />

barrier too.<br />

MDU Terminal<br />

<br />

<br />

Terminal block<br />

Control power<br />

Figure of the breaker mounting<br />

is removed the terminal cover.<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

L2<br />

L1<br />

1 2 3 4<br />

SLD DG DB DA<br />

5 6 7 8<br />

SLD DG DB DA<br />

L1L2 1 2 3 4 5 6<br />

1<br />

2<br />

3<br />

4<br />

Control power<br />

FG SLD DG DB DA<br />

5<br />

6<br />

39


NF400-SEP, NF400-HEP with MDU<br />

Front-Connection<br />

110<br />

112<br />

51<br />

Insulating barrier<br />

(removable)<br />

Mounting hole<br />

22<br />

56<br />

28<br />

16<br />

43<br />

Conductor<br />

t max.=8<br />

94.5<br />

44<br />

8<br />

Breaker<br />

Trip<br />

button<br />

39<br />

97<br />

103<br />

102<br />

257<br />

51<br />

φ12.5<br />

47<br />

φ7<br />

194<br />

PE<br />

φ14<br />

M12 bolt<br />

MDU<br />

terminal<br />

cover<br />

58<br />

90<br />

140<br />

Current<br />

indication LED<br />

OVER<br />

PAL<br />

MDU 70%<br />

36<br />

168<br />

185<br />

196<br />

39<br />

Neutral<br />

pole<br />

75<br />

30<br />

5<br />

44<br />

107<br />

131<br />

155<br />

25<br />

12<br />

φ10.5<br />

Conductor t max.=8<br />

Conductor drilling for<br />

direct connection<br />

44 M6 taps 44<br />

or φ7<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

3<br />

3-pole<br />

4-pole<br />

Rear-Connection<br />

Front-plate cutout<br />

1mm clearance on each<br />

side of handle.<br />

Mounting plate<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

MDU<br />

Breaker<br />

Eddy-current<br />

heat-reducing slit<br />

8<br />

(Load side of breaker mounting has given<br />

the space to pass wires to the terminal.)<br />

4-pole<br />

Breaker<br />

4-pole<br />

Connection<br />

allowance<br />

20<br />

25 20<br />

26<br />

225<br />

265<br />

M6 taps<br />

or φ7<br />

14<br />

225<br />

194<br />

3-pole<br />

R6<br />

3-pole<br />

R6<br />

113<br />

10<br />

φ13<br />

M12 bolt<br />

128<br />

83<br />

8<br />

87<br />

130.5<br />

M6 breaker<br />

mounting screw<br />

Insulating<br />

tube<br />

44<br />

87<br />

3-pole<br />

φ35<br />

Drilling plan<br />

44<br />

43.5<br />

130.5<br />

4-pole<br />

63 46<br />

138<br />

33<br />

37<br />

(59)<br />

118<br />

<br />

37<br />

118<br />

<br />

92<br />

Note:The drilling plan is different if insulating barriers are installed.<br />

CC-Link ; only MDU panel mounting<br />

NF400-SEP, NF400-HEP, NF630-SEP, NF630-HEP, NF800-SEP, NF800-HEP with MDU (No transmission, Pulse output)<br />

MDU panel mounting<br />

MDU is connected with circuit breaker via MDU connection cable.<br />

MDU Terminal<br />

Figure of the breaker mounting<br />

is removed the terminal cover.<br />

Upper<br />

side<br />

Operation/display<br />

side<br />

M4 screw<br />

M4 screw<br />

12<br />

28.5<br />

Terminal block<br />

40<br />

72<br />

8.5<br />

54<br />

75<br />

70<br />

Panel<br />

Terminal PE screw (M4)<br />

58.5<br />

30<br />

Panel holder plate<br />

MDU connector<br />

96<br />

M3.5<br />

screw<br />

Terminal cover<br />

M3 nut<br />

Panel<br />

thickness<br />

1~3.2mm<br />

90<br />

85<br />

90<br />

M3 nut<br />

75<br />

MDU display<br />

part<br />

R2<br />

86.5<br />

40<br />

72<br />

40<br />

For the set<br />

installation<br />

Front panel cutout<br />

Type<br />

NF400-SEP<br />

NF400-HEP<br />

NF630-SEP<br />

NF800-SEP<br />

NF630-HEP<br />

NF800-HEP<br />

Space greater than the value<br />

shown in the figure below<br />

must be secured, and must be<br />

separate 10cm or more from the<br />

distribution line.<br />

A<br />

244<br />

374<br />

253<br />

263<br />

B<br />

205<br />

205<br />

221<br />

221<br />

383 221<br />

A<br />

B<br />

In case of front connection,<br />

keep space between MDU<br />

and conductor or insulation<br />

barrier too.<br />

<br />

<br />

4<br />

3<br />

2<br />

1<br />

L2<br />

L1<br />

Control power<br />

1 2 3 4<br />

No transmission<br />

Pulse output 113 114<br />

Terminal block<br />

Control power<br />

No transmission<br />

Pulse output<br />

L1L2 1 2 3 4 5 6<br />

1 2 3 4 5<br />

6<br />

FG<br />

FG 113 114<br />

40


3. Special Purpose Breakers<br />

MDU Breakers<br />

NF630-SEP, NF630-HEP, NF800-SEP, NF800-HEP with MDU<br />

Front-Connection<br />

110<br />

32<br />

Trip<br />

button<br />

PE<br />

14<br />

40<br />

51<br />

140<br />

210<br />

3-pole<br />

85<br />

90<br />

Insulating barrier<br />

(removable)<br />

Mounting hole<br />

Current<br />

indication LED<br />

OVER<br />

PAL<br />

MDU<br />

70%<br />

MDU<br />

terminal<br />

cover<br />

70<br />

35<br />

210<br />

280<br />

50<br />

4-pole<br />

32<br />

102<br />

8<br />

15<br />

Conductor t max. 94.5<br />

600AF t8<br />

800AF t12<br />

87 275 87<br />

Neutral<br />

pole<br />

φ14<br />

M12 bolt<br />

51<br />

75<br />

30<br />

5<br />

97<br />

103<br />

φ14<br />

107<br />

131<br />

155<br />

8<br />

φ8<br />

8<br />

600AF 44<br />

800AF 46<br />

15<br />

600AF 44<br />

800AF 46<br />

Dimension of terminal<br />

directly connected to<br />

conductor<br />

φ8.5<br />

40<br />

22<br />

600AF 24<br />

800AF 26<br />

12<br />

Conductor t max.<br />

600AF t8<br />

800AF t10<br />

Conductor drilling for<br />

direct connection<br />

70<br />

3-pole<br />

Breaker<br />

M6 taps<br />

or φ7<br />

Drilling plan<br />

70<br />

4-pole<br />

243<br />

Rear-Connection<br />

Front-plate cutout<br />

1mm clearance on each<br />

side of handle.<br />

Mounting<br />

plate<br />

Connection<br />

allowance<br />

25<br />

Stud can be<br />

rotated 90°<br />

MDU<br />

M6 taps<br />

or φ7<br />

Breaker<br />

Eddy-current<br />

heat-reducing slit<br />

5<br />

4-pole<br />

(Load side of breaker mounting has given<br />

the space to pass wires to the terminal.)<br />

4-pole<br />

15<br />

10<br />

3-pole<br />

Breaker<br />

3-pole<br />

Breaker<br />

8<br />

40<br />

243<br />

295<br />

12.5<br />

243<br />

R6<br />

R6<br />

13<br />

46<br />

10<br />

113<br />

110<br />

32<br />

φ13<br />

M12 bolt<br />

8<br />

140<br />

M6 breaker<br />

mounting<br />

screw<br />

70<br />

140<br />

φ48<br />

70<br />

70<br />

210<br />

6<br />

(86)<br />

51<br />

46<br />

138<br />

172<br />

51<br />

92<br />

3-pole<br />

4-pole<br />

172<br />

Drilling plan<br />

<br />

<br />

Note:The drilling plan is different if insulating barriers are installed.<br />

CC-Link ; only MDU panel mounting<br />

NF400-SEP, NF400-HEP, NF630-SEP, NF630-HEP, NF800-SEP, NF800-HEP with MDU (CC-Link)<br />

MDU panel mounting<br />

MDU is connected with circuit breaker via MDU connection cable.<br />

MDU Terminal<br />

Figure of the breaker mounting<br />

is removed the terminal cover.<br />

Upper<br />

side<br />

43.1<br />

Operation/display<br />

side<br />

M3 screw<br />

38<br />

Terminal<br />

PE screw(M4)<br />

104.5<br />

12<br />

28.5<br />

Terminal<br />

block<br />

55<br />

75<br />

70<br />

58.5<br />

23<br />

Panel<br />

Panel holder<br />

plate<br />

MDU<br />

connector<br />

48<br />

M3<br />

screw<br />

67.5<br />

Terminal<br />

cover<br />

M3 screw<br />

M3 nut<br />

85<br />

90<br />

96<br />

M3 nut<br />

Panel<br />

thickness<br />

1~3.2mm<br />

90<br />

75<br />

MDU display<br />

part<br />

R2<br />

86.5<br />

40<br />

72<br />

Space greater than the value<br />

shown in the figure below<br />

must be secured, and must be<br />

separate 10cm or more from the<br />

distribution line.<br />

76<br />

Front panel cutout<br />

Type<br />

NF400-SEP<br />

NF400-HEP<br />

NF630-SEP<br />

NF800-SEP<br />

NF630-HEP<br />

NF800-HEP<br />

For the set<br />

installation<br />

A<br />

263<br />

393<br />

272<br />

282<br />

B<br />

205<br />

205<br />

221<br />

221<br />

402 221<br />

A<br />

B<br />

In case of front connection,<br />

keep space between MDU<br />

and conductor or insulation<br />

barrier too.<br />

<br />

<br />

Terminal block<br />

Control power<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

L2<br />

L1<br />

1 2 3 4<br />

SLD DG DB DA<br />

5 6 7 8<br />

SLD DG DB DA<br />

L1L2 1 2 3 4 5 6<br />

1<br />

2<br />

3<br />

4<br />

FG SLD DG DB DA<br />

5<br />

Control power<br />

6<br />

41


4. Connection Method<br />

1. Connection Types<br />

Table 4-1: Connection Types<br />

Connection Method (Abbreviation) Front connection (F) Solderless terminal<br />

Rear connection (B)<br />

The front connection model will be delivered unless otherwise specified. Notice, however,<br />

that you can convert the front connection model to other types (excluding the plug-in) by<br />

using an appropriate connection component, which is separately available.<br />

Plug-in (PM)<br />

Appearance<br />

2. Connection Accessories<br />

Table 4-2: List of Connection Accessories<br />

✽1<br />

3<br />

Type name<br />

Solderless terminal (SL) Rear studs (B-ST) Plug-in (PM) ✽1<br />

NF32-SW, NF63-CW/SW/HW<br />

NF32-SW, MB30-SW, MB50-CW/SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW<br />

NF63-SW/HW<br />

NV100-SEP/HEP<br />

NF125-CW/SW<br />

NF125-HW<br />

NF125-CW/SW/HW, MB100-SW, NV125-CW/SW/HW<br />

NV125-RW<br />

2P<br />

3P<br />

4P<br />

3P<br />

2P<br />

3P<br />

–<br />

SL-1SW4L ✽ 3<br />

SL-1SW4G ✽ 4<br />

SL-1SW3L ✽ 3<br />

SL-1SW3G ✽ 4<br />

ST-05SW2<br />

ST-05SW3<br />

ST-05SW4<br />

ST-1SP3<br />

ST-1SW2<br />

ST-1HW2<br />

ST-1SW3<br />

PM-05SW2<br />

PM-05SW3<br />

PM-05SW4<br />

PM-1SP3<br />

PM-1SW2<br />

PM-1HW2<br />

PM-1SW3<br />

PM-1UW3<br />

4<br />

NF125-SW/HW, NV125-SW/HW<br />

4P<br />

SL-1SW4L ✽ 3<br />

SL-1SW4G ✽ 4<br />

ST-1SW4<br />

PM-1SW4<br />

NF250-CW/SW/HW, NF160-SW/HW<br />

2P<br />

SL-2SW4L ✽ 5<br />

SL-2SW4G ✽ 6<br />

ST-2SW2<br />

PM-2SW2<br />

NF250-CW/SW/HW, MB225-SW, NF160-SW/HW, NV250-CW/SW/HW/RW/SEW/HEW<br />

NV250-RW<br />

3P<br />

SL-2SW3L ✽ 5<br />

SL-2SW3G ✽ 6<br />

SL-2UW3L ✽ 5<br />

SL-2UW3G ✽ 6<br />

ST-2SW3<br />

ST-2UW3<br />

PM-2SW3<br />

NF250-SW/HW, NF160-SW/HW, NV250-SW/HW/SEW/HEW<br />

NF250-SGW/HGW, NF160-SGW/HGW, NF125-SGW/HGW<br />

NF250-RGW/UGW, NF125-RGW/UGW<br />

NF250-SGW/HGW, NF160-SGW/HGW, NF125-SGW/HGW<br />

NF250-RGW/UGW, NF125-RGW/UGW<br />

NF250-SGW/HGW, NF160-SGW/HGW, NF125-SGW/HGW<br />

NF250-UGW, NF125-UGW<br />

NF400-CW/SW<br />

NF400-CW/SW/SEW, NV400-CW/SW/SEW<br />

NF400-HEW/REW, NV400-HEW/REW<br />

NF400-SW/SEW, NV400-SEW<br />

NF400-HEW, NV400-HEW<br />

NF630-CW/SW<br />

NF630-CW/SW/SEW, NV630-CW/SW/SEW<br />

NF630-HEW/REW, NV630-HEW<br />

NF630-SW/SEW, NV630-SEW<br />

NF630-HEW<br />

NF800-SDW<br />

NF800-CEW/SEW, NV800-SEW<br />

NF800-HEW/REW, NV800-HEW<br />

NF800-SEW<br />

NF800-HEW<br />

4P<br />

2P<br />

3P<br />

4P<br />

2P<br />

3P<br />

3P<br />

4P<br />

4P<br />

2P<br />

3P<br />

3P<br />

4P<br />

4P<br />

2P<br />

3P<br />

3P<br />

4P<br />

4P<br />

SL-2SW4L ✽ 5<br />

SL-2SW4G ✽ 6<br />

SL-2GSW4<br />

SL-2GSW3<br />

SL-2GSW4<br />

Notes: ✽ 1 You can use the plug-in terminal unit (PM) when the wiring of terminal units is required in advance, and the delivery of both the main body and the components at the same time,<br />

which is normal, is not allowed. Furthermore specify the nonuse of plug-in terminal (PM-N) for the connection of circuit breaker.<br />

✽ 2 If safety device is necessary ,please require.<br />

✽ 3 Connected wire size: 2.5~25mm 2<br />

✽ 4 Connected wire size: 25~70mm 2<br />

Line<br />

Load<br />

✽ 5 Connected wire size: 14~95mm 2<br />

✽ 6 Connected wire size: 70~125mm 2<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

ST-2SW4<br />

ST-2GSW2<br />

ST-2GSW3<br />

ST-2GSW4<br />

ST-4SW2<br />

ST-4SW3<br />

ST-4SW4<br />

ST-6SW2<br />

ST-6SW3<br />

ST-6SW4<br />

ST-8SW2<br />

ST-8SW3<br />

ST-8SW4<br />

PM-2SW4<br />

PM-2GSWIP2 ✽ 2<br />

PM-2GUW2<br />

PM-2GSWIP3 ✽ 2<br />

PM-2GUW3<br />

PM-2GSWIP4 ✽ 2<br />

–<br />

PM-4SW2<br />

PM-4SW3<br />

PM-4SW4<br />

PM-6SW2<br />

PM-6SW3<br />

PM-6SW4<br />

PM-8SW2<br />

PM-8SW3<br />

PM-8SW4<br />

3. Connection of Line and Load<br />

The standard wiring of line and load on the circuit breaker is (a) normal connection shown on<br />

the right. Avoid the wiring shown in (b) reverse connection, which may lead to the decrease in<br />

breaking performance. However, the reverse connection is allowed for the following models<br />

(except NF models with MDU).<br />

NF-C series, NF-S series, NF-H series, NF-U series,<br />

MB series, C • S • H series of NV400~800A Frame<br />

Reverse connection is allowed for the standard models.<br />

Load<br />

Line<br />

Normal connection (a) Reserve connection (b)<br />

Normal and reverse connection methods<br />

42


5. Accessories<br />

Internal Accessories<br />

1. Accessories<br />

Table 5-1: Accessories<br />

Internal accessories Function Applicable models Cassette-type of accessories<br />

AL Alarm switch A switch that electrically indicates the trip status of the circuit breaker. NF-C·S·H·U,<br />

●<br />

Auxiliary switch A switch that electrically indicates the ON-OFF status of the circuit breaker.<br />

NV-C·S·H·U<br />

and MB series<br />

●<br />

AX<br />

SHT<br />

UVT<br />

EAL<br />

TBM<br />

MG<br />

PAL<br />

OAL<br />

OFF or ON<br />

Trip<br />

OFF or Trip<br />

ON<br />

Shunt trip<br />

A<br />

Note: (1) Models NV250-SEW/HEW are excluded.<br />

Over current, short circuit<br />

trip or on or off<br />

Ground-fault trip<br />

Undervoltage trip<br />

A<br />

Earth-leakage alarm switch<br />

A<br />

Test button module<br />

This<br />

Insulation switch<br />

The<br />

Pre-alarm module<br />

Overcurrent trip alarm switch<br />

Indicates<br />

2. Switch Operation and Rating<br />

Table 5-2: AL Switch Operation<br />

Circuit breaker status<br />

Table 5-3: AX Switch Operation<br />

Circuit breaker status<br />

Table 5-4: EAL Switch Operation<br />

Circuit breaker status<br />

250A frame or less<br />

400A frame or more<br />

250A frame or less<br />

400A frame or more<br />

Table 5-5: MG Switch Operation<br />

Circuit breaker status<br />

device that electrically trips the circuit breaker from a remote distance.<br />

Permissible working voltages are 70 to 110% of the AC rated voltage or<br />

70 to 125% of the DC rated voltage.<br />

device that automatically trips the circuit breaker if the voltage is lowered.<br />

Working voltages are 70 to 35% of the UVT rated voltage. When the voltage<br />

recovers to 85% or higher, you can reset the device and put into operation.<br />

switch that electrically indicates the trip status of the earth leakage circuit<br />

breaker caused by a ground fault. If 250AF and less, This switch is available<br />

only for models with the vertical lead-wire terminal unit (SLT).<br />

module allows you a remote testing by applying a voltage.<br />

An external sequence common to SHT can be used. (The standard<br />

configuration requires the vertical lead-wire terminal unit (SLT).)<br />

incorporation of this switch enables the measurement of insulation resistance<br />

between the terminals of the load with the circuit breaker being turned OFF.<br />

that the load current exceeds the pre-alarm setting current.<br />

Indicates that the breaker has been tripped by overcurrent or short-circuit current.<br />

AL switch contact<br />

AX switch contact<br />

EAL switch contact<br />

MG switch status<br />

98/ALa (open)<br />

96/ALb (closed)<br />

95/ALc<br />

98/ALa (closed)<br />

96/ALb (open)<br />

95/ALc<br />

14/AXa (open)<br />

12/AXb (closed)<br />

11/AXc<br />

14/AXa (closed)<br />

12/AXb (open)<br />

11/AXc<br />

EALa (open)<br />

EALc<br />

EALa (open)<br />

EALb (closed)<br />

EALc<br />

EALa (closed)<br />

EALc<br />

EALa (closed)<br />

EALb (open)<br />

EALc<br />

Table 5-6: AL·AX·EAL Switch Rating (In case of EAL, 400AF and more)<br />

Switch<br />

type<br />

S<br />

V<br />

*1<br />

X<br />

Note: *1. When DC use polarity must be considered.<br />

Please contact us for applications in the field of smaller current values.<br />

Table 5-7: EAL Switch Rating (250AF and less)<br />

Voltage<br />

(V)<br />

Voltage<br />

(V)<br />

Resistive<br />

load<br />

AC<br />

Resistive<br />

load<br />

Inductive<br />

load<br />

A control power supply (compatible to<br />

100 and 200V AC) is required; see the<br />

diagram on the right showing its wiring.<br />

(The permissible range of voltage of the<br />

control power supply is 80 to 242V AC,<br />

and the power requirement is 10VA.)<br />

NF-C·S·H·U<br />

and MB series<br />

NF-C·S·H·U, (Note 1)<br />

NV-C·S·H·U<br />

and MB series<br />

NV-C·S·H·U –<br />

NV-C·S·H·U –<br />

NV-C·S·H·U –<br />

Electronic Types –<br />

Electronic Types<br />

(SGW, HGW, RGW, UGW)<br />

Current (A)<br />

Inductive<br />

load<br />

Voltage<br />

(V)<br />

DC<br />

Resistive<br />

load<br />

–<br />

Current (A)<br />

Inductive<br />

load<br />

460 – – 250 0.2 0.2<br />

250 3 2 125 0.4 0.4<br />

125 5 3 30 4 3<br />

460<br />

250<br />

125<br />

460<br />

250<br />

125<br />

AC<br />

Current A<br />

5<br />

10<br />

10<br />

5<br />

10<br />

10<br />

200 3 2<br />

100 3 2<br />

2<br />

10<br />

10<br />

2.5<br />

10<br />

10<br />

250<br />

125<br />

30<br />

250<br />

125<br />

30<br />

0.3<br />

0.6<br />

10<br />

5<br />

10<br />

10<br />

●<br />

●<br />

0.3<br />

0.6<br />

Vertical lead-wire<br />

terminal unit<br />

EALa<br />

Indicator lamp<br />

(example)<br />

P2 Control power<br />

supply<br />

P1(EALc)<br />

6<br />

3<br />

6<br />

10<br />

OFF or Trip<br />

MG switch (open)<br />

ON<br />

MG switch (closed)<br />

43


3. Maximum Number of Internally Mounted Accessories<br />

Handle AL AX SHT or UVT TI Cassette-type accessories<br />

Left-side<br />

Right-side<br />

mounting<br />

mounting MG EAL TBM Lead wire direction<br />

Table 5-8: Combinations of Accessories<br />

Series NF-C · S · H · U, MB NV-C · S · H · U<br />

Type<br />

Poles<br />

NF30-CS<br />

MB30-CS<br />

NF32-SW<br />

NF63-CW/SW/HW<br />

NF125-CW/SW<br />

NF32-SW(3P)<br />

NF63-CW/SW/HW(3P)<br />

NF125-CW(3P), NF125-SW(3P, 4P)<br />

NF125-HW, NF125-SGW/HGW<br />

NF125-RGW/UGW<br />

NF160-SW/SGW/HW/HGW<br />

NF250-CW/SW/HW<br />

NF250-SGW/HGW<br />

NF250-RGW/UGW<br />

MB30-SW, MB50-CW/SW<br />

MB100-SW, MB225-SW<br />

NV32-SW<br />

NV63-CW/SW/HW<br />

NV125-CW/SW/HW<br />

NV250-CW/SW/HW<br />

NV250-SEW/HEW<br />

NV125-RW, NV250-RW<br />

2, 3 2<br />

2, 3, 4 3<br />

3, 4<br />

(Note 7)<br />

NV30-CS<br />

(Note 7)<br />

AL<br />

1 2<br />

(Note 7)<br />

(Note 7)<br />

AX<br />

1 2<br />

AL + AX<br />

SHT or UVT<br />

3-pole product only<br />

(Note 7)<br />

1 2<br />

1 2<br />

(Note 1)<br />

(Note 2) (Note 2)<br />

(Note 3)<br />

(Note 7)<br />

(Note 1)<br />

(Note 2)<br />

(Note 4)<br />

(Note 6)<br />

AL + SHT or UVT<br />

AX + SHT or UVT<br />

(Note 2)<br />

(Note 2)<br />

5<br />

Accessories<br />

AL + AX + SHT or UVT<br />

(Note 1)<br />

(Note 2)<br />

MG<br />

(Note 7)<br />

AL + MG<br />

AX + MG<br />

(Note 5)<br />

EAL<br />

(Note 9)<br />

TBM<br />

PAL<br />

Notes: (1) Second AX can substitute the AL on the left-pole.<br />

(2) Models with UVT require a UVT voltage module to be installed on the lead-wire terminal unit. (No such voltage module is required for SHT.) Part of UVT accessories is not of<br />

cassette type. (Details will be available upon request.)<br />

(3) UVTs for left-pole installation can be produced, if specified, for frame current values of 125A (excluding SGW/HGW/RGW/UGW).<br />

(4) SHT cannot be installed.<br />

(5) EALs are available only for models with the vertical lead-wire terminal unit (SLT). Specify a control power supply of either 100 or 200 V AC.<br />

(6) Models NV250-SEW/HEW are not allowed to install the UVT device.<br />

(7) The standard lead drawing is performed laterally. Load drawing is also available.<br />

(8) Only the models with an SLT are available. EAL and PAL require a control power supply (shared 100 - 200 VAC).<br />

For the 24 VDC TBM only, instruct us of a control voltage. (The standard shared voltage is 100 - 240 VAC/100 - 240 VDC.)<br />

(9) Models CE marking are not allowed to install the TBM device.<br />

Remarks: (1) Circled numbers indicate the order of installation.<br />

(2) Accessories of EAL, and TBM can be installed independent of installations of AL, AX, and MG. (Two units among EAL, and TBM cannot be installed at the same time.)<br />

44


5. Accessories<br />

Internal Accessories<br />

Left-side<br />

mounting<br />

Handle AL AX SHT or UVT TI Cassette-type accessories<br />

Right-side<br />

mounting MG EAL TBL PAL TBM Lead wire direction<br />

Type<br />

NF-C/S/H<br />

NF400-CW/SW<br />

NF400-SEW/HEW/REW<br />

NF630-CW/SW<br />

NF630-SEW/HEW/REW<br />

NF800-CEW/SDW<br />

NF800-SEW/HEW/REW<br />

NF1000-SEW<br />

NF1250-SEW<br />

NF1600-SEW<br />

NF1250-SDW<br />

NF1600-SDW<br />

NF-U<br />

NF400-UEW (3P)<br />

NF400-UEW (4P), NF800-UEW<br />

—<br />

Poles<br />

2, 3, 4<br />

Switch<br />

type<br />

S V<br />

✳3<br />

AL<br />

✳3<br />

AX<br />

1 3<br />

2 4<br />

1 5 3<br />

2 6 4<br />

1<br />

2<br />

5<br />

3<br />

4<br />

6<br />

SHT<br />

or<br />

UVT<br />

✳1<br />

✳2<br />

✳1<br />

✳2<br />

✳2<br />

✳3<br />

✳3<br />

AL + AX<br />

Accessories<br />

AL + SHT or UVT<br />

✳1<br />

✳2<br />

✳3<br />

✳4<br />

✳1<br />

✳2<br />

✳3<br />

✳4<br />

✳2<br />

AX + SHT or UVT<br />

3<br />

1<br />

2<br />

✳1<br />

✳2<br />

✳3<br />

✳4<br />

1 3<br />

2 4<br />

3<br />

4<br />

5<br />

1<br />

2<br />

✳1<br />

✳2<br />

✳3<br />

✳4<br />

✳2<br />

AL + AX + SHT or UVT<br />

✳1<br />

✳2<br />

✳3<br />

✳4<br />

✳1<br />

✳2<br />

✳3<br />

✳4<br />

✳2<br />

✳5<br />

✳5<br />

✳5<br />

PAL<br />

(contact output)<br />

Option for<br />

NF400-SEW/HEW/REW/UEW (3P)<br />

NF630-SEW/HEW/REW<br />

✳6<br />

Option for NF400-UEW(4P)<br />

NF800-CEW/SEW/HEW/REW/UEW<br />

✳6<br />

Option for NF1000-SEW<br />

NF1250-SEW<br />

NF1600-SEW<br />

TI<br />

Option for NF400-SEW/HEW/REW/UEW (3P)<br />

NF630-SEW/HEW/REW<br />

Option for NF400-UEW(4P)<br />

NF800-CEW/SEW/HEW/REW/UEW<br />

45<br />

The number within the circle shows the order of mounting.<br />

✳ 1.<br />

SHT and UVT are right-pole mounting as standard. Please specify if left-pole mounting is required.<br />

✳ 2. UVT mounting requires a UVT voltage module (SHT requires no such voltage module) .<br />

✳ 3. When mounting more than three left-pole mounting devices by SLT, or when mounting a SHT or UVT to the same pole as the AL, AX or AL + AX, a special-order SLT is necessary .<br />

✳ 4. When mounting a UVT to the same pole as the AL, AX, or AL + AX, the UVT voltage module is separate .<br />

✳ 5. SLT-equipped is standard. Control voltage (AC100~200V) is necessary. (In this case, no other accessories can be mounted to the breaker's right pole. )<br />

✳ 6. SLT-equipped is standard. Control voltage (AC100~200V/DC100~200V) is necessary. (In this case, no other accessories can be mounted to the breaker's right pole. )


Left-side<br />

mounting<br />

Handle AL AX SHT or UVT TI Cassette-type accessories<br />

Right-side<br />

mounting MG EAL TBL PAL TBM Lead wire direction<br />

Type<br />

NV-C/ S/H<br />

NV400-CW/SW<br />

NV400-SEW/HEW/REW<br />

NV630-CW/SW<br />

NV630-SEW/HEW<br />

Poles<br />

3, 4<br />

NV800-SEW/HEW<br />

Switch<br />

type<br />

S<br />

✳2<br />

AL<br />

✳2<br />

AX<br />

✳1<br />

✳1<br />

SHT or UVT<br />

AL + AX<br />

✳2<br />

✳2<br />

5<br />

Accessories<br />

AL + SHT or UVT<br />

✳1<br />

✳2<br />

✳3<br />

✳1<br />

✳2<br />

✳3<br />

AX + SHT or UVT<br />

✳1<br />

✳2<br />

✳3<br />

✳1<br />

✳2<br />

✳3<br />

AL + AX + SHT or UVT<br />

✳1<br />

✳2<br />

✳3<br />

✳1<br />

✳2<br />

✳3<br />

MG<br />

AL + MG<br />

The number within the circle shows the order of mounting.<br />

✳ 1. UVT mounting requires a UVT voltage module (SHT requires no such voltage module) .<br />

✳ 2. When mounting more than three left-pole mounting devices by SLT, or when mounting a SHT or UVT to the same pole as the AL, AX or AL + AX, a special-order SLT is necessary .<br />

✳ 3. When mounting a UVT to the same pole as the AL, AX or AL + AX. the UVT voltage module is separate .<br />

46


5. Accessories<br />

Internal Accessories<br />

Left-side<br />

mounting<br />

Handle AL AX SHT or UVT<br />

Right-side<br />

mounting MG EAL TBL PAL<br />

TI<br />

TBM<br />

Lead wire direction<br />

Type<br />

NV-C/ S/H<br />

NV400-CW/SW<br />

NV400-SEW/HEW/REW<br />

NV630-CW/SW<br />

NV630-SEW/HEW<br />

NV800-SEW/HEW<br />

Poles<br />

3, 4<br />

Switch<br />

type<br />

S<br />

AX + MG<br />

AL + AX + MG<br />

EAL<br />

Accessories<br />

TBL<br />

TBM<br />

✳1<br />

✳1<br />

PAL (contact output)<br />

Option for NV400-SEW/HEW/REW<br />

NV630-SEW/HEW<br />

Option for NV800-SEW/HEW<br />

✳2<br />

✳2<br />

TI<br />

Option for NV400-SEW/HEW/REW<br />

NV630-SEW/HEW<br />

Option for NV800-SEW/HEW<br />

The number within the circle shows the order of mounting.<br />

1. EAL, TBL, and TBM can be mounted regardless of the number of AL, AX, SHT, UVT and MG accessories. (However, two EALs, TBLs or TBMs cannot be mounted simultaneously.)<br />

2. The PAL’s dimensions and specifications change for the NF-C/S and NV-C/S series.<br />

✳ 1.<br />

SLT-equipped is standard. Control voltage (AC100-200V) is necessary. (In this case, no other accessories can be mounted to the breaker’s right pole.)<br />

✳ 2.<br />

SLT-equipped is standard. Control voltage (AC100-200V/DC100-200V) is necessary. (In this case, no other accessories can be mounted to the breaker’s right pole.)<br />

47


Left-side<br />

mounting<br />

Handle AL AX SHT or UVT<br />

Right-side<br />

mounting<br />

Type<br />

NF-C/S/H<br />

NF50-SWU<br />

NF100-CWU<br />

NF100-SWU<br />

NF50-SWU<br />

NF100-CWU<br />

NF100-SWU<br />

NF-SFW<br />

NF-SJW<br />

NF-HJW<br />

NF225-CWU NF-SKW NF-SLW<br />

Poles<br />

2 3<br />

3<br />

Switch<br />

type<br />

S S<br />

(Note 6)<br />

AL<br />

1 2<br />

1 2<br />

1 2<br />

(Note 6)<br />

AX<br />

1 2<br />

1 2<br />

1 2<br />

1 3<br />

2 4<br />

1 5 3<br />

2 6 4<br />

(Note 1) (Note 1)<br />

(Note 1)<br />

(Note 2)<br />

(Note 2)<br />

(Note 2)<br />

SHT<br />

or<br />

UVT<br />

Accessories<br />

AL + AX<br />

1 2<br />

1 2<br />

(Note 4)<br />

1 2<br />

1 2<br />

(Note 4)<br />

1 2<br />

1 2<br />

(Note 4) (Note 6)<br />

(Note 6)<br />

5<br />

(Note 1)<br />

(Note 1)<br />

(Note 2)<br />

(Note 1)<br />

(Note 6)<br />

(Note 5)<br />

(Note 7)<br />

(Note 1)<br />

(Note 6)<br />

(Note 5)<br />

(Note 7)<br />

AL + SHT or UVT<br />

(Note 1)<br />

(Note 1)<br />

(Note 2)<br />

(Note 1)<br />

(Note 6)<br />

(Note 5)<br />

(Note 7)<br />

(Note 1)<br />

(Note 6)<br />

(Note 5)<br />

(Note 7)<br />

AX + SHT or UVT<br />

1 3<br />

2 4<br />

5<br />

3<br />

1<br />

2<br />

3<br />

4<br />

1<br />

2<br />

AL + AX + SHT<br />

or<br />

UVT<br />

(Note 1)<br />

(Note 4)<br />

(Note 1)<br />

(Note 4)<br />

(Note 2)<br />

(Note 4)<br />

(Note 1)<br />

(Note 6)<br />

(Note 5)<br />

(Note 7)<br />

(Note 1)<br />

(Note 6)<br />

(Note 5)<br />

(Note 7)<br />

Notes: (1) If a UVT is used, a UVT voltage module is installed on the lead wire terminal block. (The SHT requires no voltage module.)<br />

(2) If a UVT is used, a UVT voltage module is installed on the lead wire terminal block. (The SHT requires no voltage module.) No cassette is attached to the UVT.<br />

(3) If a UVT is used, the UVT voltage module is externally installed. (The SHT requires no voltage module).<br />

(4) The 2nd AX can be installed instead of the AL on the left pole.<br />

(5) The standard mounting of the SHT and the UVT is performed on the right pole. If mounting on the left pole is required, instruct us. (The UVTs for interlocks are mounted on the left pole.)<br />

(6) We can manufacture the SLTs used when 3 or more accessories are installed on the left pole and the SLTs used when the AL and the AX are attached on the same pole that is<br />

attached with the SHT or the UVT at your order.<br />

(7) If a UVT is used and an AL, an AX or an AL + an AX are attached to the same pole that is attached with the UVT, the UVT voltage module is separately installed.<br />

Remarks: (1) Encircled numbers show the order of mounting.<br />

48


5. Accessories<br />

Internal Accessories<br />

4. Shunt Trip (SHT)<br />

Table 5-9: Standard Coil Rating<br />

Series<br />

32(30) • 63A Frame<br />

125A Frame<br />

(NF125-SGW/HGW/RGW/UGW are excluded)<br />

160 • 250A Frame<br />

NF125-SGW/HGW/RGW/UGW<br />

Cut-off<br />

switch<br />

Voltage (V)<br />

AC100-240<br />

380-550<br />

(Compatible to 50 and 60Hz. )<br />

DC100-125<br />

Input power requirement (VA) (Note 1)<br />

AC<br />

DC<br />

50<br />

120<br />

60<br />

Operating time (ms) (Note 2)<br />

15 or less<br />

NF-C • S • H • U<br />

MB<br />

NV-C • S • H • U<br />

400 • 630 • 800 Frame<br />

NF400-CW/SW/SEW/HEW/REW/UEW<br />

NF630-CW/SW/SEW/HEW/REW<br />

NF800-SDW/CEW/SEW/HEW/REW/UEW<br />

NV400-CW/SW/SEW/HEW/REW<br />

NV630-CW/SW/SEW/HEW, NV800-SEW/HEW<br />

Equipped<br />

AC100~450/DC100~200<br />

(50 also 60Hz)<br />

100V : 20<br />

200V : 50<br />

330V : 120<br />

450V : 170<br />

100V : 10<br />

200V : 35<br />

5~15<br />

1000 • 1250 • 1600 Frame<br />

NF1000-SEW, NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

AC100-120<br />

200-240<br />

380-450<br />

(50 also 60Hz)<br />

DC100<br />

200 70 7~15<br />

Notes: (1) Secure a sufficient input power so that the voltage will not drop below the permissible lower working voltage (70% of the lowest rated voltage).<br />

(2) The operating time denotes the time from when the rated voltage is applied to SHT until when the main contact of the breaker starts to open.<br />

Table 5-10: Coil Ratings (List of manufacturable special voltages)<br />

A C ( V )<br />

D C (V )<br />

MCCB type<br />

24<br />

24~48 48<br />

380<br />

~ 550<br />

12<br />

24<br />

24~36 36<br />

36~48 48<br />

110<br />

125<br />

220<br />

~250<br />

AC/DC<br />

(V)<br />

24<br />

~48<br />

NF-C • S • H • U<br />

MB<br />

32(30) • 63A Frame 125A Frame 160 • 250A Frame<br />

–<br />

● – –<br />

● – ● – ● – – – ● –<br />

NF400-CW/SW/SEW/HEW/REW, NF630-CW/SW/SEW/HEW/REW<br />

NF800-SDW/CEW/SEW/HEW/REW, NF400-UEW, NF800-UEW<br />

NV400-CW/SW/SEW/HEW/REW, NV630-CW/SW/SEW/HEW, NV800-SEW/HEW<br />

– – – ● ● – – – – – – – –<br />

●<br />

NF1000-SEW, NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

● – ● – ● ● – ● – ● ● ● – –<br />

5. Undervoltage Trip (UVT)<br />

Table 5-11: Coil Rating<br />

Series<br />

250AF and less<br />

NF400-CW/SW/SEW/HEW/REW/UEW<br />

NF630-CW/SW/SEW/HEW/REW<br />

NF800-CEW/SDW/SEW/HEW/REW/UEW<br />

NV400-CW/SW/SEW/HEW/REW<br />

NV630-CW/SW/SEW/HEW<br />

NV800-SEW/HEW<br />

NF1000-SEW<br />

NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

Voltage (V)<br />

(Note 1)<br />

Standard voltage Special voltage (note 5)<br />

AC100-110/120-130 selectable<br />

200-220/230-250 selectable<br />

380-415/440-480 selectable<br />

(Note4)<br />

DC100/110 selectable<br />

AC100-110<br />

200-220<br />

400-440<br />

(Note4)<br />

DC100<br />

AC100-120<br />

200-240<br />

380-450<br />

(Note4)<br />

DC100-110<br />

AC24/48 selectable<br />

500-550/600 selectable<br />

DC24/48 selectable<br />

110/125 selectable<br />

AC110-120<br />

220-240<br />

380-415<br />

440-480<br />

500-550<br />

(Note4)<br />

DC24<br />

48<br />

110<br />

AC24<br />

48<br />

440-480<br />

500-550<br />

(Note4)<br />

DC24<br />

48<br />

120-125<br />

Input<br />

power<br />

(VA)<br />

Operating<br />

time (ms)<br />

(Note 2) (Note 3)<br />

5 30 or less<br />

5 5~30<br />

5 5~35<br />

Notes: (1) A desired voltage can be selected by changing the terminal wiring.<br />

(2) The operating time denotes the time from when no voltage is applied to UVT until when the main contact of the breaker<br />

starts to open.<br />

(3) Time-delayed types can be produced. Details will be available upon request.<br />

(4) Compatible to 50 and 60Hz<br />

(5) Rated voltage differs according to make and country of manufacture.Please consult your dealer.<br />

● UVT Voltage Module<br />

The UVT voltage module is<br />

normally installed on the<br />

vertical lead-wire terminal<br />

unit (SLT). (A separatemount<br />

type can be produced<br />

upon request.)<br />

Circuit<br />

breaker<br />

D3/P3<br />

D2/P2<br />

J1/UC1<br />

J2/UC2<br />

UVT Voltage Module Wiring Diagram<br />

(Lead-Wire Connection)<br />

UVT voltage module<br />

D1/P1<br />

J1/UC1<br />

J2/UC2<br />

49


6. Test Button Module (TBM)<br />

● The effect of pressing the test button on the breaker main body is<br />

produced while the input control voltage is applied. (Apply the voltage<br />

for more than two seconds for the breaker main body of time-delayed<br />

NV models.)<br />

● The model with the vertical lead-wire terminal unit (SLT) is standard.<br />

Table 5-12<br />

Series<br />

NV-C • S • H • U<br />

18<br />

Input rated<br />

control<br />

voltage (V)<br />

Input control<br />

power (VA)<br />

Compatible to<br />

AC100-240/<br />

DC100-240<br />

(DC24) (Note 1)<br />

1VA or less<br />

Note: (1) The specifications of 100-240V<br />

AC/100-240V DC are standard<br />

unless otherwise specified. The<br />

specifications of 24 V DC are<br />

available if requested.<br />

7<br />

12.5<br />

10.5<br />

(10.5)<br />

TBM2<br />

TBM1<br />

92 (Terminal<br />

cover)<br />

7. Lead-wire Specifications<br />

Table 5-13<br />

Type Size Length Marking Ring-mark example<br />

Heatresistant<br />

wire<br />

0.5mm 2 (Note 1)<br />

450mm<br />

A ring-mark marked<br />

by the terminal symbol<br />

is attached to each<br />

lead-wire.<br />

98/ALa , 96/ALb , 95/ALc<br />

C1/S1 , C2/S2<br />

Note: (1) The length is 400 mm for the model of four-pole, right-pole installation.<br />

● Lead wires are normally extended laterally.<br />

● Grooves are provided standardly on the side face of the breaker,<br />

allowing the extension of the lead wires along them. (Note 1)<br />

Note: (1) The models of NF125-SGW/HGW/RGW/UGW, NF160-SGW/HGW,<br />

NF250-SGW/HGW/RGW/UGW, 400Aframe and more are excluded.<br />

5<br />

8. Internal Terminal Type (INT)<br />

● This unit is an internal accessory that is provided with terminal screws for lead-wire connection.<br />

Remark: (1) Available for the models of NF125-SGW/HGW/RGW/UGW,<br />

NF160-SGW/HGW, NF250-SGW/HGW/RGW/UGW.<br />

50


5. Accessories<br />

Internal Accessories<br />

9. Vertical Lead-wire Terminal Block (SLT)<br />

● The circuit beaker can be mounted, being closely fitted to the unit.<br />

● Terminal screws are arranged in a zigzag pattern, and screws can be tightened further after wiring.<br />

● A terminal cover is provided standardly.<br />

● This unit supports the models of front connection, rear connection, and plug-in type (excluding PLT).<br />

■NFB<br />

86.5 B<br />

A C<br />

Terminal cover<br />

(Skeleton)<br />

25 10.5<br />

10.5<br />

18<br />

7<br />

12.5<br />

D<br />

Table 5-14: Summary of Dimensions<br />

Applicable models A B C D<br />

4<br />

4.5 44.5 4.5<br />

7<br />

17.5 54 17.5<br />

NF30-CS, MB30-CS<br />

NF32-SW, NF63-CW/SW/HW<br />

MB30-SW, MB50-CW/SW<br />

NF50-SWU<br />

NF125-CW/SW/HW<br />

NF100-CWU, NF100-SWU<br />

NF125-HGW, NF225-HGW<br />

NF-SFW,NF-SJW, NF-HJW<br />

NF250-CW/SW/HW, NF225-CWU, NF160-SW/HW<br />

NF400-CW/SW/SEW/HEW/REW, NF-SKW, NF630-CW/SW/SEW/HEW/REW<br />

NF800-CEW/SDW/SEW/HEW/REW, NF-SLW<br />

NF1000-SEW, NF1250-SEW/SDW, NF1600-SEW/SDW<br />

NF400-UEW(3P)<br />

NF400-UEW(4P), NF800-UEW<br />

Remark: (1) Terminal screw tightening torque M3.5 ··· 0.9~1.2N·m<br />

7<br />

7<br />

7<br />

25<br />

25<br />

7<br />

41<br />

62.5<br />

138<br />

27.5<br />

19<br />

29<br />

25<br />

35<br />

37<br />

79.5<br />

88.5<br />

173<br />

119.5<br />

135.5<br />

54<br />

54<br />

54<br />

54<br />

54<br />

54<br />

54<br />

54<br />

52<br />

54<br />

54<br />

27.5<br />

19<br />

29<br />

25<br />

35<br />

37<br />

79.5<br />

88.5<br />

173<br />

119.5<br />

135.5<br />

M3.5 terminal screw<br />

26<br />

14<br />

86.5 B<br />

Terminal cover<br />

(Skeleton)<br />

25 10.5<br />

10.5<br />

18<br />

F<br />

G<br />

Applicable models A B C D E<br />

4 4.5 44.5 44.5 4<br />

7 17.5 54 52 7<br />

7 19 54 54 7<br />

7 37 54 52 2.5<br />

7 80 54 54 7<br />

7 112 54 52 2.5<br />

41 79.5 54 52 26.5<br />

88.5 54 52 26.5<br />

7<br />

12.5<br />

D<br />

NV30-CS<br />

NV32-SW, NV63-CW/SW/HW<br />

NV125-CW/SW/HW<br />

NV250-CW/SW/HW, NV250-SEW/HEW, NV225-CWU<br />

NV125-RW<br />

NV250-RW<br />

NV400-CW/SW/HW/HEW/REW, NV630-CW/SW/SEW/HEW<br />

NV800-SEW/HEW<br />

41<br />

Remarks: (1) Terminal screw tightening torque M3.5 ··· 0.9~1.2N·m<br />

(2) Lead-wire terminal block for TBL is attached to right-side.<br />

F<br />

4.5<br />

21.5<br />

19<br />

37<br />

80<br />

112<br />

79.5<br />

88.5<br />

G<br />

86.5<br />

92<br />

86.5<br />

92<br />

86.5<br />

92<br />

92<br />

92<br />

A<br />

C<br />

M3.5 terminal screw<br />

38<br />

38<br />

8<br />

13.5<br />

■NV<br />

Table 5-15: Summary of Dimensions<br />

26<br />

14<br />

8<br />

13.5<br />

E<br />

■14 Terminals SLT<br />

B<br />

SLT when three and more than<br />

three pieces of internal accessories<br />

are mounted on left-side.<br />

Terminal cover<br />

(Skeleton)<br />

115<br />

11<br />

11<br />

11<br />

41<br />

9<br />

25<br />

Table 5-16<br />

Applicable models<br />

NFB<br />

NV<br />

NF400-CW/SW/SEW<br />

NV400-CW/SW/SEW<br />

NF400-HEW/REW, NF-SKW<br />

NV400-HEW/REW<br />

NF630-CW/SW/SEW<br />

NV630-CW/SW/SEW/HEW<br />

NF630-HEW/REW<br />

NF400-UEW(3P)<br />

–<br />

NF800-CEW/SDW/SEW<br />

NF800-HEW/REW, NF-SLW<br />

NV800-SEW/HEW<br />

NF1000-SEW, NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

–<br />

NF400-UEW(4P), NF800-UEW<br />

–<br />

Remark: (1) Terminal screw tightening torque M3.5 ··· 0.9~1.2N·m<br />

A<br />

B<br />

20<br />

60<br />

117<br />

100<br />

20<br />

69<br />

35 154<br />

117<br />

116<br />

7<br />

M3.5 terminal screw<br />

17<br />

A 75<br />

51


10. Pre-Alarm Module (PAL)<br />

This module functions to give alarm output when<br />

load current exceeds a preset current level and<br />

serves for securing continuous power supply and<br />

also for preventive maintenance. The electronic<br />

breakers with mount digital ETR of 125 to<br />

1600AF are provided with this module as an<br />

option. (Some modules are with this module as<br />

standard equipment.)<br />

Table 5-17<br />

NF125-SGW/HGW<br />

NF160-SGW/HGW<br />

NF250-SGW/HGW<br />

NV250-SEW/HEW<br />

Type<br />

NF400-SEW NF400-HEW NF400-REW<br />

NF400-UEW NF630-SEW NF630-HEW<br />

NF630-REW NF800-CEW NF800-SEW<br />

NF800-HEW NF800-REW NF800-UEW<br />

NV400-SEW NV400-HEW NV400-REW<br />

NV630-SEW NV630-HEW NV800-SEW<br />

NV800-HEW<br />

NF1000-SEW NF1250-SEW NF1600-SEW<br />

Pre-alarm LED<br />

(Auto reset)<br />

Standard equipment<br />

Solid state relay (SSR) output-<br />

Contacties output (Auto reset)<br />

Option<br />

Option<br />

—<br />

Pre-alarm module-Contact output (1a)<br />

S witching capacity ( Self-holding)<br />

Switching<br />

capacit y<br />

24VDC 100-200VAC<br />

20mA<br />

24VDC 100-200VAC<br />

20mA<br />

Option<br />

100VAC or<br />

200VAC 2A<br />

Reset system<br />

Press the reset switch or<br />

turn off control power.<br />

Pre-alarm LED<br />

Solid-state relay output<br />

Pre-alarm module<br />

• Pre-alarm characteristics<br />

Operating time<br />

5h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Pre-alarm<br />

pickup current Ip<br />

In x(0.7-0.75<br />

-0.8-0.85-0.9 ± 10%<br />

-0.95-1.0)<br />

Pre-alarm<br />

operatiing time Tp<br />

TL<br />

Tp= ± 20%<br />

2<br />

(at 200%)<br />

The LED starts blinking on the circuit breaker when load current exceeds the preset current, then changes to continuous glowing<br />

when pre-alarm output is given.<br />

Open the upper cover of the circuit breaker, connect the connector of the lead wire packed together and use it as the lead wire<br />

outlet. In this case, only the lead wire outlet of the internal accessories can be attached to the right pole. (For flush plate type,<br />

the outlet is manufactured in advanced as a PAL mount.)<br />

SLT is attached as standard and is used as the control power source of 100VAC or 200VAC. In this case, no other internal<br />

accessories can be attached to the right pole. (Auto resetting is also applicable.)<br />

Pre-alarm pick-up current<br />

LTD operating time TL<br />

60-80-100s ± 20%<br />

(at 200%)<br />

60 70 100 125 200 300 400 500 600 700 1000 1500<br />

Current<br />

Percentage (%) to rated current or preset current rating<br />

(NF/NV125,250AF)<br />

Operating time<br />

10h<br />

5h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Pre-alarm<br />

pickup current Ip<br />

In x(0.7-0.75<br />

-0.8-0.85-0.9 ± 10%<br />

-0.95-1.0)<br />

Pre-alarm<br />

operatiing time Tp<br />

TL<br />

Tp= ± 20%<br />

2<br />

(at 200%)<br />

Pre-alarm pick-up current<br />

LTD operating time TL<br />

12-60-100-150s ± 20%<br />

(at 200%)<br />

60 70 100 125 200 300 400 500 600 700 1000 1500<br />

Current<br />

Percentage (%) to rated current or preset current rating<br />

NF/NV400,630,800AF<br />

NF1000,1250,1600AF<br />

5<br />

PAL OUT LED<br />

RISET<br />

Reset switch<br />

PALa<br />

Indicator lamp (Example)<br />

P2<br />

P1<br />

(PALc)<br />

(100VAC or 200VAC)<br />

Control power pre-alarm output<br />

In the case of flush plate type. this is mounted on back<br />

side of the circuit breaker.<br />

52


5. Accessories<br />

Internal Accessories<br />

11. Trip Indicator (TI)<br />

When the breaker is tripped, this accessory installed on the right side will<br />

display the cause of the trip--either long delay (LTD) , short or instantaneous<br />

(STD/INST), earth-leakage (EAL) (with earth-leakage breakers only)--on its<br />

LED and output an alarm signal. In this case, both LTD and STD/INST are<br />

treated as overcurrent trips (OAL) and output signals. Pre-alarm is also<br />

output. Again, with this module, it is impossible to connect other internal<br />

accessories to the breaker’s right side.)<br />

Table 5-18<br />

Type<br />

NF400-SEW/HEW/REW/UEW<br />

NF630-SEW/HEW/REW<br />

NF800-CEW/SEW/HEW/REW/UEW<br />

LED contents<br />

Long-time delay, Short-time delay, Instantaneous, Pre-alarm<br />

98<br />

25<br />

control power supply<br />

P1<br />

P2<br />

Control voltage<br />

Long-time delay(LTD) alarm LED<br />

Pre-alarm(PAL)LED<br />

Earth-leakage alarm (EAL)LED<br />

Short-time(STD),<br />

instantaneous(INST) alarm LED<br />

Reset switch<br />

PALa<br />

Pre-alarm output<br />

PALc<br />

OALa Overcurrent<br />

OALc alarm output<br />

EALa Earth -leakage<br />

EALc alarm output<br />

NV400-SEW/HEW/REW, NV630-SEW/HEW<br />

NV800-SEW/HEW<br />

Long-time delay, Short-time delay, Instantaneous,<br />

Earth-leakage, Pre-alarm<br />

✳ Requires 100-200VAC control voltage.<br />

12. 3ø4W Neutral-pole protection Relay (NR)<br />

●<br />

In a 3-phase 4-wire circuits, the voltage rise of the circuit by phase failure of a neutral line is detected, and a<br />

contact output is taken out.<br />

Table 5-19<br />

Phase/wire type<br />

Rated<br />

voltage<br />

Usable supply voltage<br />

Usable voltage (line voltage)<br />

Tripping<br />

characteristics<br />

Trip<br />

indication method<br />

eset method<br />

Total<br />

operating overvoltage (phase voltage) (135% of total phase voltage)<br />

Total<br />

non-operating overvoltage (phase voltage) (120% of total phase voltage)<br />

T otal overvoltage operating time<br />

)<br />

O vervoltage non-operating time<br />

)<br />

3 ø 4W<br />

VAC<br />

415<br />

VAC<br />

304~484<br />

VAC<br />

380<br />

400<br />

415<br />

440<br />

VAC<br />

296<br />

312<br />

323<br />

343<br />

VAC<br />

263<br />

277<br />

288<br />

305<br />

( s<br />

1<br />

( s<br />

More than 0. 1<br />

Button<br />

Reset button (open-phase display use<br />

1c<br />

R )<br />

External output contacts<br />

Remark: Using with a shunt-trip device (SHT) equipped breaker will improve tripping and phase protection.<br />

AC<br />

Voltage<br />

cos ø<br />

1.0<br />

. 4<br />

Voltage<br />

100,<br />

120V 7A<br />

7A<br />

0V<br />

200,<br />

240V 7A<br />

7A<br />

25V<br />

415V<br />

5A<br />

2A<br />

50V<br />

DC<br />

L/R<br />

0 0 0.007<br />

3 7A<br />

6A<br />

1 0.6A<br />

0.6A<br />

2 0.3A<br />

0.3A<br />

68 7.5<br />

20<br />

63<br />

R pole S Pole T Pole<br />

Test button<br />

Operation display<br />

(reset button)<br />

Current switch<br />

N pole NRaNRbNRc<br />

Item output terminal<br />

60<br />

11.5 11.5<br />

83<br />

Drilling plan<br />

ø5mm or M4 x 0.7mm screw<br />

52 52<br />

min.12<br />

52<br />

92.5<br />

57<br />

37.5<br />

M3.5 x 0.6 screw<br />

self-tap terminal<br />

74<br />

6<br />

109<br />

4.8 x 6.8 mounting hole<br />

mounting screw M4 x 0.7 mm<br />

10.5<br />

39<br />

9.5<br />

53


5. Accessories<br />

External Accessories<br />

TR<br />

1. V-type Operating Handle<br />

● Appearance (Color N1.5)<br />

● Outside Dimension Diagram<br />

A<br />

Front base<br />

Front plate<br />

Center of Hinge and<br />

Circuit Breaker<br />

Handle<br />

Front plate<br />

I P<br />

PED<br />

O<br />

N<br />

B<br />

90<br />

H<br />

H<br />

OFF<br />

● This handle in conjunction with the breaker main<br />

enables the isolation function effective.<br />

● The safety standards of EN Standards<br />

(EN60204-1) are satisfied.<br />

● Degrees of protection (IEC60529) IP65 is<br />

satisfied standardly.<br />

● OFF-position lock only is available for up to three<br />

commercial padlocks (35mm, 40mm).<br />

● A door-lock mechanism allows the door to be<br />

opened at OFF-position only.<br />

RESET<br />

16<br />

90<br />

Plate<br />

thickness<br />

1.2–3.2<br />

● Mounting-hole Drilling Dimension Diagram<br />

Center of the<br />

circuit breaker<br />

operating handle<br />

H<br />

C L<br />

54<br />

C<br />

Minimum E<br />

Maximum F<br />

Circuit breaker Center of the<br />

operating handle<br />

Center of the circuit<br />

breaker operating handle<br />

H<br />

D<br />

Center of the<br />

circuit breaker<br />

(Note 1)<br />

Left<br />

Hinge<br />

X<br />

Circuit<br />

breaker<br />

C L C L<br />

C L C L<br />

(Note 1)<br />

C L<br />

H<br />

X<br />

0 or more (5H+100) or more<br />

The above illustration shows a view<br />

of the hinges and the circuit breaker<br />

when viewed from the direction of<br />

the load.<br />

● Front Plate Drilling<br />

Dimension Diagram<br />

Center of the circuit breaker<br />

operating handle<br />

ø9<br />

X<br />

Right<br />

Hinge<br />

G<br />

Either M4×0.7<br />

screw or ø5<br />

G<br />

J<br />

G<br />

Either M4×0.7<br />

screw or ø5<br />

Circuit<br />

breaker<br />

C L<br />

ø54<br />

54<br />

Table 5-20: Summary of Dimensions<br />

Type name<br />

Applicable models<br />

3-pole<br />

4-pole<br />

Note 1: The drilling at this position is not required for the models of both V2GSW and V2GSWF.<br />

Number<br />

of poles<br />

Dimensions (mm)<br />

A B C D E F G H J<br />

3P 75<br />

V05SW NF32-SW, NF63-CW/SW/HW, NV32-SW<br />

154 300<br />

4P 100<br />

NV63-CW/SW/HW, MB30-SW<br />

130 44 61<br />

MB50-CW/SW<br />

3P 75<br />

V05SWF (Note 2)<br />

125 –<br />

4P 100<br />

3P 90<br />

V1SW<br />

154 518<br />

NF125-CW/SW/HW, NV125-CW/SW/HW<br />

4P 120<br />

130 44 61<br />

MB100-SW<br />

3P 90<br />

V1SWF (Note 2)<br />

125 –<br />

4P 120<br />

2P, 3P 105<br />

V2SW<br />

154 518<br />

NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW<br />

4P 140<br />

165 46 61<br />

NV250-SEW/HEW, MB225-SW<br />

2P, 3P 105<br />

V2SWF (Note 2)<br />

125 –<br />

4P 140<br />

2P, 3P 105<br />

V2GSW<br />

172 536<br />

4P 140<br />

NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW<br />

165 46 79<br />

2P, 3P 105<br />

V2GSWF (Note 2)<br />

143 –<br />

4P 140<br />

Notes: (1) This hole is not required for two and three poles.<br />

(2) The last letter of “F” of the type designations of V-type operating handles denotes a fixed type.<br />

Remark: (1) You may contact us for details of the V-type operating handle for the U series.<br />

54<br />

25 111<br />

30 111<br />

35 126<br />

35 126<br />

–<br />

12.5<br />

–<br />

12.5<br />

–<br />

15<br />

–<br />

15<br />

–<br />

17.5<br />

–<br />

17.5<br />

–<br />

17.5<br />

–<br />

17.5<br />

5<br />

✽Equipped with cylinder key (option) to prevent deliberate operation.<br />

● Can be locked in OFF position only.<br />

● The door is locked when ON and can only be<br />

opened in OFF position.<br />

● Degrees of protection (in accordance with<br />

IEC60529): IP65.<br />

External dimensions<br />

A<br />

B<br />

C<br />

Handle<br />

Front panel<br />

Outview<br />

Drilling plan<br />

Breaker<br />

Center of<br />

breaker's handle<br />

63<br />

104<br />

4- 10<br />

104<br />

L<br />

Center of<br />

breaker's handle<br />

Breaker<br />

M6 screw<br />

or 7<br />

N<br />

Hinge<br />

(left side)<br />

X<br />

N<br />

O or more<br />

Breaker<br />

X<br />

Front panel<br />

N<br />

X<br />

P or more<br />

Hinge<br />

(right side)<br />

Table 5-21<br />

Type<br />

Panel<br />

thickness<br />

1.2~3.2<br />

E<br />

G<br />

D F Minimum J<br />

Maximum K<br />

MCCB<br />

H<br />

(a)<br />

B reakers type<br />

F ig.<br />

Dimensions (mm)<br />

ELCB<br />

V4SW<br />

NF400-CW, NF400-SW, NF400-SEW<br />

N F400-HEW<br />

NF630-CW, NF630-SW, NF630-SEW<br />

—<br />

NF630-HEW<br />

NV400-CW, NV400-SW<br />

V4SWNV<br />

—<br />

NV400-SEW, NV400-HEW<br />

NV630-CW, NV630-SW<br />

NV630-SEW, NV630-HEW<br />

V8SW<br />

NF800- CEW, NF800-SDW, NF800-SEW<br />

NF800-HEW<br />

NV800-SEW, NV800-HEW<br />

NF400-CW, NF400-SW, NF400-SEW<br />

V4SWF<br />

N F400-HEW<br />

NF630-CW, NF630-SW, NF630-SEW<br />

—<br />

NF630-HEW<br />

NV400-CW, NV400-SW<br />

V4SWFNV<br />

—<br />

NV400-SEW, NV400-HEW<br />

NV630-CW, NV630-SW<br />

NV630-SEW, NV630-HEW<br />

V8SWF<br />

NF800-CEW,NF800-SDW,<br />

NF800-SEW<br />

NF800-HEW<br />

Outvie w<br />

a<br />

(b)<br />

M<br />

(c)<br />

The above illustration shows a view<br />

of the hinges and the circuit breaker<br />

when viewed from the direction of<br />

the load.<br />

Drilling<br />

A B C D E F G H J K L M P<br />

plan<br />

b, c<br />

NV800-SEW, NV800-HEW 75<br />

257<br />

140<br />

140<br />

140<br />

25<br />

62<br />

76<br />

97<br />

217<br />

539<br />

194<br />

44<br />

8N+150<br />

275<br />

140<br />

210<br />

140<br />

25<br />

62<br />

76<br />

97<br />

217<br />

539<br />

243<br />

70<br />

8N+150<br />

257<br />

140<br />

140<br />

140<br />

25<br />

62<br />

76<br />

97<br />

191<br />

– 194<br />

44<br />

8N+150<br />

2 140<br />

210<br />

140<br />

25<br />

62<br />

76<br />

97<br />

191<br />

– 243<br />

70<br />

8N+150<br />

54


O F<br />

F<br />

OFF<br />

ON<br />

ON<br />

REL<br />

E<br />

5. Accessories<br />

External Accessories<br />

2. F-type Operating Handle<br />

● Appearance (Color N1.5)<br />

● This handle in conjunction with the breaker<br />

enables the isolation function effective.<br />

● The standard model is equipped with a safety<br />

device that prevents the circuit breaker from<br />

being turned on if the door is open. (If not<br />

desired, please specify so.)<br />

● The handle can be locked at either ON or<br />

OFF position. (Three padlocks (35mm,<br />

40mm) can be installed. OFF-position lock<br />

only specifications are also acceptable.)<br />

● Degrees of protection (IEC60529) IP3X<br />

(IP5X with dustproof packing)<br />

Remark: (1) Trip action can be displayed when the circuit<br />

breaker trips even if ON-position lock is selected<br />

(only in the case of a single padlock (35 mm)).<br />

● Outside Dimension Diagram<br />

RESET<br />

OPEN<br />

● Drilling Dimension Diagram<br />

Center of the circuit<br />

breaker operating handle 4-ø12<br />

Circuit<br />

breaker<br />

CL<br />

TRIPPED<br />

104<br />

CL<br />

78<br />

AS E<br />

ø90<br />

104<br />

78<br />

51<br />

Plate<br />

thickness 1.2–3.2<br />

A±2<br />

Circuit breaker<br />

CL<br />

(a)<br />

(b)<br />

CL<br />

B<br />

Center of<br />

the circuit<br />

breaker<br />

and the<br />

operating<br />

handle<br />

(b)<br />

(a)<br />

C<br />

D<br />

Center of Hinge and Circuit Breaker<br />

Left hinge<br />

Right hinge<br />

H X1 H X2<br />

Left hinge<br />

Front plate<br />

H<br />

X1<br />

Operating handle<br />

circuit<br />

breaker<br />

The above illustration shows a view of<br />

the hinges and the circuit breaker when<br />

viewed from the direction of the load.<br />

Table 5-22: Summary of Dimensions<br />

Type name<br />

Applicable models<br />

Number<br />

Dimensions (mm)<br />

of poles A *1 B C D<br />

*2 F05SW2P *3 F05SWR2P NF32-SW, NF63-CW/SW/HW 2P<br />

–<br />

*2 F05SW *3 F05SWR<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-SW/HW, MB30-SW, MB50-CW/SW 3P, 4P<br />

111<br />

25<br />

NV63-CW/SW<br />

3P 105<br />

Either<br />

*2 F1SW2P *3 F1SWR2P NF125-CW/SW/HW 2P –<br />

M4×0.7<br />

111<br />

*2 F1SW *3 F1SWR NF125-CW/SW/HW, NV125-CW/SW/HW, MB100-SW<br />

3P, 4P 30<br />

screw or ø5<br />

*2 F2SW *3 F2SWR NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW, NV250-SEW/HEW, MB225-SW 2P, 3P, 4P 107 35 126<br />

*2 F2GSW *3 F2GSWR NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW<br />

3P, 4P 125 35 126<br />

*1. Dimensions of both front connection and rear connection are shown. The plug-in type has a different reference plane for mounting the circuit breaker.<br />

*2. The standard type is epuipped with a door-lock mechanism that allows door to be opened only when OFF operation is carried out.<br />

*3. In case of reset opened type use.<br />

Remarks: (1) The test button becomes difficult to press when an operating handle is installed on an NV model. Then, use models with either TBM instead.<br />

(2) Dustproof packings are separately available.<br />

(3) You may consult us for details of the F-type operating handle for the U series.<br />

● Appearance (Color N1.5)<br />

● External dimensions<br />

Center of Hinge and Circuit Breaker<br />

RESTE<br />

TPRIEPD<br />

Flusf plate<br />

150<br />

Front panel<br />

0<br />

or more<br />

Left<br />

hinge<br />

(5H+100)<br />

or more<br />

Less than<br />

10<br />

10<br />

or more<br />

X2<br />

H<br />

170<br />

or more<br />

(5H+120)<br />

or more<br />

Right hinge<br />

Mounting<br />

screws<br />

(a) Circuit<br />

breaker<br />

mounting screws<br />

(2pcs)<br />

(b) Handle<br />

mounting screws<br />

(2pcs)<br />

Right hinge<br />

H X1<br />

H X2<br />

0 or more ( 8H +150) or more<br />

0 or more<br />

(4H + 120) or more<br />

● Includes as standard a safety device which<br />

prevents breaker closing as long as the cover is<br />

open. (Specify if this safety feature is not required.)<br />

● Indicates the tripping of the breaker even in<br />

ON-lock position--but only in cases when a<br />

single padlock (35mm, 40mm) is used.<br />

● Degrees of protection (in accordance with<br />

IEC60529): IP3X (IP5X with dustproof<br />

packing).<br />

Table 5-23<br />

F4SW ~ F8UW<br />

Type<br />

*6 F4SW *7 F4SWR<br />

*6 F4SWNV *7 F4SWRNV<br />

*6 F4UW *7 F4UWR<br />

*6 F8SW *7 F8SWR<br />

*6 F8SWNV *7 F8SWRNV<br />

*6 F8UW *7 F8UWR<br />

*7 F10SW<br />

*7 F10SW4P<br />

F10SW ~ F120UR4P<br />

*1. Handles with NV in the product name include a test button.<br />

*2. Dustproof packing is also available as an option.<br />

*3. Other optional handles can also be mounted.<br />

*4. F4SW~F8UW are for isolation purposes.<br />

(Speify OFF lock only.)<br />

Breaker type<br />

(a)<br />

● Drilling plan<br />

Center of breaker<br />

F<br />

112<br />

118<br />

4- 15<br />

NF400-CW/SW/SEW/HEW/REW , NF630-CW/SW/SEW/HEW/REW<br />

NV400-CW/SW/SEW/HEW/REW , NV630-CW/SW/SEW/HE W<br />

NF400-UEW<br />

NF800-CEW/SDW/SEW/HEW/REW<br />

NV800-SEW/HEW<br />

NF400-UEW (4P), NF800-UEW<br />

NF1000-SEW, NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

150<br />

Release screw<br />

112<br />

(b)<br />

Plate thickness 1.2-3.2<br />

B A ± 2<br />

Breaker<br />

(X)<br />

(Y)<br />

C<br />

Number of poles<br />

2P, 3P, 4P<br />

3P, 4P<br />

P<br />

2P, 3P, 4P<br />

3P, 4P<br />

(Y)<br />

(X)<br />

D<br />

E<br />

(c)<br />

External<br />

dimensions<br />

Left hinge<br />

H<br />

X1<br />

F-type operating handle<br />

Front panel<br />

Breaker<br />

H<br />

Right hinge<br />

The figure above shows the relationship<br />

between the hinge and breaker viewed<br />

from the load side of the breaker.<br />

F ig<br />

Dimensions (mm)<br />

Drilling<br />

*5<br />

p lan<br />

A B C D E F<br />

183<br />

44<br />

194<br />

3 280<br />

44<br />

234<br />

M6 screw<br />

20<br />

53<br />

or ø7<br />

a b c 183<br />

70<br />

243<br />

—<br />

3P, 4P<br />

2P, 3P<br />

4P<br />

*5. The figures show the dimensions of the front connection. Some connection and plug-in breakers have a different reference<br />

surface for mounting purposes.<br />

*6. The standard type is equipped with a door-lock mechanism that allows the door to be opened only when OFF operation is<br />

carried out.<br />

*7. In case of reset opened type use.<br />

X2<br />

—<br />

280 70<br />

290<br />

23. 5<br />

221 50 70 375<br />

M8 screw<br />

or ø10<br />

—<br />

Mounting<br />

crews<br />

(X), (Y)<br />

Breaker<br />

mounting<br />

screws<br />

(4 pcs)<br />

55


F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

Specification explanation for F-type operating handles<br />

Specification Detailed explanation Kind<br />

The position where it can lock<br />

ON and OFF-position lock<br />

with the padlock.<br />

Handle lock position<br />

Can not open, when it use<br />

padlock.<br />

TRIPPED<br />

ON<br />

OFF-position lock only<br />

TRIPPED<br />

ON<br />

TRIPPED<br />

1<br />

ON<br />

2<br />

When OFF-lock, please turn<br />

handle in RESET direction.<br />

O F<br />

RESET<br />

O F<br />

RESET<br />

O F<br />

RESET<br />

The door can be opened with the<br />

operating handle RESET-position<br />

or OFF-position.<br />

When the operating handle was<br />

locked, the panel (door) can not<br />

be opened.<br />

OFF-position<br />

TRIPPED<br />

ON<br />

RESET-position open<br />

RESET-position<br />

Lock lever<br />

TRIPPED<br />

ON<br />

OFF-position open<br />

OFF-position<br />

TRIPPED<br />

ON<br />

Door opening system<br />

O F<br />

O F<br />

O F<br />

RESET<br />

RESET<br />

RESET<br />

Lock plate<br />

Lock lever locked<br />

by lock plate<br />

Lock lever unlocked<br />

by lock plate<br />

Lock lever unlocked<br />

by lock plate<br />

Mounting direction<br />

The top of label is ON side of<br />

breaker<br />

ON side<br />

Reconstruction to vertically from<br />

horizontally can not be<br />

performed.<br />

Vertically type<br />

(ON side of breaker is upper)<br />

TRIPPED<br />

ON<br />

Horizontally type<br />

(ON side of breaker is left)<br />

TRIPPED<br />

ON<br />

Horizontally type<br />

(ON side of breaker is right)<br />

TRIPPED<br />

ON<br />

5<br />

O F<br />

O F<br />

O F<br />

RESET<br />

RESET<br />

RESET<br />

Label<br />

For emergency stop use.<br />

For emergency<br />

(In accordance with EN60204-1)<br />

TRIPPED<br />

ON<br />

Red color<br />

You may consult us for details<br />

*<br />

of emergency<br />

O F<br />

RESET<br />

Yellow color<br />

56


5. Accessories<br />

External Accessories<br />

OFF<br />

ON<br />

57<br />

3. S-type Operating Handle<br />

● Appearance (Color N1.5)<br />

● The handle can be locked at either ON or<br />

OFF position. (Three padlocks (35mm,<br />

40mm) can be installed. Off-position lock only<br />

specifications are also acceptable.)<br />

● Digrees of protection (IEC60529) IP5X<br />

Remark: (1) Trip action can be displayed when the circuit<br />

breaker trips even if ON-position lock is selected<br />

(only in the case of a single padlock (35 mm)).<br />

Table 5-24: Summary of Dimensions<br />

Type name<br />

S05SW<br />

Table 5-25<br />

max. 150<br />

max. 145<br />

● Outside Dimension Diagram<br />

Operating plate<br />

Max. 95<br />

Max. 115<br />

Operating<br />

plate<br />

34 40<br />

47<br />

59<br />

Front plate<br />

Face plate<br />

Front panel<br />

Decorative plate<br />

(a)<br />

OFF<br />

OFF<br />

TRIP<br />

45<br />

ON<br />

TRIP ON<br />

55<br />

110<br />

110<br />

–<br />

–<br />

–<br />

–<br />

Operating plate<br />

114<br />

Operating plate<br />

114<br />

130(S4CP·S4SP)<br />

180(S100)<br />

80<br />

● Front Plate Drilling Dimension Diagram<br />

*3<br />

62<br />

35 ± 5<br />

*1<br />

Retainer<br />

Center of breaker's<br />

handle<br />

*1<br />

Retainer<br />

*2<br />

Retainer<br />

(option)<br />

ø62<br />

(Note 3)<br />

41.5±4<br />

Clasp<br />

(Note 1)<br />

Center of the circuit breaker<br />

operating handle<br />

17<br />

Notes: (1) The clasps are not supplied standardly, and should be prepared by users Details on dimensions and others will be available upon request.<br />

(2) When the optional clasp is used.<br />

(3) The tolerance from the center of ø62 is shown.<br />

(4) The dimensions of the front-face type are shown. Some of the back-face and plug-in types have a different reference plane for mounting the circuit breaker.<br />

(5) The front plate drilling dimensions for the U series differ from those shown above. Please consult us for their details.<br />

● Appearance (Color N1.5)<br />

● 4- 5.5<br />

External dimensions<br />

● Drilling plan<br />

● Indicates the tripping of the breaker even in<br />

ON-lock position--but only in cases when a<br />

single padlock<br />

(35mm or 40mm) is used.<br />

● Degrees of protection (in accordance with<br />

IEC60529): IP5X.<br />

Applicable models<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW, MB30-SW, MB50-CW/SW<br />

S1SW NF125-CW/SW/HW, NV125-CW/SW/HW, MB100-SW, NV125-RW (Note 5)<br />

Clasp<br />

(Note 1)<br />

(Note 2)<br />

Clasp<br />

(option)<br />

45<br />

84<br />

12<br />

*5<br />

Deviation: 2 mm or less<br />

Front panel<br />

Deviation: 5mm or less<br />

110 or more (250 or more if hinge<br />

is mounted on the left)<br />

*3<br />

25 102 ± 5 Front panel applicable thickness : 1.6 to 3.2<br />

– –<br />

70<br />

(Note 3)<br />

43.5±4<br />

A ± 2<br />

B ± 2<br />

47<br />

Fastening<br />

84<br />

4-ø4.5<br />

9<br />

70<br />

Hinge<br />

Center of the circuit<br />

breaker<br />

Deviation<br />

of 4mm<br />

or less<br />

ø12<br />

Front plate deviation of 4mm or less<br />

100 or more (210 or more<br />

when the hinge is on the left)<br />

Front plate thickness 1.2–3.2<br />

Fastening<br />

A±2<br />

B±2<br />

(Note 2) C±2<br />

Hinge<br />

Reference plane for mounting<br />

the circuit breaker<br />

Dimensions (mm)<br />

A (Note 4) B (Note 4) C (Note 4)<br />

87 102 104.5<br />

S2SW<br />

NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW<br />

NV250-SEW/HEW, MB225-SW, NV250-RW (Note 5)<br />

95 110 112.5<br />

S2GSW NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW 113 128 130.5<br />

Remark: (1) Reset open-type<br />

(2) These are not suitable for isolation.<br />

Centre of<br />

breaker<br />

D<br />

(b)<br />

Reference plane<br />

for mounting the breaker<br />

F ig<br />

Dimensions (mm)<br />

Type<br />

Breaker type<br />

External<br />

dimensions<br />

Drilling<br />

plan A✳4 B✳4 C✳4 D<br />

S *5 4CW NF400-CW, NV400-CW a b 140<br />

156<br />

— 0<br />

NF400-SW/SEW/HEW/REW, NV400-SW/SEW/HEW/REW<br />

NF630-CW/SW/SEW/HEW/REW, NV630-CW/SW/SEW/HEW<br />

162<br />

178<br />

— 0<br />

S4SW *5 NF800-CEW/SDW/SEW/HEW/REW, NV800-SEW/HEW a b<br />

NF400-UEW (3P) 259<br />

275<br />

— 20<br />

NF400-UEW (4P), NF800-UEW<br />

259 275<br />

— 23.5<br />

S10SW<br />

NF1000-SEW, NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

a<br />

b<br />

199 215 — 0<br />

Notes: *1. Retainers are not included. They must be provided by the customer.<br />

Remark: (1) Reset open-type<br />

*2. When using optional retainer.<br />

*3. Shows the tolerance for the distance from the center of a 62mm dia. hole.<br />

*4. The figures show the front-connection dimensions. Some rear-connection and plug-in breakers have a different reference surface for mounting purposes.<br />

*5. S4CW and S4SW are for isolation purposes. (Specify OFF lock only.) The tolerance is less than 5mm. It does not conform to isolation purposes, however, if the deviation is more than 2mm.<br />

●Surface plate interlocking fastening (separately available)<br />

Operation<br />

handle series<br />

Type<br />

NF32-SW<br />

NF63-CW/SW/HW<br />

TG-S05SW MB30-SW, MB50-CW/SW<br />

NF125-CW/SW/HW<br />

MB100-SW<br />

TG-S1UW NF125-RGW/UGW<br />

NF160-SW/HW<br />

TG-S2SW NF250-CW/SW/HW<br />

NF250-SEW/HEW,MB225-SW<br />

TG-S2UW NF250-RGW/UGW<br />

S-type<br />

TG-S2GSW<br />

NF125-SGW/HGW<br />

NF160-SGW/HGW<br />

NF250-SGW/HGW<br />

NF-SFW, NF-SJW, NF-HJW<br />

TG-S4CW NF400-CW<br />

NF400-SW/SEW/HEW/REW<br />

TG-S4SW NF630-CW/SW/SEW/HEW/REW<br />

NF800-CEW/SDW/SEW/HEW/REW<br />

TG-S4UW<br />

NF400-UEW (3P)<br />

NF400-UEW (4P), NF800-UEW<br />

TG-S10<br />

NF1000-SEW, NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

Remark: The clamp for surface plate interlock fastener is common to 2P, 3P and 4P.<br />

Breaker type<br />

Dimensions (mm)<br />

MCCB ELCB A B<br />

NV32-SW<br />

NV63-CW/SW/HW<br />

NV125-CW/SW/HW<br />

NV125-RW<br />

NV250-CW/SW/HW<br />

NV250-SEW/HEW<br />

NV250-RW<br />

NV400-CW<br />

NV400-SW/SEW/HEW/REW<br />

NV630-CW/SW/SEW/HEW<br />

NV800-SEW/HEW<br />

67<br />

67<br />

87<br />

67<br />

119<br />

119<br />

119<br />

119<br />

Drilling diagram and referential diagram<br />

Center of<br />

the breaker<br />

A<br />

16<br />

M5 screw<br />

for attaching<br />

the fastening<br />

B<br />

OFF<br />

Center of the<br />

handle of breaker<br />

ON<br />

Breaker<br />

Drilling diagram


4. R-type Operating Handle<br />

● Appearance (Color N1.5)<br />

● Outside Dimension Diagram<br />

A<br />

Handle<br />

B<br />

88<br />

16<br />

88<br />

E<br />

D<br />

C<br />

● This handle in conjunction with the breaker main<br />

enables the isolation function effective.<br />

● OFF-position lock only is available for up to three<br />

commercial padlocks (ø8).<br />

● Equipped with cylinder key (option) prevent<br />

deliberate operation.<br />

● Mounting-hole Drilling Dimension Diagram<br />

Center of the<br />

circuit breaker<br />

operating handle<br />

G<br />

C L<br />

Circuit breaker Center of the<br />

operating handle<br />

Center of the circuit<br />

breaker operating handle<br />

G<br />

Center of the<br />

circuit breaker<br />

C L C L<br />

C L C L<br />

(Note 1)<br />

Center of the circuit<br />

breaker operating handle<br />

Center of the<br />

circuit breaker<br />

G<br />

C L<br />

C L<br />

C L<br />

H<br />

(Note 1)<br />

Table 5-26: Summary of Dimensions<br />

Type name<br />

R1SW<br />

Applicable models<br />

NF125-CW, NF125-SW, NF125-HW<br />

NV125-CW, NV125-SW, NV125-HW<br />

Number<br />

of poles<br />

F<br />

Either M4×0.7<br />

screw or ø5<br />

Center of the<br />

(a) 2, 3-pole<br />

(b) 4-pole<br />

operating handle (c)<br />

F<br />

J<br />

F<br />

Either M4×0.7<br />

screw or ø5<br />

Note 1: The drilling at this position is not required for the models of R2GSW.<br />

3P a 90<br />

4P<br />

Fig<br />

Drilling<br />

plan<br />

b<br />

F<br />

Either M4×0.7<br />

screw or ø5<br />

Dimensions (mm)<br />

A B C D E F G H J<br />

120<br />

130<br />

61 105 142 30 111 —<br />

—<br />

15<br />

5<br />

R1UW NV125-RW<br />

3P c 90<br />

191<br />

61<br />

105<br />

142<br />

30<br />

172<br />

30.5<br />

—<br />

R2SW<br />

NF160-SW, NF160-HW, NF250-CW, NF250-SW, NF250-HW<br />

NV250-CW, NV250-SW, NF250-HW, NV250-SEW<br />

NV250-HEW<br />

2P, 3P<br />

4P<br />

a<br />

b<br />

105<br />

140<br />

165<br />

61<br />

107<br />

144<br />

35<br />

126<br />

—<br />

—<br />

17.5<br />

R2UW<br />

NV250-RW<br />

3P<br />

c<br />

105<br />

240<br />

61<br />

107<br />

144<br />

35<br />

201<br />

37.5<br />

—<br />

R2GSW<br />

NF125-SGW, NF125-HGW, NF160-SGW, NF160-HGW,<br />

NF250-SGW, NF250-HGW<br />

2P, 3P<br />

4P<br />

a<br />

b<br />

105<br />

140<br />

165<br />

79<br />

125<br />

162<br />

35<br />

126<br />

—<br />

—<br />

17.5<br />

R2GUW<br />

NF125-RGW, NF125-UGW, NF250-RGW, NF250-UGW<br />

3P<br />

c<br />

105<br />

240<br />

79<br />

125<br />

162<br />

35<br />

201<br />

37.5<br />

—<br />

✽ Equipped with cylinder key (option) to prevent deliberate operation.<br />

● Can be locked in OFF position only.<br />

Outview External dimensions Drilling plan<br />

Breaker<br />

A<br />

B<br />

K<br />

M6 screw<br />

or 7<br />

Table 5-27<br />

Type<br />

R4SW<br />

R4SWNV<br />

R8SW<br />

(a)<br />

Breaker<br />

type<br />

MCCB<br />

NF400-CW, NF400-SW, NF400-SEW,<br />

D<br />

C<br />

ELCB<br />

NF400-HEW —<br />

NF630-CW, NF630-SW, NF630-SEW,<br />

NF630-HEW<br />

—<br />

NF800-CEW, NF800-SDW, NF800-SEW,<br />

NF800-HEW<br />

NV400-CW, NV400-SW,<br />

NV400-SEW, NV400-HEW<br />

NV630-CW, NV630-SW,<br />

NV630-SEW, NV630-HEW<br />

NV800-SEW, NV800-HEW<br />

E<br />

F<br />

H<br />

J<br />

G<br />

F ig<br />

Dimensions (mm)<br />

Drilling<br />

Outview<br />

A B C D E F G H J K L<br />

plan<br />

a<br />

b<br />

L<br />

(b)<br />

257<br />

128<br />

140<br />

140<br />

25<br />

43<br />

97<br />

174<br />

218<br />

194<br />

44<br />

—<br />

275<br />

128<br />

210<br />

140<br />

25<br />

43<br />

97<br />

174<br />

218<br />

243<br />

70<br />

M<br />

—<br />

58


5. Accessories<br />

External Accessories<br />

Ordering information<br />

V<br />

1)<br />

1<br />

2)<br />

SW<br />

3)<br />

1) V : Operating handle type<br />

2) 1 : Frame size of breaker<br />

3) SW : Series name<br />

4) E : For emergency<br />

5) F : Adjustment type of<br />

depth (For only V-handle)<br />

6) NV : Type of breaker<br />

S<br />

1)<br />

1<br />

2)<br />

SW<br />

3)<br />

1) S : Operating handle type<br />

2) 1 : Frame size of breaker<br />

3) SW : Series name<br />

4) A : Handle lock position<br />

S<br />

1)<br />

10<br />

2)<br />

SW<br />

3)<br />

1) S : Operating handle type<br />

2) 10 : Frame size of breaker<br />

E<br />

4)<br />

A<br />

4)<br />

F<br />

5)<br />

3) SW : Series name SW indicate WSS<br />

NV<br />

6)<br />

V······· Variable-depth handle<br />

R······· Rotary handle<br />

05····· NF32-SW, NF63-CW/SW/HW,<br />

MB30-SW, MB50-CW/SW,<br />

DSN32-SW, DSN63-CW/SW,<br />

NV32-SW, NV63-CW/SW/HW<br />

1······· NF125-CW/SW/HW,<br />

NV125-CW/SW/HW, MB100-SW,<br />

DSN125-CW/SW, NV125-RW<br />

2······· NF160-SW/HW, NF250-CW/SW/HW,<br />

MB225-SW,<br />

NV250-CW/SW/HW/SEW/HEW,<br />

DSN250-CW/SW, NV250-RW<br />

2G···· NF125-SGW/HGW,<br />

NF160-SGW/HGW,<br />

NF250-SGW/HGW, DSN125-SGW,<br />

DSN160-SGW, DSN250-SGW,<br />

NF125-RGW/UGW, NF250-RGW/UGW<br />

4······· NF400-CW/SW/SEW/HEW/REW,<br />

DSN400-CW/SW,<br />

NV400-CW/SW/SEW/HEW/REW<br />

NF630-CW/SW/SEW/HEW/REW,<br />

DSN630-CW/SW,<br />

NV630-CW/SW/SEW/HEW<br />

8······· NF800-CEW/SDW/SEW/HEW/REW,<br />

NV800-SEW/HEW, DSN800-CW/SW<br />

SW indicate WSS C, S and H series<br />

UW indicate WSS U series<br />

Blank······ For general<br />

E············ For emergency<br />

Blank······ Variable type<br />

F············ Fix type<br />

NV·········· NV type for 400A frame<br />

Blank······ The other<br />

05····· NF32-SW, NF63-CW/SW/HW,<br />

MB30-SW, MB50-CW/SW,<br />

DSN32-SW, DSN63-CW/SW,<br />

NV32-SW, NV63-CW/SW/HW<br />

1······· NF125-CW/SW/HW,<br />

NV125-CW/SW/HW, MB100-SW,<br />

DSN125-CW/SW, NV125-RW<br />

2······· NF160-SW/HW, NF250-CW/SW/HW,<br />

MB225-SW,<br />

NV250-CW/SW/HW/SEW/HEW,<br />

DSN250-CW/SW, NV250-RW<br />

2G···· NF125-SGW/HGW,<br />

NF160-SGW/HGW,<br />

NF250-SGW/HGW, DSN125-SGW,<br />

DSN160-SGW, DSN250-SGW<br />

4······· NF400-CW/SW/SEW/HEW/REW,<br />

DSN400-CW/SW,<br />

NV400-CW/SW/SEW/HEW/REW,<br />

NF400-UEW<br />

NF630-CW/SW/SEW/HEW/REW,<br />

DSN630-CW/SW, DSN800-CW/SW,<br />

NF800-CEW/SDW/SEW/HEW/REW,<br />

NV630-CW/SW/SEW/HEW,<br />

NV800-SEW/HEW, NF400-UEW(4P)<br />

NF630-UEW, NF800-UEW<br />

SW indicate WSS C, S and H series<br />

CW indicate WSS 400A frame C series<br />

Blank······ ON/OFF position lock<br />

A············ OFF position lock only<br />

10···········NF1000-SS/SSD, NF1250-SS/SSD,<br />

NF1600-SS/SSD, NF1250-UR<br />

F<br />

1)<br />

1<br />

2)<br />

SW<br />

3)<br />

1) F : Operating handle type<br />

2) 1 : Frame size of breaker<br />

3) SW : Series name<br />

4) A : Handle lock position<br />

5) R : Door open position<br />

6) Y : Mounting direction<br />

7) 2P : Number of poles<br />

8) NV : Type of breaker<br />

F<br />

1)<br />

R<br />

1)<br />

10<br />

2)<br />

1<br />

2)<br />

SW<br />

3)<br />

1) R : Operating handle type<br />

2) 1 : Frame size of breaker<br />

3) SW : Series name<br />

4) NV : Type of breaker<br />

SW<br />

3)<br />

1) F : Operating handle type<br />

2) 10 : Frame size of breaker<br />

3) SW : Series name<br />

4) 4P : Number of poles<br />

A<br />

4)<br />

4P<br />

4)<br />

NV<br />

4)<br />

R<br />

5)<br />

Y<br />

6)<br />

2P<br />

7)<br />

NV<br />

8)<br />

05····· NF32-SW, NF63-CW/SW/HW,<br />

MB30-SW, MB50-CW/SW,<br />

DSN32-SW, DSN63-CW/SW,<br />

NV32-SW, NV63-CW/SW/HW<br />

1······· NF125-CW/SW/HW,<br />

NV125-CW/SW/HW, MB100-SW,<br />

DSN125-CW/SW, NV125-RW<br />

2······· NF160-SW/HW, NF250-CW/SW/HW,<br />

MB225-SW,<br />

NV250-CW/SW/HW/SEW/HEW,<br />

DSN250-CW/SW, NV250-RW<br />

2G···· NF125-SGW/HGW,<br />

NF160-SGW/HGW,<br />

NF250-SGW/HGW, DSN125-SGW,<br />

DSN160-SGW, DSN250-SGW,<br />

NF125-RGW/UGW, NF250-RGW/UGW<br />

4······· NF400-CW/SW/SEW/HEW/REW,<br />

DSN400-CW/SW,<br />

NV400-CW/SW/SEW/HEW/REW,<br />

NF400-UEW<br />

NF630-CW/SW/SEW/HEW/REW,<br />

DSN630-CW/SW,<br />

NV630-CW/SW/SEW/HEW<br />

8······· NF800-CEW/SDW/SEW/HEW/REW,<br />

NV800-SEW/HEW, NF400-UEW(4P),<br />

NF800-UEW, DSN800-CW/SW<br />

SW indicate WSS C, S and H series<br />

UW indicate WSS U series<br />

Blank······ ON/OFF position lock<br />

A············ OFF position lock only<br />

Blank······ OFF position open<br />

R············ RESET position open<br />

Blank······ Vertically type<br />

(ON side of breaker is upper)<br />

Y············ Horizontally type<br />

(ON side of breaker is left)<br />

Z············ Horizontally type<br />

(ON side of breaker is right)<br />

Blank······ 3 pole and 4 pole<br />

2P··········· 2 pole<br />

NV·········· NV type for 400 to 800 A frame<br />

Blank······ The other<br />

10··········· NF1000-SEW, NF1250-SEW/SDW,<br />

NF1600-SEW/SDW<br />

SW indicate WSS<br />

Blank······ 2 pole and 3 pole<br />

4P·········· 4 pole<br />

1······· NF125-CW/SW/HW,<br />

NV125-CW/SW/HW/RW<br />

2······· NF160-SW/HW,NF250-CW/SW/HW,<br />

NV250-CW/SW/SEW/HW/HEW/RW<br />

2G···· NF125-SGW/HGW/RGW/UGW<br />

NF160-SGW/HGW,<br />

NF250-/SGW/HGW/RGW/UGW<br />

4······· NF400-CW/SW/SEW/HEW,<br />

NF630-CW/SW/SEW/HEW,<br />

NV400-CW/SW/SEW/HEW,<br />

NV630-CW/SW/SEW/HEW<br />

8······· NF800-CEW/SDW/SEW/HEW,<br />

NV800-SEW/HEW<br />

SW indicate WSS C, S and H series<br />

UW indicate WSS U series<br />

NV·········· NV type for 400 to 630 A frame<br />

Blank······The other<br />

59


5. Terminal Cover<br />

Table 5-28<br />

Large terminal cover<br />

(TC-L)<br />

Small terminal cover<br />

(TC-S)<br />

Transparent terminal<br />

cover (TTC)<br />

Rear terminal cover<br />

(BTC)<br />

Plug-in terminal cover<br />

(PTC)<br />

Breaker type<br />

A<br />

A<br />

A<br />

A<br />

A<br />

C<br />

C<br />

C<br />

C<br />

B<br />

B<br />

B<br />

B<br />

B<br />

C<br />

NF30-CS, MB30-CS<br />

2P<br />

TCL-03CS2W<br />

(43.5×30.5×25)<br />

TCS-03CS2W<br />

(43.5×30.5×5)<br />

TTC-03CS2<br />

(43.5×30.5×25)<br />

BTC-03CS2W<br />

(43.5×30.5×6.5)<br />

—<br />

NF30-CS, NV30-CS, MB30-CS<br />

3P<br />

TCL-03CS3W<br />

(67×30.5×25)<br />

TCS-03CS3W<br />

(67×30.5×5)<br />

TTC-03CS3<br />

(67×30.5×25)<br />

BTC-03CS3W<br />

(67×30.5×6.5)<br />

—<br />

NF32-SW, NF63-CW/SW/HW<br />

2P<br />

(Note 1)<br />

TCL-05SW2W<br />

(50×65.5×25)<br />

(Note 1)<br />

TCS-05SW2W<br />

(50×65.5×5)<br />

(Note 1)<br />

TTC-05SW2<br />

(50×65.5×25)<br />

BTC-05SW2W<br />

(50×65.5×5)<br />

PTC-05SW2W<br />

(50×65.5×6.5)<br />

NF32-SW, NF63-CW/SW/HW<br />

NV32-SW, NV63-CW/SW/HW, MB30-SW<br />

MB50-CW/SW<br />

NF125-CW/SW/HW<br />

3P<br />

2P<br />

IP20<br />

(Note 2)<br />

TCL-05SW3W<br />

(75×65.5×25)<br />

(Note 1)<br />

TCL-1SW2W<br />

(60×65.5×40)<br />

(Note 2)<br />

TCS-05SW3W<br />

(75×65.5×5)<br />

(Note 1)<br />

TCS-1SW2W<br />

(60×65.5×6.5)<br />

(Note 2)<br />

TTC-05SW3<br />

(75×65.5×25)<br />

(Note 1)<br />

TTC-1SW2<br />

(60×65.5×40)<br />

BTC-05SW3W<br />

(75×65.5×5)<br />

BTC-1SW2W<br />

(60×65.5×6.5)<br />

PTC-05SW3W<br />

(75×65.5×6.5)<br />

PTC-1SW2W<br />

(60×65.5×6.5)<br />

NF125-CW/SW/HW, NV125-CW/SW/HW,<br />

NV125-RW, MB100-SW<br />

3P<br />

(Note 2)<br />

TCL-1SW3W<br />

(90×65.5×40)<br />

(Note 2)<br />

TCS-1SW3W<br />

(90×65.5×6.5)<br />

(Note 2)<br />

TTC-1SW3<br />

(90×65.5×40)<br />

BTC-1SW3W<br />

(90×65.5×6.5)<br />

PTC-1SW3W<br />

(90×65.5×6.5)<br />

NF160-SW/HW, NF250-CW/SW/HW,<br />

NV250-CW/SW/HW, NV250-SEW/HEW, NV250-RW<br />

MB225-SW<br />

2P<br />

3P<br />

(Note 2)<br />

TCL-2SW3W<br />

(105×65.5×40)<br />

(Note 2)<br />

TCS-2SW3W<br />

(105×65.5×6.5)<br />

(Note 2)<br />

TTC-2SW3<br />

(105×65.5×40)<br />

BTC-2SW3W<br />

(105×65.5×6.5)<br />

PTC-2SW3W<br />

(105×65.5×6.5)<br />

NF125-SGW/HGW/RGW/UGW, NF160-SGW/HGW<br />

NF250-SGW/HGW/RGW/UGW<br />

2P<br />

3P<br />

IP40<br />

TCL-2GSW3W<br />

(105×84×40)<br />

TCS-2GSW3W<br />

(105×84×6.5)<br />

TTC-2GSW3<br />

(105×84×40)<br />

BTC-2GSW3W<br />

(105×84×6.5)<br />

PTC-2GSW3W<br />

(105×84×6.5)<br />

Notes: (1) Attach the letter “F” to the end of model designation for models with F-type operating handle. (Those are F-type operating-handle dedicated models,<br />

and screws are used for fixing.)<br />

(2) An F-type operating handle can be installed standardly.<br />

Remarks: (1) Parenthesized numbers denote the outside dimensions (A×B×C in mm).<br />

(2) The terminal cover for a four-pole model can be produced upon request.<br />

Table 5-29<br />

5<br />

Large terminal cover<br />

(TC-L)<br />

Transparent terminal<br />

(TTC)<br />

cover<br />

Rear terminal<br />

(BTC)<br />

cover<br />

Plug-in terminal<br />

(PTC)<br />

cover<br />

Breaker type<br />

A<br />

B<br />

C<br />

Fig.1<br />

A<br />

A<br />

A<br />

A<br />

B<br />

C<br />

Fig.2<br />

B<br />

C<br />

B<br />

C<br />

B<br />

C<br />

NF400-CW/SW/SEW/HEW/REW<br />

NV400-CW/SW/SEW/HEW/REW<br />

NF630-CW/SW/SEW/HEW/REW<br />

NV630-CW/SW/SEW/HEW<br />

2P, 3P<br />

TCL-4SW3<br />

✳3<br />

( 171✕99.<br />

5✕ 110)<br />

Fig. 1<br />

TTC-4SW3<br />

( 171✕104.<br />

5✕ 110)<br />

BTC-4SW3<br />

PTC-4SW3<br />

( 140✕99.<br />

5✕<br />

42)<br />

( 140✕99.<br />

5✕ 42)<br />

NF400-UEW<br />

3P<br />

TCL-4SW3✳1<br />

( 171✕132.5/196.<br />

5✕ 110)<br />

—<br />

BTC-4SW3<br />

✳1<br />

( 140✕132.5/196.<br />

5✕ 42)<br />

—<br />

NF400-SW/SEW/HEW, NV400-SEW/HEW<br />

NF630-SW/SEW/HEW, NV630-SEW<br />

4P<br />

TCL-4SW4<br />

( 240✕104.5✕110)<br />

TTC-4SW4<br />

( 240✕104.<br />

5✕ 110)<br />

BTC-4SW4<br />

✳2<br />

( 185✕97.<br />

5✕ 39)<br />

—<br />

NF800-CEW/SDW/SEW/HEW/REW, NV800-SEW/HEW<br />

2P, 3P<br />

TCL-8SW3<br />

( 224✕103.5✕155)<br />

TTC-8SW3<br />

( 224✕103.<br />

5✕ 155)<br />

BTC-8SW3<br />

✳2<br />

( 210✕97.<br />

5✕ 32)<br />

—<br />

NF800-UEW<br />

3P<br />

TCL-8UW3<br />

✳1<br />

( 220✕146/194.<br />

5✕ 155)<br />

—<br />

BTC-8SW3<br />

✳ 1,<br />

✳2<br />

( 210✕146/194.<br />

5✕ 32)<br />

—<br />

TCL-8SW4<br />

NF800-SEW/HEW 4P<br />

Fig. 2<br />

( 294✕103.5✕155)<br />

TTC-8SW4<br />

( 294✕103.<br />

5✕ 155)<br />

BTC-8SW4<br />

✳2<br />

( 280✕97.<br />

5✕ 32)<br />

—<br />

NF400-UEW, NF800-UEW<br />

4P<br />

TCL-8UW4<br />

✳1<br />

( 290✕146/194.<br />

5✕ 155)<br />

—<br />

BTC-8SW4<br />

✳ 1,<br />

✳2<br />

( 280✕146/194.<br />

5✕ 32)<br />

—<br />

NF1000-SEW<br />

NF1250-SEW/SDW<br />

2P, 3P<br />

TCL-10SW3<br />

( 220✕139✕150)<br />

—<br />

—<br />

—<br />

NF1000-SEW<br />

NF1250-SEW/SDW<br />

4P<br />

TCL-10SW4<br />

( 290✕139✕150)<br />

—<br />

—<br />

—<br />

Remarks:<br />

1. ( ) Shows external dimensions in mm. (A✕B✕ C)<br />

✳ 1. Line side/Load side<br />

✳ 2. These covers can be mounted on plug-in type.<br />

✳ 3. Except for NF400/630-HEW/REW and NV400/630-HEW/REW.<br />

60


5. Accessories<br />

External Accessories<br />

6. Electrical Operation Device<br />

● 250A Frame and less<br />

Table 5-30: Summary of Model Designations<br />

Rated operating<br />

voltage<br />

Applicable models<br />

(Note 1)<br />

NF125-CW(3P)<br />

NF125-SW(3P, 4P)<br />

NF125-HW<br />

NF160-SW/HW<br />

NF250-CW/SW/HW<br />

MB225-SW<br />

NF125-SGW/HGW<br />

NF160-SGW/HGW<br />

NF250-SGW/HGW<br />

NV125-CW/SW/HW NV250-CW/SW/HW NV250-SEW/HEW<br />

24V DC MDSD024-NF1SWE MDSD024-NF2SWE MDSD024-NF2GSWE MDSD024-NV1SWE MDSD024-NV2SWE MDSD024-NVE2SWE<br />

48-60V DC MDSD060-NF1SWE MDSD060-NF2SWE MDSD060-NF2GSWE MDSD060-NV1SWE MDSD060-NV2SWE MDSD060-NVE2SWE<br />

Compatible to 100-240V<br />

AC/100-250V DC<br />

MDSAD240-NF1SWE MDSAD240-NF2SWE MDSAD240-NF2GSWE MDSAD240-NV1SWE MDSAD240-NV2SWE MDSAD240-NVE2SWE<br />

● 400A Frame and more<br />

Table 5-31: Specifications<br />

Rated operating voltage<br />

(Allowable voltage range 85~110%)<br />

Control circuit<br />

voltage<br />

Uc<br />

ON<br />

P1<br />

P2<br />

S1<br />

S2<br />

S4<br />

OFF<br />

(RESET)<br />

ALa<br />

ALc<br />

MDS Module<br />

Breaker alarm switch (AL)<br />

(for small current)<br />

P.S<br />

Power<br />

Supply<br />

X<br />

L2<br />

MDS Base<br />

K1<br />

SW1<br />

K2<br />

K2<br />

K1<br />

K3<br />

M<br />

L1<br />

SW2<br />

This refers to the status in which the circuit breaker<br />

and the electrical operation device is OFF.<br />

K3<br />

K2<br />

K1<br />

K3<br />

P.S<br />

SW1<br />

SW2<br />

M<br />

K1<br />

K2<br />

K3<br />

X<br />

L1<br />

L2<br />

Switching power supply<br />

(except for 24VDC model)<br />

MANUAL/AUTO switch<br />

Limit switch (for spring condition<br />

detection Charge/Discharge)<br />

Motor<br />

Relay(for Charge/OFF operation)<br />

Relay(for motor)<br />

Relay(for motor)<br />

Pumping prevention circuit<br />

Power LED indicator (red)<br />

Trip LED indicator (yellow)<br />

24V DC<br />

Control circuit<br />

voltage<br />

Uc<br />

ON<br />

P.S<br />

SW1<br />

SW2<br />

M<br />

K1<br />

K2<br />

K3<br />

X<br />

48-60VDC<br />

ON action 0.05–0.1<br />

Operating time (s) OFF action<br />

0.6 or less<br />

Charging action<br />

1.2 or less<br />

Power requirement (VA) 150<br />

Note: (1) Place an order of other models in conjunction with the circuit breaker.<br />

Remarks: (1) The standard terminal cover can be used.<br />

(2) Please contact us for details of the outside dimensions.<br />

MDSD024 -NF2SWE MDSD024 -NV2SWE/NVE2SWE<br />

MDSD060 -NF2SWE MDSD060 -NV2SWE/NVE2SWE<br />

MDSAD240-NF2SWE MDSAD240-NV2SWE/NVE2SWE<br />

others<br />

P1<br />

P2<br />

S1<br />

S2<br />

MDS Module<br />

P.S<br />

Power<br />

Supply<br />

X<br />

Switching power supply<br />

(except for 24VDC model)<br />

MANUAL/AUTO switch<br />

Limit switch (for spring condition<br />

detection Charge/Discharge)<br />

Motor<br />

Relay(for Charge/OFF operation)<br />

Relay(for motor)<br />

Relay(for motor)<br />

Pumping prevention circuit<br />

Compatible to<br />

100-240V AC/100-250V DC<br />

MDS Base<br />

K3<br />

M<br />

S4<br />

OFF<br />

K1<br />

(RESET) Breaker is OFF condition and MDS is charge condition<br />

K1<br />

SW1<br />

K2<br />

K2<br />

K1<br />

SW2<br />

K3<br />

K3<br />

K2<br />

Motor-drive type (2)<br />

(MD)<br />

Spring-charged type<br />

(MDS)<br />

Table 5-32<br />

MCCB<br />

type<br />

ELCB<br />

type<br />

NF-C series<br />

NF-S·H series<br />

NF-U, MB series<br />

NV-C series<br />

NV-S·H series<br />

MN series<br />

Electrical operation system<br />

Rated operating voltage (V)<br />

(Allowable voltage range<br />

85~110%)<br />

✳1<br />

NF400-CW NF630-CW NF800-CEW<br />

NF400-SW<br />

NF400-SEW/HEW/REW<br />

NF630-SW<br />

NF630-SEW/HEW/REW<br />

NF800-SEW/HEW/REW<br />

NF400-UEW NF800-UEW<br />

NV400-CW NV630-CW<br />

NV400-SW<br />

NV400-SEW/HEW/REW<br />

NV630-SEW/HEW<br />

NV800-SEW/HEW<br />

—<br />

Motor-drive type (2)<br />

—<br />

NF1000-SEW<br />

NF1250-SEW<br />

NF1250-SDW<br />

NF1600-SEW<br />

NF1600-SDW<br />

—<br />

—<br />

—<br />

—<br />

Motor-drive type (2)<br />

NF400-CW NF630-CW NF800-CEW<br />

NF400-SW<br />

NF400-SEW/HEW/REW<br />

NF630-SW<br />

NF630-SEW/HEW/REW<br />

NF800-SEW/HEW/REW<br />

NF400-UEW NF800-UEW<br />

NV400-CW NV630-CW<br />

NV400-SW<br />

NV400-SEW/HEW/REW<br />

NV630-SEW/HEW<br />

NV800-SEW/HEW<br />

—<br />

Spring-charged type<br />

100/110VDC, 100/110VAC, 200/220VAC<br />

(125VDC, 240VAC)<br />

OFF<br />

ON<br />

OFF<br />

—<br />

NF1000-SEW<br />

NF1250-SEW<br />

NF1250-SDW<br />

NF1600-SEW<br />

NF1600-SDW<br />

—<br />

—<br />

—<br />

—<br />

Spring-charged type<br />

ON<br />

61<br />

Operating<br />

current<br />

( A, rms) ✳2<br />

DC<br />

AC<br />

O perating time (s)<br />

100/110V<br />

100/110V<br />

200/220V<br />

On<br />

0.05<br />

Less than 0.3 (self-holding)<br />

Less than 0.3 (self-holding)<br />

O ff<br />

Less than 3 (self-holding)<br />

R equired transformer capacity<br />

(VA )<br />

400<br />

700<br />

700<br />

700<br />

Endurance voltage (V)<br />

3.0 (8.0)<br />

4.0 (8.0)<br />

2.0 (4.5)<br />

4.0 (8.0)<br />

5.0 (10.0)<br />

3.5 (7.0)<br />

✳ 1. ( ) voltages are special options and might require an external resistor. For details, consult your dealer .<br />

✳ 2. ( ) shows starting currents.<br />

1500<br />

1.0 (3.0)<br />

1.0 (3.0)<br />

0.5 (1.5)<br />

8<br />

10<br />

8<br />

1.0 (3.0)<br />

1.0 (3.0)<br />

0.5 (1.5)<br />

0.07<br />

9<br />

10<br />

8<br />

Less than 3 (self-holding)


General precautions for motor-operated electrical MCCBs<br />

● Motor-operated types have intermittent ratings, and therefore they<br />

should not be operated more than 10 times consecutively (one<br />

on/off counts as an operation).<br />

● The operating voltage should be between 85~110% of the rated<br />

control voltage.<br />

● When the breaker is tripped by trip button or breakdown (i.e.,<br />

overload or short circuit), the breaker will not show that it has been<br />

tripped (except for motor-operated type 1 breakers).<br />

● The dielectric strength of the electrical operating circuits is 1500V.<br />

When performing a dielectric strength test simultaneously with<br />

another device at a voltage over 1500V, the operating circuit<br />

terminal should be disconnected.<br />

Electrically Operated MCCBs and ELCBs<br />

Motor-operated type (2)<br />

● Electrical operation<br />

Forward and reverse motor rotation is changed by ball screw to<br />

switch the breaker ON and OFF (reset).<br />

● Manual operation<br />

The manual operation handle can be used to switch the breaker ON<br />

and OFF directly.<br />

● Cautions during electrical operation<br />

1. In case the UVT operates and a circuit breaker trips if the breaker<br />

has a UVT, the re-closing procedure may differ according to the<br />

state of the breaker before tripping.<br />

When the circuit breaker trips while turned ON..... Reset (OFF) -><br />

Turn ON<br />

When the circuit breaker trips while turned OFF..... Turn ON (idle<br />

tripping) -> Reset (OFF) -> Turn ON<br />

(If it fails to turn ON (idle tripping), please operate Reset (OFF) and<br />

turn ON.)<br />

2. Do not send ON and OFF signals consecutively. An interval of at<br />

least 0.5s is required between each ON and OFF.<br />

3. For models with auto reset capability, resetting after an NFB trip<br />

should be performed after an interval of 0.5s.<br />

Automatic Reset<br />

● If the breaker is an auto reset type, it contains a built-in alarm<br />

switch and the off-control circuit closes when the breaker is tripped.<br />

Since the breaker automatically resets itself after tripping, the<br />

power is easily restored by switching on the breaker again. With a<br />

UVT mounted, however, auto reset may not be possible. In this<br />

case, please consult your dealer.<br />

4. The electrical operating device is equipped with a pumping<br />

prevention circuit. Although it is possible to set the device to OFF<br />

while it is set to ON, it is impossible to return it to ON immediately.<br />

To return to ON, first shut off the ON switch, then set it back to ON.<br />

5. Special care is required during electrical operation because the<br />

manual operation handle moves at high speed. Also be sure to turn<br />

off the circuit power supply when using manual operation.<br />

6. With manual operation, ensure that the handle is fully extended.<br />

Manual operation<br />

Internal structure<br />

5<br />

Control circuit<br />

The dotted line shows an additional connection for the automaticreset<br />

type.<br />

(1) Control circuit 1.<br />

(400,630 and 800AF)<br />

breaker is OFF state<br />

(2) Control circuit 2.<br />

(NF1000-SEW to NF 1600-SEW)<br />

Earth terminal<br />

Earth terminal<br />

(DC-)P2<br />

Operational<br />

power supply<br />

ON<br />

P1<br />

S2<br />

OFF<br />

RESET S4<br />

T1<br />

T2<br />

Y<br />

Y<br />

X<br />

Z<br />

Z<br />

T1<br />

X<br />

Y<br />

X<br />

T1<br />

Y<br />

LS<br />

X<br />

Y<br />

Y<br />

X<br />

Z<br />

M<br />

(DC-)P2<br />

Operational<br />

power supply<br />

P1<br />

ON<br />

S2<br />

OFF<br />

RESET S4<br />

Z<br />

T1<br />

T2<br />

Y<br />

T1<br />

X<br />

Y<br />

X<br />

Y<br />

X<br />

Y<br />

Z<br />

X<br />

Y<br />

Y<br />

X<br />

X<br />

Z<br />

M<br />

LS<br />

Z<br />

ALa<br />

95<br />

T2<br />

ALa<br />

95<br />

T2<br />

M :Motor<br />

X :Relay for ON operation<br />

Y :Relay for OFF operation<br />

Z :Relay for changing Motor polarity<br />

T1 :Timer for antipumping<br />

T2 :Timer for automatic reset<br />

LS :Limit Switch<br />

ALa :Alarm switch for automatic reset (a contact)<br />

62


5. Accessories<br />

External Accessories<br />

Spring-charged type<br />

● Electrical operation<br />

When the ON switch is closed, the coil is excited to release the<br />

latch mechanism and the force of the closing spring turns the<br />

breaker ON instantly.<br />

When the OFF switch is closed, a relay starts the motor which turns<br />

the breaker OFF and charges the spring simultaneously.<br />

● Manual operation<br />

Pressing the ON button will release the latch mechanism and the<br />

force of the closing spring turns the breaker ON instantly.<br />

Pressing the leaf spring, pulling out the manual handle and pumping<br />

it back and forth over 10 times will turn the breaker OFF and charge<br />

the spring at the same time.<br />

● Cautions during electrical operation<br />

Whenever an electrical operation device is to be installed in or<br />

removed from the breaker, the breaker must be tripped and the<br />

device discharged.<br />

Pushing the TRIP button on an MCCB with an electrical-operation<br />

device installed will not trip the breaker in the OFF state. This does<br />

not mean the breaker is faulty.<br />

Switching OFF a breaker with an electrical-operation device<br />

installed will take 3s. If instant opening is required, install an SHT or<br />

UVT to the breaker.<br />

● The breaker contains a built-in pumping-prevention relay.<br />

Internal structure<br />

Control circuit<br />

The dotted line shows an additional connection for the automaticreset<br />

type.<br />

(DC-)<br />

P2<br />

Operational<br />

power supply<br />

Internal connection<br />

Earth terminal<br />

X<br />

M<br />

LS3<br />

CC.....Coil for making<br />

Y.....Relay for pumping prevention<br />

X.....Relay for self-sustaining on OFF side<br />

LS1...Limit switch interlocking with cam<br />

LS2...Limit switch interlocking with cam<br />

LS3...Limit switch interlocking with OFF lock plate<br />

M....Motor<br />

P1<br />

X<br />

X<br />

LS2<br />

ON<br />

OFF<br />

RESET<br />

S2<br />

S4<br />

Y<br />

LS1<br />

Y<br />

Y<br />

CC<br />

Ala<br />

Alarm switch for automatic resetting (contact a)<br />

63


8<br />

8<br />

Dimensions<br />

Front connection<br />

● NF125-CW, NF125-SW, NF125-HW<br />

Insulation barrier<br />

(removable) OFF lock plate Center of the electrically operated<br />

Display hole<br />

(ON/OFF/TRIP)<br />

Manual handle<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply module<br />

M8 screw 24<br />

Circuit breaker<br />

Center of the electrically operated<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

P1P2 S1S2S4<br />

P1P2 S1S2S4<br />

111<br />

130 50<br />

86 45<br />

41<br />

78<br />

39<br />

60<br />

30<br />

86<br />

86<br />

Front plate<br />

90 90<br />

Display hole<br />

90<br />

(Charge/Discharge)<br />

120<br />

25<br />

158<br />

163<br />

61<br />

30 30<br />

M4x0.7 screw<br />

or ø5<br />

3-pole Drilling plan 4-pole<br />

110–111<br />

R1<br />

88<br />

Font-plate cut out<br />

40<br />

80<br />

ø8.5<br />

max. 19<br />

(Conductor thickness<br />

t=5 max.)<br />

Conductor drilling for<br />

direct connection<br />

Remarks:<br />

The 2-pole models are 3-pole models<br />

with the central pole removed.<br />

The three-pole type only is available<br />

for the model NF125-CW, and the<br />

3-pole and 4-pole types only are<br />

available for the model NF125-SW.<br />

● NF160-SW, NF160-HW, NF250-CW, NF250-SW, NF250-HW, MB225-SW<br />

MANUAL/AUTO<br />

switch<br />

Alarm switch AL<br />

(micro loads use)<br />

ON button<br />

OPEN(TRIP)<br />

button<br />

● NF125-SGW, NF125-HGW, NF160-SGW, NF160-HGW, NF250-SGW, NF250-HGW<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

Insulating barrier<br />

(removable)<br />

P1<br />

P2<br />

Insulation barrier<br />

(removable)<br />

P1 P2<br />

70<br />

86<br />

90<br />

105<br />

Electrical operation device<br />

Power supply indicator LED(Red)<br />

OFFlock<br />

plate<br />

S1 S2 S4<br />

70<br />

86<br />

90<br />

105<br />

OFF lock plate<br />

Display hole<br />

(ON/OFF/TRIP)<br />

S1 S2 S4<br />

TRIP indicator<br />

LED(Yellow)<br />

Breaker condition's<br />

indicator<br />

(ON/OFF)<br />

Manual handle<br />

P1<br />

P2<br />

Center of the electrically operated<br />

P1 P2<br />

S1<br />

86<br />

90<br />

S2<br />

35<br />

S4<br />

105<br />

140<br />

S1 S2 S4<br />

35<br />

86<br />

90<br />

105<br />

140<br />

Center of MDS<br />

Control circuit terminal<br />

Mounting screw<br />

(M3 tapping screw)<br />

144<br />

165 100<br />

144<br />

50 165<br />

50<br />

Manual handle<br />

100<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

86 45<br />

37<br />

78<br />

35<br />

Front plate<br />

Display hole<br />

(Charge/Discharge)<br />

Control circuit terminal<br />

(M3.5 screw)<br />

Control circuit<br />

terminal cover<br />

45<br />

86<br />

33<br />

78<br />

31<br />

MDS base<br />

Front panel<br />

MDS Module<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply<br />

M8 bolt (Hex-soket)<br />

module<br />

24<br />

176<br />

181<br />

11.5<br />

Hex.socket head<br />

M8 bolt<br />

15.5<br />

Terminal block<br />

for alarm switch AL<br />

connection<br />

(M4 screw)<br />

(with terminal cover)<br />

158<br />

163<br />

61<br />

79<br />

24<br />

35<br />

3-pole<br />

35 35<br />

3-pole<br />

Breaker<br />

Drilling plan<br />

Circuit breaker<br />

Drilling plan<br />

35<br />

4-pole<br />

4-pole<br />

126<br />

M4X0.7 screw<br />

or 5mm-dia. hole<br />

126<br />

M4x0.7 screw<br />

or ø5<br />

Center of MDS<br />

88<br />

Font-plate cut out<br />

Center of the electrically operated<br />

88<br />

R1<br />

R1<br />

Font-plate cut out<br />

32<br />

80<br />

32<br />

80<br />

ø8.5<br />

10<br />

max. 24<br />

(Bus t max=7)<br />

Bus drilling for<br />

direct connection<br />

ø8.5<br />

10<br />

max. 24<br />

(Conductor thickness<br />

t=7 max.)<br />

Conductor drilling for<br />

direct connection<br />

Note.1.One AL(micro loads use)is used<br />

for the LED display for a trip<br />

indicator check.<br />

2.2-pole breakers are 3-pole<br />

breakers with the central pole<br />

removed.<br />

3.NF250-CW is available in 2-and<br />

3-pole only.<br />

MB225-SW is available in 3-<br />

pole only.<br />

5<br />

● NV125-CW, NV125-SW, NV125-HW<br />

Insulation barrier<br />

(removable)<br />

OFF lock plate Center of the electrically operated<br />

Display hole<br />

(ON/OFF/TRIP)<br />

Manual handle<br />

Operating circuit<br />

terminal board<br />

(M3.5 screw)<br />

Operating circuit<br />

terminal cover<br />

(standard supply)<br />

Power supply<br />

module<br />

M8 screw<br />

24<br />

Circuit breaker<br />

Center of the electrically operated<br />

Automatic/<br />

manual<br />

selection<br />

switch<br />

ON button<br />

Trip button<br />

P1 P2 S1 S2 S4<br />

60<br />

86<br />

90<br />

P1 P2 S1 S2 S4<br />

30<br />

86<br />

90<br />

90<br />

120<br />

111<br />

130 50<br />

86 45<br />

41<br />

78<br />

39<br />

Display hole Front plate<br />

(Charge/Discharge)<br />

Test button<br />

25<br />

158<br />

163<br />

61<br />

30 30<br />

3-pole Drilling plan 4-pole<br />

110–111<br />

M4x0.7 screw<br />

or ø5<br />

88<br />

R1<br />

Font-plate cut out<br />

40<br />

80<br />

ø8.5<br />

max.19<br />

(Conductor thickness<br />

t=5 max.)<br />

Conductor drilling for<br />

direct connection<br />

● NV250-SEW, NV250-HEW<br />

Insulating barrier Electrical operation device<br />

(removable) Power supply indicator LED(Red)<br />

OFFlock TRIP indicator<br />

MANUAL/AUTO plate LED(Yellow)<br />

switch<br />

Breaker condition's<br />

Alarm switch AL<br />

indicator<br />

(micro loads use)<br />

(ON/OFF)<br />

ON button<br />

OPEN(TRIP)<br />

button<br />

P1<br />

P2<br />

S1<br />

70<br />

86<br />

90<br />

105<br />

S2<br />

S4<br />

P1<br />

P2<br />

S1<br />

86<br />

90<br />

S2<br />

35<br />

S4<br />

105<br />

140<br />

Center of MDS<br />

Control circuit terminal<br />

Mounting screw<br />

(M3 tapping screw)<br />

Manual handle<br />

144<br />

165 100<br />

100<br />

Test button<br />

Control circuit terminal<br />

(M3.5 screw)<br />

Control circuit<br />

terminal cover<br />

45<br />

86<br />

33<br />

78<br />

MDS base<br />

31<br />

Front panel<br />

MDS Module<br />

15.5<br />

Terminal block<br />

for alarm switch AL<br />

connection<br />

(M4 screw)<br />

(with terminal cover)<br />

158<br />

163<br />

Hex.socket head<br />

M8 bolt<br />

61<br />

24<br />

35<br />

3-pole<br />

Breaker<br />

Drilling plan<br />

126<br />

35<br />

M4X0.7 screw<br />

or 5mm-dia. hole<br />

4-pole<br />

Center of MDS<br />

R1<br />

88<br />

Font-plate cut out<br />

32<br />

80<br />

ø8.5<br />

10<br />

max. 24<br />

(Bus t max=7)<br />

Bus drilling for<br />

direct connection<br />

Note.1.One AL(micro loads use)is used<br />

for the LED display for a trip<br />

indicator check.<br />

2.4-pole breakers are only<br />

NV250-SEW.<br />

64


5. Accessories<br />

External Accessories<br />

Front connection<br />

● NF400-CW, NF400-SW, NF400-SEW, NF400-HEW, NF400-REW Motor drive type (2)<br />

Center line of electrical operation device<br />

231<br />

Center line of electrical operation Insulating barrier<br />

device and breaker<br />

Breaker<br />

Center line of breaker<br />

110<br />

Conductor thickness t=8 max. 44<br />

Operating circuit terminal<br />

8<br />

block M3.5 screw<br />

Breaker<br />

120<br />

70<br />

257<br />

277<br />

194<br />

44<br />

Trip button<br />

112<br />

140<br />

231<br />

2, 3-pole<br />

Remark: 2 pole models are 3-pole models with the central pole removed.<br />

ø14<br />

M12 bolt<br />

● NF400-UEW (3-pole) Motor drive type (2)<br />

4-pole<br />

16<br />

43<br />

22 28<br />

56<br />

168<br />

185<br />

196<br />

44<br />

94.5<br />

195<br />

255<br />

44<br />

M6<br />

44<br />

tap or ø7<br />

2, 3-pole 4-pole<br />

Drilling plan<br />

Center line of electrical operation device and breaker<br />

Insulating barrier<br />

Conductor thickness t=8 max.<br />

Breaker<br />

Operating circuit terminal block<br />

Center line of breaker<br />

M3.5 screw<br />

Center line of electrical operation device<br />

277<br />

120<br />

70<br />

20<br />

Trip button<br />

44<br />

28<br />

112<br />

140<br />

231<br />

16<br />

43 43<br />

110 297<br />

110<br />

ø14<br />

M12 bolt<br />

Drilling plan<br />

● NV400-CW, NV400-SW, NV400-SEW, NV400-HEW, NV400-REW Motor drive type (2)<br />

257<br />

ø12.5<br />

ø12.5<br />

127.5<br />

78<br />

8<br />

156<br />

ø7<br />

141<br />

191.5<br />

292<br />

352<br />

ø7<br />

47<br />

44<br />

Breaker<br />

234<br />

M6 tap or Ø7<br />

Center line of electrical operation device<br />

231<br />

Center line of electrical operation Insulating barrier<br />

device and breaker<br />

Breaker<br />

Center line of breaker<br />

110<br />

Conductor thickness t=8 max.<br />

Operating circuit terminal<br />

block M3.5 screw<br />

44<br />

8<br />

Breaker<br />

● NF630-CW, NF630-SW, NF630-SEW, NF630-HEW, NF630-REW Motor drive type (2)<br />

Center line of electrical operation device<br />

231<br />

Center line of electrical operation Insulating barrier<br />

device and breaker<br />

Breaker<br />

Center line of breaker<br />

Operating circuit terminal<br />

block M3.5 screw<br />

120<br />

70<br />

257<br />

277<br />

194<br />

120<br />

70<br />

257<br />

277<br />

194<br />

Trip button<br />

44<br />

112<br />

140<br />

231<br />

2, 3-pole<br />

Remark: 2 pole models are 3-pole models with the central pole removed.<br />

ø14<br />

M12 bolt<br />

4-pole<br />

16<br />

43<br />

22 28<br />

56<br />

168<br />

185<br />

196<br />

44<br />

94.5<br />

195<br />

255<br />

44<br />

M6<br />

44<br />

tap or ø7<br />

2, 3-pole 4-pole<br />

Drilling plan<br />

110<br />

Conductor thickness t=8 max.<br />

44<br />

8<br />

Breaker<br />

44<br />

Trip button<br />

112<br />

140<br />

231<br />

2, 3-pole<br />

Remark: 2 pole models are 3-pole models with the central pole removed.<br />

ø14<br />

M12 bolt<br />

4-pole<br />

16<br />

43<br />

22 28<br />

56<br />

168<br />

185<br />

196<br />

44<br />

94.5<br />

195<br />

255<br />

44<br />

M6<br />

44<br />

tap or ø7<br />

2, 3-pole 4-pole<br />

Drilling plan<br />

65


Front connection<br />

● NF400-UEW 4-pole Motor drive type (2)<br />

Center line of electrical<br />

operation device<br />

Insulating barrier<br />

Breaker<br />

Center line of<br />

breaker<br />

35<br />

Center line of breaker<br />

ø14<br />

M12 bolt<br />

16<br />

48<br />

110<br />

Conductor<br />

thickness<br />

t=8 max.<br />

ø14<br />

143<br />

97<br />

6.5<br />

ø7<br />

15<br />

120<br />

70<br />

23.5<br />

Center line of<br />

electrical operation device<br />

322<br />

48<br />

275<br />

ø14<br />

112<br />

ø7<br />

140<br />

290<br />

Trip button<br />

35<br />

70<br />

210<br />

280<br />

231<br />

Neutral pole<br />

Operating circuit<br />

terminal block<br />

M3.5 screw<br />

6.5<br />

141<br />

191.5<br />

292<br />

352<br />

Drilling plan<br />

● NV630-CW, NV630-SW, NV630-SEW, NV630-HEW Motor drive type (2)<br />

Center line of electrical operation<br />

device and breaker<br />

120<br />

70<br />

Trip button<br />

● NF800-CEW, NF800-SDW, NF800-SEW, NF800-HEW, NF800-REW Motor drive type (2)<br />

Center line of electrical operation device<br />

Center line of electrical operation<br />

Insulating barrier<br />

device and breaker<br />

44<br />

Center line of electrical operation device<br />

Insulating barrier<br />

231<br />

112<br />

140<br />

231<br />

3-pole<br />

Breaker<br />

Breaker<br />

Test button<br />

ø14<br />

M12 bolt<br />

22 28<br />

56<br />

168<br />

185<br />

196<br />

4-pole<br />

Center line of breaker<br />

Operating circuit terminal<br />

block M3.5 screw Conductor<br />

thickness<br />

t=12 max.<br />

110<br />

Center line of breaker<br />

16<br />

43 257 110<br />

277<br />

Conductor thickness t=8 max. 44<br />

8<br />

Operating circuit<br />

terminal block M3.5 screw<br />

46<br />

8<br />

94.5<br />

195<br />

255<br />

44<br />

44<br />

3-pole<br />

Breaker<br />

M6<br />

tap or ø7<br />

Breaker<br />

44<br />

Drilling plan<br />

4-pole<br />

5<br />

120<br />

70<br />

275<br />

277<br />

194<br />

243<br />

Trip button<br />

2, 3-pole<br />

4-pole<br />

Remark: 2 pole models are 3-pole models with the central pole removed.<br />

44<br />

140<br />

210<br />

231<br />

35 40<br />

70<br />

210<br />

280<br />

231<br />

● NF800-UEW Motor drive type (2)<br />

Center line of electrical operation<br />

device and breaker<br />

Center line of breaker<br />

Center line of electrical<br />

operation device<br />

32 8<br />

15<br />

87<br />

ø14<br />

M12 bolt<br />

Center line of electrica<br />

Center line of breaker<br />

operation device<br />

40<br />

Insulating barrier<br />

14<br />

Breaker<br />

8 32 15<br />

87<br />

110<br />

Neutral<br />

pole<br />

Conductor thickness<br />

t=8 max.<br />

ø14<br />

46<br />

94.5<br />

195<br />

255<br />

143<br />

64<br />

8<br />

ø7<br />

15<br />

70<br />

M6 tap<br />

70<br />

or ø7<br />

2, 3-pole 4-pole<br />

Drilling plan<br />

Breaker<br />

120<br />

70<br />

23.5<br />

44<br />

277<br />

322<br />

275<br />

ø14<br />

112<br />

ø7<br />

290<br />

290<br />

Trip button<br />

140<br />

210<br />

231<br />

3-pole<br />

ø14<br />

M12 bolt<br />

35<br />

70<br />

210<br />

280<br />

231<br />

4-pole<br />

87<br />

Neutral pole<br />

Operating circuit<br />

terminal block<br />

M3.5 screw<br />

8<br />

143<br />

191.5<br />

292<br />

352<br />

70<br />

M6 tap<br />

140<br />

or ø7<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

66


5. Accessories<br />

External Accessories<br />

Front connection<br />

● NV800-SEW, NV800-HEW Motor drive type (2)<br />

Center line of electrical operation<br />

device and breaker<br />

120<br />

70 110<br />

Trip button<br />

44<br />

14<br />

40<br />

140<br />

210<br />

231<br />

3-pole<br />

Insulating barrier<br />

Breaker<br />

32 8<br />

15<br />

275 87<br />

87<br />

ø14<br />

M12 bolt<br />

Operating circuit<br />

terminal block<br />

M3.5 screw<br />

Test button<br />

Conductor thickness<br />

t=12 max.<br />

● NF1000-SEW, NF1250-SEW, NF1250-SDW Motor drive type (2)<br />

406 110<br />

120<br />

61<br />

280(4-pole)<br />

210(4-pole)<br />

70<br />

277<br />

Center line of<br />

4-pole model<br />

Conductor thickness<br />

t=8×2 max. 55<br />

Insulating barrier<br />

15<br />

Bolt max.<br />

Operating circuit M12×50<br />

terminal block<br />

M3.5 screw<br />

46<br />

8<br />

46<br />

94.5<br />

195<br />

255<br />

Breaker<br />

70<br />

M6 tap<br />

or ø7<br />

3-pole<br />

Drilling plan<br />

Breaker<br />

243<br />

375<br />

80<br />

32 8<br />

15<br />

ø13<br />

M12 bolt<br />

13<br />

44<br />

43<br />

140<br />

210(3-pole)<br />

Neutral pole<br />

Center line of electrical<br />

operation device and<br />

3-pole model<br />

59<br />

140<br />

231<br />

290<br />

● NF1600-SEW, NF1600-SDW Motor drive type (2)<br />

70<br />

70<br />

M8 screw<br />

or ø10<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

(185.5)<br />

60<br />

38<br />

ø11<br />

38 15<br />

(185.5)<br />

Conductor thickness<br />

t=6×width 75 max.<br />

Bolt max.<br />

M10×65<br />

55<br />

20<br />

Breaker<br />

61<br />

120<br />

44<br />

210<br />

203<br />

263<br />

Operating circuit<br />

terminal block<br />

M3.5 screw<br />

Center line of electrical<br />

operation device<br />

115<br />

210<br />

280<br />

35<br />

101.5<br />

304.5<br />

364.5<br />

130 406<br />

Neutral pole<br />

140<br />

231<br />

290<br />

69.5<br />

70<br />

70<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

M8 screw<br />

or ø10<br />

375<br />

67


Rear connection<br />

● NF1600-SEW (3-pole) Motor drive type (2)<br />

Operating circuit terminal block Mounting angle Stud can be rotated 90°<br />

M3.5 screw Connection Conductor thickness<br />

allowance t=6×width 75 max.<br />

15<br />

18.5<br />

20<br />

109<br />

Mounting angle<br />

Breaker<br />

over 160<br />

269<br />

120<br />

61<br />

44<br />

406<br />

ø17.5<br />

ø9.5<br />

38 15<br />

273<br />

under<br />

100<br />

81.5<br />

140 231<br />

125 38<br />

210<br />

290 200<br />

● NF1600-SEW (4-pole) Motor drive type (2)<br />

38<br />

60<br />

36<br />

15<br />

ø11<br />

M10×50 bolt<br />

212<br />

3-pole<br />

70<br />

Drilling plan<br />

M8 tap<br />

or ø10<br />

210<br />

35<br />

Operating circuit<br />

terminal block<br />

M3.5 screw<br />

Mounting angle<br />

Stud can be rotated 90°<br />

Connection<br />

allowance Conductor thickness<br />

15 t=6×width 75 max.<br />

18.5<br />

Mounting angle<br />

Breaker<br />

120<br />

61<br />

44<br />

406<br />

ø17.5<br />

ø9.5<br />

109<br />

20<br />

273<br />

under 100<br />

81.5 over 160<br />

269<br />

Center line of electrical<br />

operation device<br />

70<br />

210<br />

280<br />

20<br />

231<br />

290 125<br />

54 18<br />

ø11<br />

M10×50 bolt<br />

38 18<br />

60<br />

106 106<br />

318<br />

4-pole<br />

38<br />

15<br />

70<br />

M8 tap<br />

or ø10<br />

Drilling plan<br />

5<br />

● NF1600-SDW Motor drive type (2)<br />

Operating circuit terminal block Mounting angle Stud can be rotated 90°<br />

M3.5 screw Connection<br />

allowance<br />

Conductor thickness<br />

t=6×width 75 max.<br />

18.5<br />

15<br />

20<br />

109<br />

Mounting angle<br />

Breaker<br />

over 160<br />

120<br />

61<br />

44<br />

406<br />

ø17.5<br />

36<br />

38 15<br />

38<br />

60<br />

233<br />

over 175<br />

375<br />

140 231<br />

210<br />

290 200<br />

ø9.5<br />

125 38<br />

ø11<br />

15<br />

M10×50 bolt<br />

212<br />

3-pole<br />

70<br />

Drilling plan<br />

M8 tap<br />

or ø10<br />

● NF1600-SDW (4-pole) Motor drive type (2)<br />

210<br />

35<br />

Operating circuit<br />

terminal block<br />

M3.5 screw<br />

Mounting angle Stud is in horizontal direction.<br />

Stud can not be rotated 90°.<br />

Connection<br />

allowance<br />

Conductor thickness<br />

15 t=6×width 75 max.<br />

18.5<br />

Mounting angle<br />

Breaker<br />

120<br />

61<br />

406<br />

109<br />

20<br />

233<br />

over 160<br />

375<br />

ø17.5<br />

ø9.5<br />

44<br />

38<br />

over 175<br />

Center line of electrical<br />

operation device<br />

70<br />

210<br />

280<br />

231<br />

290 125<br />

38 18<br />

60<br />

ø11<br />

M10×50 bolt<br />

106 106<br />

318<br />

4-pole<br />

15<br />

70<br />

M8 tap<br />

or ø10<br />

Drilling plan<br />

68


5. Accessories<br />

External Accessories<br />

7. Mechanical Interlocks (MI)<br />

Table 5-33<br />

● Outside Dimension Diagram<br />

(Front connection, Rear connection, and Plug-in)<br />

33<br />

Number<br />

Panel mouting<br />

Direct mount on<br />

Applicable models<br />

of poles Front connection, Rear connection, Plug-in Dimension A mm circuit breaker<br />

NF32-SW, NF63-CW/SW/HW<br />

2P<br />

47.5<br />

–<br />

MI-05SW3<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW, MB30-SW, MB50-CW/SW 3P –<br />

MI-05SWFB3<br />

NF63-SW/HW 4P MI-05SW4 –<br />

NF125-CW/SW/HW<br />

2P<br />

45<br />

–<br />

MI-05SW3<br />

3P<br />

MI-1SWFB3<br />

NF125-CW/SW/HW, NV125-CW/SW/HW, MB100-SW, NV125-RW<br />

4P<br />

MI-1SW4 –<br />

NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW, NV250-SEW/HEW,<br />

MB225-SW, NV250-RW<br />

NF160-SW/HW, NF250-SW/HW, NV250-SW/HW/SEW/HEW<br />

NF125-SGW/HGW/RGW/UGW, NF160-SGW/HGW, NF250-SGW/HGW/RGW/UGW<br />

NF125-SGW/HGW/UGW, NF160-SGW/HGW, NF250-SGW/HGW/UGW<br />

44<br />

13<br />

70<br />

15<br />

● Front, Rear, Plug-in<br />

22<br />

Stroke<br />

1.5<br />

Center of mechanical<br />

interlock<br />

Center of circuit<br />

breaker<br />

Panel plate thickness<br />

(t1~3.2)<br />

(Gap between the circuit breaker and the panel)<br />

Front, Rear, Plug-in (panel mounting)<br />

● Drilling Dimension Diagram<br />

(Front connection, Rear connection, and Plug-in)<br />

4ø (ø5.5 and ø7.5 countersunk (rear) (Note 1) );<br />

use M5×0.8 flat countersunk head screws to fix.<br />

31<br />

15.5<br />

50<br />

2P<br />

3P<br />

4P<br />

3P<br />

4P<br />

A<br />

120 (Note 2)<br />

63 (Note 3)<br />

MI-05SW3<br />

MI-2SW4<br />

MI-05SW3<br />

MI-2SW4<br />

Machine this part according to<br />

the front plate drilling dimensions<br />

of the main breaker.<br />

Center of mechanical<br />

interlock<br />

Center of circuit<br />

breaker<br />

With two breakers, use a panel-mounted mechanical interlock for one-way only input.<br />

A breaker-mounting mechanical to mount on the breaker main unit can be made to order. Consult your<br />

dealer for more details.<br />

Notes: (1) When the panel plate thickness is<br />

2.3 or more, prepare four holes<br />

(ø5.5 and ø9.5 countersunk (rear)).<br />

(2) These are standard dimensions for<br />

2- and 3-pole models, but can be<br />

altered upon request.<br />

(3) The U series have different<br />

dimensions.<br />

Please contact us for details.<br />

Remarks: (1) Please contact us for outside<br />

dimensions of other models of<br />

different specifications.<br />

(2) These are not isolation-compatible.<br />

Mechanical interlock<br />

–<br />

MI-2SWFB3<br />

–<br />

MI-2GSWFB3<br />

–<br />

Breaker mounting (front)<br />

Type<br />

F G P<br />

MI-4SWFB3<br />

44<br />

194<br />

190<br />

MI-8SWFB3<br />

70<br />

243<br />

260<br />

E<br />

44<br />

70<br />

22<br />

Mechanical<br />

interlock<br />

22(30)<br />

44(55)<br />

70(100)<br />

Mechanical<br />

interlock<br />

Breaker<br />

Breaker<br />

Breaker<br />

B<br />

Mounts to 4-5.5mm-dia hole,<br />

7.5mm-dia countersunk (rear)*2<br />

31<br />

15.5<br />

50<br />

A<br />

Stroke<br />

External dimensions<br />

C<br />

Panel thickness<br />

(t1~3.2mm)<br />

Gap between panel<br />

and breaker<br />

Differs with main<br />

breaker unit drilling plan.<br />

Mechanical<br />

interlock<br />

B<br />

31(40)<br />

15.5(20)<br />

A<br />

Stroke<br />

C<br />

Panel thickness<br />

(t1.6~3.2mm)<br />

1.5<br />

Gap between panel<br />

and breaker<br />

External dimensions<br />

Mounts to 4-5.5mm-dia hole,<br />

7.5mm-dia countersunk (rear)*2<br />

Differs with main<br />

breaker unit drilling plan.<br />

Mechanical<br />

interlock<br />

Breaker<br />

94.5 45<br />

Mechanical terminal mount<br />

P<br />

47.5 Stroke<br />

External dimensions<br />

Breaker<br />

G<br />

D<br />

P<br />

Mechanical interlock<br />

Breaker<br />

50(80)<br />

P<br />

( ) dimension are shown for NF1600-SS·NF1600-SSD<br />

Drilling plan<br />

Drilling plan<br />

Drilling plan(breaker mount)<br />

Fig.1 Fig.2 Fig.3<br />

S1. Above 400AF, use panel thickness t=1.6~3.2mm.<br />

S2. When the panel thickness is greater than t=2.3mm, use 4-5.5mm-dia 9.5mm dia countersunk (rear).<br />

✳1 . Specify<br />

the breaker mounting pitch (P)<br />

✳ 2. No need to specify the panel thickness (t). (Usable panel thickness range: t=1~3.2mm. Above 400AF, use panel thickness t=1.6~3.2mm. )<br />

✳3 . For isolation purposes with 400/630/800AF models, keep the C dimension deviation within<br />

± 1mm.<br />

✳ 4. Enquire for more details .<br />

F<br />

P<br />

F<br />

M6 screws<br />

or 7mm-dia<br />

● Table of Altered Dimensions<br />

Table 5-34<br />

B reaker type<br />

Pitch (P) ✳1<br />

Dimensions (mm)<br />

Breaker mount<br />

(✳4)<br />

MCCB<br />

ELCB<br />

Special<br />

Standard<br />

Standard<br />

Type<br />

Standard<br />

C<br />

t A B D E Fig.<br />

Type<br />

2P<br />

3P<br />

3P<br />

Type<br />

4P<br />

(✳3)<br />

3P<br />

NF400-CW/SW/SEW/HEW/REW NV400-CW/SW/SEW/HEW/REW<br />

190<br />

83.5<br />

MI-4SWFB3<br />

NF630-CW/SW/SEW/HEW/REW NV630-CW/SW/SEW/HEW MI-4SW3<br />

– 210<br />

MI-4SW4<br />

250<br />

47.5<br />

33<br />

– 74<br />

NF400-UEW(3P) – – 190<br />

(✳ 2)<br />

63.<br />

5<br />

–<br />

Fig.1<br />

NF800-CEW/SDW/SEW/HEW/REW NV800-SEW/HEW<br />

220<br />

–<br />

83.5<br />

MI-8SWFB3<br />

MI-8SW3<br />

240 – MI-8SW4 290 47.5 33 – 74<br />

NF400-UEW(4P), NF800-UEW<br />

–<br />

– 220<br />

60<br />

–<br />

NF1000-SEW, NF1250-SEW/SDW<br />

–<br />

M-10SW3 220 – – MI-10SW4 290 47.5 47 37.5 – –<br />

–<br />

2.3<br />

Fig.2<br />

NF1600-SEW/SDW<br />

–<br />

M-16SW3 315 – – MI-16SW4 426 65 54.5<br />

39<br />

– –<br />

–<br />

Fig.<br />

Fig.3<br />

–<br />

–<br />

69


8. Handle Lock Devices and Card Holder<br />

Table 5-35<br />

Description Lock cover (LC) Handle lock (HL) Handle lock (HL-S) (Note 2) OFF Lock with 3 Padlock Card holder<br />

Appearance<br />

NF30-CS, MB30-CS<br />

NF30-CS, NV30-CS, MB30-CS<br />

NF32-SW, NF63-CW/SW/HW<br />

2P<br />

3P<br />

2P<br />

LC-03CS<br />

HL-05FH<br />

(Note 1)<br />

—<br />

HLS-05SW2P<br />

—<br />

NF32-SW, NF63-CW/SW/HW, NV32-SW, NV63-CW/SW/HW<br />

MB30-SW, MB50-CW/SW<br />

3P<br />

LC-05SW<br />

HLF-05SW<br />

HLN-05SW<br />

HLS-05SW<br />

NF63-SW/HW<br />

NF125-CW/SW<br />

NF125-HW<br />

NF125-CW/SW/HW, NV125-CW/SW/HW<br />

MB100-SW, NV125-RW<br />

4P<br />

2P<br />

2P<br />

3P<br />

LC-1SW<br />

HLF-1SW<br />

HLN-1SW<br />

(Note 1)<br />

HLS-1SW2P<br />

HLS-1SW<br />

—<br />

CH-P No.5<br />

NF125-SW/HW, NV125-SW/HW<br />

4P<br />

NF160-SW/HW, NF250-CW/SW/HW, NV250-CW/SW/HW<br />

NV250-SEW/HEW, MB225-SW<br />

NV250-RW<br />

2P<br />

3P<br />

4P<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

(Note 1)<br />

HLS-2SW<br />

NF125-SGW/HGW, NF160-SGW/HGW, NF250-SGW/HGW<br />

NF125-RGW/UGW, NF250-RGW/UGW<br />

3P, 4P LC-2GSW<br />

HLF-2GSW (Note 1)<br />

HLN-2GSW<br />

HLS-2GSW<br />

HLF3-2GSW<br />

Notes: (1) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(2) HL-S types are used for OFF-lock.<br />

Remark: (1) Users are requested to prepare padlocks for HL and HL-S types. (25mm padlock for HL, and 35mm padlock for HL-S.)<br />

Table 5-36<br />

P roduct<br />

H andle (HT)<br />

H andle lock (HL)<br />

Handle lock (HL-S )<br />

Card holder<br />

5<br />

Breaker type<br />

NF400-CW, NV400-CW<br />

NF400-SW/SEW/HEW/REW/UEW<br />

NV400-SW/SEW/HEW/REW<br />

NF630-CW/SW/SEW/HEW/REW<br />

NV630-CW/SW/SEW/HEW<br />

NF400-UEW (3P)<br />

NF400-UEW (4P)<br />

NF800-CEW/SDW/SEW/HEW/REW/UEW<br />

NV800-SEW/HEW<br />

NF1000-SEW<br />

NF1250-SEW/SDW<br />

NF1600-SEW/SDW<br />

HT-4CW<br />

HL-4CW (✳1·2)<br />

HT-4SW<br />

HL-4SW (✳1·2)<br />

HT-10SW<br />

HL (✳1)<br />

HLS-4SW (✳1)<br />

HLS-4UW (✳1)<br />

HLS-8SW (✳1)<br />

HLS-8UW (✳3)<br />

Remarks:<br />

1 . Padlocks for HL and HL-S must be provided by the customer.<br />

✳1. Must be ordered with breaker.<br />

✳2. The HL without padlock can be used as a lock cover (LC).<br />

✳3. Applicable types are NF400-UEW (4P) and NF800-UEW (3P, 4P).<br />

—<br />

CH-P No.3<br />

9. IEC 35mm Rail Mounting Adapters<br />

Table 5-37<br />

Adapter for<br />

IEC 35mm rail<br />

M4×0.7 screw<br />

Adapter for<br />

IEC 35mm rail<br />

Applicable models Number of poles Parts number Outline<br />

NF30-CS, NV30-CS, MB30-CS<br />

2P, 3P<br />

DIN-03CS<br />

Fig.1<br />

3<br />

6<br />

NF32-SW, NF63-CW/SW/HW<br />

NV32-SW, NV63-CW/SW/HW, MB30-SW<br />

MB50-CW/SW<br />

2P<br />

3P<br />

DIN-05SW<br />

Fig.2<br />

CL<br />

35<br />

100<br />

CL<br />

5<br />

CL<br />

35<br />

Fig.1<br />

Mounting hook<br />

for IEC 35mm rail<br />

Fig.2<br />

4<br />

35<br />

NF125-CW/SW<br />

NF125-HW, NV125-CW/SW/HW, MB100-SW<br />

2P<br />

3P<br />

2P<br />

3P<br />

DIN-1SW2<br />

DIN-1SW3<br />

Fig.3<br />

8<br />

1<br />

7<br />

13<br />

Fig.3<br />

70


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers and Motor Breakers<br />

NF30-CS<br />

MB30-CS<br />

Series<br />

Frame size 30<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles 2<br />

3<br />

Rated insulation voltage Ui (V) 500<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

690V<br />

500V<br />

415V<br />

380V<br />

240V<br />

—<br />

—<br />

1.5/1.5<br />

1.5/1.5<br />

2.5/2<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

Standard Attached Parts<br />

(Front connection)<br />

NF30-CS<br />

3, 5, 10, 15, 20, 30<br />

C series<br />

(2), (3.2), 4, (5),<br />

6.3, (8), 10, 16<br />

2 (for single phase)<br />

MB30-CS<br />

Mounting screw: M4×0.7×20 (2pcs)<br />

Small terminal cover 2pcs Only MB30-CS<br />

1.4, 2.5, 4, 7.1,<br />

10, 16, 25, 32<br />

3<br />

Type NF30-CS<br />

■Operating Characteristics<br />

3h<br />

2h<br />

1h<br />

40min<br />

Types<br />

NF30-CS<br />

MB30-CS<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

Operating time<br />

1min<br />

40s<br />

30s<br />

20s<br />

10s<br />

6s<br />

4s<br />

2s<br />

Max.<br />

1s<br />

0.6s<br />

0.4s<br />

Min.<br />

0.2s<br />

0.1s<br />

0.06s<br />

0.04s<br />

0.02s<br />

0.01s<br />

1 1.25<br />

2 3 4 5 7 10 20 30 40 50 70 100<br />

×100% of rated current<br />

■Internal Accessories<br />

■Temperature Characteristics<br />

Left-side<br />

mounting<br />

2-pole<br />

3-pole<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

Lead wire<br />

direction<br />

Operating time<br />

change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

Rated ambient<br />

40<br />

50<br />

60<br />

Remark: (1) Standard lead wire is drawn from side. However, lead wire drawn by load can be<br />

produced upon request.<br />

(2) refer to page 44.<br />

Ambient temperature (°C)<br />

■External Accessories<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Small<br />

Large<br />

Rear<br />

Skeleton<br />

Handle lock<br />

Lock cover<br />

Rail mounting adapters<br />

Terminal cover<br />

(TC-S) TCS-03CS3W (*1)<br />

(TC-L) TCL-03CS3W (*1)<br />

(BTC) BTC-03CS3W (*1)<br />

(TTC) TTC-03CS (*1)<br />

(HL) HL-05FH<br />

(LC) LC03CS<br />

(DIN) DIN-03CS<br />

60<br />

70<br />

70<br />

70<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

71


Front connection<br />

Mtg. hole<br />

M5 screw<br />

14.5<br />

Applicable<br />

wire size:1.6mm-dia.<br />

to 14mm 2<br />

M4 × 0.7 taps or ø5<br />

Breaker<br />

76.5<br />

ø8.5<br />

96<br />

ø5<br />

6<br />

64<br />

54<br />

84<br />

ø5.5<br />

23.5<br />

45<br />

2-pole<br />

47<br />

67.5<br />

3-pole<br />

3<br />

28<br />

49<br />

52<br />

67<br />

10<br />

12.5 (max.)<br />

Bus t max. =3<br />

Bus drilling for<br />

direct connection<br />

23.5<br />

2-pole<br />

3-pole<br />

Drilling plan<br />

Rear connection<br />

3-pole<br />

Mtg plate t max. =3.2<br />

M4 × 0.7 taps<br />

or ø5<br />

Breaker<br />

2-pole<br />

Breaker<br />

R2<br />

18<br />

76.5<br />

45 (min)<br />

38.5<br />

58.5<br />

25 (min)<br />

5<br />

76.5<br />

84<br />

20<br />

23.5<br />

23.5<br />

ø14<br />

20<br />

55<br />

Insulating tube<br />

8<br />

Breaker mtg<br />

M6 screw<br />

M4 × 0.7 screw<br />

2-pole<br />

3-pole<br />

2-pole 3-pole Drilling plan<br />

47<br />

Front-plate cutout<br />

1mm clearance on<br />

each side of handle<br />

IEC Rail Mounting Adapter<br />

35mm IEC-rail adapter<br />

for installation<br />

5<br />

35<br />

100<br />

6<br />

31<br />

4<br />

2-pole<br />

Installation utensil<br />

for 35mm IEC-rail<br />

3-pole<br />

52<br />

55<br />

58<br />

70<br />

72


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers and Motor Breakers<br />

NF32-SW<br />

NF63-SW<br />

MB30-SW<br />

MB50-SW<br />

NF63-CW<br />

NF63-HW<br />

MB50-CW<br />

Type name<br />

Rated current In (Amp.)<br />

2 ∗1 Number of poles 3<br />

Rated insulation voltage Ui (V) 600<br />

IEC 60947-2 AC<br />

690V<br />

500V<br />

440V<br />

–<br />

2.5/1<br />

2.5/1<br />

(Icu/Ics)<br />

400V<br />

230V<br />

5/2<br />

7.5/4<br />

DC 250V 2.5/1 –<br />

Rated short-circuit<br />

braking capacity (kA)<br />

Standard Attached Parts<br />

(Front connection)<br />

NF32-SW<br />

3 4 (5) 6 10<br />

(15) 16 20 25<br />

(30) 32<br />

NF63-CW<br />

3 4 (5) 6 10 (15)<br />

16 20 25 (30) 32<br />

40 50 (60) 63<br />

✽1: Types of DC specifications can be produced upon request.<br />

NF63-SW<br />

3 4 (5) 6 10 (15)<br />

16 20 25 (30) 32<br />

40 50 (60) 63<br />

2 ∗1 3 2 ∗1 3 4<br />

600<br />

–<br />

2.5/1<br />

2.5/1<br />

5/2<br />

7.5/4<br />

600<br />

–<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

15/8<br />

2.5/1 – 7.5/4 –<br />

NF63-HW<br />

10 (15) 16 20<br />

25 (30) 32 40<br />

50 (60) 63<br />

2 ∗1 3 4<br />

690<br />

2.5/1<br />

7.5/4<br />

10/5<br />

10/5<br />

25/13<br />

7.5/4 –<br />

MB30-SW<br />

0.8 1.2 1.4<br />

2 2.5 4 5<br />

7.1 8 10 12<br />

16 25 32<br />

3<br />

500<br />

–<br />

–<br />

2.5/1<br />

5/2<br />

7.5/4<br />

–<br />

MB50-CW<br />

8 10 12<br />

16 25 32<br />

40 45<br />

3<br />

500<br />

–<br />

–<br />

2.5/1<br />

5/2<br />

7.5/4<br />

–<br />

Mounting screw: M4×0.7×55 (2 and 3P: 2pcs, 4P: 4pcs)<br />

(Note)<br />

Insulation barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs)<br />

Note: These are supplied with NF63-SW, NF63-HW, and MB50-SW models.<br />

MB50-SW<br />

0.8 1.2<br />

1.4 2 2.5<br />

4 5 7.1<br />

3<br />

500<br />

–<br />

–<br />

7.5/4<br />

7.5/4<br />

15/8<br />

–<br />

Type NF63-SW<br />

■Operating Characteristics<br />

4h<br />

4h<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

AC use<br />

Types<br />

NF32-SW<br />

NF63-CW NF63-SW NF63-HW<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

DC use<br />

Types<br />

NF32-SW<br />

NF63-CW NF63-SW NF63-HW<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

AC use<br />

Types<br />

MB30-SW<br />

MB50-CW<br />

MB50-SW<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

2s<br />

1s<br />

Min.<br />

2s<br />

1s<br />

Min.<br />

2s<br />

1s<br />

Min.<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.2s<br />

0.2s<br />

0.1s<br />

0.1s<br />

0.1s<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

■Internal Accessories<br />

2-pole<br />

3-pole<br />

Remark: (1) refer to page 44.<br />

×100% of Rated current<br />

0.02s<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Left-side<br />

mounting<br />

AL AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

×100% of Rated current<br />

Breaker handle<br />

Right-side<br />

mounting<br />

0.02s<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of Rated current<br />

■Temperature Characteristics<br />

Operating time<br />

change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

Rated ambient<br />

Ambient temperature (°C)<br />

40<br />

50<br />

60<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

F<br />

S<br />

V<br />

Type name<br />

F05SW (*1)<br />

S05SW<br />

V05SWF<br />

Reference<br />

page<br />

55<br />

57<br />

54<br />

R — —<br />

LC<br />

(*2)<br />

HL<br />

LC-05SW<br />

HLF-05SW<br />

HLN-05SW<br />

HL-S HLS-05SW (*1)<br />

70<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

Ml Ml-05SW3 (*1) 69<br />

Small TC-S TCS-05SW3W (*1)<br />

Large TC-L TCL-05SW3W (*1)<br />

Skeleton TTC TTC-05SW3 (*1)<br />

Rear BTC BTC-05SW3W (*1)<br />

Plug-in PTC PTC-05SW3W (*1)<br />

IEC 35mm rail<br />

mounting adapters<br />

(option)<br />

Reference<br />

page<br />

60<br />

DIN-05SW 70<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

73


Front connection<br />

Mounting hole<br />

Insulation barrier<br />

(removable)<br />

50<br />

M5×0.8 screw<br />

(M6 for 60A and 63A)<br />

24<br />

Applicable<br />

wire size:1.6mm-dia.to 22mm 2<br />

M4×0.7 taps<br />

or 5mm dia.hole<br />

Breaker<br />

111<br />

130<br />

84<br />

50<br />

φ8.5<br />

φ4.5<br />

111<br />

25<br />

Trip button<br />

22<br />

50<br />

25<br />

75<br />

Neutral pole<br />

61<br />

45<br />

φ5.5<br />

(6.5mm-diameter for 60A and 63A)<br />

6<br />

25<br />

25<br />

50<br />

75<br />

100<br />

68<br />

12.5 max.<br />

2-pole<br />

3-pole<br />

4-pole<br />

2-pole<br />

3-pole<br />

4-pole<br />

4<br />

90<br />

72<br />

(Conductor thickness<br />

t=5 max.)<br />

Conductor drilling<br />

for direct connection<br />

Drilling plan<br />

Rear connection<br />

2-pole<br />

4-pole<br />

Mounting panel<br />

t=3.2max<br />

Insulation tube<br />

M4×0.7 taps<br />

or 5mm-dia.hole<br />

Breaker<br />

3-pole<br />

Breaker<br />

8<br />

8<br />

111<br />

111<br />

R1<br />

52<br />

27<br />

min.<br />

M6 screw<br />

50<br />

M4×0.7 screw<br />

for mounting breaker<br />

25<br />

φ14<br />

25<br />

25<br />

50<br />

70<br />

22.5<br />

68<br />

42<br />

25<br />

50<br />

75<br />

72<br />

2-pole<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

1.0mm clearance on each side of<br />

the handle frame.<br />

Front-panel cutout<br />

6<br />

Plug-in<br />

Mounting panel<br />

Plug-in terminal block<br />

M5×0.8<br />

terminal block mounting screw<br />

3<br />

3-pole<br />

80<br />

50<br />

4-pole<br />

105<br />

75<br />

25<br />

Breaker (plug-in terminal block)<br />

5.5 15.5<br />

11<br />

83.5<br />

85<br />

180<br />

111<br />

16.5 max.<br />

7<br />

Center line of<br />

breaker body<br />

54<br />

54 80 54<br />

10<br />

Details of terminal<br />

21<br />

89<br />

30<br />

M6 screw<br />

25<br />

55<br />

2-pole<br />

φ6.5<br />

Conductor drilling<br />

for direct connection<br />

25<br />

57 82<br />

2-pole<br />

3-pole<br />

Cutout and drilling plan<br />

50<br />

107<br />

4-pole<br />

6mm-dia.hole or<br />

or M5×0.8 taps<br />

74


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers and Motor Breakers<br />

NF125-CW<br />

NF125-HW<br />

NF125-SW<br />

MB100-SW<br />

Type name NF125-CW NF125-SW NF125-HW MB100-SW<br />

Rated current In (Amp.)<br />

50 (60) 63 (75)<br />

80 100 125<br />

(15) 16 20 (30)<br />

32 40 50 (60) 63<br />

(75) 80 100 125<br />

(15) 16 20 (30)<br />

32 40 50 (60) 63<br />

(75) 80 100<br />

(12.5) (16) (25)<br />

32 (40) 45 63<br />

71 90 100<br />

Type NF125-SW<br />

Number of poles 2 3 2 3 4 2 3 4<br />

3<br />

Rated insulation voltage Ui (V) 600<br />

690<br />

690<br />

500<br />

AC<br />

690V<br />

500V<br />

440V<br />

–<br />

7.5/4<br />

10/5<br />

8/4<br />

18/9<br />

25/13<br />

10/5<br />

30/15<br />

50/25<br />

–<br />

–<br />

25/13<br />

IEC 60947-2<br />

(Icu/Ics)<br />

400V<br />

230V<br />

10/5<br />

30/15<br />

30/15<br />

50/25<br />

50/25<br />

100/50<br />

30/15<br />

50/25<br />

250V 7.5/4 – 15/8 – 40/20 –<br />

–<br />

DC ∗1 400V – 7.5/4 – 15/8 – 40/20<br />

–<br />

500V –<br />

– 15/8 – 40/20 –<br />

Mounting screw: M4×0.7×55 (2 and 3P: 2pcs, 4P: 4pcs)<br />

Standard Attached Parts<br />

(Front connection)<br />

Rated short-circuit<br />

braking capacity (kA)<br />

(Note)<br />

Insulation barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs)<br />

Note: These are supplied with NF125-SW, NF125-HW, and MB100-SW models.<br />

∗1: When wired as shown at the bottom of page 13, 3-pole models can be used for up to 400 V DC, and<br />

4-pole models for up to 500 V DC.<br />

■Operating Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

Time-delay trip<br />

Tyeps<br />

NF125-CW 50A~100A<br />

NF125-SW 40A~100A<br />

NF125-HW 40A~100A<br />

MB100-SW 40A~100A<br />

Max. (60A~100A)<br />

Max. (40A~50A)<br />

AC<br />

DC<br />

Max. total<br />

breaking<br />

time<br />

Instantaneous trip<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40 50<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

Time-delay trip<br />

Max.<br />

Tyeps<br />

NF125-SW 16A~20A<br />

NF125-HW 16A~20A<br />

MB100-SW 12.5A~25A<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40 506070<br />

AC<br />

DC<br />

Instantaneous trip<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

Tyeps<br />

NF125-CW 125A<br />

NF125-SW 125A<br />

AC<br />

Max.<br />

DC<br />

Max. total<br />

breaking time<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40 50 1 1.25 2 3 4 5 6 7 10 15 20 30 40 50<br />

Min.<br />

Tyeps<br />

MB100-SW 32A<br />

NF125-SW 32A<br />

NF125-HW 32A<br />

Max.<br />

AC<br />

DC<br />

Max. total<br />

breaking<br />

time<br />

×100% of Rated current<br />

×100% of Rated current<br />

Max. total<br />

breaking time<br />

×100% of Rated current ×100% of Rated current<br />

Remark: (1) Only AC characteristics are available for the model MB100-SW.<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

2-pole<br />

3, 4-pole<br />

Remark: (1) refer to page 44.<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

F<br />

S<br />

V<br />

F1SW (*1)<br />

S1SW<br />

V1SW (*2)<br />

55<br />

57<br />

54<br />

R R1SW<br />

LC<br />

Type name<br />

LC-1SW<br />

(*4) HLF-1SW<br />

HL HLN-1SW<br />

HL-S HLS-1SW (*1)(*4)<br />

Reference<br />

page<br />

Ml Ml-05SW3 (*1) 69<br />

Small TC-S TCS-1SW3W (*1)<br />

58 Large TC-L TCL-1SW3W (*1)<br />

Skeleton TTC TTC-1SW3 (*1)<br />

70<br />

Terminal cover<br />

Left-side<br />

mounting<br />

AL<br />

Accessories<br />

Mechanical<br />

interlock<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Operating handle<br />

Right-side<br />

mounting<br />

Type name<br />

Rear BTC BTC-1SW3W (*1)<br />

Pulg-in PTC PTC-1SW3W (*1)<br />

IEC 35mm rail<br />

mounting adapters<br />

Electrical<br />

operation device<br />

60<br />

DIN-1SW3 (*1) 70<br />

MDS-NF1SWE (*3)<br />

Current rating (%)<br />

61<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10<br />

Reference<br />

page<br />

Rated ambient<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) Attach the letter "F" to the end of designation for a fixed type.<br />

(*3) Specify the working voltage. An order should be placed at the same time as an order of circuit breaker main body.<br />

(*4) HLF and HLS types are used for OFF-lock, and HLN types for ON-lock.<br />

75


Front connection<br />

CL<br />

Mounting hole<br />

LC<br />

Insulation barrier<br />

(removable)<br />

LC<br />

50<br />

M8 screw<br />

24<br />

Solderless terminal<br />

for wire size<br />

14~2/0AWG CU/AL<br />

LC<br />

LC<br />

Breaker<br />

LC<br />

LC<br />

112<br />

130<br />

84<br />

50<br />

Wire connection<br />

LC<br />

(*1)110-111<br />

30<br />

Trip<br />

button<br />

22<br />

30<br />

45<br />

φ8.5<br />

30<br />

30<br />

60<br />

60<br />

90<br />

90<br />

120<br />

Neutral<br />

pole<br />

4<br />

61<br />

68<br />

72<br />

19 max.<br />

8<br />

2-pole<br />

3-pole<br />

M4X0.7 taps<br />

or 5mm-dia. hole<br />

4-pole<br />

2-pole<br />

3-pole<br />

4-pole<br />

90<br />

(Conductor thickness<br />

t=5 max.)<br />

Drilling plan<br />

Conductor drilling<br />

for direct connection<br />

Rear connection<br />

Mounting plate<br />

t=3.2 max.<br />

102<br />

52<br />

Mounting base<br />

Stud rotatable<br />

by 90°<br />

4-pole<br />

3-pole<br />

2-pole<br />

LC<br />

CL<br />

Breaker<br />

CL<br />

2-pole<br />

LC<br />

4-pole<br />

3-pole CL<br />

CL<br />

Breaker<br />

CL<br />

15<br />

Connection<br />

allowance<br />

112<br />

8<br />

CL<br />

(*1)110-111<br />

112<br />

LC<br />

R1<br />

R1<br />

16<br />

52<br />

8.5<br />

68<br />

72<br />

2.5<br />

15<br />

54.5<br />

104.5<br />

M8 bolt<br />

2.5<br />

15<br />

5<br />

60<br />

90<br />

Insulation<br />

tube<br />

30<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

2-pole<br />

30<br />

60<br />

3-pole<br />

φ18<br />

Drilling plan<br />

30<br />

30<br />

90<br />

M4×0.7 taps or<br />

5mm-dia. hole<br />

4-pole<br />

57<br />

86<br />

Front-panel cutout<br />

28<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

6<br />

Plug-in<br />

3-pole<br />

4-pole<br />

Mounting plate<br />

Plug-in terminal block<br />

M5×0.8<br />

Terminal block<br />

mounting screw<br />

95<br />

60<br />

125<br />

90<br />

30<br />

CL<br />

Breaker (plug-in terminal block)<br />

LC<br />

LC<br />

5.5<br />

20<br />

LC<br />

11<br />

98<br />

190<br />

134<br />

16.5 max.<br />

12<br />

LC<br />

54<br />

56 94 56<br />

12.5<br />

21<br />

89<br />

30<br />

M8 screw<br />

30<br />

65<br />

φ8.5<br />

30 60<br />

67 97<br />

127<br />

Details of terminal<br />

2-pole<br />

Conductor drilling<br />

for direct connection<br />

2-pole 3-pole<br />

Drilling plan<br />

4-pole<br />

6mm-dia. hole<br />

or M5×0.8 taps<br />

Note: (*1) It can respond to the attachment size of 110 and 111 both sides.<br />

Remark: 2-pole model of NF125-HW are 3-pole model with the central pole removed.<br />

76


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers and Motor Breakers<br />

NF250-CW<br />

NF250-HW<br />

NF160-HW<br />

NF250-SW<br />

NF160-SW<br />

MB225-SW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles 2 3 4 2 3 4 2 3 2 3 4 2 3 4<br />

Rated insulation voltage Ui (V) 690<br />

690<br />

600<br />

690<br />

690<br />

AC<br />

690V<br />

500V<br />

440V<br />

–<br />

15/8<br />

25/13<br />

5/3<br />

30/8<br />

50/13<br />

–<br />

10/5<br />

15/8<br />

–<br />

15/8<br />

25/13<br />

5/3<br />

30/8<br />

50/13<br />

IEC 60947-2<br />

(Icu/Ics)<br />

400V<br />

230V<br />

30/15<br />

50/25<br />

50/13<br />

100/25<br />

18/9<br />

35/18<br />

30/15<br />

50/25<br />

50/13<br />

100/25<br />

250V 15/8 – 40/20 – 10/5 – 15/8 – 40/20 –<br />

DC 400V – 15/8 – – 40/20 – – 10/5 – 15/8 – – 40/20 –<br />

500V – 15/8 – 40/20 –<br />

– 15/8 – 40/20<br />

Rated short-circuit<br />

braking capacity (kA)<br />

Standard Attached Parts<br />

(Front connection)<br />

NF160-SW<br />

NF160-HW<br />

125 150 160 125 150 160<br />

NF250-CW<br />

(100)<br />

125 150 175<br />

200 225 250<br />

NF250-SW<br />

(100)<br />

125 150 175<br />

200 225 250<br />

NF250-HW<br />

125 150 175<br />

200 225 250<br />

Mounting screw: M4×0.7×55 (2 and 3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)<br />

*1: When wired as shown at the bottom of page 13, 3-pole models can be used for up to 400 V DC, and 4-pole models for<br />

up to 500 V DC.<br />

MB225-SW<br />

125 150 175<br />

200 225<br />

3<br />

500<br />

–<br />

–<br />

25/13<br />

30/15<br />

50/25<br />

–<br />

–<br />

–<br />

Type NF250-SW<br />

■Operating Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Types<br />

NF250-CW<br />

NF250-SW<br />

NF250-HW<br />

Max.<br />

MB225-SW<br />

NF160-SW<br />

NF160-HW<br />

■Ambient Compensating Curve<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

Rated ambient<br />

Min.<br />

2s<br />

1s<br />

0.5s<br />

250A AC<br />

Max. total<br />

0.2s<br />

125~225A AC breaking<br />

250A DC<br />

time<br />

0.1s<br />

125~225A DC<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of Rated current<br />

Remark: (1) Only AC characteristics are available for the model MB225-SW.<br />

(2) refer to page 44.<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

AL<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Operating handle<br />

Right-side<br />

mounting<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

F<br />

S<br />

V<br />

R<br />

F2SW<br />

S2SW<br />

V2SW (*3)<br />

R2SW<br />

55<br />

57<br />

54<br />

58<br />

LC<br />

(*4)<br />

HL<br />

HL-S<br />

Type name<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

Reference<br />

page<br />

70<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

Ml Ml-05SW3 (*1) 69<br />

Small TC-S TCS-2SW3W (*1)<br />

Large TC-L TCL-2SW3W (*1)<br />

Skeleton TTC TTC-2SW3 (*1)<br />

Rear BTC BTC-2SW3W (*1)<br />

Plug-in PTC PTC-2SW3W (*1)<br />

Electrical<br />

operation device<br />

MDS-NF2SWE (*2)<br />

Reference<br />

page<br />

60<br />

61<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) Specify the working voltage. An order of MB225-SW should be placed at the same time as an order of circuit breaker main body.<br />

(*3) Attach the letter "F" to the end of designation for a fixed type.<br />

(*4) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

77


Front connection<br />

Mounting hole<br />

Insulating barrier<br />

(removable)<br />

144<br />

165 100<br />

102<br />

M8 bolt<br />

(Hex-soket)<br />

50<br />

24<br />

30<br />

Solderless terminal<br />

for wire size<br />

125 175A 14 95mm 2<br />

200 250A 70 125mm 2<br />

Wire connection<br />

Breaker<br />

126<br />

ø4.5<br />

φ8.5<br />

Trip button<br />

22<br />

70<br />

105<br />

3-pole<br />

35<br />

105<br />

140<br />

4-pole<br />

Neutral<br />

pole<br />

100<br />

φ8.5<br />

45<br />

61<br />

68<br />

4 72<br />

92<br />

23 max.<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

10<br />

35<br />

3-pole<br />

M4×0.7 taps<br />

or φ5<br />

Drilling plan<br />

35<br />

4-pole<br />

Rear connection<br />

4-pole<br />

Mounting plate<br />

t max.=3.2<br />

Insulating<br />

tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

3-pole<br />

Breaker<br />

Connection<br />

allowance<br />

22<br />

20<br />

144<br />

8<br />

126<br />

144<br />

R1<br />

52<br />

68<br />

72<br />

15<br />

71<br />

106<br />

15 φ9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting<br />

screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

taps<br />

or φ5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-plate cutout<br />

32.5<br />

6<br />

Plug-in<br />

4-pole<br />

Mounting plate<br />

Plug-in terminal block<br />

3-pole<br />

Breaker (Terminal block)<br />

200<br />

14<br />

6<br />

28 144<br />

34.5<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

153<br />

54<br />

80 58.5<br />

58.5<br />

18<br />

86<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

derection only<br />

20<br />

70<br />

105<br />

φ9<br />

M8 bolt<br />

Insulating barrier<br />

70<br />

φ7<br />

107<br />

3-pole<br />

Drilling plan<br />

105<br />

142<br />

4-pole<br />

Remarks: 1. 2-pole models are 3-pole models with the central pole removed.<br />

2. Only 2- and 3-pole models are available for the model of NF250-CW, and only 3-pole models are available<br />

for the model of MB225-SW.<br />

78


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF250-SGW<br />

NF160-SGW<br />

NF125-SGW<br />

NF250-HGW<br />

NF160-HGW<br />

NF125-HGW<br />

Type name<br />

Rated current In (Amp.)<br />

Rated short-circuit<br />

braking capacity (kA)<br />

NF125-SGW<br />

RT<br />

16–25, 25–40,<br />

40–63, 63–100,<br />

80–125<br />

NF125-SGW<br />

RE<br />

16–32, 32–63,<br />

63–100, 75–125<br />

NF125-HGW<br />

RT<br />

16–25, 25–40,<br />

40–63, 63–100,<br />

80–125<br />

NF125-HGW<br />

RE<br />

16–32, 32–63,<br />

63–100, 75–125<br />

NF160-SGW<br />

RT<br />

125–160<br />

NF160-SGW<br />

RE<br />

80–160<br />

Number of poles<br />

2 3 4 3 4 2 3 4 3 4 2 3 4 3 4<br />

Rated insulation voltage Ui (V)<br />

690<br />

690<br />

690<br />

690<br />

690<br />

690<br />

690V 8/8<br />

8/8<br />

20/20 20/20<br />

8/8<br />

8/8<br />

500V 30/30 30/30 50/50 50/50 30/30 30/30<br />

AC 440V 36/36 36/36 65/65 65/65 36/36 36/36<br />

IEC<br />

60947-2<br />

(Icu/Ics)<br />

400V<br />

230V<br />

36/36<br />

85/85<br />

36/36<br />

85/85<br />

75/75<br />

100/100<br />

75/75<br />

100/100<br />

36/36<br />

85/85<br />

36/36<br />

85/85<br />

300V 20/20 –<br />

– 40/40 –<br />

– 20/20 –<br />

–<br />

DC ∗1 500V – 20/20 – – – 40/40 – – – 20/20 – –<br />

600V – 20/20 –<br />

– 40/40 –<br />

– 20/20 –<br />

Standard Attached Parts (Front connection) Mounting screw: M4×0.7×73 (4pcs) Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)<br />

Type name<br />

NF160-HGW<br />

RT<br />

NF160-HGW<br />

RE<br />

NF250-SGW<br />

RT<br />

NF250-SGW<br />

RE<br />

NF250-HGW<br />

RT<br />

NF250-HGW<br />

RE<br />

Rated current In (Amp.)<br />

125–160<br />

80–160<br />

125–160,<br />

160–250<br />

125–250<br />

125–160<br />

160–250<br />

125–250<br />

■Operating Characteristics<br />

Operating time<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Min.<br />

Type NF250-SGW<br />

Time-delay trip<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Pre-alarm<br />

pickup current IP<br />

Ir × (0.70-0.75<br />

-0.8-0.85-0.9<br />

-0.95-1.0) ±10%<br />

Pre-alarm<br />

operating time TP<br />

TL<br />

TP= ± 20% 2<br />

(at 200%)<br />

INST pickup current Il<br />

In × (4~14) ±15%<br />

AC<br />

DC<br />

×100% of Rated current<br />

Thermal-Adjustable types<br />

NF125-SGW/HGW 25-40A (Rated current In=40A)<br />

16-25A (Rated current In=25A)<br />

Max.<br />

Instantaneous trip<br />

current ratio<br />

AC DC<br />

x In (%) x In (%)<br />

1000±200 1300±260<br />

Max. total<br />

breaking<br />

time<br />

Instantaneous trip<br />

Electric types<br />

LTD operating time TL<br />

12-60-80-100s ±20%<br />

(at 200%)<br />

NF160-SGW NF160-HGW<br />

Operating time<br />

Note)<br />

Current setting Ir Rated current In<br />

80~160A 160A<br />

(Adjustable)<br />

STD pickup current IS<br />

Ir × (2-2.5-3-3.5-4<br />

-5-6-7-8-10)±15%<br />

Max.total breaking<br />

time<br />

STD operating time TS<br />

0.3±0.06s<br />

0.2±0.04s<br />

0.1±0.03s<br />

0.06±0.02s<br />

0.6 0.7 1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

× 100% of Current setting<br />

Note) Instantaneous tripping current (× 100% of In)<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

690V<br />

500V<br />

690<br />

20/20<br />

50/50<br />

AC 440V 65/65<br />

IEC<br />

60947-2<br />

(Icu/Ics)<br />

400V<br />

230V<br />

75/75<br />

100/100<br />

300V 40/40 –<br />

DC ∗1 500V – 40/40 –<br />

600V – 40/40<br />

Rated short-circuit<br />

braking capacity (kA)<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

×100% of Rated current<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

2 3 4<br />

0.01s<br />

3 4<br />

690<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

–<br />

–<br />

–<br />

×100% of Rated current<br />

2 3 4<br />

690<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

20/20 –<br />

– 20/20 –<br />

– 20/20<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

3 4<br />

690<br />

8/8<br />

30/30<br />

36/36<br />

36/36<br />

85/85<br />

–<br />

–<br />

–<br />

2 3 4<br />

690<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

40/40 –<br />

– 40/40 –<br />

– 40/40<br />

3 4<br />

690<br />

20/20<br />

50/50<br />

65/65<br />

75/75<br />

100/100<br />

–<br />

–<br />

–<br />

Mounting screw: M4×0.7×73 (4pcs) Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)<br />

∗1: Use either 2-pole. When wired as shown at the bottom of page 13, 3-pole models can be used for up to 500 V DC, and 4-pole models for up to 600V DC.<br />

Min.<br />

Time-delay trip<br />

Pre-alarm<br />

pickup current IP<br />

Ir × (0.70-0.75<br />

-0.8-0.85-0.9<br />

-0.95-1.0) ± 10%<br />

Pre-alarm<br />

operating time TP<br />

TP = TL ± 20%<br />

2<br />

(at 200%)<br />

0.6 0.7<br />

Standard Attached Parts (Front connection)<br />

INST pickup current Il<br />

In × (4~14) ± 15%<br />

Thermal-Adjustable types<br />

NF125-SGW/HGW 63-100A (Rated current In=100A)<br />

40-63A (Rated current In=63A)<br />

AC<br />

Max.<br />

1 1.25 2 3 4<br />

DC<br />

Instantaneous trip<br />

current ratio<br />

AC DC<br />

x In (%) x In (%)<br />

1000±200<br />

1300±260<br />

Max. total<br />

breaking<br />

time<br />

Instantaneous trip<br />

Electric types<br />

LTD operating time TL<br />

12-60-80-100s ± 20%<br />

(at 200%)<br />

NF250-SGW NF250-HGW<br />

Note)<br />

Current setting Ir Rated current In<br />

125~250A 250A<br />

(Adjustable)<br />

STD pickup current IS<br />

Ir × (2-2.5-3-3.5-4<br />

-5-6-7-8-10) ± 15%<br />

Max.total breaking<br />

time<br />

STD operating time TS<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

5 6 7 10 15 20 30 40<br />

× 100% of Current setting<br />

Note) Instantaneous tripping current (× 100% of In)<br />

Min.<br />

Time-delay trip<br />

■Ambient Compensating Curve<br />

Current rating (%)<br />

Max.<br />

AC<br />

(Adjustable range)<br />

DC<br />

(Adjustable range)<br />

RT type<br />

Thermal-Adjustable types<br />

NF250-SGW/HGW 160-250A (Rated current In=250A)<br />

NF160-SGW/HGW 125-160A (Rated current In=160A)<br />

NF125-SGW/HGW 80-125A (Rated current In=125A)<br />

Instantaneous trip adjustment<br />

range<br />

Position AC DC<br />

of notch x In (%) x In (%)<br />

4 400±80 520±104<br />

6 600 780<br />

8 800 1040<br />

10 1000±200 1300±260<br />

Instantaneous trip<br />

Max. total<br />

breaking<br />

time<br />

Rated ambient<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Pre-alarm<br />

pickup current IP<br />

Ir × (0.70-0.75<br />

-0.8-0.85-0.9<br />

-0.95-1.0) ± 10%<br />

Pre-alarm<br />

operating time TP<br />

TL<br />

TP= ± 20% 2<br />

(at 200%)<br />

Derating of Load current (%)<br />

INST pickup current Il<br />

In × (4~14) ±15%<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

RE type<br />

70<br />

–10<br />

0<br />

LTD operating time TL<br />

12-60-80-100s ± 20%<br />

(at 200%)<br />

Electric types<br />

NF125-SGW NF125-HGW<br />

Note)<br />

Current setting Ir<br />

16~ 32A<br />

32~ 63A<br />

63~ 100A<br />

75~ 125A<br />

(Adjustable)<br />

STD pickup current IS<br />

Ir × (2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

Max.total breaking<br />

time<br />

Rated ambient<br />

10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

STD operating time TS<br />

0.3±0.06s<br />

0.2±0.04s<br />

0.1±0.03s<br />

0.06±0.02s<br />

0.6 0.7 1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

× 100% of Current setting<br />

Note) Instantaneous tripping current (× 100% of In)<br />

Rated current In<br />

32A<br />

63A<br />

100A<br />

125A<br />

79<br />

■Internal Accessories<br />

Right-side<br />

mounting<br />

SHT or UVT<br />

Operating handle<br />

Left-side<br />

mounting<br />

Remark: (1) refer to page 44.<br />

AL<br />

AX<br />

Lead wire direction<br />

■External Accessories<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

F F2GSW<br />

55 Mechanical<br />

S S2GSW<br />

57 interlock<br />

Operating handle<br />

Ml Ml-05SW3 (*1) 69<br />

V V2GSW (*3) 54<br />

Small TC-S TCS-2GSW3W (*1)<br />

R R2GSW 58 Large TC-L TCL-2GSW3W (*1)<br />

LC LC-2GSW<br />

Skeleton TTC TTC-2GSW3 (*1) 60<br />

Handle lock device<br />

(*2) HLF-2GSW<br />

70<br />

Rear BTC BTC-2GSW3W (*1)<br />

HL HLN-2GSW<br />

Plug-in PTC PTC-2GSW3W (*1)<br />

HL-S HLS-2GSW<br />

OFF Lock with 3 Padlock HLF3-2GSW 70<br />

Electrical MDS-NF2GSWE<br />

operation device<br />

(*4)<br />

61<br />

Terminal cover<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Notes:<br />

(*1) The designation depends<br />

on the number of poles.<br />

Refer to the reference page.<br />

(*2) HLF types are used for<br />

OFF-lock, and HLN types<br />

for ON-lock.<br />

(*3) Attach the letter “F” to the<br />

end of designation for a<br />

fixed type.<br />

(*4) Specify the working voltage.


Front connection<br />

Mounting hole<br />

Insulating barrier<br />

(removable)<br />

M8 bolt<br />

(Hex-soket)<br />

24<br />

Solderless terminal<br />

for wire size<br />

2.5 185mm 2<br />

10<br />

Breaker<br />

Trip<br />

button<br />

22<br />

70<br />

35<br />

105<br />

144<br />

165 50<br />

50<br />

Neutral<br />

pole<br />

112<br />

50<br />

φ8.5<br />

63<br />

79<br />

φ4.5<br />

22<br />

Hex-socket set screw<br />

Wire connection<br />

φ8.5<br />

10<br />

6.1<br />

35<br />

M4×0.7 taps<br />

or φ5<br />

35<br />

126<br />

105<br />

3-pole<br />

140<br />

4-pole<br />

4<br />

86<br />

90<br />

24 max.<br />

(Bus t max.=7)<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

110<br />

Bus drilling for<br />

direct connection<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Connection<br />

allowance<br />

22<br />

20<br />

144<br />

8<br />

126<br />

144<br />

R1<br />

52<br />

86<br />

90<br />

15<br />

71<br />

106<br />

15<br />

φ9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting<br />

screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

φ24<br />

M4×0.7<br />

taps<br />

or φ5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-panel cutout<br />

32.5<br />

6<br />

Plug-in<br />

Plug-in terminal block<br />

4-pole<br />

Breaker (Terminal block)<br />

Mounting plate<br />

15<br />

86<br />

30<br />

45<br />

12<br />

M8 bolt<br />

(Hex-soket)<br />

96<br />

M6<br />

Terminal block<br />

mounting screw<br />

4<br />

120<br />

48 144<br />

54.5<br />

200<br />

103<br />

Stud can be<br />

rotated 90°<br />

Connection<br />

allowance<br />

10 48<br />

20<br />

3-pole<br />

70<br />

110<br />

ø9 M8bolt<br />

Insulating barrier<br />

(removable)<br />

70<br />

φ7<br />

107<br />

3-pole<br />

Drilling plan<br />

105<br />

142<br />

4-pole<br />

66<br />

54 94 54<br />

Remark: 2-pole models are 3-pole models with the central pole removed.<br />

80


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF250-RGW<br />

NF125-RGW<br />

NF250-UGW<br />

NF125-UGW<br />

Type name<br />

Rated current In (Amp.)<br />

NF125-RGW<br />

RT<br />

16–25 25–40<br />

40–63 63–100<br />

NF125-UGW<br />

RT<br />

16–25 25–40<br />

40–63 63–100<br />

NF250-RGW<br />

RT<br />

125–160<br />

160–225<br />

NF250-UGW<br />

RT<br />

125–160<br />

160–225<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated short-circuit<br />

braking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

Standard Attached Parts<br />

(Front connection)<br />

AC<br />

DC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

300V<br />

500V<br />

600V<br />

2<br />

3<br />

2 3 4<br />

2 3 2 3 4<br />

690<br />

25/25<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

–<br />

–<br />

–<br />

690<br />

30/30<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

–<br />

–<br />

–<br />

690<br />

25/25<br />

125/125<br />

125/125<br />

125/125<br />

125/125<br />

–<br />

–<br />

–<br />

690<br />

30/30<br />

200/200<br />

200/200<br />

200/200<br />

200/200<br />

–<br />

–<br />

–<br />

Mounting screw: M4×0.7×73 (4pcs)<br />

Insulation barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)<br />

Type NF250-RGW<br />

■Operating Characteristics<br />

4h<br />

4h<br />

4h<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

Thermal-Adjustable types<br />

NF250-RGW/UGW 160-225A (Rated current In=225A)<br />

125-160A (Rated current In=160A)<br />

Instantaneous trip<br />

adjustment range<br />

Position<br />

of notch<br />

4<br />

6<br />

8<br />

10<br />

AC x In (%)<br />

400±80<br />

600<br />

800<br />

1000±200<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Thermal-Adjustable types<br />

NF125-RGW/UGW 63-100A (Rated current In=100A)<br />

40-63A (Rated current In=63A)<br />

Instantaneous trip<br />

current ratio<br />

AC x In (%)<br />

Max.<br />

1000±200<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Thermal-Adjustable types<br />

NF125-RGW/UGW 25-40A (Rated current In=40A)<br />

16-25A (Rated current In=25A)<br />

Instantaneous trip<br />

current ratio<br />

AC x In (%)<br />

1000±200<br />

Max.<br />

2s<br />

2s<br />

2s<br />

1s<br />

0.5s<br />

AC<br />

(Adjustable range)<br />

1s<br />

0.5s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Max. total<br />

breaking<br />

time<br />

0.2s<br />

0.1s<br />

AC<br />

Max. total<br />

breaking<br />

time<br />

0.2s<br />

0.1s<br />

AC<br />

Max. total<br />

breaking<br />

time<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of Rated current<br />

×100% of Rated current ×100% of Rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

SHT or UVT<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

Remark: (1) refer to page 44.<br />

80<br />

–10<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Mechanical interlock<br />

Electrical operation device<br />

Type name<br />

F —<br />

—<br />

S<br />

V<br />

R<br />

MI<br />

—<br />

V2GUW<br />

R2GUW<br />

MI-05SW3 (*1)<br />

54<br />

58<br />

69<br />

—<br />

Reference<br />

page<br />

—<br />

Terminal cover<br />

Accessories<br />

Small<br />

Large<br />

Skeleton<br />

Rear<br />

Plug-in<br />

Handle lock<br />

device<br />

TC-S<br />

TC-L<br />

TTC<br />

BTC<br />

Type name<br />

TCS-2GSW3W (*1)<br />

TCL-2GSW3W (*1)<br />

TTC-2GSW3 (*1)<br />

BTC-2GSW3W (*1)<br />

PTC PTC-2GSW3W (*1)<br />

LC LC-2GSW<br />

(*2) HLF-2GSW<br />

HL HLN-2GSW<br />

HL-S HLS-2GSW<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) HLF and HLS types are used for OFF-lock, and HLN types for ON-lock.<br />

Reference<br />

page<br />

60<br />

70<br />

81


Front connection<br />

Mounting hole<br />

Insulating barrier<br />

(removable)<br />

26.5<br />

M8 bolt<br />

(Hex-soket)<br />

24<br />

Solderless terminal<br />

for wire size<br />

2.5 185mm 2<br />

10<br />

Breaker<br />

Trip<br />

button<br />

22<br />

70<br />

105<br />

3-pole<br />

35<br />

105<br />

140<br />

4-pole<br />

219<br />

50 240<br />

50<br />

Neutral<br />

pole<br />

75<br />

165<br />

112<br />

50<br />

φ8.5<br />

86<br />

4 90<br />

110<br />

63<br />

79<br />

φ4.5<br />

22<br />

24 max.<br />

φ8.5<br />

10<br />

6.1<br />

Hex-socket set screw<br />

Wire connection<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

35<br />

3-pole<br />

M4×0.7 taps<br />

or φ5<br />

35<br />

Drilling plan<br />

4-pole<br />

201<br />

Rear connection<br />

4-pole<br />

Mounting plate<br />

t max.=3.2<br />

Insulating tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

3-pole<br />

Breaker<br />

73<br />

108<br />

11.5<br />

Connection<br />

allowance<br />

22<br />

20<br />

219<br />

8<br />

201<br />

219<br />

R1<br />

52<br />

15<br />

86 71<br />

90 106<br />

φ9<br />

15 M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting<br />

screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

taps<br />

or φ5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

32.5<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-panel cutout<br />

6<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal<br />

block<br />

Breaker<br />

(Terminal block)<br />

275<br />

14<br />

6<br />

34.5<br />

219<br />

28<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

153<br />

129<br />

58.5 155<br />

58.5<br />

18<br />

104<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

derection only<br />

20<br />

70<br />

φ9 M8bolt<br />

Insulating<br />

barrier<br />

70<br />

107<br />

Drilling plan<br />

φ7<br />

Remark: 2-pole models are 3-pole models with the central pole removed.<br />

82


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF400-CW<br />

NF400-SW<br />

Type NF400-SW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2 AC<br />

(Icu/Ics)<br />

DC(*1)<br />

Standard Attached Parts<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

250V<br />

Front<br />

connection<br />

Rear<br />

connection<br />

NF400-CW<br />

NF400-SW<br />

250 300 350 400<br />

2 3 2 3 4<br />

690<br />

–<br />

15/8<br />

25/13<br />

36/18<br />

50/25<br />

20/10<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

45/45<br />

85/85<br />

40/40<br />

Mounting screw: M6×60 (4pcs)<br />

Insulating barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)<br />

Mounting screw: M6×72 (4pcs)<br />

Note: (*1) When wired as shown at the bottom of page 17, 3-pole models can be<br />

used for up to 400VDC, and 4-pole models for up to 500VDC.<br />

■Operating Characteristics<br />

4h<br />

4h<br />

2h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Type<br />

NF400-CW<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Type<br />

NF400-SW<br />

2min<br />

2min<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

2s<br />

2s<br />

1s<br />

0.5s<br />

AC<br />

1s<br />

0.5s<br />

DC<br />

0.2s<br />

0.1s<br />

0.05s<br />

DC<br />

Max. total<br />

interrupting time<br />

0.2s<br />

0.1s<br />

0.05s<br />

AC<br />

Max.total<br />

interrupting time<br />

0.02s<br />

0.01s<br />

100 125<br />

Time delay trip<br />

Instantaneous trip<br />

200 300 400 500 600700 1000 1500 2000 3000 4000<br />

0.02s<br />

0.01s<br />

100 125<br />

Time delay trip<br />

Instantaneous trip<br />

200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

% of Rated current<br />

% of Rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL<br />

mounting<br />

AX<br />

SHT or UVT<br />

(*1)<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Reference ambient<br />

temperature<br />

(*1) (*1)<br />

(*1)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side mounting.<br />

Remark: (1) refer to page 45.<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

Operating handle<br />

F<br />

S<br />

V<br />

F4SW<br />

S4CW, S4SW<br />

V4SWF, V4SW<br />

Mechanical interlock (MI) MI-4SW3 (*1)<br />

Auxiliary handle<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Type name<br />

(HT) HT-4CW, HT4SW<br />

Reference<br />

page<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Large<br />

Skeleton<br />

Rear<br />

(TC-L) TCL-4SW3 (*1)<br />

(TTC) TTC-4SW3 (*1)<br />

(BTC) BTC-4SW3 (*1)<br />

Handle<br />

lock device<br />

HL<br />

HL-S<br />

HL-4CW, HL-4SW<br />

HLS-4SW<br />

Electrical operation device<br />

Terminal cover<br />

Accessories<br />

Type name<br />

(Reference ambient temperature 40°C)<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

80<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

83


Front connection<br />

110<br />

Insulating barrier (removable)<br />

28<br />

16<br />

43<br />

Conductor thickness<br />

t=8 max.<br />

94.5<br />

8<br />

44<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Mounting hole<br />

Trip button<br />

51<br />

112<br />

140<br />

3-pole<br />

ø14<br />

M12 bolt<br />

56<br />

168<br />

185<br />

196<br />

4-pole<br />

257<br />

Neutral pole<br />

102 39<br />

39<br />

5<br />

ø12.5<br />

ø7<br />

97<br />

103<br />

107<br />

47<br />

44<br />

155 (NF400-SW)<br />

134 (NF400-CW)<br />

25<br />

12<br />

ø10.5<br />

Conductor thickness t=8 max.<br />

Conductor drilling for<br />

direct connection<br />

44 M6 tap or ø7 44<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

194<br />

R6<br />

118<br />

92<br />

1.0mm clearance on each side of the<br />

handle frame.<br />

Front-panel cutout<br />

Rear connection<br />

Boring dimensions for rear connection type<br />

barriers (3-pole)<br />

Mounting plate<br />

Stud can be rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

Groove for reducing<br />

heat by overcurrent<br />

25 20 20<br />

113<br />

10<br />

6<br />

Plug-in<br />

35<br />

8<br />

Line side<br />

6-ø35<br />

8<br />

24<br />

Connection<br />

allowance<br />

M6 tap or ø7<br />

24<br />

4-M6 tap or ø7<br />

225<br />

265<br />

14<br />

194<br />

225<br />

194<br />

225<br />

26<br />

ø13<br />

M12 bolt<br />

128<br />

83<br />

8<br />

87<br />

130.5<br />

M6 screw for<br />

mounting breaker<br />

Insulation tube<br />

44<br />

87<br />

ø35<br />

44<br />

43.5<br />

130.5<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

Load side<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

Plug-in terminal block<br />

Mounting plate<br />

4-pole<br />

3-pole<br />

Breaker<br />

280<br />

18<br />

121<br />

24<br />

M8 terminal block<br />

mounting screw<br />

8<br />

28 225<br />

160<br />

Connection<br />

allowance<br />

79<br />

15<br />

24<br />

ø13<br />

M12 bolt<br />

28<br />

87<br />

130.5<br />

Stud attachable in this<br />

direction only<br />

Insulating barrier<br />

ø10<br />

44<br />

136<br />

3-pole<br />

87<br />

181<br />

4-pole<br />

135<br />

163 55<br />

55<br />

Drilling plan<br />

Remark: (1) 2-pole models are 3-pole models with the central pole removed.<br />

84


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF400-SEW<br />

NF400-HEW<br />

NF400-REW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Reted insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

NF400-SEW NF400-HEW NF400-REW<br />

200-400<br />

adjustable<br />

3 4 3 4<br />

3<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

690<br />

35/18<br />

50/50<br />

65/65<br />

70/70<br />

100/100<br />

690<br />

—<br />

70/35<br />

125/63<br />

125/63<br />

150/75<br />

Type NF400-SEW<br />

Standard Attached Parts<br />

Front<br />

connection<br />

Rear<br />

connection<br />

Mounting screw: M6×72 (4pcs)<br />

Insulating barrier: (3P: 4pcs, 4P: 6pcs)<br />

Mounting screw: M6×85 (4pcs)<br />

■Operating Characteristics<br />

10h<br />

5h<br />

2h<br />

Types<br />

NF400-SEW<br />

NF400-HEW<br />

NF400-REW<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

LTD operating time<br />

at 125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Current setting Rated Current<br />

Ir: 200~400A In: 400A<br />

(Adjustable)<br />

LTD operating time TL<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

Pre-alarm<br />

pickup current Ip<br />

Ir x(0.70-0.75<br />

-0.8-0.85-0.9 ±10%<br />

-0.95-1.0)<br />

12-60-100-150s ±20%<br />

(at 200%)<br />

STD pickup current Is<br />

Ir x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ±20%<br />

2<br />

(at 200%)<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x4~x16 ±15%<br />

(Magnification to In)<br />

Max. total<br />

breaking time<br />

0.6 0.7 1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Current setting (×100% of Ir)<br />

Instantaneous tripping current (×100% of In)<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

Operating handle<br />

Right-side<br />

Lead wire<br />

AL AX SHT or UVT<br />

mounting<br />

direction<br />

PAL TI<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Type name<br />

Operating handle<br />

F<br />

S<br />

V<br />

F4SW<br />

S4SW<br />

V4SWF, V4SW<br />

Mechanical interlock (MI) MI-4SW3 (*2)<br />

Auxiliary handle (HT) HT-4SW<br />

(*1) (*1) (*1)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side mounting.<br />

Remark: (1) refer to page 45.<br />

Reference<br />

page<br />

Notes: (*1) This is for NF400-SEW.<br />

(*2) The designation depends on the number of poles. Refer to the reference page.<br />

55<br />

57<br />

54<br />

69<br />

70<br />

(*1)<br />

Terminal cover<br />

Large<br />

Skeleton<br />

Rear<br />

Handle<br />

lock device<br />

Accessories<br />

Electrical operation<br />

device<br />

Type name<br />

(TC-L) TCL-4SW3 (*1)(*2)<br />

(TTC) TTC-4SW3 (*2)<br />

(BTC) BTC-4SW3 (*1)(*2)<br />

HL HL-4SW<br />

HL-S HLS-4SW<br />

■Temperature Characteristics<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

Continuous load current (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

Rated ambient<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

85


Front connection<br />

110<br />

Insulating barrier (removable)<br />

28<br />

16<br />

43<br />

Conductor thickness<br />

t=8 max.<br />

94.5<br />

8<br />

44<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Mounting hole<br />

Trip button<br />

51<br />

112<br />

140<br />

3-pole<br />

ø14<br />

M12 bolt<br />

56<br />

168<br />

185<br />

196<br />

4-pole<br />

257<br />

Neutral pole<br />

102 39<br />

39<br />

5<br />

59<br />

ø12.5<br />

ø7<br />

44<br />

97<br />

103<br />

107<br />

155<br />

25<br />

12<br />

ø10.5<br />

Conductor thickness t=8 max.<br />

Conductor drilling for<br />

direct connection<br />

44 M6 tap or ø7 44<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

194<br />

R6<br />

118<br />

92<br />

1.0mm clearance on each side of<br />

the handle frame.<br />

Front-panel cutout<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Mounting plate<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

Groove for reducing<br />

heat by overcurrent<br />

25 20 20<br />

113<br />

10<br />

6<br />

Plug-in<br />

35<br />

8<br />

Line side<br />

6-ø35<br />

8<br />

24<br />

Connection<br />

allowance<br />

M6 tap or ø7<br />

24<br />

4-M6 tap or ø7<br />

225<br />

265<br />

14<br />

194<br />

225<br />

194<br />

225<br />

26<br />

ø13<br />

M12 bolt<br />

128<br />

83<br />

8<br />

87<br />

130.5<br />

M6 screw for<br />

mounting breaker<br />

Insulation tube<br />

44<br />

87<br />

ø35<br />

44<br />

43.5<br />

130.5<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

Load side<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

Plug-in terminal block<br />

Mounting plate<br />

4-pole<br />

3-pole<br />

Breaker<br />

280<br />

18<br />

121<br />

24<br />

M8 terminal block<br />

mounting screw<br />

8<br />

28 225<br />

160<br />

Connection<br />

allowance<br />

79<br />

15<br />

24<br />

ø13<br />

M12 bolt<br />

28<br />

87<br />

130.5<br />

Stud attachable in<br />

this direction only<br />

Insulating barrier<br />

ø10<br />

44<br />

136<br />

3-pole<br />

87<br />

181<br />

4-pole<br />

135<br />

163 55<br />

55<br />

Drilling plan<br />

86


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF400-UEW<br />

Type NF400-UEW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

Standard Attached Parts<br />

(4-pole models are provided<br />

with auxiliary handle.)<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

Front<br />

connection<br />

Rear<br />

connection<br />

NF400-UEW<br />

200-400<br />

adjustable<br />

3 4<br />

690<br />

—<br />

170/170<br />

200/200<br />

200/200<br />

200/200<br />

Mounting screw: M6×65 (2pcs), M6×174 (2pcs)<br />

Insulating barrier: (3P: 4pcs)<br />

Mounting screw: M6×72 (2pcs), M6×181 (2pcs)<br />

■Operating Characteristics<br />

10h<br />

Operating time<br />

5h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

pickup current Ip<br />

Ir x(0.70-0.75<br />

-0.8-0.85-0.9 ±10%<br />

-0.95-1.0)<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ±20%<br />

2<br />

(at 200%)<br />

LTD operating time<br />

at 125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Type<br />

NF400-UEW<br />

Current setting Rated Current<br />

Ir: 200~400A In: 400A<br />

(Adjustable)<br />

LTD operating time TL<br />

12-60-100-150s ±20%<br />

(at 200%)<br />

STD pickup current Is<br />

Ir x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x4~x16 ±15%<br />

(Magnification to In)<br />

Max. total<br />

breaking time<br />

0.6 0.7 1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Current setting (×100% of Ir)<br />

Instantaneous tripping current (×100% of In)<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

Operating handle<br />

Right-side<br />

Lead wire<br />

AL AX SHT or UVT<br />

mounting<br />

direction<br />

PAL TI<br />

F F4UW (*1)<br />

Operating handle<br />

S S4SW<br />

Mechanical interlock (MI) MI-4SW3 (*1)<br />

Auxiliary handle (HT) HT-4SW<br />

(*1) (*1) (*1)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side<br />

mounting.<br />

Remark: (1) Specification of 4-pole model is same as that of NF800-UEW.<br />

(2) refer to page 97.<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Type name<br />

Reference<br />

page<br />

Note: (*1)The designation depends on the number of poles. Refer to the reference page.<br />

55<br />

57<br />

69<br />

70<br />

(*1)<br />

Terminal cover<br />

Large<br />

Skeleton<br />

Rear<br />

Handle<br />

lock device<br />

Accessories<br />

Electrical operation<br />

device<br />

Type name<br />

(TC-L) TCL-4SW3 (*1)<br />

(TTC) —<br />

(BTC) BTC-4SW3 (*1)<br />

HL HL-4SW<br />

HL-S HLS-4UW<br />

■Current reducing curve<br />

Reference<br />

page<br />

60<br />

—<br />

60<br />

70<br />

61<br />

Continuous load current (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

Rated ambient<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

87


Front connection<br />

Insulating barrier (removable)<br />

127.5<br />

110<br />

43<br />

Conductor thickness<br />

t=8 max.<br />

78<br />

8<br />

Breaker<br />

Breaker<br />

Mounting hole<br />

Trip button<br />

16<br />

43 297<br />

257<br />

191.5<br />

ø14<br />

51<br />

28<br />

M12 bolt<br />

194<br />

200<br />

112<br />

5 204<br />

140<br />

3-pole<br />

252<br />

102<br />

31<br />

39<br />

ø12.5<br />

ø12.5<br />

ø7<br />

ø7<br />

156<br />

141<br />

47<br />

25<br />

11.5<br />

ø10.5<br />

Conductor thickness t=8 max.<br />

Conductor drilling for direct connection<br />

44<br />

3-pole<br />

Drilling plan<br />

234<br />

M6 tap or ø7<br />

R6<br />

118<br />

26<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

Front-panel cutout<br />

92<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Mounting plate<br />

Stud can be rotated 90°<br />

Breaker<br />

Groove for reducing<br />

heat by overcurrent<br />

Line side<br />

6-ø35<br />

265<br />

8<br />

305<br />

8<br />

234<br />

24<br />

Connection<br />

allowance<br />

M6 screw or ø7<br />

265<br />

234<br />

265<br />

24<br />

4-M6 tap or ø7<br />

25 20 20<br />

26<br />

14<br />

24 24<br />

210<br />

10<br />

ø13<br />

M12 bolt<br />

128<br />

83<br />

8<br />

87<br />

M6 screw for<br />

mounting breaker<br />

Insulation tube<br />

44<br />

87<br />

ø35<br />

11 11<br />

44<br />

87<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

3-pole<br />

Drilling plan<br />

Load side<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

6<br />

Plug-in<br />

Plug-in terminal block<br />

35<br />

Breaker<br />

Mounting angle<br />

320<br />

297<br />

24<br />

18<br />

Mounting angle<br />

M8 terminal block<br />

mounting screw<br />

8<br />

28 265<br />

160<br />

Connection<br />

allowance<br />

79<br />

15<br />

24<br />

28<br />

Stud attachable<br />

in this direction only<br />

ø10<br />

44<br />

175<br />

max. 203<br />

218<br />

3-pole<br />

ø13<br />

M12 bolt<br />

87<br />

Insulating barrier<br />

3-pole<br />

Drilling plan<br />

Note (1): Overall dimension of 4-pole model is same as that of 4-pole model of NF800-UEW. Refer to page 98.<br />

88


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF630-CW<br />

NF630-SW<br />

Type NF630-SW<br />

■Operating Characteristics<br />

4h<br />

2h<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Reted insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

DC(*1)<br />

Standard Attached Parts<br />

(4-pole models are provided<br />

with auxiliary handle.)<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

250V<br />

Front<br />

connection<br />

Rear<br />

connection<br />

NF630-CW<br />

NF630-SW<br />

500 600 630<br />

2 3 2 3 4<br />

690<br />

–<br />

18/9<br />

36/18<br />

36/18<br />

50/25<br />

20/10<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

40/40<br />

Mounting screw: M6×72 (4pcs)<br />

Insulating barrier: (2P: 2pcs, 3P: 4pcs, 4P: 6pcs)<br />

Mounting screw: M6×85 (4pcs)<br />

Note: (*1) When wired as shown at the bottom of page 17, 3-pole models can be used<br />

for up to 400VDC, and 4-pole models for up to 500VDC.<br />

4h<br />

2h<br />

1h<br />

Type<br />

1h<br />

Type<br />

30min<br />

NF630-CW<br />

30min<br />

NF630-SW<br />

20min<br />

14min<br />

10min<br />

20min<br />

14min<br />

10min<br />

6min<br />

6min<br />

4min<br />

4min<br />

2min<br />

2min<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

2s<br />

2s<br />

1s<br />

0.5s<br />

AC<br />

1s<br />

0.5s<br />

DC<br />

0.2s<br />

0.1s<br />

0.05s<br />

DC<br />

Max.total<br />

interrupting time<br />

0.2s<br />

0.1s<br />

0.05s<br />

AC<br />

Max.total<br />

interrupting time<br />

0.02s<br />

0.01s<br />

100 125<br />

Time delay trip<br />

Instantaneous trip<br />

200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

0.02s<br />

0.01s<br />

100 125<br />

Time delay trip<br />

Instantaneous trip<br />

200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

% of Rated current<br />

% of Rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL<br />

mounting<br />

AX<br />

SHT or UVT<br />

(*1)<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Reference ambient<br />

temperature<br />

■External Accessories<br />

(*1) (*1)<br />

(*1)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side mounting.<br />

Remark: (1) refer to page 45.<br />

(An order for should be placed at the same time as an order of circuit breaker main body.)<br />

Accessories Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

F F4SW<br />

55 Large (TC-L) TCL-4SW3 (*1)<br />

Operating handle S S4SW<br />

57 Skeleton (TTC) TTC-4SW3 (*1)<br />

V V4SWF, V4SW 54 Rear (BTC) BTC-4SW3 (*1)<br />

Mechanical interlock (MI) MI-4SW3 (*1) 69 Handle HL HL-4SW<br />

Auxiliary handle (HT) HT-4SW<br />

70<br />

lock device HL-S HLS-4SW<br />

Electrical operation device<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

Terminal cover<br />

80<br />

0 10 20 30 40 50 60<br />

(Reference ambient temperature 40°C)<br />

Ambient temperature (°C)<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

89


Front connection<br />

110<br />

Mounting hole<br />

LC<br />

LC<br />

Insulating barrier<br />

(removable)<br />

LC<br />

28<br />

16<br />

43<br />

257<br />

Bus<br />

t max.=10<br />

39<br />

102<br />

94.5<br />

44<br />

8<br />

59<br />

12<br />

30<br />

ø10.5<br />

Bus t max.=10<br />

Bus drilling for<br />

direct connection<br />

4-pole<br />

3-pole<br />

C L<br />

Breaker<br />

LC C L<br />

LC<br />

R6<br />

Breaker<br />

92<br />

Trip button<br />

ø12.5<br />

ø7<br />

39<br />

LC<br />

194<br />

Neutral pole<br />

44<br />

118<br />

51<br />

112<br />

140<br />

ø14<br />

M12 bolt<br />

56<br />

168<br />

185<br />

196<br />

5<br />

97<br />

103<br />

107<br />

155<br />

44<br />

3-pole<br />

M6 screw<br />

or ø7<br />

44<br />

4-pole<br />

1.0mm clearance on each<br />

side of handle.<br />

Front-plate cutout<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Mounting plate<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

LC<br />

Eddy-current<br />

heat-reducing slit<br />

LC<br />

8<br />

Line side<br />

6-ø35<br />

24<br />

8<br />

24<br />

LC<br />

Connection<br />

allowance<br />

25 20<br />

20<br />

225<br />

265<br />

14<br />

M6 screw<br />

or ø7<br />

LC<br />

194<br />

225<br />

194<br />

225<br />

4-M6 tap<br />

or ø7<br />

280<br />

10<br />

113<br />

Plug-in<br />

Plug-in terminal block<br />

LC<br />

ø13<br />

M12 bolt<br />

Mounting plate<br />

25<br />

10 32<br />

128<br />

M8 terminal block<br />

mounting screw<br />

83<br />

35<br />

225<br />

28<br />

8<br />

87<br />

130.5<br />

Connection allowance<br />

160<br />

93<br />

M6 breaker<br />

mounting screw<br />

Insulating tube<br />

attached to<br />

3P:Center pole<br />

4P:Center &<br />

neutral poles<br />

25<br />

4-pole<br />

3-pole<br />

LC<br />

44<br />

87<br />

3-pole<br />

ø35<br />

Drilling plan<br />

44<br />

43.5<br />

130.5<br />

4-pole<br />

LC<br />

ø10<br />

LC<br />

Breaker<br />

Load side<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped<br />

holes in 8 positions<br />

to standard boring.<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

LC<br />

135<br />

163 55<br />

55<br />

6<br />

18<br />

20<br />

30<br />

Stud attachable in<br />

this direction only<br />

44<br />

87<br />

121<br />

ø13<br />

M12 bolt<br />

110<br />

165.5<br />

Insulating barrier<br />

136<br />

3-pole<br />

181<br />

4-pole<br />

Drilling plan<br />

Remark: (1) 2-pole models are 3-pole models with the central pole removed.<br />

90


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF630-SEW<br />

NF630-HEW<br />

NF630-REW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Reted insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

NF630-SEW NF630-HEW NF630-REW<br />

300-630<br />

adjustable<br />

3 4 3 4<br />

3<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

690<br />

35/18<br />

50/50<br />

65/65<br />

70/70<br />

100/100<br />

690<br />

—<br />

70/35<br />

125/63<br />

125/63<br />

150/75<br />

Type NF630-SEW<br />

Standard Attached Parts<br />

(4-pole models are provided<br />

with auxiliary handle.)<br />

Front<br />

connection<br />

Rear<br />

connection<br />

Mounting screw: M6×72 (4pcs)<br />

Insulating barrier: (3P: 4pcs, 4P: 6pcs)<br />

Mounting screw: M6×85 (4pcs)<br />

■Operating Characteristics<br />

10h<br />

5h<br />

Types<br />

NF630-SEW<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

Pre-alarm<br />

pickup current Ip<br />

Ir x(0.70-0.75<br />

-0.8-0.85-0.9 ±10%<br />

-0.95-1.0)<br />

LTD operating time<br />

at 125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

NF630-HEW<br />

NF630-REW<br />

Current setting Rated Current<br />

Ir: 300~630A In: 630A<br />

(Adjustable)<br />

LTD operating time TL<br />

12-60-100-150s ±20%<br />

(at 200%)<br />

STD pickup current Is<br />

Ir x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

0.5s<br />

0.2s<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ±20%<br />

2<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1s<br />

0.05s<br />

(at 200%)<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x4~x15 ±15%<br />

(Magnification to In)<br />

0.6 0.7 1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Current (×100% of Ir)<br />

Instantaneous tripping current (×100% of In)<br />

Max. total<br />

breaking time<br />

■Internal Accessories<br />

■Temperature Characteristics<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

Lead wire<br />

AL AX SHT or UVT<br />

mounting<br />

direction<br />

PAL TI<br />

(*1)<br />

(*1) (*1) (*1)<br />

Continuous load current (%)<br />

130<br />

120<br />

110<br />

100<br />

Rated ambient<br />

90<br />

80<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side mounting.<br />

Remark: (1) refer to page 45.<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Type name<br />

Operating handle<br />

F<br />

S<br />

V<br />

F4SW<br />

S4SW<br />

V4SWF, V4SW<br />

Mechanical interlock (MI) MI-4SW3 (*1)<br />

Auxiliary handle (HT) HT-4SW<br />

Reference<br />

page<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Terminal cover<br />

Large<br />

Skeleton<br />

Rear<br />

Handle<br />

lock device<br />

Accessories<br />

Electrical operation<br />

device<br />

Type name<br />

(TC-L) TCL-4SW3 (*1)<br />

(TTC) TTC-4SW3 (*1)<br />

(BTC) BTC-4SW3 (*1)<br />

HL HL-4SW<br />

HL-S HLS-4SW<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

91


Front connection<br />

110<br />

Mounting hole<br />

LC<br />

LC<br />

Insulating barrier<br />

(removable)<br />

LC<br />

28<br />

16<br />

43<br />

257<br />

Bus<br />

t max.=10<br />

39<br />

102<br />

94.5<br />

44<br />

8<br />

59<br />

12<br />

30<br />

ø10.5<br />

Bus t max.=10<br />

Bus drilling for<br />

direct connection<br />

4-pole<br />

3-pole<br />

C L<br />

Breaker<br />

LC C L<br />

LC<br />

R6<br />

Breaker<br />

92<br />

Trip button<br />

ø12.5<br />

ø7<br />

39<br />

LC<br />

194<br />

Neutral pole<br />

44<br />

118<br />

51<br />

112<br />

140<br />

ø14<br />

M12 bolt<br />

56<br />

168<br />

185<br />

196<br />

5<br />

97<br />

103<br />

107<br />

155<br />

44<br />

3-pole<br />

M6 screw<br />

or ø7<br />

44<br />

4-pole<br />

1.0mm clearance on each<br />

side of handle.<br />

Front-plate cutout<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Mounting plate<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

LC<br />

Eddy-current<br />

heat-reducing slit<br />

LC<br />

8<br />

Line side<br />

6-ø35<br />

24<br />

8<br />

24<br />

LC<br />

Connection<br />

allowance<br />

25 20<br />

20<br />

225<br />

265<br />

14<br />

M6 screw<br />

or ø7<br />

LC<br />

194<br />

225<br />

194<br />

225<br />

4-M6 tap<br />

or ø7<br />

280<br />

10<br />

113<br />

Plug-in<br />

Plug-in terminal block<br />

LC<br />

ø13<br />

M12 bolt<br />

Mounting plate<br />

25<br />

10 32<br />

128<br />

M8 terminal block<br />

mounting screw<br />

83<br />

35<br />

225<br />

28<br />

8<br />

87<br />

130.5<br />

Connection allowance<br />

160<br />

93<br />

M6 breaker<br />

mounting screw<br />

Insulating tube<br />

attached to<br />

3P:Center pole<br />

4P:Center &<br />

neutral poles<br />

25<br />

4-pole<br />

3-pole<br />

LC<br />

44<br />

87<br />

3-pole<br />

ø35<br />

Drilling plan<br />

44<br />

43.5<br />

130.5<br />

4-pole<br />

LC<br />

ø10<br />

LC<br />

Breaker<br />

Load side<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped<br />

holes in 8 positions<br />

to standard boring.<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

LC<br />

135<br />

163 55<br />

55<br />

6<br />

18<br />

20<br />

30<br />

Stud attachable in<br />

this direction only<br />

44<br />

87<br />

121<br />

ø13<br />

M12 bolt<br />

110<br />

165.5<br />

Insulating barrier<br />

136<br />

3-pole<br />

181<br />

4-pole<br />

Drilling plan<br />

92


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF800-CEW<br />

NF800-SEW<br />

NF800-HEW<br />

NF800-REW<br />

Type NF800-SEW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

Standard Attached Parts<br />

(4-pole models are provided<br />

with auxiliary handle.)<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

Front<br />

connection<br />

Rear<br />

connection<br />

NF800-CEW NF800-SEW NF800-HEW NF800-REW<br />

400-800<br />

adjustable<br />

3 3 4 3 4 3<br />

690<br />

—<br />

18/9<br />

36/18<br />

36/18<br />

50/25<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

50/50<br />

85/85<br />

690<br />

15/15<br />

50/50<br />

65/65<br />

70/70<br />

100/100<br />

690<br />

—<br />

70/35<br />

125/63<br />

125/63<br />

150/75<br />

Mounting screw: M6×35 (4pcs)<br />

Insulating barrier: (3P: 2pcs, 4P: 3pcs)<br />

Mounting screw: M6×40 (4pcs)<br />

■Operating Characteristics<br />

Operating time<br />

10h<br />

5h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

pickup current Ip<br />

Ir x(0.70-0.75<br />

-0.8-0.85-0.9 ±10%<br />

-0.95-1.0)<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ±20%<br />

2<br />

(at 200%)<br />

LTD operating time<br />

at 125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Current setting<br />

Ir: 400~800A<br />

(Adjustable)<br />

Types<br />

NF800-CEW<br />

NF800-SEW<br />

NF800-HEW<br />

NF800-REW<br />

Rated Current<br />

In: 800A<br />

LTD operating time TL<br />

12-60-100-150s ±20%<br />

(at 200%)<br />

STD pickup current Is<br />

Ir x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x4~x12 ±15%<br />

(Magnification to In)<br />

Max. total<br />

breaking time<br />

0.6 0.7 1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Current (×100% of Ir)<br />

Instantaneous tripping current (×100% of In)<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

(*1)<br />

Operating handle<br />

Right-side<br />

Lead wire<br />

AL AX SHT or UVT<br />

mounting<br />

direction<br />

PAL TI<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side mounting.<br />

Remark: (1) refer to page 45.<br />

■External Accessories<br />

(*1) (*1)<br />

(An order for should be placed at the same time as an order of circuit breaker main body.)<br />

Accessories Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

F F8SW<br />

55 Large (TC-L) TCL-8SW3 (*1)<br />

Operating handle S S4SW<br />

57 Skeleton (TTC) TTC-8SW3 (*1)<br />

V V8SWF, V8SW 54 Rear (BTC) BTC-8SW3 (*1)<br />

Mechanical interlock (MI) MI-8SW3 (*1) 69 Handle HL HL-4SW<br />

Auxiliary handle (HT) HT-4SW<br />

70<br />

lock device HL-S HLS-8SW<br />

Electrical operation device<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

Terminal cover<br />

(*1)<br />

■Current Reducing Curve<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

Working current correcting ratio (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

Reference<br />

ambient<br />

temperature<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

The rated current does not<br />

depend on temperature.<br />

However, if ambient<br />

temperature exceeds 40°C,<br />

reduce the continuous<br />

working current as left<br />

curve.<br />

93


Front connection<br />

Mounting hole<br />

Insulating barrier (removable)<br />

Conductor thickness<br />

t=12 max.<br />

94.5<br />

46<br />

26<br />

4-pole<br />

110<br />

32<br />

87<br />

275<br />

Auxiliary handle<br />

(removable)<br />

102<br />

8<br />

15<br />

Terminal dimension for<br />

directly connecting<br />

conductor<br />

Breaker<br />

243<br />

R6<br />

3-pole<br />

Breake<br />

92<br />

32<br />

N<br />

8<br />

ø8<br />

ø8.5<br />

Trip button<br />

14<br />

51<br />

70<br />

40<br />

210<br />

140<br />

210 280<br />

3-pole<br />

4-pole<br />

32<br />

15<br />

87<br />

Neutral pole<br />

ø14<br />

M12 bolt<br />

ø14<br />

5<br />

97<br />

103<br />

107<br />

155<br />

217<br />

8<br />

46<br />

40<br />

22<br />

12<br />

(Conductor thickness t=10 max.) 3-pole<br />

Conductor drilling for direct connection<br />

70 M6 tap<br />

70<br />

or ø7<br />

Drilling plan<br />

4-pole<br />

172<br />

51<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

Front-panel cutout<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Connection allowance<br />

25<br />

Mounting plate<br />

Stud can be rotated 90°<br />

M6 tap or ø7<br />

Breaker<br />

Groove for reducing<br />

heat by overcurrent<br />

10 5<br />

5<br />

10<br />

6-ø48<br />

24 24<br />

4-M6 tap or ø7<br />

13<br />

243<br />

295<br />

12.5<br />

243<br />

243<br />

10<br />

113 110<br />

45<br />

8 32 15<br />

ø13<br />

M12 bolt<br />

8<br />

140<br />

M6 screw for<br />

mounting breaker<br />

70<br />

140<br />

3-pole<br />

ø48<br />

Drilling plan<br />

70<br />

70<br />

210<br />

4-pole<br />

11 11<br />

70<br />

140<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

6<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal block<br />

Stud can be rotated 90°<br />

Breaker<br />

23<br />

126<br />

20<br />

10<br />

243<br />

301<br />

Connection allowance<br />

25<br />

M8 terminal block mounting screw<br />

40<br />

140<br />

13<br />

8<br />

32<br />

15<br />

ø13<br />

M12 bolt<br />

112<br />

70<br />

208<br />

ø10<br />

140<br />

278<br />

155<br />

56 187 56<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

94


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF800-SDW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Reted insulation voltage Ui (V)<br />

NF800-SDW<br />

(700), 800<br />

2<br />

690<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

Time constant<br />

not larger than<br />

10ms<br />

DC<br />

250V<br />

40/40<br />

Standard Attached Parts<br />

(4-pole models are provided<br />

with auxiliary handle.)<br />

Front<br />

connection<br />

Rear<br />

connection<br />

Mounting screw: M6×35 (4pcs)<br />

Insulating barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs)<br />

Mounting screw: M6×40 (4pcs)<br />

Type NF800-SDW<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Type<br />

NF800-SDW<br />

700A,800A<br />

DC<br />

Inst. trip adjustment<br />

range (4 steps)<br />

Operating time<br />

2min<br />

1min.<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

Control<br />

setting<br />

Lo<br />

2<br />

3<br />

Hi<br />

Inst trip<br />

current (A)<br />

2600±520<br />

3900±780<br />

5200±1040<br />

6500±1300<br />

2s<br />

1s<br />

Adjustment<br />

range<br />

700A<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Adjustment<br />

range<br />

800A<br />

Max. total<br />

interrupting time<br />

0.02s<br />

Time-delay trip<br />

Inst trip<br />

0.01s<br />

1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL<br />

mounting<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

(*1) (*1)<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

■External Accessories<br />

(An order for<br />

(*1)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side mounting.<br />

Remark: (1) refer to page 45.<br />

Accessories<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Type name<br />

Operating handle<br />

F<br />

S<br />

V<br />

F8SW<br />

S4SW<br />

V8SWF, V8SW<br />

Mechanical interlock (MI) MI-8SW3 (*1)<br />

Auxiliary handle (HT) HT-4SW<br />

Reference<br />

page<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Terminal cover<br />

(*1)<br />

Large<br />

Skeleton<br />

Rear<br />

Handle<br />

lock device<br />

Accessories<br />

Electrical operation<br />

device<br />

Type name<br />

(TC-L) TCL-8SW3 (*1)<br />

(TTC) TTC-8SW3 (*1)<br />

(BTC) BTC-8SW3 (*1)<br />

HL HL-4SW<br />

HL-S HLS-8SW<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

80<br />

Rated ambient 40°C 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

95


Front connection<br />

Breaker<br />

110<br />

Mounting hole<br />

Insulating barrier (removable)<br />

32<br />

Conductor thickness<br />

t=12 max.<br />

87<br />

94.5<br />

46<br />

8<br />

26<br />

4-pole<br />

3-pole<br />

Breaker<br />

275<br />

Auxiliary handle<br />

(removable)<br />

102<br />

15<br />

Terminal dimension for<br />

directly connecting<br />

conductor<br />

ø8.5<br />

70<br />

3-pole<br />

M6 tap or ø7<br />

R6<br />

92<br />

N<br />

8<br />

ø8<br />

12<br />

Trip button<br />

14<br />

32<br />

51<br />

70<br />

40<br />

210<br />

140<br />

210 280<br />

3-pole<br />

4-pole<br />

32<br />

15<br />

87<br />

Neutral pole<br />

ø14<br />

M12 bolt<br />

ø14<br />

5<br />

97<br />

103<br />

107<br />

155<br />

217<br />

22<br />

8<br />

40<br />

46<br />

(Conductor thickness t=10 max.)<br />

Conductor drilling for direct connection<br />

70<br />

4-pole<br />

243<br />

51<br />

172<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

Front-panel cutout<br />

Drilling plan<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Connection allowance<br />

25<br />

Mounting plate<br />

Stud can be rotated 90°<br />

M6 tap or ø7<br />

Breaker<br />

Groove for reducing heat<br />

by overcurrent<br />

6-ø48<br />

13<br />

243<br />

295<br />

12.5<br />

10 5<br />

243<br />

5<br />

10<br />

24 24<br />

4-M6 tap or ø7<br />

243<br />

10<br />

113 110<br />

45<br />

8 32 15<br />

ø13<br />

M12 bolt<br />

8<br />

140<br />

M6 screw for<br />

mounting breaker<br />

70<br />

140<br />

3-pole<br />

ø48<br />

Drilling plan<br />

70<br />

70<br />

210<br />

4-pole<br />

11 11<br />

70<br />

140<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

6<br />

Plug-in<br />

Mounting plate<br />

Stud can be rotated 90°<br />

Plug-in terminal block<br />

Breaker<br />

20<br />

243<br />

301<br />

Connection allowance<br />

25<br />

13<br />

8<br />

32<br />

112<br />

155<br />

56 187 56<br />

23<br />

126<br />

M8 terminal block mounting screw<br />

40<br />

140<br />

15<br />

ø13<br />

M12 bolt<br />

70<br />

208<br />

ø10<br />

140<br />

278<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

Remarks: (1) Standard specification of NF800-SDW is 2-pole model. 3-pole and 4-pole models are available for DC special voltage.<br />

(2) 2-pole models are 3-pole models with the central pole removed.<br />

96


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF800-UEW<br />

Type NF800-UEW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Reted insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

Standard Attached Parts<br />

(4-pole models are provided<br />

with auxiliary handle.)<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

Front<br />

connection<br />

Rear<br />

connection<br />

NF800-UEW<br />

400-800<br />

adjustable<br />

3 4<br />

690<br />

35/35<br />

170/170<br />

200/200<br />

200/200<br />

200/200<br />

Mounting screw: 3P: M6×35, M6×132 (2pcs each)<br />

4P: M6×35 (3pcs), M6×132 (2pcs)<br />

Insulating barrier: (3P: 2pcs, 4P: 3pcs)<br />

Mounting screw: 3P: M6×40, M6×137 (2pcs each)<br />

4P: M6×40 (3pcs), M6×137 (2pcs)<br />

■Operating Characteristics<br />

10h<br />

5h<br />

Type<br />

2h<br />

NF800-UEW<br />

Operating time<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

pickup current Ip<br />

Ir x(0.70-0.75<br />

-0.8-0.85-0.9 ±10%<br />

-0.95-1.0)<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ±20% 2<br />

(at 200%)<br />

LTD operating time<br />

at-125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Current setting<br />

Ir: 400~800A Rated Current<br />

(Adjustable) In: 800A<br />

LTD operating time TL<br />

12-60-100-150s ±20%<br />

(at 200%)<br />

STD pickup current Is<br />

Ir x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x4~x12 ±15%<br />

(Magnification to In)<br />

Max. total<br />

breaking time<br />

0.6 0.7 1 1.25 2 3 4 5 6 7 10 15 20 30 40<br />

Current (×100% of Ir)<br />

Instantaneous tripping current (×100% of In)<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

(*1)<br />

Operating handle<br />

Right-side<br />

Lead wire<br />

AL AX SHT or UVT<br />

mounting<br />

direction<br />

PAL TI<br />

(*1) (*1)<br />

(*1)<br />

■Current reducing curve<br />

Continuous load current (%)<br />

130<br />

120<br />

110<br />

100<br />

Rated ambient<br />

90<br />

80<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separately for left-side mounting.<br />

Remark: (1) refer to page 45.<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Type name<br />

Operating handle<br />

F<br />

S<br />

V<br />

F8UW(*1)<br />

S4SW<br />

—<br />

Mechanical interlock (MI) MI-8SW3 (*1)<br />

Auxiliary handle (HT) HT-4SW<br />

Reference<br />

page<br />

55<br />

57<br />

—<br />

69<br />

70<br />

Terminal cover<br />

Large<br />

Skeleton<br />

Rear<br />

Handle<br />

lock device<br />

Accessories<br />

Electrical operation<br />

device<br />

Type name<br />

(TC-L) TCL-8UW3 (*1)<br />

(TTC) —<br />

(BTC) BTC-8SW3 (*1)<br />

HL HL-4SW<br />

HL-S HLS-8UW<br />

Reference<br />

page<br />

60<br />

—<br />

60<br />

70<br />

61<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

97


Front connection<br />

110<br />

Mounting hole<br />

Insulating barrier (removable)<br />

N<br />

8<br />

87<br />

322<br />

Conductor thickness<br />

t=12 max.<br />

275<br />

Auxiliary handle<br />

(removable)<br />

102<br />

27.5<br />

143<br />

64<br />

8<br />

ø14<br />

15<br />

112<br />

ø7 ø7<br />

ø8.5<br />

44 (ON side)<br />

123.5 (OFF side)<br />

Terminal dimension for<br />

directly connecting<br />

conductor<br />

12<br />

Trip button<br />

14<br />

51<br />

70<br />

40<br />

210<br />

140<br />

210 280<br />

3-pole<br />

4-pole<br />

Breaker<br />

70<br />

32<br />

15<br />

87<br />

Neutral pole<br />

ø14<br />

M12 bolt<br />

ø14<br />

5<br />

Mounting hole<br />

143<br />

194<br />

200<br />

204<br />

252<br />

314<br />

8<br />

Insulating barrier (removable)<br />

48<br />

110<br />

22<br />

40<br />

(Conductor thickness t=10 max.)<br />

Auxiliary handle<br />

(removable)<br />

Conductor drilling for<br />

direct connection<br />

Conductor<br />

thickness<br />

t=8 max.<br />

143<br />

97<br />

6.5<br />

ø14<br />

ø7<br />

R6<br />

4-pole<br />

3-pole<br />

51<br />

172<br />

Breaker<br />

22.5<br />

92<br />

290<br />

322<br />

275<br />

102<br />

27.5<br />

15<br />

112<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

Front-panel cutout<br />

N<br />

16<br />

ø7<br />

70<br />

M6 screw or ø7<br />

3-pole<br />

Drilling plan<br />

70<br />

4-pole<br />

Trip button<br />

51<br />

70<br />

210<br />

280<br />

35<br />

48<br />

ø14<br />

M12 bolt<br />

Neutral pole<br />

ø14<br />

5<br />

6.5<br />

141<br />

194<br />

200<br />

204<br />

NF400-UEW 4-pole<br />

314<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

6<br />

Standard direction of stud is horizontal<br />

Connection on power side, and vertical on load side.<br />

Mounting plate allowance Otherwise, specify the direction.<br />

25<br />

M6 tap or ø7<br />

Breaker<br />

Groove for reducing<br />

heat by overcurrent<br />

13<br />

10 5<br />

45<br />

12.5<br />

290<br />

342<br />

290<br />

6-ø48<br />

24 24<br />

24 24<br />

290<br />

252<br />

Mounting plate<br />

Connection<br />

allowance Stud can be<br />

25 rotated 90˚<br />

8<br />

5<br />

10<br />

4-M6 tap or ø7<br />

26<br />

290<br />

342<br />

8 32 15<br />

10<br />

10<br />

210 110<br />

ø13<br />

140<br />

M12 bolt<br />

M6 screw for<br />

mounting<br />

breaker<br />

70<br />

140<br />

3-pole<br />

ø48<br />

70<br />

70<br />

210<br />

4-pole<br />

10<br />

210 83<br />

20<br />

NF400-UEW 4-pole<br />

ø13<br />

M12 bolt<br />

11 11<br />

70<br />

140<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

Drilling plan<br />

98


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF1000-SEW<br />

NF1250-SEW<br />

Type name<br />

Rated current In (Amp.)<br />

NF1000-SEW<br />

500–1000<br />

Adjustable<br />

NF1250-SEW<br />

600–1250<br />

Adjustable<br />

Number of poles<br />

Reted insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

AC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

3 4<br />

690<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

125/63<br />

3 4<br />

690<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

125/63<br />

Type NF1250-SEW<br />

Standard Attached Parts<br />

Front<br />

connection<br />

Rear<br />

connection<br />

Mounting screw: M8×40 (4pcs)<br />

Insulating barrier: (3P: 2pcs, 4P: 3pcs)<br />

Auxiliary handle: (1pc)<br />

Mounting screw: M8×40 (4pcs)<br />

Insulating barrier: (3P: 2pcs, 4P: 4pcs)<br />

Auxiliary handle: (1pc)<br />

■Operating Characteristics<br />

10h<br />

10h<br />

5h<br />

2h<br />

Type<br />

NF1000-SEW<br />

5h<br />

2h<br />

Type<br />

NF1250-SEW<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

LTD operating time at-125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Current setting<br />

Ir:500-1000A<br />

(Adjustable)<br />

Rated Current<br />

In:1000A<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

LTD operating time<br />

at-125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Current setting<br />

Ir:600-1250A<br />

(Adjustable)<br />

Rated Current<br />

In:1250A<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Pre-alarm<br />

pickup current Ip<br />

In x(0.7-0.75-0.8-0.85<br />

-0.9-0.95-1.0) ± 10%<br />

LTD operating time TL<br />

12-60-100-150s ± 20%<br />

(at 200%)<br />

STD pickup current Is<br />

In x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ± 15%<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Pre-alarm<br />

pickup current Ip<br />

In x(0.7-0.75-0.8-0.85<br />

-0.9-0.95-1.0) ± 10%<br />

LTD operating time TL<br />

12-60-100-150s ± 20%<br />

(at 200%)<br />

STD pickup current Is<br />

In x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ± 15%<br />

1s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ± 20% 2<br />

(at 200%)<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ± 20% 2<br />

(at 200%)<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x (4~x12) ± 15%<br />

(Magnification to In)<br />

Max. total<br />

breaking time<br />

60 70 100 125 200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x (4~x12) ± 15%<br />

(Magnification to In)<br />

Max. total<br />

breaking time<br />

60 70 100 125 200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

Current (of Ir)<br />

Instantaneous tripping current (of In)<br />

Current (of Ir)<br />

Instantaneous tripping current (of In)<br />

■Internal Accessories<br />

■Current reduction curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL<br />

mounting<br />

Remark: (*1) refer to page 45.<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

PAL<br />

Continuous load current (%)<br />

130<br />

120<br />

110<br />

100<br />

Rated ambient<br />

90<br />

80<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

■External Accessories<br />

(An order for should be placed at the same time as an order of circuit breaker main body.)<br />

Accessories Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

Operating handle<br />

F F10SW (*1) 55 Auxiliary handle HT-10SW<br />

S S10SW<br />

57 Handle lock (HL)<br />

Mechanical interlock (MI) MI-10SW3 (*1) 69 Large terminal cover (TC-L) TCL-10SW3 (*1)<br />

Electrical operation device<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

Reference<br />

page<br />

70<br />

60<br />

61<br />

99


Front connection<br />

110<br />

Insulating barrier (removable)<br />

Mounting<br />

hole<br />

Conductor thickness<br />

t=8 × 2pcs max.<br />

Bolt M12 × 50<br />

15 40<br />

Breaker<br />

Auxiliary handle<br />

(removable)<br />

8<br />

406<br />

346<br />

375<br />

13<br />

ø9.5<br />

15 32<br />

ø13 M12 bolt<br />

43<br />

140<br />

210<br />

3-pole<br />

80<br />

70<br />

210<br />

280<br />

4-pole<br />

Neutral pole<br />

ø17.5<br />

15 44<br />

133.5<br />

17 140<br />

190<br />

280<br />

18.5<br />

70 M8 tap or ø10 70<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

Rear connection<br />

Mounting plate<br />

M8 screw for mounting breaker<br />

Stud can be rotated 90°<br />

Breaker<br />

35.5<br />

4-pole<br />

3-pole<br />

Breaker<br />

13<br />

140<br />

8 32 15<br />

97<br />

109<br />

18 Connection<br />

allowance<br />

ø13<br />

22<br />

45<br />

273<br />

12<br />

140<br />

Conductor thickness<br />

t=6 × 2pcs max.<br />

Bolt M12 × 45<br />

Insulation cover<br />

(removable)<br />

86 39.5 86<br />

81.5<br />

269<br />

70 70 80<br />

230<br />

300<br />

1.0mm clearance on each<br />

M8 tap or ø10<br />

side of the handle frame.<br />

3-pole<br />

4-pole<br />

Front-panel cutout<br />

Drilling plan<br />

R11.5<br />

97<br />

Plug-in<br />

Plug-in terminal block<br />

Mounting plate<br />

M10 terminal block mounting screw<br />

Breaker<br />

225<br />

25.5<br />

68<br />

208 134<br />

12 105<br />

269<br />

Stud can be rotated 90°<br />

Conductor thickness<br />

t=6 × 2pcs max.<br />

Bolt M12 × 45<br />

30<br />

Connection<br />

allowance<br />

ø13<br />

Insulating<br />

barrier<br />

140<br />

43<br />

13<br />

15 32 8<br />

104<br />

ø12<br />

70<br />

204<br />

3-pole<br />

Drilling plan<br />

140<br />

274<br />

4-pole<br />

136 100.5 136 28.5<br />

28.5 269<br />

6<br />

100


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF1250-SDW<br />

Type NF1250-SDW<br />

Type name<br />

Rated current In (Amp.)<br />

Number of poles<br />

Rated insulation voltage Ui (V)<br />

Rated shortcircuit<br />

breaking<br />

capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

Time constant<br />

not larger than<br />

10ms<br />

DC 250V<br />

Standard Attached<br />

Parts<br />

Front<br />

connection<br />

Rear<br />

connection<br />

NF1250-SDW<br />

1000, 1250<br />

2<br />

690<br />

40/20<br />

Mounting screw: M8 × 40 (4pcs)<br />

Insulating barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs)<br />

Auxiliary handle: (1pc)<br />

Mounting screw: M8 × 40 (4pcs)<br />

Insulating cover: (3P: 2pcs, 4P: 4pcs)<br />

Auxiliary handle: (1pc)<br />

■Operating Characteristics<br />

3h<br />

2h<br />

3h<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

Maximum<br />

Type<br />

NF1250-SDW<br />

1000A<br />

DC<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

Maximum<br />

Type<br />

NF1250-SDW<br />

1250A<br />

DC<br />

2min<br />

2min<br />

Operating time<br />

1min<br />

40s<br />

30s<br />

20s<br />

10s<br />

6s<br />

4s<br />

2s<br />

1s<br />

0.6s<br />

0.4s<br />

Minimum<br />

Inst. trip adjustment range<br />

(4 steps)<br />

Control<br />

Inst. trip<br />

setting<br />

current(A)<br />

L0<br />

2800 ± 700<br />

2<br />

4200 ± 700<br />

3<br />

5600 ± 700<br />

Hi<br />

7000 ± 700<br />

Operating time<br />

1min<br />

40s<br />

30s<br />

20s<br />

10s<br />

6s<br />

4s<br />

2s<br />

1s<br />

0.6s<br />

0.4s<br />

Minimum<br />

Inst. trip adjustment range<br />

(4 steps)<br />

Control<br />

Inst. trip<br />

setting<br />

current(A)<br />

L0<br />

2800 ± 700<br />

2<br />

4200 ± 700<br />

3<br />

5600 ± 700<br />

Hi<br />

7000 ± 700<br />

0.2s<br />

0.2s<br />

0.1s<br />

0.06s<br />

Max. total<br />

interrupting time<br />

0.0.4s<br />

Time<br />

0.02s<br />

delay trip<br />

Inst. trip<br />

0.01s<br />

1 1.25 2 3 4 5 7 10 20 30 40 50 70<br />

0.1s<br />

0.06s<br />

Max. total<br />

interrupting time<br />

0.0.4s<br />

0.02s Time<br />

delay trip<br />

Inst. trip<br />

0.01s<br />

1 1.25 2 3 4 5 7 10 20 30 40 50 70<br />

Current (×100% of rated current)<br />

Current (×100% of rated current)<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL<br />

mounting<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

1000A<br />

120<br />

110<br />

1250A<br />

100<br />

Rated ambient<br />

90<br />

Remark: (1) refer to page 45.<br />

80<br />

5<br />

10<br />

20 30 40 50 60<br />

Ambient temperature (°C)<br />

■External Accessories<br />

(An order for should be placed at the same time as an order of circuit breaker main body.)<br />

Accessories<br />

Type name<br />

Operating handle<br />

F F10SW (*1)<br />

S S10SW<br />

Mechanical interlock (MI) MI-10SW3 (*1)<br />

Reference<br />

page<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

55<br />

57<br />

69<br />

Accessories<br />

Type name<br />

Auxiliary handle HT-10SW<br />

Handle lock (HL)<br />

Large terminal cover (TC-L) TCL-10SW3 (*1)<br />

Electrical operation device<br />

Reference<br />

page<br />

70<br />

60<br />

61<br />

101


Front connection<br />

Outside dimensions are same as those of NF1000-SEW and NF1250-SEW.<br />

110<br />

Insulating barrier<br />

(removable)<br />

Mounting hole<br />

Conductor thickness<br />

t=8 × 2pcs max.<br />

Bolt M12 × 50<br />

Auxiliary handle<br />

(removable)<br />

15 40<br />

Breaker<br />

13<br />

8<br />

406<br />

ø9.5<br />

15 32<br />

346<br />

375<br />

ø13 M12 bolt<br />

43<br />

140<br />

210<br />

3-pole<br />

80<br />

70<br />

210<br />

280<br />

4-pole<br />

ø17.5<br />

15 44<br />

133.5<br />

17 140<br />

190<br />

280<br />

18.5<br />

70 70<br />

M8 screw or ø10<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

Rear connection<br />

Outside dimensions are different from those of NF1000-SEW and NF1250-SEW.<br />

18<br />

Mounting plate<br />

M8 screw for mounting breaker<br />

Stud can be rotated 90˚<br />

Breaker<br />

35.5<br />

4-pole<br />

3-pole<br />

Breaker<br />

109<br />

86<br />

187.5<br />

R11.5<br />

13<br />

Connection allowance<br />

22 ø13<br />

45<br />

233<br />

Conductor thickness<br />

t=6 × 2pcs max.<br />

86<br />

375<br />

97<br />

140<br />

18<br />

8 32 15<br />

97<br />

12<br />

Bolt M12 × 45<br />

70 70<br />

140 230<br />

300<br />

Insulation cover<br />

(removable)<br />

M8 screw or ø10<br />

3-pole<br />

4-pole<br />

20.5<br />

80<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

Drilling plan<br />

Front-panel cutout<br />

6<br />

Plug-in<br />

Outside dimensions are different from those of NF1000-SEW and NF1250-SEW.<br />

Plug-in terminal block<br />

Mounting plate<br />

M10 terminal block mounting screw<br />

Stud can be rotated 90˚<br />

Breaker<br />

248<br />

48<br />

318<br />

375<br />

208<br />

68 25.5<br />

134<br />

12<br />

30<br />

Connection allowance<br />

Conductor thickness<br />

t=6 × 2pcs max. ø13<br />

43<br />

140<br />

Bolt M12 × 45 Insulating barrier<br />

13<br />

15 8<br />

32<br />

104<br />

70<br />

204<br />

3-pole<br />

ø12<br />

140<br />

274<br />

4-pole<br />

Drilling plan<br />

Remarks: (1) Standard specifications of NF1250-SDW is 2-pole models. 3-pole and 4-pole models are for DC special voltage.<br />

(2) 2-pole models are 3-pole models with the central pole removed.<br />

102


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF1600-SEW<br />

Type name<br />

Rated current In (Amp.)<br />

NF1600-SEW<br />

Adjustable<br />

800–1600<br />

Type NF1600-SEW<br />

Number of poles<br />

Reted insulation voltage Ui (V)<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

(Icu/Ics)<br />

Standard Attached<br />

Parts<br />

AC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

Front<br />

connection<br />

Rear<br />

connection<br />

3 4<br />

690<br />

25/13<br />

65/33<br />

85/43<br />

85/43<br />

125/63<br />

Mounting screw: M8 × 40 (4pcs)<br />

Insulating barrier: (3P: 2pcs, 4P: 3pcs)<br />

Auxiliary handle: (1pc)<br />

Mounting screw: M8 × 40 (4pcs)<br />

Auxiliary handle: (1pc)<br />

■Operating Characteristics<br />

10h<br />

5h<br />

2h<br />

Type<br />

NF1600-SEW<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

LTD operating time at-125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Current setting<br />

Ir:800-1600A<br />

(Adjustable)<br />

Rated Current<br />

In:1600A<br />

6min<br />

4min<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

pickup current Ip<br />

In x(0.7-0.75-0.8-0.85<br />

-0.9-0.95-1.0) ± 10%<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ± 20% 2<br />

(at 200%)<br />

LTD operating time TL<br />

12-60-100-150s ± 20%<br />

(at 200%)<br />

STD pickup current Is<br />

In x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ± 15%<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x (4~12) ± 15%<br />

(Magnification to In)<br />

Current (of Ir)<br />

Instantaneous tripping current (of In)<br />

Max. total<br />

breaking time<br />

60 70 100 125 200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

■Internal Accessories<br />

■Current reducing curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL<br />

mounting<br />

Remark: (1) refer to page 45.<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

PAL<br />

Continuous load current (%)<br />

130<br />

120<br />

110<br />

100<br />

Rated ambient<br />

90<br />

80<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

■External Accessories<br />

(An order for should be placed at the same time as an order of circuit breaker main body.)<br />

Accessories<br />

Type name<br />

Operating handle<br />

F F10SW (*1)<br />

S S10SW<br />

Mechanical interlock (MI) MI-16SW3 (*1)<br />

Reference<br />

page<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

55<br />

57<br />

69<br />

Accessories<br />

Type name<br />

Auxiliary handle HT-10SW<br />

Handle lock (HL)<br />

Electrical operation device<br />

Reference<br />

page<br />

70<br />

61<br />

103


Front connection<br />

Insulating barrier 60<br />

(removable)<br />

38<br />

(185.5)<br />

15<br />

38<br />

ø11<br />

(185.5)<br />

Conductor thickness t=6 × W75 max.<br />

Bolt M10 × 65<br />

Auxiliary handle<br />

(removable)<br />

20 35<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Mounting hole<br />

210 280<br />

18.5<br />

R11.5<br />

406<br />

346<br />

375<br />

97<br />

N<br />

ø17.5<br />

ø9.5<br />

203<br />

263<br />

3-pole<br />

115<br />

101.5<br />

304.5<br />

364.5<br />

4-pole<br />

130<br />

Neutral pole<br />

17<br />

20<br />

133.5<br />

140<br />

190<br />

280<br />

49.5<br />

70 70<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

M8 tap or ø10<br />

80<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

Front-panel cutout<br />

Rear connection<br />

Connection<br />

allowance<br />

15 38 15<br />

38<br />

38<br />

212<br />

60<br />

18<br />

106 106<br />

318<br />

Stud can be rotated 90˚<br />

Mounting angle<br />

Conductor thickness<br />

t=6 × W75 max.<br />

Stud can be rotated 90˚<br />

Mounting angle<br />

Conductor thickness<br />

t=6 × W75 max.<br />

273<br />

Breaker<br />

Mounting angle<br />

18 20<br />

109<br />

273<br />

160 min.<br />

100 max.<br />

81.5<br />

269<br />

15<br />

20<br />

109<br />

Connection<br />

allowance<br />

140<br />

3-pole<br />

140<br />

38 38<br />

125 15<br />

200<br />

15<br />

60<br />

36<br />

ø11<br />

BM10 × 50 bolt<br />

70<br />

210<br />

4-pole<br />

140 125<br />

54<br />

ø11<br />

M10 × 50 bolt<br />

70 M8 tap or ø10 70<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

6<br />

104


6. Characteristics and Dimensions<br />

Molded-Case Circuit Breakers<br />

NF1600-SDW<br />

Type name<br />

NF1600-SDW<br />

Rated current In (Amp.)<br />

1600<br />

Number of poles<br />

2<br />

Reted insulation voltage Ui (V)<br />

Rated shortcircuit<br />

breaking<br />

capacity (kA)<br />

690<br />

IEC 60947-2<br />

(Icu/Ics)<br />

Time constant<br />

not larger than<br />

10msec<br />

DC<br />

250V<br />

40/20<br />

Type NF1600-SDW<br />

Standard Attached<br />

Parts<br />

Front<br />

connection<br />

Rear<br />

connection<br />

Mounting screw: M8 × 40 (4pcs)<br />

Insulating barrier: (2P: 1pc, 3P: 2pcs, 4P: 3pcs)<br />

Auxiliary handle: (1pc)<br />

Mounting screw: M8 × 40 (4pcs)<br />

Auxiliary handle: (1pc)<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Max. allowable time of Overcurrent<br />

Type<br />

NF1600-SDW<br />

for MAG-ONLY<br />

1600A<br />

DC<br />

2min<br />

1min<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

Inst. trip adjustment<br />

range (4 steps)<br />

Contro Inst. trip<br />

settingl current(A)<br />

2s<br />

1s<br />

0.5s<br />

Lo<br />

2<br />

3<br />

Hi<br />

3200±800<br />

4800±800<br />

6400±800<br />

8000±800<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

interrupting time<br />

0.02s<br />

Inst.trip<br />

0.01s<br />

100 125 200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

×100% of rated current<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL<br />

mounting<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Remark: (1) refer to page 45.<br />

■External Accessories<br />

(An order for should be placed at the same time as an order of circuit breaker main body.)<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Operating handle<br />

Mechanical interlock<br />

F F10SW (*1)<br />

S S10SW<br />

(MI) MI-16SW3 (*1)<br />

55 Auxiliary handle HT-10SW<br />

57 Handle lock (HL)<br />

69 Electrical operation device<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

70<br />

61<br />

105


Front connection<br />

Outside dimensions are same as those of NF1600-SEW.<br />

Insulating barrier<br />

(removable)<br />

(185.5)<br />

60 ø11<br />

38<br />

15<br />

38<br />

Conductor thickness t=6 × W75 max.<br />

20 35<br />

210 Mounting hole<br />

280<br />

18.5<br />

R11.5<br />

ø17.5<br />

ø9.5<br />

97<br />

(185.5)<br />

Bolt M10 × 65<br />

Auxiliary handle<br />

(removable)<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

406<br />

346<br />

375<br />

203<br />

263<br />

3-pole<br />

115<br />

101.5<br />

304.5<br />

364.5<br />

4-pole<br />

130<br />

17<br />

M8 tap or ø10<br />

20 49.5<br />

70 70 80<br />

133.5<br />

140<br />

190<br />

280<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

Front-panel cutout<br />

Rear connection<br />

Outside dimensions are different from those of NF1600-SEW.<br />

Connection allowance<br />

15 38 15<br />

212<br />

106<br />

318<br />

18 38<br />

60<br />

106<br />

Mounting angle<br />

36<br />

ø11<br />

Conductor thickness<br />

Mounting angle M10 × 50 bolt<br />

t=6 × W75 max. Conductor thickness<br />

t=6 × W75 max.<br />

20<br />

Connection allowance<br />

15<br />

38<br />

60<br />

109<br />

233<br />

20<br />

109<br />

233<br />

Breaker<br />

Mounting angle<br />

175 min. 160 min.<br />

375<br />

140<br />

Stud can be rotated 90˚<br />

3-pole<br />

38<br />

125<br />

140 200<br />

ø11<br />

38 15 M10 × 50 bolt<br />

15<br />

Stud is in horizontal direction.<br />

Stud can not be rotated 90˚<br />

4-pole<br />

140<br />

125<br />

70 70<br />

M8 tap or ø10<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

6<br />

Remarks: (1) Standard specification of NF1600-SDW is 2-pole model. 3-pole and 4-pole models are for DC special voltage.<br />

(2) 2-pole models are 3-pole models with the central pole removed.<br />

106


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV30-CS<br />

Type NV30-CS<br />

Type name<br />

Number of poles<br />

Rated operational voltage Ue (V AC)<br />

Rated current In (A)<br />

High-speed<br />

type<br />

Rated current sensitivity I∆n (mA)<br />

Max.operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max.operating time at 2I∆n (s)<br />

Time-delay<br />

type<br />

Inertial non-operating time at 2I∆n (s)<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

440V<br />

breaking capacity (kA)<br />

IEC 60947-2<br />

AC 400V<br />

Icu/Ics<br />

230V<br />

Standard Attached Parts (Front connection)<br />

NV30-CS<br />

3<br />

100–230 Multi-voltage type<br />

5 10 15 20 30<br />

30<br />

0.04<br />

—<br />

—<br />

—<br />

Button<br />

—<br />

—<br />

2.5/2<br />

Mounting screw: M4 × 0.7 × 20 (2pcs.)<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

3h<br />

Operating time<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

40s<br />

30s<br />

20s<br />

10s<br />

6s<br />

4s<br />

Max.<br />

Type NV30-CS<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

2s<br />

0.01s<br />

1s<br />

0.6s<br />

0.4s<br />

Min.<br />

25 50 100 500 1000<br />

Ground-fault current<br />

(×100% of rated current sensitivity)<br />

0.2s<br />

0.1s<br />

0.06s<br />

0.04s<br />

0.02s<br />

0.01s<br />

1<br />

1.25 2 3 4 5 7 10 20 30 40 50 70 100<br />

×100% of rated current<br />

■Internal Accessories<br />

■Temperature Characteristics<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

MG<br />

Remark: (1) Standard lead wire is drawn from side. However, lead wire drawn by load can be produced<br />

upon request.<br />

(2) refer to page 44.<br />

AX<br />

Lead wire<br />

direction<br />

Operating time change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10<br />

0<br />

10<br />

Rated ambient<br />

20<br />

30<br />

40<br />

Ambient temperature (°C)<br />

50<br />

60<br />

■External Accessories<br />

■Internal Wiring Diagram<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

Test button<br />

Lock cover (LC)<br />

Rail mounting adapter<br />

Handle lock device<br />

LC03CS<br />

DIN-03CS<br />

HL-05FH<br />

70<br />

70<br />

70<br />

Terminal cover<br />

Small<br />

Large<br />

Rear<br />

Skeleton<br />

(TC-S)<br />

(TC-L)<br />

(BTC)<br />

(TTC)<br />

TCS-03CS3W<br />

TCL-03CS3W<br />

BTC-03CS<br />

TTC-03CS<br />

60<br />

Line side<br />

ZCT<br />

Load side<br />

Magnetic<br />

device<br />

Senstivity<br />

selector<br />

Leakage<br />

indication button<br />

107


Front connection<br />

Mtg. hole<br />

67.5<br />

Test button<br />

M5 screw<br />

14.5<br />

Applicable<br />

wire size:1.6mm-dia.to 22mm 2<br />

Breaker<br />

76.5<br />

96<br />

64<br />

54<br />

50<br />

ø8.5<br />

10<br />

ø5.5<br />

ø5<br />

6<br />

84<br />

23.5<br />

Leakage<br />

indicator button<br />

4<br />

28<br />

49<br />

52<br />

55<br />

12.5 (max)<br />

Bus t max. =3<br />

Bus drilling for<br />

direct connection<br />

23.5<br />

Drilling plan<br />

M4 ✕ 0.7<br />

taps or ø5<br />

67<br />

Rear connection<br />

Mtg plate t max =3.2<br />

M4 ✕ 0.7 taps<br />

or ø5<br />

Breaker<br />

Breaker<br />

R1<br />

76.5<br />

45 (min)<br />

25 (min)<br />

5<br />

76.5<br />

84<br />

52<br />

38.5<br />

58.5<br />

23.5<br />

ø14<br />

65<br />

55<br />

Insulating tube<br />

8<br />

M6 screw<br />

Breaker mtg<br />

M4 ✕ 0.7 screw<br />

47<br />

Drilling plan<br />

Front-plate cutout<br />

6<br />

108


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV32-SW<br />

NV63-SW<br />

NV63-CW<br />

NV63-HW<br />

Type name NV32-SW NV63-CW NV63-SW NV63-HW<br />

Rated current In (Amp.)<br />

Number of poles 3 3 3 3<br />

Rated operational voltage Ue (V AC)<br />

Rated current sensitivity I∆n (mA)<br />

High-speed type<br />

Max. operating time at 5I∆n (s)<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2 (Icu/Ics)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

(5) 6 10<br />

(15) 16 20<br />

25 (30) 32<br />

100–440<br />

Multi-voltage type<br />

30,100 • 200 • 500<br />

Selectable<br />

(5) (10) (15) 16<br />

20 25 (30) 32<br />

40 50 (60) 63<br />

100–440<br />

Multi-voltage type<br />

30,100 • 200 • 500<br />

Selectable<br />

(5) (10) (15) 16<br />

20 25 (30) 32<br />

40 50 (60) 63<br />

100–440<br />

Multi-voltage type<br />

30,100 • 200 • 500<br />

Selectable<br />

(15) 16 20 25<br />

(30) 32 40 50<br />

(60) 63<br />

100–440<br />

Multi-voltage type<br />

30,100 • 200 • 500<br />

Selectable<br />

0.04 0.04 0.04 0.04<br />

Button<br />

Button<br />

Button<br />

Button<br />

5/2<br />

2.5/1<br />

7.5/4<br />

10/5<br />

5/2<br />

5/2<br />

7.5/4<br />

10/5<br />

10/5<br />

7.5/4<br />

15/8<br />

25/13<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (3P: 2pcs) excluding models of NV63-CW<br />

Type NV63-SW<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

4h<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

Types<br />

NV32-SW<br />

NV63-CW NV63-SW NV63-HW<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

2s<br />

1s<br />

Min.<br />

0.2s<br />

0.1s<br />

0.5s<br />

0.04s<br />

0.02s<br />

0.2s<br />

0.01s<br />

0.1s<br />

0.05s<br />

0.02s<br />

25 50 100 500 1000<br />

Ground-fault current<br />

(×100% of rated current sensitivity)<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of Rated current<br />

■Internal Accessories<br />

■Temperature Characteristics<br />

Remark: (1) refer to page 44.<br />

Left-side<br />

mounting<br />

AL<br />

MG<br />

TBM<br />

Operating handle<br />

Right-side<br />

mounting<br />

AX UVT<br />

EAL<br />

Lead wire<br />

direction<br />

Operating time change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

Rated ambient<br />

40<br />

Ambient temperature (°C)<br />

50<br />

60<br />

■External Accessories<br />

■Internal Wiring Diagram<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

F<br />

S<br />

V<br />

Type name<br />

F05SW<br />

S05SW<br />

V05SWF<br />

Reference<br />

page<br />

55<br />

57<br />

54<br />

R —<br />

LC<br />

(*1)<br />

HL<br />

HL-S<br />

LC-05SW<br />

HLF-05SW<br />

HLN-05SW<br />

HLS-05SW<br />

—<br />

70<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

Ml Ml-05SW3 (*1) 69<br />

Small TC-S TCS-05SW3W<br />

Large TC-L TCL-05SW3W<br />

Skeleton TTC TTC-05SW3<br />

Rear BTC BTC-05SW3W<br />

Plug-in PTC PTC-05SW3W<br />

Reference<br />

page<br />

60<br />

Line side<br />

Magnetic<br />

device<br />

Test button<br />

Senstivity<br />

selector<br />

ZCT<br />

Load side<br />

IEC 35mm rail<br />

mounting adapters<br />

DIN-05SW 70<br />

Note: (*1) HLF and HLS types are used for OFF-lock, and HLN types for ON-lock.<br />

Leakage<br />

indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.<br />

109


Front connection<br />

Insulation barrier<br />

(removable)<br />

M5×0.8 screw<br />

(M6 for 63A)<br />

Applicable<br />

wire size:1.6mm-dia.to 22mm 2<br />

Mounting hole<br />

Sensitivity current<br />

selector<br />

24<br />

Breaker<br />

φ5.5<br />

(6.5mm-diameter for 63A)<br />

φ8.5<br />

φ4.5<br />

6<br />

111<br />

130<br />

84<br />

50<br />

111<br />

Trip button<br />

22<br />

50<br />

75<br />

Test button<br />

Leakage<br />

indicaton button<br />

45<br />

61<br />

68<br />

12.5 max.<br />

(Conductor thickness<br />

t=5 max.)<br />

25<br />

M4×0.7 taps<br />

or 5mm dia.hole<br />

4<br />

72<br />

Conductor drilling<br />

for direct connection<br />

Drilling plan<br />

90<br />

Rear connection<br />

Mounting panel<br />

t=3.2max<br />

Insulation tube<br />

Breaker<br />

Breaker<br />

8<br />

111<br />

R1<br />

52<br />

8<br />

111<br />

27 min.<br />

M6 screw<br />

50<br />

M4×0.7 screw<br />

for mounting breaker<br />

25<br />

50<br />

φ14<br />

M4×0.7 taps<br />

or 5mm-dia.hole<br />

70<br />

1.0mm clearance on each side of<br />

the handle frame.<br />

68<br />

72<br />

42<br />

Drilling plan<br />

Front-panel cutout<br />

6<br />

Plug-in<br />

M5×0.8<br />

terminal block mounting screw<br />

80<br />

Plug-in terminal block<br />

Mounting panel<br />

3<br />

50<br />

Breaker (plug-in terminal block)<br />

15.5<br />

5.5<br />

11<br />

83.5<br />

85<br />

180<br />

111<br />

16.5 max.<br />

Center line of<br />

breaker body<br />

7<br />

54<br />

54 80 54<br />

10<br />

21<br />

89<br />

30<br />

M6 screw<br />

φ6.5<br />

25<br />

82<br />

6mm-dia.hole or<br />

M5×0.8 taps<br />

Details of terminal<br />

Conductor drilling cutout<br />

for direct connection<br />

Cutout and drilling plan<br />

Remark: In case of the CE marking, outside sizes differ.<br />

110


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV125-CW<br />

NV125-HW<br />

Type NV125-SW<br />

NV125-SW<br />

Type name NV125-CW NV125-SW NV125-HW<br />

(15) 16 20 (30) (15) 16 20 (30)<br />

63 (75) 80<br />

Rated current In (Amp.)<br />

32 40 50 (60) 63 32 40 50 (60)<br />

100 125<br />

(75) 80 100 (125) *1 63 (75) 80 100<br />

Number of poles 3 3 4<br />

3<br />

4<br />

Rated operational voltage Ue (V AC) (2)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

100–440<br />

Multi-voltage type<br />

30,100 • 200 • 500<br />

Selectable<br />

100–440 200–440 100–440 200–440<br />

Multi-voltage type Multi-voltage type Multi-voltage type Multi-voltage type<br />

30,100 • 200 • 500<br />

Selectable<br />

*1: 3P only<br />

Notes: (1) The time-delayed types will be produced when they have the current specifications of 20A or more.<br />

(2) Rated operational voltage of time-delay type is for 200-440V.<br />

30,100 • 200 • 500<br />

Selectable<br />

0.04 0.04 0.04<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

10/5<br />

10/5<br />

30/15<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

Mounting screw: M4×0.7×55 (3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (3P: 2pcs, 4P: 3pcs)<br />

excluding models of NV125-CW<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

50/25<br />

50/25<br />

100/50<br />

■Operating Characteristics<br />

4h<br />

4h<br />

4h<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-CW 63A~100A<br />

NV125-SW 40A~100A<br />

NV125-HW 40A~100A<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-SW 16A~20A<br />

NV125-HW 16A~20A<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-CW 125A<br />

NV125-SW 125A<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NV125-SW 32A<br />

NV125-HW 32A<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max. (60A~100A)<br />

Max. (40A~50A)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

1s<br />

1s<br />

1s<br />

1s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking<br />

time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

Operating time<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

×100% of Rated current<br />

■Earth-Leakage Tripping<br />

Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

0.02s<br />

0.01s<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Time-delay trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

×100% of Rated current<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

AL AX UVT<br />

MG EAL TBM<br />

Instantaneous trip<br />

6070<br />

Operating handle<br />

Right-side<br />

mounting<br />

Remark: (1) refer to page 44.<br />

Lead wire<br />

direction<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

×100% of Rated current<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

×100% of Rated current<br />

■Temperature Characteristics<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Rated ambient<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Instantaneous trip<br />

25<br />

50 100 500 1000<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

Ground-fault current (% of rated current sensitivity)<br />

■External Accessories<br />

Accessories<br />

Operating<br />

handle<br />

Handle lock<br />

device<br />

F<br />

S<br />

V<br />

R<br />

F1SW<br />

S1SW<br />

V1SW (*1)<br />

R1SW<br />

55<br />

57<br />

54<br />

58<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

Type name<br />

LC-1SW<br />

HLF-1SW<br />

HLN-1SW<br />

HLS-1SW<br />

Reference<br />

page<br />

70<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Ml Ml-05SW3 (*4) 69<br />

Small TC-S TCS-1SW3W (*4)<br />

Large TC-L TCL-1SW3W (*4)<br />

Skeleton TTC TTC-1SW3(*4)<br />

Rear BTC BTC-1SW3W (*4)<br />

Plug-in PTC PTC-1SW3W (*4)<br />

IEC 35mm rail<br />

mounting adapters<br />

Type name<br />

Reference<br />

page<br />

60<br />

DIN-1SW (*4) 70<br />

■Internal Wiring Diagram<br />

Line side<br />

Magnetic<br />

device<br />

Test button<br />

Senstivity<br />

selector<br />

ZCT<br />

Load side<br />

111<br />

Electrical<br />

operation device<br />

Notes: (*1) Attach the letter "F" to the end of designation for a fixed type.<br />

(*2) HLF and HLS types are used for OFF-lock, and HLN types for ON-lock.<br />

(*3) Specify the working voltage.<br />

(*4) The designation depends on the number of poles. Refer to the reference page.<br />

MDS-NV1SWE (*3)<br />

61<br />

Leakage<br />

indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.


Front connection<br />

Mounting hole<br />

50<br />

CL<br />

Sensitivity current<br />

selector<br />

CL<br />

Insulation barrier<br />

(removable)<br />

Sensitivity current<br />

selector<br />

M8 screw<br />

24<br />

Solderless terminal<br />

for wire size<br />

14~2/0AWG CU/AL<br />

CL<br />

Breaker<br />

CL<br />

130<br />

112<br />

CL<br />

Operating time<br />

selector<br />

(time-delay type)<br />

Leakage<br />

indication button<br />

Operating time<br />

selector<br />

(time-delay type)<br />

Leakage<br />

indication button<br />

84<br />

50<br />

Wire connection<br />

CL<br />

110-111<br />

(*1)<br />

Test button<br />

Test button<br />

Trip<br />

button<br />

22<br />

Trip<br />

button<br />

30<br />

Neutral pole<br />

45<br />

ø8.5<br />

30<br />

30<br />

60<br />

90<br />

61<br />

68<br />

8<br />

M4×0.7 taps<br />

or 5mm-dia. hole<br />

90<br />

120<br />

4 72<br />

19 max.<br />

3-pole<br />

4-pole<br />

3-pole<br />

4-pole<br />

90<br />

(Conductor thickness<br />

Drilling plan<br />

t=5 max.)<br />

Conductor drilling<br />

for direct connection<br />

Rear connection<br />

Mounting plate<br />

t=3.2 max.<br />

52<br />

102<br />

Mounting base<br />

Stud rotatable<br />

by 90°<br />

4-pole<br />

3-pole<br />

LC<br />

Breaker<br />

LC<br />

4-pole<br />

3-pole LC<br />

LC<br />

Breaker<br />

LC<br />

Connection<br />

allowance<br />

15<br />

16<br />

112<br />

8<br />

LC<br />

(*1) 110-111<br />

112<br />

LC<br />

R1<br />

52<br />

30<br />

30<br />

φ18<br />

30<br />

28<br />

8.5<br />

68<br />

72<br />

2.5<br />

15<br />

54.5<br />

104.5<br />

2.5<br />

15<br />

M8 bolt<br />

5<br />

60<br />

90<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulation<br />

tube<br />

60<br />

3-pole<br />

90<br />

M4×0.7 taps or<br />

5mm-dia. hole<br />

Drilling plan<br />

4-pole<br />

86<br />

1.0mm clearance on each side<br />

of the handle frame.<br />

Front-panel cutout<br />

6<br />

Plug-in<br />

4-pole<br />

M5×0.8<br />

Terminal block mounting screw<br />

125<br />

Mounting plate<br />

90<br />

Breaker (plug-in terminal block)<br />

Plug-in terminal block<br />

30<br />

CL<br />

CL<br />

5.5 20<br />

CL<br />

11<br />

98<br />

190<br />

134<br />

16.5 max.<br />

LC<br />

54<br />

94 56<br />

56<br />

12<br />

12.5<br />

Details of terminal<br />

21<br />

89<br />

30<br />

M8 screw<br />

60<br />

95<br />

3-pole<br />

φ8.5<br />

Conductor drilling<br />

for direct connection<br />

30<br />

97<br />

3-pole<br />

60<br />

127<br />

4-pole<br />

6mm-dia. hole<br />

or M5×0.8 taps<br />

Drilling plan<br />

Note: (*1) It can respond to the attachment size of 110 and 111 both sides.<br />

Remarks: (1) NV125-CW is available in 3-pole only.<br />

(2) In case of the CE marking, outside sizes differ.<br />

112


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV250-CW<br />

NV250-HW<br />

Type NV250-SW<br />

NV250-SW<br />

Type name NV250-CW NV250-SW NV250-HW<br />

125 150 175 125 150 175 125 150 175 125 150 175<br />

Rated current In (Amp.)<br />

200 225 250 200 225 250 200 225 200 225<br />

Number of poles 3 3 4<br />

3<br />

Rated operational voltage Ue (V AC) (1)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

Note: (1) Rated operational voltage of time-delay type is for 200-440V.<br />

100–440<br />

Multi-voltage type<br />

30, 100 • 200 • 500<br />

Selectable<br />

30, 100 • 200 • 500<br />

Selectable<br />

30, 100 • 200 • 500<br />

Selectable<br />

0.04 0.04 0.04<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

15/8<br />

18/9<br />

35/18<br />

100–440 200–440 100–440 200–440<br />

Multi-voltage type Multi-voltage type Multi-voltage type Multi-voltage type<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

Mounting screw: M4×0.7×55 (3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (3P: 4pcs, 4P: 6pcs)<br />

4<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

50/13<br />

50/13<br />

100/25<br />

■Operating Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

1<br />

1.3<br />

Min.<br />

■Internal Accessories<br />

250A<br />

Types<br />

NV250-CW<br />

NV250-SW<br />

NV250-HW<br />

Max.<br />

125~<br />

225A<br />

Max.total<br />

breaking time<br />

Time-delay trip<br />

Instantaneous trip<br />

2 3 4 5 6 7 10 15 20 30 40<br />

×100% of rated current<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

25 50 100 500 1000<br />

■Temperature Characteristics<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 500 1000<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 500 1000<br />

Ground-fault current (% of rated current sensitivity)<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 500 1000<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

UVT<br />

MG EAL TBM<br />

Lead wire<br />

direction<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

Remark: (*1) refer to page 44.<br />

■External Accessories<br />

(*1)<br />

80<br />

–10 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■Internal Wiring Diagram<br />

Accessories<br />

Operating<br />

handle<br />

Handle lock<br />

device<br />

F<br />

S<br />

V<br />

R<br />

F2SW<br />

S2SW<br />

V2SW (*1)<br />

R2SW<br />

55<br />

57<br />

54<br />

58<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

Type name<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

Reference<br />

page<br />

70<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Ml<br />

Type name<br />

Ml-05SW3 (*3) 69<br />

Small TC-S TCS-2SW3W (*3)<br />

Large TC-L TCL-2SW3W (*3)<br />

Skeleton TTC TTC-2SW3 (*3)<br />

Rear BTC BTC-2SW3W (*3)<br />

Plug-in PTC PTC-2SW3W (*3)<br />

Reference<br />

page<br />

60<br />

Line side<br />

Magnetic<br />

device<br />

Test button<br />

Senstivity<br />

selector<br />

ZCT<br />

Load side<br />

Electrical<br />

operation device<br />

MDS-NV2SWE (*4)<br />

61<br />

Notes: (*1) Attach the letter "F" to the end of designation for a fixed type.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(*3) The designation depends on the number of poles. Refer to the reference page.<br />

(*4) Specify the working voltage.<br />

(*5) NV250-HW model cannot be produced.<br />

Leakage<br />

indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.<br />

113


Front connection<br />

Mounting hole<br />

Trip button<br />

LC<br />

CL<br />

22<br />

70<br />

Insulating barrier<br />

(removable)<br />

Sensitivity<br />

selector<br />

Operating time<br />

selector<br />

(for time-delay<br />

type)<br />

Leakage<br />

indication<br />

button<br />

Test button<br />

CL<br />

35<br />

105<br />

144<br />

100 165<br />

100<br />

Neutral<br />

pole<br />

102<br />

M8 bolt<br />

(Hex-soket)<br />

50<br />

φ8.5<br />

24<br />

45<br />

61<br />

68<br />

φ4.5<br />

30<br />

Solderless terminal<br />

for wire size<br />

125~175A 14~95mm 2<br />

200~250A 70~125mm 2<br />

Wire connection<br />

23 max.<br />

φ8.5<br />

10<br />

LC<br />

LC<br />

35<br />

Breaker<br />

35<br />

M4×0.7 screw<br />

or φ5<br />

CL<br />

126<br />

105 140<br />

4 72<br />

(Bus t max.=7)<br />

3-pole<br />

4-pole<br />

92<br />

Bus drilling for<br />

direct connection<br />

Drilling plan<br />

3-pole<br />

4-pole<br />

Rear connection<br />

4-pole<br />

Mounting plate<br />

t max.=3.2<br />

Insulating tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

LC<br />

Breaker<br />

LC<br />

3-pole<br />

CL<br />

LC<br />

Breaker<br />

LC<br />

Connection<br />

allowance<br />

144<br />

8<br />

CL<br />

126<br />

144<br />

CL<br />

R1<br />

52<br />

22<br />

20<br />

15<br />

6<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

ø24<br />

35<br />

32.5<br />

68<br />

72<br />

71<br />

106<br />

15<br />

φ9<br />

M8 bolt<br />

70<br />

105<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

M4×0.7<br />

screw<br />

or φ5<br />

Drilling plan<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-plate cutout<br />

6<br />

Plug-in<br />

200<br />

Mounting plate<br />

LC<br />

Plug-in terminal block<br />

14<br />

6<br />

28 144<br />

34.5<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

LC<br />

153<br />

CL<br />

CL<br />

Breaker (Terminal block)<br />

LC<br />

54<br />

58.5 80 58.5<br />

18<br />

86<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

direction only<br />

20<br />

70<br />

φ9<br />

M8 bolt<br />

Insulating barrier<br />

70<br />

107<br />

3-pole<br />

φ7<br />

105<br />

142<br />

4-pole<br />

Drilling plan<br />

Remarks: (1) NV250-CW are available in 3-pole only.<br />

(2) In case of the CE marking, outside sizes differ.<br />

114


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV250-SEW NV250-HEW<br />

Type NV250-SEW<br />

■Operating Characteristics<br />

Type name NV250-SEW NV250-HEW<br />

Rated current In (Amp.)<br />

Number of poles 3 4 3 4<br />

Rated operational voltage Ue (V AC) (1)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

125–225<br />

Adjustable<br />

100–440 100–440<br />

Multi-voltage type Multi-voltage type<br />

(30) 100 • 200 • 500<br />

Selectable<br />

(30) 100 • 200 • 500<br />

Selectable<br />

0.04 0.04<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

25/13<br />

30/15<br />

50/25<br />

Note: (1) Rated operational voltage of time-delay type is for 200-440V.<br />

125–225<br />

Adjustable<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

50/13<br />

50/13<br />

100/25<br />

Mounting screw:<br />

M4×0.7×55 (3P: 2pcs, 4P: 4pcs)<br />

Insulation barrier: (3P: 4pc, 4P: 6pcs)<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Pre-alarm<br />

pickup current IP<br />

Ir ×(0.70-0.75<br />

-0.8-0.85-0.9<br />

-0.95-1.0) ±10%<br />

Pre-alarm<br />

operating time TP<br />

TP = TL ±20%<br />

2<br />

(at 200%)<br />

0.6<br />

0.7<br />

INST pickup current Il<br />

In×(4~16) ±15%<br />

1 1.3 3 2 4<br />

Note) Instantaneous tripping current (×100% of In)<br />

LTD operating time TL<br />

12-60-80-100s ±20%<br />

(at 200%)<br />

×100% of Current setting<br />

Types<br />

NV250-SEW NV250-HEW<br />

Note)<br />

Current setting Ir Rated current In<br />

125~225A 225A<br />

(Adjustable)<br />

STD pickup current Is<br />

Ir ×(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

Max.total breaking<br />

time<br />

5 6 7 10 15 20 30 40<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

25 50 100 500 1000<br />

Rated current sensitivity<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 500 1000<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 500 1000<br />

Ground-fault current (% of rated current sensitivity)<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 500 1000<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

Remark: (*1) refer to page 44.<br />

AL AX UVT<br />

MG EAL TBM<br />

(*1)<br />

PAL<br />

Lead wire<br />

direction<br />

■Temperature Characteristics<br />

Derating of Load current (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

Rated ambient<br />

-10<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

■External Accessories<br />

■Internal Wiring Diagram<br />

Accessories<br />

Operating<br />

handle<br />

Handle lock<br />

device<br />

Type name<br />

Reference<br />

page<br />

F<br />

S<br />

V<br />

R<br />

F2SW<br />

S2SW<br />

V2SW (*1)<br />

R2SW<br />

55<br />

57<br />

54<br />

58<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

70<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

Ml Ml-05SW3 (*3) 69<br />

Small TC-S TCS-2SW3W (*3)<br />

Large TC-L TCL-2SW3W (*3)<br />

Skeleton TTC TTC-2SW3 (*3)<br />

Rear BTC BTC-2SW3W (*3)<br />

Plug-in PTC PTC-2SW3W (*3)<br />

Electrical<br />

operation device<br />

MDS-NVE2SWE (*4)<br />

Reference<br />

page<br />

60<br />

61<br />

Magnetic<br />

device<br />

Line side<br />

Magnetic<br />

device<br />

Characteristic<br />

setting part<br />

CT<br />

CT<br />

CT<br />

Test button<br />

ZCT<br />

Sensitivity<br />

selector<br />

Load side<br />

115<br />

Notes: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

(*3) The designation depends on the number of poles. Refer to the reference page.<br />

(*4) Specify the working voltage.<br />

(*5) NV250-HEW model cannot be produced.<br />

Leakage<br />

indication button


Front connection<br />

Insulating barrier<br />

(removable)<br />

M8 bolt<br />

(Hex-soket)<br />

24<br />

Note: The setting of selector is available by openning the upper cover.<br />

Mounting hole<br />

Trip<br />

button<br />

Test<br />

cover<br />

22<br />

70<br />

Leakage indicator<br />

button<br />

Current indication LED<br />

OVER<br />

PAL<br />

70%<br />

Sensitivity selector<br />

Operating<br />

time selector<br />

(for time-delay type)<br />

Test button<br />

Operating<br />

characteristics<br />

selector<br />

35<br />

105<br />

144<br />

165 100<br />

100<br />

Neutral<br />

pole<br />

102 (upper cover)<br />

50<br />

φ8.5<br />

68<br />

45<br />

61<br />

ø4.5<br />

30<br />

Solderless terminal<br />

for wire size<br />

125 175A 14 95mm 2<br />

200 225A 70 125mm 2<br />

Wire connection<br />

23max.<br />

ø8.5<br />

10<br />

35<br />

Breaker<br />

M4×0.7 taps<br />

or φ5<br />

35<br />

126<br />

105<br />

3-pole<br />

140<br />

4-pole<br />

4 72<br />

92<br />

(Bus t max.=7)<br />

Bus drilling for<br />

direct connection<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating<br />

tube<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Connection<br />

allowance<br />

144<br />

8<br />

126<br />

144<br />

R1<br />

52<br />

22<br />

20<br />

68<br />

72<br />

15<br />

71<br />

106<br />

15<br />

φ9<br />

M8 bolt<br />

6<br />

70<br />

105<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

3-pole<br />

ø24<br />

M4×0.7<br />

taps<br />

or φ5<br />

Drilling plan<br />

35<br />

35<br />

105<br />

4-pole<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-plate cutout<br />

32.5<br />

6<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal<br />

block<br />

Breaker (Terminal block)<br />

200<br />

14<br />

6<br />

28 144<br />

34.5<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

153<br />

54<br />

80 58.5<br />

58.5<br />

18<br />

86<br />

32<br />

M6<br />

Terminal block<br />

mounting screw<br />

20<br />

Stud attachable in this<br />

derection only<br />

70<br />

φ9<br />

M8 bolt<br />

Insulating<br />

barrier<br />

70<br />

φ7<br />

107<br />

3-pole<br />

Drilling plan<br />

105<br />

142<br />

4-pole<br />

116


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV125-RW<br />

Type name NV125-RW<br />

Type NV125-RW<br />

Rated current In (Amp.)<br />

Number of poles 3<br />

Rated operational voltage Ue (V AC) (2)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2 (Icu/Ics)<br />

Standard Attached Parts<br />

(Front connection)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

AC440V<br />

AC400V<br />

AC230V<br />

(15) 16 20 (30) 32 40<br />

50 (60) 63 (75) 80 100<br />

100–440<br />

Multi-voltage type<br />

(30) 100 • 200 • 500<br />

Selectable<br />

0.04<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

125/125<br />

125/125<br />

125/125<br />

Mounting screw : M4×0.7×73 (4pcs)<br />

Insulation barrier : (3P:4pcs, 4P:6pcs)<br />

Notes : (1) The Time-delayed types will be produced when they have the current specifications of 20A or more.<br />

(2) Rated operational voltage of time-delay type is for 200-440V.<br />

■Operating Characteristics<br />

4h<br />

4h<br />

4h<br />

2h<br />

2h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Type<br />

NV125-RW 16A~32A<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Type<br />

NV125-RW 40A~100A<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Type<br />

NV125-RW 32A<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.(60A~100A)<br />

Max. (40A~50A)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

1s<br />

1s<br />

1s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking<br />

time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

breaking time<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

6070<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40 50<br />

×100% of Rated current ×100% of Rated current<br />

×100% of Rated current<br />

■Earth-Leakage Tripping<br />

Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

AL<br />

AX<br />

UVT<br />

MG EAL TBM<br />

Operating handle<br />

Right-side<br />

mounting<br />

Lead wire<br />

direction<br />

■Temperature Characteristics<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

Rated ambient<br />

100<br />

90<br />

80<br />

–10 0 10 20 30 40 50<br />

Ambient temperature (°C)<br />

60<br />

25<br />

50 100 500 1000<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

Ground-fault current (% of rated current sensitivity)<br />

25 50 100 5001000<br />

Remark: (1) refer to page 44.<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Mechanical interlock<br />

F F1UW<br />

55<br />

S<br />

V<br />

S1SW<br />

V1UW<br />

57<br />

54<br />

R R1UW<br />

58<br />

MI<br />

Electrical operation device<br />

Type name<br />

MI-05SW3 (*1)<br />

—<br />

Reference<br />

page<br />

69<br />

—<br />

Terminal cover<br />

Accessories<br />

Small<br />

Large<br />

Skeleton<br />

Rear<br />

Plug-in<br />

Handle lock<br />

device<br />

TC-S<br />

TC-L<br />

TTC<br />

BTC<br />

(*2)<br />

HL<br />

HL-S<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) HLF and HLS types are used for OFF-lock, and HLN types for ON-lock.<br />

Type name<br />

TCS-1SW3W (*1)<br />

TCL-1SW3W (*1)<br />

TTC-1SW3 (*1)<br />

BTC-1SW3W (*1)<br />

PTC PTC-1SW3W (*1)<br />

LC LC-1SW<br />

HLF-1SW<br />

HLN-1SW<br />

HLS-1SW<br />

Reference<br />

page<br />

60<br />

70<br />

■Internal Wiring Diagram<br />

Line side<br />

Magnetic<br />

device<br />

Leakage<br />

indication button<br />

Test button<br />

Senstivity<br />

selector<br />

ZCT<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.<br />

Load side<br />

117


Front connection<br />

191<br />

130<br />

61<br />

173<br />

Mounting hole<br />

CL<br />

CL<br />

Sensitivity current<br />

selector<br />

Operating time<br />

selector<br />

(time-delay type)<br />

Leakage<br />

indication button<br />

84<br />

M8 screw<br />

50<br />

24<br />

φ8.5<br />

8<br />

CL<br />

LC<br />

Breaker<br />

171-172<br />

(*1)<br />

Test button<br />

Trip<br />

button<br />

22<br />

60<br />

90<br />

45<br />

61<br />

68<br />

19 max.<br />

(Conductor thickness t=5 max.)<br />

30<br />

M4×7 taps or<br />

5mm-dia. hole<br />

4<br />

72<br />

Conductor drilling for direct connection<br />

90<br />

Drilling plan<br />

Rear connection<br />

Mounting plate<br />

t=3.2 max.<br />

102<br />

52<br />

Stud rotatble<br />

by 90°<br />

CL<br />

Breaker<br />

LC<br />

Breaker<br />

CL<br />

Mounting base<br />

Connection<br />

15 allowance<br />

16<br />

173<br />

CL<br />

8<br />

CL<br />

171-172<br />

(*1)<br />

173<br />

LC<br />

R1<br />

4.5<br />

52<br />

8.5<br />

68<br />

72<br />

2.5<br />

15<br />

54.5<br />

104.5<br />

2.5<br />

15<br />

M8 bolt<br />

5 60<br />

M4×0.7<br />

60<br />

breaker<br />

mounting screw<br />

Insulation<br />

tube<br />

30<br />

Drilling plan<br />

φ18<br />

M4×7 taps or<br />

5mm-dia. hole<br />

86<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

Front-panel cutout<br />

6<br />

Plug-in<br />

Mounting plate<br />

M5×0.8<br />

Terminal block mounting screw<br />

Breaker<br />

(plug-in terminal block)<br />

Plug-in terminal<br />

block<br />

CL<br />

LC<br />

LC<br />

11<br />

159<br />

251<br />

LC<br />

195<br />

5.5<br />

20<br />

16.5 max.<br />

12<br />

LC<br />

115<br />

56 155<br />

56<br />

21<br />

89<br />

30<br />

M8 screw<br />

60<br />

95<br />

12.5<br />

φ8.5<br />

30<br />

97<br />

6mm-dia. hole<br />

or M5×0.8 taps<br />

Details of terminal<br />

Conductor drilling<br />

for direct connection<br />

Drilling plan<br />

Note: (*1) It can respond to the attachment size of 171 and 172 both sides.<br />

Remark: In case of the CE marking, outside sizes differ.<br />

118


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV250-RW<br />

Type name NV250-RW<br />

Type NV250-RW<br />

Rated current In (Amp.)<br />

Number of poles 3<br />

Rated operational voltage Ue (V AC) (1)<br />

High-speed type<br />

Time-delay type<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC 60947-2 (Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Inertial non-operating time at 2I∆n (s)<br />

Standard Attached Parts (Front connection)<br />

AC440V<br />

AC400V<br />

AC230V<br />

Note: (1) Rated operational voltage of time-delay type is for 200-440V<br />

125 150 175<br />

200 225<br />

100–440<br />

Multi-voltage type<br />

(30) 100 • 200 • 500<br />

Selectable<br />

0.04<br />

100 • 200 • 500<br />

Selectable<br />

0.45 • 1.0 • 2.0<br />

Selectable<br />

(0.1 • 0.5 • 1.0)<br />

Button<br />

125/125<br />

125/125<br />

125/125<br />

Mounting screw : M4 × 0.7 × 55 (2pcs),<br />

M4 × 0.7 × 73 (2pcs)<br />

Insulation barrier : (4pcs)<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Min.<br />

Type<br />

NV250-RW<br />

Max.<br />

Max.total<br />

breaking time<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

2s(MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.3 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of Rated current<br />

■Internal Accessories<br />

25 50 100 500 1000<br />

25 50 100 5001000<br />

25 50 100 5001000<br />

Ground-fault current (% of rated current sensitivity)<br />

■Ambient Compensating Curve<br />

25 50 100 5001000<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL AX UVT MG EAL TBM<br />

Lead wire<br />

direction<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

Remark: (1) refer to page 44.<br />

■External Accessories<br />

80<br />

–10 0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■Internal Wiring Diagram<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

F<br />

S<br />

V<br />

F2UW<br />

S2SW<br />

V2UW<br />

55<br />

57<br />

54<br />

R R2UW<br />

58<br />

LC<br />

(*2)<br />

HL<br />

HL-S<br />

Type name<br />

LC-2SW<br />

HLF-2SW<br />

HLN-2SW<br />

HLS-2SW<br />

Reference<br />

page<br />

70<br />

Terminal cover<br />

Accessories<br />

Mechanical<br />

interlock<br />

Type name<br />

MI MI-05SW3 (*1)<br />

Small TC-S TCS-2SW3W (*1)<br />

Large TC-L TCL-2SW3W (*1)<br />

Skeleton TTC TTC-2SW3 (*1)<br />

Rear BTC BTC-2SW3W (*1)<br />

Plug-in PTC PTC-2SW3W (*1)<br />

Electrical<br />

operation device<br />

Reference<br />

page<br />

69<br />

60<br />

— —<br />

Line side<br />

Magnetic<br />

device<br />

Test button<br />

Senstivity<br />

selector<br />

ZCT<br />

Load side<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

(*2) HLF types are used for OFF-lock, and HLN types for ON-lock.<br />

Leakage<br />

indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.<br />

119


Front connection<br />

100 240<br />

100<br />

Mounting hole<br />

165 75<br />

219<br />

Trip<br />

Button<br />

CL<br />

CL<br />

22<br />

70<br />

Insulating barrier<br />

(removable)<br />

Sensitivity selector<br />

Operating time selector<br />

(for time-delay type)<br />

Leakage indication<br />

button<br />

Test button<br />

165 75<br />

M8 bolt<br />

(Hex-socket)<br />

28<br />

102<br />

50<br />

φ8.5<br />

45<br />

61<br />

68<br />

24<br />

φ4.5<br />

Solderless terminal<br />

for wire size<br />

125~175A 14~95mm 2<br />

200~225A 70~125mm 2<br />

Wire connection<br />

23 max<br />

φ8.5<br />

10<br />

(Bus t max.=7)<br />

LC<br />

LC<br />

35<br />

Drilling plan<br />

Breaker<br />

201<br />

M4×0.7 screw<br />

or φ5<br />

105<br />

4<br />

72<br />

92<br />

Bus drilling for<br />

direct connection<br />

Rear connection<br />

Mounting plate<br />

t max.=3.2<br />

Insulating<br />

tube<br />

Stud can be<br />

rotated 90°<br />

CL<br />

Breaker<br />

CL<br />

Breaker<br />

73<br />

108<br />

LC<br />

LC<br />

11.5<br />

CL<br />

Connection<br />

219<br />

8<br />

CL<br />

201<br />

219<br />

R1<br />

52<br />

allowance<br />

22<br />

20<br />

68<br />

72<br />

15<br />

71<br />

106<br />

15<br />

φ9<br />

M8 bolt<br />

6<br />

70<br />

M4×0.7<br />

breaker<br />

mounting screw<br />

Insulating<br />

tube<br />

35<br />

70<br />

Drilling plan<br />

ø24<br />

M4×0.7<br />

screw<br />

or φ5<br />

100<br />

1mm clearance<br />

on each side<br />

of handle<br />

Front-plate cutout<br />

6<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal<br />

block<br />

34.5<br />

LC<br />

CL<br />

Breaker (Terminal block)<br />

275<br />

CL<br />

14<br />

219<br />

70<br />

15<br />

Connection<br />

allowance<br />

22<br />

CL<br />

28<br />

58.5<br />

129<br />

155 58.5<br />

6<br />

153<br />

18<br />

86 32<br />

M6<br />

Terminal block<br />

mounting screw<br />

Stud attachable in this<br />

direction only<br />

20<br />

70<br />

φ9<br />

M8 bolt<br />

Insulating<br />

barrier<br />

70<br />

107<br />

Drilling plan<br />

φ7<br />

Remark: In case of the CE marking, outside sizes differ.<br />

120


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV400-CW<br />

NV400-SW<br />

Type NV400-SW<br />

Type name<br />

NV400-CW NV400-SW<br />

Number of poles<br />

3<br />

Rated operational voltage Ue (V AC) (1)<br />

100-440 Multi-voltage type<br />

Rated current In (Amp.)<br />

250 300 350 400<br />

High-speed Rated current sensitivity I∆n (mA) (30) 100 · 200 · 500 Selectable<br />

type<br />

Max. operating time at 5I∆n (s)<br />

0.04<br />

Rated current sensitivity I∆n (mA) (100 · 200 · 500 Selectable)<br />

Time-delay<br />

type<br />

Max. operating time at 2I∆n (s) (0.45 · 1.0 · 2.0 Selectable)<br />

Inertial non-operating time at 2I∆n (s)<br />

(0.1 · 0.5 · 1.0)<br />

Earth-leakage indication system<br />

Button<br />

Rated short-circuit<br />

440V<br />

25/13<br />

42/42<br />

breaking capacity (kA)<br />

IEC60947-2<br />

AC 400V<br />

36/18<br />

45/45<br />

(lcu/lcs)<br />

230V<br />

50/25<br />

85/85<br />

Standard Attached Parts<br />

Mounting screw: M6×60 (4pcs)<br />

(Front connection)<br />

Insulation barrier: (4pcs)<br />

Note: (1) Rated operational voltage of time-delay type is for 200-440V.<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

4h<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Min.<br />

Types<br />

NV400-CW<br />

NV400-SW<br />

Max.<br />

NV400-CW<br />

NV400-SW<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

2s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total breaking time<br />

25 50 100 500 1000<br />

Ground-fault current<br />

(×100% of rated current sensitivity)<br />

500<br />

25 100 1000<br />

50 500<br />

25 100 1000<br />

50<br />

50 500<br />

25 100 1000<br />

Ground-fault current Ground-fault current Ground-fault current<br />

(×100% of rated current sensitivity) (×100% of rated current sensitivity) (×100% of rated current sensitivity)<br />

0.02s<br />

0.01s<br />

100<br />

Time-delay trip<br />

Instantaneous trip<br />

125 200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

Current (×100% of rated current)<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL AX SHT or UVT MG<br />

EAL<br />

TBM<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Reference ambient<br />

temperature<br />

80<br />

0<br />

10<br />

20<br />

30<br />

40<br />

50<br />

60<br />

Ambient temperature (°C)<br />

Remark: (1) refer to page 46 and 47.<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Type name<br />

Reference<br />

page<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

■Internal Wiring Diagram<br />

Test button<br />

Operating handle<br />

F<br />

S<br />

V<br />

F4SWNV<br />

S4CW, S4SW<br />

V4SWNV,V4SWFNV<br />

Mechanical interlock (MI) MI-4SW3 (*1)<br />

Auxiliary handle (HT) HT-4CW, HT-4SW<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Large<br />

Skeleton<br />

Rear<br />

(TC-L) TCL-4SW3<br />

(TTC) TTC-4SW3<br />

(BTC) BTC-4SW3<br />

Handle<br />

lock device<br />

HL<br />

HL-S<br />

HL-4CW, HL-4SW<br />

HLS-4SW<br />

Electrical operation device<br />

Notes: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

Terminal cover<br />

60<br />

70<br />

61<br />

Line side<br />

Magnetic<br />

device<br />

Sensitivity<br />

selector<br />

ZCT<br />

Load side<br />

Leakage indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.<br />

121


Front connection<br />

110<br />

Insulating barrier (removable)<br />

28<br />

16<br />

43<br />

Conductor thickness<br />

t=8 max.<br />

94.5<br />

44<br />

8<br />

LC<br />

Breaker<br />

LC<br />

Breaker<br />

Mounting hole<br />

LC<br />

Trip button<br />

Sensitivity current selector<br />

Operating time selector<br />

(Time-delay type)<br />

Leakage indication button<br />

Test button<br />

257<br />

102 39<br />

39<br />

ø12.5<br />

47<br />

ø7<br />

25<br />

12<br />

ø10.5<br />

LC<br />

194<br />

LC<br />

R6<br />

92<br />

51<br />

112<br />

140<br />

ø14<br />

M12 bolt<br />

5<br />

Conductor thickness t=8 max.<br />

44 Conductor drilling for direct connection<br />

97<br />

103<br />

107<br />

155(NV400-SP)<br />

134(NV400-CP)<br />

44<br />

Drilling plan<br />

M6 tap or ø7<br />

118<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

Front-panel cutout<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Mounting plate<br />

Stud can be rotated 90°C<br />

Breaker<br />

Groove for reducing heat by overcurrent<br />

LC<br />

8<br />

Line side<br />

6-ø35<br />

8<br />

24<br />

LC<br />

Connection<br />

allowance<br />

25 20 20<br />

225<br />

265<br />

24<br />

14<br />

M6 tap or ø7<br />

LC<br />

194<br />

225<br />

194<br />

225<br />

4-M6 tap or ø7<br />

113<br />

10<br />

26<br />

ø13 M12 bolt<br />

128<br />

83<br />

8<br />

87<br />

M6 screw for<br />

mounting breaker<br />

Insulation tube<br />

44<br />

87<br />

ø35<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

Drilling plan<br />

Load side<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

6<br />

Plug-in<br />

280<br />

Plug-in terminal block<br />

LC<br />

24<br />

Mounting plate<br />

M8 terminal block<br />

mounting screw<br />

35<br />

225<br />

Connection allowance<br />

LC<br />

LC<br />

LC<br />

Breaker<br />

135<br />

163 55<br />

121<br />

18<br />

8<br />

28<br />

160<br />

79<br />

15<br />

24<br />

28<br />

ø13 M12 bolt<br />

87<br />

Stud attachable in<br />

this direction only<br />

Insulating barrier<br />

ø10<br />

44<br />

136<br />

55<br />

Drilling plan<br />

122


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV400-SEW<br />

NV400-HEW<br />

NV400-REW<br />

Type NV400-SEW<br />

Type name<br />

Number of poles<br />

Rated operational voltage Ue (V AC)<br />

Rated current In (Amp.)<br />

High-speed<br />

type<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Time-delay<br />

type<br />

Max. operating time at 5I∆n (s)<br />

Max. inertial non-operating time at 2I∆n (s)<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC60947-2<br />

(Icu/Ics)<br />

AC<br />

440V<br />

400V<br />

230V<br />

NV400-SEW NV400-HEW NV400-REW<br />

3 4 3 4 3<br />

42/42<br />

50/50<br />

85/85<br />

100-440 Multi-voltage type<br />

200-400 adjustable<br />

(30) 100 · 200 · 500 Selectable<br />

0.04<br />

(100 · 200 · 500 Selectable)<br />

(0.45 · 1.0 · 2.0 Selectable)<br />

(0.1 · 0.5 · 1.0)<br />

Button<br />

65/65<br />

70/70<br />

100/100<br />

Standard Attached Parts<br />

Mounting screw: M6×72 (4pcs)<br />

(Front connection)<br />

Insulation barrier: (3P: 4pcs, 4P: 6pcs)<br />

Note: (1) Rated operational voltage of time-delay type is for 200-440V.<br />

125/63<br />

125/63<br />

150/75<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

10h<br />

5h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

Pre-alarm<br />

pickup current Ip<br />

Ir x (0.70-0.75-0.8-<br />

0.85-0.9-0.95<br />

-1.0) ±10%<br />

LTD operating time<br />

at 125%<br />

1000s (TL=150s set)<br />

670s (TL=100s set)<br />

400s (TL= 60s set)<br />

80s (TL= 12s set)<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Types<br />

NV400-SEW<br />

NV400-HEW<br />

NV400-REW<br />

Current setting Rated current<br />

Ir: 200-400A In: 400A<br />

(Adjustable)<br />

LTD operating time TL<br />

12-60-100-150s ±20%<br />

(at 200%)<br />

STD pickup current Is<br />

Ir x (2-2.5-3-3.5-4-<br />

5-6-7-8-10) ±15%<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

2s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ±20% 2<br />

(at 200%)<br />

STD operating time Ts<br />

0.3 ± 0.06 s<br />

0.2 ± 0.04 s<br />

0.1 ± 0.03 s<br />

0.06 ± 0.02 s<br />

25 50 100 500 1000<br />

Ground-fault current<br />

(×100% of rated current sensitivity)<br />

500<br />

25 100 1000<br />

50 500<br />

25 100 1000<br />

50<br />

50 500<br />

25 100 1000<br />

Ground-fault current Ground-fault current Ground-fault current<br />

(×100% of rated current sensitivity) (×100% of rated current sensitivity) (×100% of rated current sensitivity)<br />

0.02s<br />

0.01s<br />

INST pickup current II<br />

x 4 ~ x16 ±15%<br />

(Magnification to In)<br />

60 70 100 125 200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

Current setting (% to Ir)<br />

Instantaneous tripping current (% to In)<br />

Max. total<br />

breaking time<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

AL AX SHT or UVT MG EAL TBM<br />

PAL<br />

Type name<br />

Operating handle<br />

F<br />

S<br />

V<br />

F4SWNV<br />

S4SW<br />

V4SWNV,V4SWFNV<br />

Mechanical interlock (MI) MI-4SW3 (*2)<br />

Auxiliary handle (HT) HT-4SW<br />

Note: (*1) This is for NV400-SEW.<br />

(*2) The designation depends on the number of poles. Refer to the reference page.<br />

TI<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Reference<br />

page<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Terminal cover<br />

Large<br />

Skeleton<br />

Rear<br />

Handle<br />

lock device<br />

Accessories<br />

Electrical operation<br />

device<br />

Lead wire<br />

direction<br />

Remark: (1) Instead of EAL and TBM, pre-alarm module (PAL) or trip indicator (TI) can be attached.<br />

(2) refer to page 46 and 47.<br />

Type name<br />

(TC-L) TCL-4SW3 (*1) (*2)<br />

(TTC) TTC-4SW3 (*2)<br />

(BTC) BTC-4SW3 (*1) (*2)<br />

HL HL-4SW<br />

HL-S HLS-4SW<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

■Current reducing curve<br />

Continuous load current (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

Rated ambient<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

■Internal Wiring Diagram<br />

Magnetic<br />

device<br />

N<br />

Line side<br />

Magnetic<br />

device<br />

Characteristic<br />

setting part<br />

CT<br />

CT<br />

CT<br />

Test button<br />

ZCT<br />

Sensitivity<br />

selector<br />

In case of 4P<br />

Load side<br />

123<br />

Leakage indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.


Front connection<br />

110<br />

Mounting hole<br />

LC<br />

Trip button<br />

51<br />

112<br />

140<br />

3-pole<br />

Rear connection<br />

Insulating barrier (removable)<br />

Sensitivity current<br />

selector<br />

Operating time selector<br />

(Time-delay type)<br />

Leakage indication<br />

button<br />

Test button<br />

ø14<br />

M12 bolt<br />

Mounting plate<br />

LC<br />

56<br />

168<br />

185<br />

196<br />

4-pole<br />

Stud can be<br />

rotated 90°C<br />

28<br />

16<br />

Conductor thickness<br />

t=8 max.<br />

43<br />

257<br />

Neutral pole<br />

3-pole<br />

102 39<br />

39<br />

4-pole<br />

8<br />

94.5<br />

ø12.5<br />

ø7<br />

44<br />

97<br />

103<br />

5 107<br />

155<br />

44<br />

59<br />

C<br />

Breaker<br />

L<br />

LC Breaker<br />

LC<br />

LC<br />

LC<br />

25<br />

44 M6 tap or ø7 44<br />

118<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

3-pole<br />

4-pole<br />

Front-panel cutout<br />

Drilling plan<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Line side<br />

Breaker Groove for reducing<br />

LC heat by overcurrent C L<br />

6-ø35<br />

12<br />

ø10.5<br />

Conductor thickness t=8 max.<br />

Conductor drilling for direct connection<br />

8<br />

194<br />

8<br />

R6<br />

4-pole<br />

3-pole<br />

24<br />

92<br />

Connection<br />

allowance<br />

M6 tap or ø7<br />

LC<br />

25 20 20<br />

225<br />

265<br />

14<br />

LC<br />

194<br />

225<br />

24<br />

4-M6 tap or ø7<br />

194<br />

225<br />

113<br />

10<br />

26<br />

ø13<br />

M12 bolt<br />

128<br />

83<br />

8<br />

87<br />

130.5<br />

M6 screw for<br />

mounting breaker<br />

Insulation tube<br />

44 ø35 44<br />

87<br />

43.5<br />

130.5<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

Load side<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

6<br />

Plug-in<br />

Plug-in terminal block<br />

Mounting plate<br />

35<br />

4-pole<br />

3-pole<br />

LC<br />

LC<br />

Breaker<br />

LC<br />

280<br />

LC<br />

24<br />

M8 terminal block<br />

mounting screw<br />

225<br />

Connection<br />

allowance<br />

LC<br />

135<br />

163 55<br />

121<br />

18<br />

8<br />

28<br />

160<br />

79<br />

15<br />

24<br />

28<br />

ø13<br />

M12 bolt<br />

87<br />

130.5<br />

Stud attachable<br />

in this direction only<br />

Insulating barrier<br />

ø10<br />

44 87<br />

136<br />

181<br />

3-pole<br />

4-pole<br />

55<br />

Drilling plan<br />

124


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV630-CW<br />

NV630-SW<br />

Type NV630-SW<br />

Type name<br />

Number of poles<br />

Rated operational voltage Ue (V AC)<br />

Rated current In (Amp.)<br />

High-speed<br />

type<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC60947-2<br />

(Icu/Ics)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Time-delay<br />

type<br />

Max. operating time at 5I∆n (s)<br />

Max. inertial non-operating time at 2I∆n (s)<br />

Earth-leakage indication system<br />

Standard Attached Parts<br />

(Front connection)<br />

AC<br />

440V<br />

400V<br />

230V<br />

NV630-CW NV630-SW<br />

3<br />

100-440 Multi-voltage type<br />

500 600 630<br />

100 · 200 · 500 Selectable<br />

0.04<br />

100 · 200 · 500 Selectable<br />

0.45 · 1.0 · 2.0 Selectable<br />

0.1 · 0.5 · 1.0<br />

Button<br />

36/18<br />

42/42<br />

36/18<br />

50/50<br />

50/25<br />

85/85<br />

Mounting screw: M6×72 (4pcs)<br />

Insulation barrier: (4pcs)<br />

■Operating Characteristics<br />

■Earth-Leakage Tripping Characteristics<br />

4h<br />

2h<br />

Operating time<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Min.<br />

Types<br />

NV630-CW NV630-SW<br />

Max.<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

2s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total breaking time<br />

25 50 500<br />

100 1000<br />

500<br />

25 100 1000<br />

50 500<br />

25 100 1000<br />

50<br />

50 500<br />

25 100 1000<br />

Ground-fault current Ground-fault current Ground-fault current Ground-fault current<br />

(×100% of rated current sensitivity) (×100% of rated current sensitivity) (×100% of rated current sensitivity) (×100% of rated current sensitivity)<br />

0.02s<br />

0.01s<br />

100 125<br />

Time-delay trip<br />

Instantaneous trip<br />

200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

% of rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL AX SHT or UVT MG<br />

EAL<br />

TBM<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Reference ambient<br />

temperature<br />

80<br />

0<br />

10<br />

20<br />

30<br />

40<br />

50<br />

60<br />

Ambient temperature (°C)<br />

Remark: (1) refer to page 46 and 47.<br />

■External Accessories<br />

External Accessories (An order for<br />

Accessories<br />

Type name<br />

Operating handle<br />

F<br />

S<br />

V<br />

F4SWWNV<br />

S4SW<br />

V4SW, V4SWF<br />

Mechanical interlock (MI) MI-4SW3<br />

Auxiliary handle (HT) HT-4SW<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Reference<br />

page<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Large<br />

Skeleton<br />

Rear<br />

(TC-L) TCL-4SW3<br />

(TTC) TTC-4SW3<br />

(BTC) BTC-4SW3<br />

Handle<br />

lock device<br />

HL<br />

HL-S<br />

HL-4SW<br />

HLS-4SW<br />

Electrical operation device<br />

Terminal cover<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

■Internal Wiring Diagram<br />

Line side<br />

Magnetic<br />

device<br />

Test button<br />

Sensitivity<br />

selector<br />

ZCT<br />

Load side<br />

Leakage indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.<br />

125


Front connection<br />

94.5<br />

110<br />

Insulating barrier<br />

(removable)<br />

Sensitivity<br />

selector<br />

28<br />

16<br />

43<br />

Bus t max.=10<br />

39<br />

8<br />

44<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Mounting<br />

hole<br />

Trip<br />

button<br />

51<br />

112<br />

140<br />

Operating-time<br />

selector<br />

(time-delay type)<br />

Leakage-indicator<br />

button<br />

Test button<br />

ø14<br />

M12 bolt<br />

56<br />

168<br />

185<br />

196<br />

257<br />

Neutral<br />

Pole<br />

102<br />

39<br />

ø12.5<br />

97<br />

103<br />

5 107<br />

155<br />

59<br />

ø7<br />

44<br />

30<br />

12<br />

Bus t max.=10<br />

ø10.5<br />

Bus drilling for<br />

direct connection<br />

44<br />

M6 screw<br />

or ø7<br />

44<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

194<br />

R6<br />

118<br />

1mm clearance on each<br />

side of handle<br />

Front-plate cutout<br />

92<br />

3-pole<br />

4-pole<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Mounting<br />

plate<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

Eddy-current<br />

heat-reducing slit<br />

8<br />

Line side<br />

6-ø35<br />

Connection<br />

allowance<br />

25 20 20<br />

225<br />

265<br />

14<br />

M6 screw<br />

or ø7<br />

194<br />

225<br />

24<br />

194<br />

225<br />

113<br />

10<br />

32<br />

ø13<br />

M12 bolt<br />

128<br />

83<br />

8<br />

M6<br />

breaker mounting<br />

87<br />

screw<br />

Insulated tube<br />

44<br />

87<br />

130.5<br />

ø35<br />

44<br />

43.5<br />

130.5<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

6<br />

Plug-in<br />

Plug-in terminal<br />

block<br />

Mounting plate<br />

4-pole<br />

3-pole<br />

Breaker<br />

35<br />

8<br />

24<br />

4-M6 tap or ø7<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

Load side<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

280<br />

M8<br />

terminal block<br />

25 Mounting screw<br />

10<br />

28 225<br />

Connection<br />

allowance<br />

160<br />

93<br />

25<br />

ø10<br />

135<br />

163 55<br />

55<br />

18<br />

121<br />

20<br />

ø13<br />

M12 bolt<br />

30<br />

110<br />

165.5<br />

Stud attachable in<br />

this direction only<br />

Insulating barrier<br />

44 87<br />

136 181<br />

3-pole<br />

4-pole<br />

Note: NV630-CW, NV630-SW, NV630-HEW is only the pole of 3.<br />

Drilling plan<br />

126


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV630-SEW<br />

NV630-HEW<br />

Type NV630-SEW<br />

Type name<br />

Number of poles<br />

Rated operational voltage Ue (V AC) (*1)<br />

Rated current In (Amp.)<br />

High-speed Rated current sensitivity I∆n (mA)<br />

type<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Time-delay<br />

type<br />

Max. operating time at 5I∆n (s)<br />

Max. inertial non-operating time at 2I∆n (s)<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

breaking capacity (kA)<br />

IEC60947-2<br />

(Icu/Ics)<br />

Standard Attached Parts<br />

(Front connection)<br />

AC<br />

440V<br />

400V<br />

230V<br />

Notes: (*1) Rated operational voltage of time-delay type is for 200-440V.<br />

NV630-SEW NV630-HEW<br />

3 4 3<br />

100-440 Multi-voltage type<br />

42/42<br />

50/50<br />

85/85<br />

300-630 adjustable<br />

(30) 100 · 200 · 500 Selectable<br />

0.04<br />

(100 · 200 · 500 Selectable)<br />

(0.45 · 1.0 · 2.0 Selectable)<br />

(0.1 · 0.5 · 1.0)<br />

Button<br />

65/65<br />

70/70<br />

100/100<br />

Mounting screw: M6×72 (4pcs)<br />

Insulation barrier: (3P: 4pcs, 4P: 6pcs)<br />

■Operating Characteristics<br />

10h<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

Pre-alarm<br />

pickup current Ip<br />

Ir x(0.7-0.75-0.8-0.85<br />

-0.9-0.95-1.0)±10%<br />

INST pickup current II<br />

In x(4~15) ±15%<br />

(Magnification to In)<br />

LTD operating time TL<br />

12-60-100-150s ±20%<br />

(at 200%)<br />

STD pickup current Isd<br />

Ir x(2-2.5-3-3.5-4<br />

-5-6-7-8-10) ±15%<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

Max.total<br />

breaking time<br />

70 60 125 100 300<br />

700<br />

200 400 3000<br />

500 600 1000 1500 2000 4000<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

■External Accessories<br />

(An order for<br />

5h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Accessories<br />

Pre-alarm<br />

operating time Tp<br />

TL<br />

Tp= ±20% 2<br />

(at 200%)<br />

Current (% to Ir)<br />

Instantaneous Tripping Current (% to In)<br />

Types<br />

NV630-SEW NV630-HEW<br />

AL AX SHT or UVT MG EAL TBM<br />

PAL<br />

Type name<br />

Operating handle<br />

F<br />

S<br />

V<br />

F4SWNV<br />

S4SW<br />

V4SWF, V4SW<br />

Mechanical interlock (MI) MI-4SW3 (*1)<br />

Auxiliary handle (HT) HT-4SW<br />

LTD operating time<br />

at-125%<br />

1000s(TL=150s set)<br />

570s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Note: (*1) The designation depends on the number of poles. Refer to the reference page.<br />

TI<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

Reference<br />

page<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Terminal cover<br />

Current setting<br />

Ir:300~630A<br />

(Adjustable)<br />

Large<br />

Skeleton<br />

Rear<br />

Handle<br />

lock device<br />

Accessories<br />

Electrical operation<br />

device<br />

Rated Current<br />

In:630A<br />

Lead wire<br />

direction<br />

Remark: (1) Instead of EAL and TBM, pre-alarm module (PAL) or trip indicator (TI) can be attached.<br />

(2) refer to page 46 and 47.<br />

Type name<br />

(TC-L) TCL-4SW3 (*1)<br />

(TTC) TTC-4SW3 (*1)<br />

(BTC) BTC-4SW3 (*1)<br />

HL HL-4SW<br />

HL-S HLS-4SW<br />

Operating time<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

25 50 500<br />

100 1000<br />

500<br />

25 100 1000<br />

50 500<br />

25 100 1000<br />

50<br />

50 500<br />

25 100 1000<br />

Ground-fault current Ground-fault current Ground-fault current Ground-fault current<br />

(×100% of rated current sensitivity) (×100% of rated current sensitivity) (×100% of rated current sensitivity) (×100% of rated current sensitivity)<br />

■Current reducing curve<br />

Continuous load current (%)<br />

■Internal Wiring Diagram<br />

Magnetic<br />

device<br />

N<br />

Line side<br />

Magnetic<br />

device<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Characteristic<br />

setting part<br />

CT<br />

CT<br />

CT<br />

Rated nonoperating current<br />

Rated ambient<br />

Time-delay type<br />

1s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Test button<br />

ZCT<br />

Sensitivity<br />

selector<br />

Rated nonoperating current<br />

In case of 4P<br />

Time-delay type<br />

2s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Load side<br />

127<br />

Leakage indication button<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.


Front connection<br />

94.5<br />

110<br />

Insulating barrier<br />

(removable)<br />

Sensitivity<br />

selector<br />

28<br />

16<br />

43<br />

Bus t max.=10<br />

39<br />

8<br />

44<br />

Breaker<br />

4-pole<br />

3-pole<br />

Breaker<br />

Mounting<br />

hole<br />

Trip<br />

button<br />

51<br />

112<br />

140<br />

Operating-time<br />

selector<br />

(time-delay type)<br />

Leakage-indicator<br />

button<br />

Test button<br />

ø14<br />

M12 bolt<br />

56<br />

168<br />

185<br />

196<br />

257<br />

Neutral<br />

Pole<br />

102<br />

39<br />

ø12.5<br />

97<br />

103<br />

5 107<br />

155<br />

59<br />

ø7<br />

44<br />

30<br />

12<br />

Bus t max.=10<br />

ø10.5<br />

Bus drilling for<br />

direct connection<br />

44<br />

M6 screw<br />

or ø7<br />

44<br />

3-pole<br />

4-pole<br />

Drilling plan<br />

194<br />

R6<br />

118<br />

1mm clearance on each<br />

side of handle<br />

Front-plate cutout<br />

92<br />

3-pole<br />

4-pole<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Mounting<br />

plate<br />

Stud can be<br />

rotated 90°<br />

4-pole<br />

3-pole<br />

Breaker<br />

Eddy-current<br />

heat-reducing slit<br />

8<br />

Line side<br />

6-ø35<br />

Connection<br />

allowance<br />

25 20 20<br />

225<br />

265<br />

14<br />

M6 screw<br />

or ø7<br />

194<br />

225<br />

24<br />

194<br />

225<br />

113<br />

10<br />

32<br />

ø13<br />

M12 bolt<br />

128<br />

83<br />

8<br />

M6<br />

breaker mounting<br />

87<br />

screw<br />

Insulated tube<br />

44<br />

87<br />

130.5<br />

ø35<br />

44<br />

43.5<br />

130.5<br />

3-pole<br />

Drilling plan<br />

4-pole<br />

6<br />

Plug-in<br />

Plug-in terminal<br />

block<br />

Mounting plate<br />

4-pole<br />

3-pole<br />

Breaker<br />

35<br />

8<br />

24<br />

4-M6 tap or ø7<br />

11 11<br />

44<br />

87<br />

24 24<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

Load side<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

280<br />

M8<br />

terminal block<br />

25 Mounting screw<br />

10<br />

28 225<br />

Connection<br />

allowance<br />

160<br />

93<br />

25<br />

ø10<br />

135<br />

163 55<br />

55<br />

18<br />

121<br />

20<br />

ø13<br />

M12 bolt<br />

30<br />

110<br />

165.5<br />

Stud attachable in<br />

this direction only<br />

Insulating barrier<br />

44 87<br />

136 181<br />

3-pole<br />

4-pole<br />

Note: NV630-CW, NV630-SW, NV630-HEW is only the pole of 3.<br />

Drilling plan<br />

128


6. Characteristics and Dimensions<br />

Earth-Leakage Circuit Breakers<br />

NV800-SEW<br />

NV800-HEW<br />

Type NV800-SEW<br />

Type name<br />

Number of poles<br />

Rated operational voltage Ue (V AC)<br />

Rated current In (Amp.)<br />

High-speed<br />

type<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time at 5I∆n (s)<br />

Rated current sensitivity I∆n (mA)<br />

Time-delay<br />

type<br />

Max. operating time at 5I∆n (s)<br />

Max. inertial non-operating time at 2I∆n (s)<br />

Earth-leakage indication system<br />

Rated short-circuit<br />

440V<br />

breaking capacity (kA)<br />

IEC60947-2<br />

AC 400V<br />

(Icu/Ics)<br />

230V<br />

Standard Attached Parts<br />

(Front connection)<br />

NV800-SEW<br />

NV800-HEW<br />

3<br />

100-440 Multi-voltage type<br />

400-800 adjustable<br />

(100 · 200 · 500 Selectable)<br />

(0.04)<br />

100 · 200 · 500 Selectable<br />

0.45 · 1.0 · 2.0 Selectable<br />

0.1 · 0.5 · 1.0<br />

Button<br />

42/42<br />

65/65<br />

50/50<br />

70/70<br />

85/85<br />

100/100<br />

Mounting screw: M6×35 (4pcs)<br />

Insulation barrier: (2pcs)<br />

■Operating Characteristics<br />

10h<br />

■Earth-Leakage Tripping Characteristics<br />

Operating time<br />

5h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s Pre-alarm pickup current Ip<br />

Ir × (0.7 – 0.75 – 0.8 – 0.85<br />

2s – 0.9 – 0.95 – 1.0) ±10%<br />

1s<br />

0.5s<br />

0.2s<br />

Pre-alarm operating time Tp<br />

TL<br />

Tp= ±20%<br />

2<br />

(at 200%)<br />

LTD operating time<br />

at-125%<br />

1000s(TL=150s set)<br />

670s(TL=100s set)<br />

400s(TL= 60s set)<br />

80s(TL= 12s set)<br />

Types<br />

NV800-SEW NV800-HEW<br />

Current setting<br />

Ir:400~800A<br />

(Adjustable)<br />

Rated Current<br />

In:800A<br />

LTD operating time TL<br />

12 – 60 – 100 – 150s ±20%<br />

(at 200%)<br />

STD pickup current Isd<br />

Ir × (2 – 2.5 – 3 – 3.5 – 4<br />

– 5 – 6 – 7 – 8 – 10) ±15%<br />

STD operating time Ts<br />

0.3 ± 0.06s<br />

0.2 ± 0.04s<br />

Operating time<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.04s<br />

0.02s<br />

0.01s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

Highspeed<br />

type<br />

25 50 100 500 1000<br />

Ground-fault current<br />

(×100% of rated current sensitivity)<br />

Rated nonoperating current<br />

Time-delay type<br />

0.45s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Rated nonoperating current<br />

Time-delay type<br />

1s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

25 50 100 500 1000 25 50 100 500 1000 25 50 100 500 1000<br />

Ground-fault current Ground-fault current Ground-fault current<br />

(×100% of rated current sensitivity) (×100% of rated current sensitivity) (×100% of rated current sensitivity)<br />

Rated nonoperating current<br />

Time-delay type<br />

2s. (MAX)<br />

Rated current sensitivity<br />

Inertial<br />

nonoperating time<br />

Current (% to Ir)<br />

Instantaneous Tripping Current (% to In)<br />

Max.total<br />

breaking time<br />

60 70 100 125 200 300 400 500 600 700 1000 1500 2000 3000 4000<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Operating handle<br />

Right-side<br />

mounting<br />

INST Pickup current Ii<br />

In x(4~10) ±15%<br />

(Magnification to In)<br />

AL AX SHT or UVT MG EAL TBM<br />

PAL<br />

TI<br />

0.1 ± 0.03s<br />

0.06 ± 0.02s<br />

Lead wire<br />

direction<br />

■Current reducing curve<br />

Working current correcting ratio (%)<br />

130<br />

120<br />

110 Reference ambient temperature<br />

100<br />

90<br />

80<br />

70<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

Remark: (1) Instead of EAL and TBM, pre-alarm module (PAL) or trip indicator (TI) can be attached.<br />

(2) refer to page 46 and 47.<br />

■External Accessories<br />

(An order for<br />

Accessories<br />

Operating handle<br />

should be placed at the same time as an order of circuit breaker main body.)<br />

F<br />

S<br />

V<br />

F8SWNV<br />

S4SW<br />

V8SWF, V8SW<br />

Mechanical interlock (MI) MI-8SW3<br />

Auxiliary handle<br />

Type name<br />

(HT) HT-4SW<br />

Reference<br />

page<br />

55<br />

57<br />

54<br />

69<br />

70<br />

Large<br />

Skeleton<br />

Rear<br />

(TC-L) TCL-8SW3<br />

(TTC) TTC-8SW3<br />

(BTC) BTC-8SW3<br />

Handle<br />

lock device<br />

HL<br />

HL-S<br />

HL-4SW<br />

HLS-8SW<br />

Electrical operation device<br />

Terminal cover<br />

Accessories<br />

Type name<br />

Reference<br />

page<br />

60<br />

70<br />

61<br />

■Internal Wiring Diagram<br />

Magnetic<br />

device<br />

Line side<br />

Magnetic<br />

device<br />

Characteristic<br />

setting part<br />

CT<br />

CT<br />

CT<br />

Leakage indication button<br />

Test button<br />

ZCT<br />

Sensitivity<br />

selector<br />

Remark: In case of the CE marking, Internal wiring diagrams differ.<br />

Load side<br />

129


Front connection<br />

110<br />

87 275<br />

87<br />

Mounting hole<br />

15 32 8<br />

32<br />

32<br />

Trip button<br />

51<br />

14<br />

40<br />

140<br />

210<br />

Insulating barrier (removable)<br />

Sensitivity current selector<br />

Operating time selector<br />

(Time-delay type)<br />

Leakage indication button<br />

Test button<br />

Conductor thickness<br />

t=12 max.<br />

ø14<br />

102<br />

5<br />

94.5<br />

97<br />

103<br />

107<br />

155<br />

46<br />

8<br />

15<br />

8<br />

46<br />

ø8<br />

ø8.5<br />

40<br />

12<br />

22<br />

26<br />

Terminal dimension for directly<br />

connecting conductor<br />

(Conductor thickness t=10 max.)<br />

Conductor drilling for direct connection<br />

70<br />

Drilling plan<br />

Breaker<br />

243<br />

M6 tap or ø7<br />

R6<br />

172<br />

Front-panel cutout<br />

92<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

Breaker<br />

Rear connection<br />

Boring dimensions for rear connection<br />

type barriers (3-pole)<br />

Connection<br />

allowance<br />

25<br />

Mounting plate<br />

Stud can be rotated 90°<br />

M6 tap or ø7<br />

Breaker<br />

Groove for reducing heat by overcurrent<br />

10 5<br />

5<br />

10<br />

6-ø48<br />

24 24<br />

243<br />

4-M6 tap or ø7<br />

13<br />

45<br />

24 24<br />

243<br />

295<br />

12.5<br />

243<br />

10<br />

8 32 15<br />

113 110<br />

ø13<br />

M12 bolt<br />

8<br />

140<br />

M6 screw for<br />

mounting breaker<br />

70<br />

140<br />

ø48<br />

11 11<br />

70<br />

140<br />

8-M4 screw<br />

Add these tapped holes in<br />

8 positions to standard boring.<br />

Drilling plan<br />

Note: The bore dimensional drawing shows<br />

the breaker viewed from the rear.<br />

6<br />

Plug-in<br />

Mounting plate<br />

Plug-in terminal block<br />

Stud can be rotated 90°<br />

Breaker<br />

23<br />

126<br />

20<br />

10<br />

243<br />

301<br />

Connection allowance<br />

25<br />

M8 terminal block mounting screw<br />

40<br />

140<br />

13<br />

32 8<br />

112<br />

15<br />

ø13<br />

M12 bolt<br />

70<br />

208<br />

155<br />

ø10<br />

56 187 56<br />

Drilling plan<br />

130


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF50-SWU<br />

Type name<br />

NF50-SWU<br />

Rated current In (Amp.)<br />

(3) 5 10 15 20<br />

30 40 50<br />

Number of poles 2<br />

3<br />

Rated short-circuit<br />

braking capacity (kA)<br />

UL489<br />

IEC 60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Standard attached parts<br />

Rated voltage (AC V)<br />

AC<br />

240V<br />

Rated insulation voltage Ui (V)<br />

AC<br />

500V<br />

440V<br />

400V<br />

230V<br />

240<br />

14<br />

600<br />

7.5/4<br />

7.5/4<br />

7.5/4<br />

15/8<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (2P: 2pcs, 3P: 4pcs)<br />

Type NF50-SWU<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Type<br />

NF50-SWU<br />

Operating time<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

2s<br />

1s<br />

Min.<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of Rated current<br />

■Internal Accessories<br />

■Temperature Characteristics<br />

Left-side<br />

mounting<br />

2-pole<br />

3-pole<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Operating time change rate (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

80<br />

70<br />

–10 0 10 20 30 40 50 60<br />

Rated ambient<br />

Ambient temperature (°C)<br />

■External Accessories<br />

Accessories Type name<br />

Accessories<br />

Type name<br />

F05SWU2P<br />

F<br />

F05SWU Mechanical interlock Ml Ml-05SWU3<br />

Operating handle<br />

S S05SWU<br />

V V05SWUF (*1) Terminal<br />

Large TC-L TCL-05SWU2<br />

cover<br />

TCL-05SWU3<br />

Handle lock device HL HLF-05SWU<br />

Note: (*1) Adjustable types can be produced upon request.<br />

131


R1<br />

Front connection<br />

CL<br />

Mounting hole<br />

LC<br />

Insulation barrier<br />

(removable)<br />

M5×0.8 screw<br />

(M6 for 63A)<br />

24<br />

φ5.5<br />

6<br />

50<br />

12.5 max.<br />

(Conductor thickness<br />

t=5 max.)<br />

CL<br />

111<br />

150<br />

84<br />

50<br />

φ8.5<br />

Conductor drilling<br />

for direct connection<br />

Trip button<br />

φ4.5<br />

50<br />

61<br />

45<br />

25 22<br />

68<br />

50<br />

50<br />

4<br />

72<br />

75<br />

90<br />

2-pole<br />

3-pole<br />

M4×0.7 taps or 5mm dia.hole<br />

LC<br />

LC<br />

Breaker<br />

LC<br />

LC<br />

Breaker<br />

LC<br />

111<br />

LC<br />

52<br />

25<br />

50<br />

70<br />

2-pole<br />

Drilling plan<br />

3-pole<br />

2-pole<br />

Front-panel cutout<br />

3-pole<br />

1.0mm clearance on each side of<br />

the handle frame.<br />

6<br />

132


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF100-CWU<br />

NF100-SWU<br />

Type name<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

NF100-CWU<br />

50 60<br />

75 100<br />

NF100-SWU<br />

15 20 30 40<br />

50 60<br />

75 100<br />

Number of poles 2 3 2 3<br />

Rated voltage (AC V)<br />

240<br />

480Y/277<br />

UL 489<br />

480Y/277V<br />

–<br />

22<br />

AC<br />

240V<br />

10<br />

35<br />

Rated insulation voltage Ui (V) 600<br />

690<br />

690V<br />

–<br />

8/4<br />

IEC 60947-2<br />

500V<br />

7.5/4<br />

18/9<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

AC<br />

440V<br />

400V<br />

10/5<br />

10/5<br />

25/13<br />

30/15<br />

230V<br />

30/15<br />

50/25<br />

DC<br />

250V<br />

7.5/4<br />

15/8<br />

Rated short-circuit breaking<br />

capacities (kA)<br />

Standard attached parts<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (2P: 2pcs, 3P: 4pcs),<br />

Insulation board: (1pc)<br />

Type NF100-SWU<br />

■Operating Characteristics<br />

4h<br />

4h<br />

2h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Types<br />

NF100-CWU 50A~100A<br />

NF100-SWU 40A~100A<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Type<br />

NF100-SWU 15A~30A<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max. (60A~100A)<br />

Max. (40A,50A)<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

1s<br />

1s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.2s<br />

0.1s<br />

0.1s<br />

0.05s<br />

0.05s<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40 50 6070<br />

×100% of Rated current<br />

×100% of rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

2-pole<br />

3-pole<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

80<br />

–10<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

Type name<br />

Accessories<br />

Type name<br />

F<br />

F1SWU2P<br />

F1SWU Mechanical interlock Ml Ml-05SWU3<br />

S S1SWU<br />

V V1SWU (*1) Terminal<br />

Large TC-L TCL-1SWU2<br />

cover<br />

TCL-1SWU3<br />

HL HLF-1SWU<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

133


Front connection<br />

(Standard)<br />

CL<br />

Insulation barrier<br />

(removable)<br />

φ8.5<br />

150 50<br />

112<br />

CL<br />

Mounting<br />

hole<br />

CL<br />

LC<br />

84<br />

M8 screw<br />

50<br />

24<br />

(Conductor thickness<br />

t=5 max)<br />

19 max.<br />

8<br />

Conductor drilling<br />

for direct connection<br />

Trip<br />

button<br />

45<br />

50<br />

30<br />

60<br />

22<br />

60<br />

90<br />

61<br />

68<br />

4 72<br />

90<br />

2-pole<br />

3-pole<br />

Front connection (Solderless terminal)<br />

(Option)<br />

Solderless terminal<br />

LC<br />

CL<br />

5.03<br />

LC<br />

LC<br />

Hexagon socket set screw<br />

wire size<br />

14~1/0AWG CU/AL<br />

2-pole<br />

3-pole<br />

6<br />

2-pole<br />

3-pole<br />

62<br />

CL<br />

LC<br />

Breaker<br />

CL<br />

LC<br />

Breaker<br />

30<br />

30<br />

CL<br />

CL<br />

110-111<br />

CL<br />

LC<br />

R 1<br />

52<br />

(Insulation plate)<br />

(Line)<br />

2-pole<br />

30<br />

3-pole<br />

M4×0.7 taps or<br />

5mm-dia. hole<br />

57<br />

1.0mm clearance on each<br />

side of the handle frame.<br />

86<br />

CAUTION:<br />

When mounted in steel or cast box<br />

cover must be insulated as shown.<br />

30mm air gap to cover or<br />

0.8mm fibre insulating plate<br />

extending 12.7mm out from<br />

each side of breaker.<br />

Drilling plan<br />

Front-panel cutout<br />

134


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF225-CWU<br />

Type name<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

NF225-CWU<br />

125 150 175<br />

200 225<br />

Number of poles 3<br />

Rated short-circuit breaking<br />

capacities (kA)<br />

UL 489<br />

IEC 60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Standard attached parts<br />

Rated voltage (AC V)<br />

AC<br />

240V<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

500V<br />

440V<br />

400V<br />

230V<br />

250V<br />

240<br />

35<br />

600<br />

10/5<br />

15/8<br />

18/9<br />

35/18<br />

10/5 (*1)<br />

Mounting screw: M4×0.7×55 (2pcs)<br />

Insulation barrier: (4pcs),<br />

Terminal cover: (1 set), (*2)<br />

Type NF225-CWU<br />

Notes: (*1) Use either two poles. When wired as shown at the bottom of page 26, the models can<br />

be used for up to 400 V DC.<br />

(*2) The standard configuration contains a protection cover and adopts the IP20 (finger<br />

protection) structure.<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

Type<br />

NF225-CWU<br />

Operating time<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Max.<br />

2s<br />

Min.<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Max. total<br />

breaking<br />

time<br />

0.05s<br />

0.02s<br />

0.01s<br />

Time-delay trip<br />

Instantaneous trip<br />

1 1.35<br />

2 3<br />

4<br />

5 6 7 10 15 20 30<br />

40<br />

×100% of Rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Curreny rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

80<br />

–10<br />

0<br />

10<br />

20<br />

30<br />

40<br />

50<br />

60<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

F<br />

F2SWU<br />

S S2SWU<br />

V V2SWU (*1)<br />

HL<br />

Type name<br />

HLF-2SWU<br />

Terminal<br />

cover<br />

Accessories<br />

Mechanical interlock<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

Ml<br />

Type name<br />

MI-05SWU3<br />

Large TC-L TCL-2SWU3<br />

135


Front connection<br />

Mounting hole<br />

LC<br />

Trip button<br />

LC<br />

Insulating barrier<br />

144<br />

100 165<br />

100<br />

102<br />

M8 bolt<br />

(Hex-soket)<br />

50<br />

φ8.5<br />

24<br />

φ4.5<br />

22<br />

70<br />

105<br />

45<br />

61<br />

68<br />

4 72<br />

92<br />

CL<br />

Breaker<br />

LC<br />

Breaker<br />

CL<br />

126<br />

CL<br />

R1<br />

52<br />

φ8.5<br />

10<br />

22 max.<br />

Bus t max.=7<br />

35<br />

Drilling plan<br />

M4×0.7 screw<br />

or φ5<br />

100<br />

Front cover cutout<br />

1mm clearance on<br />

each side of handle<br />

Bus drilling for<br />

direct connection<br />

6<br />

136


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF-SFW<br />

NF-SJW<br />

NF-HJW<br />

Type name NF-SFW NF-SJW NF-HJW<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C (IEC30°C)<br />

15 20 30 40<br />

50 60 70 80<br />

90 100 110<br />

125 150<br />

(125) (150) 175<br />

200 225 250<br />

125 150 175<br />

200 225 250<br />

Number of poles 3 3 3<br />

Rated voltage (AC V)<br />

600Y/347 600Y/347 600Y/347<br />

UL 489<br />

600Y/347V<br />

14<br />

14<br />

18<br />

AC<br />

480V<br />

35<br />

35<br />

50<br />

240V<br />

65<br />

65<br />

100<br />

Rated insulation voltage Ui (V)<br />

690<br />

690<br />

690<br />

690V<br />

8/8<br />

8/8<br />

15/15<br />

IEC 60947-2<br />

500V<br />

30/30<br />

30/30<br />

36/36<br />

JIS C 8201-2<br />

440V<br />

36/36<br />

36/36<br />

50/50<br />

AC<br />

(Icu/Ics)<br />

400V<br />

36/36<br />

36/36<br />

50/50<br />

230V<br />

85/85<br />

85/85<br />

100/100<br />

DC<br />

250V (*1) 20/20<br />

20/20<br />

20/20<br />

Rated short-circuit breaking<br />

capacities (kA)<br />

Mounting screw: M4×0.7×73 (4pcs)<br />

Standard attached parts<br />

Insulation barrier: (4pcs),<br />

Insulation board: (1pc)<br />

Note: (*1) Use either two poles. When wired as shown at the bottom of page 26, the models can be used for up to 500 V DC.<br />

Type NF-SFW<br />

■Operating Characteristics<br />

4h<br />

4h<br />

4h<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Type<br />

NF-SFW<br />

15A~40A<br />

Max.(40A)<br />

Max.(15A~30A)<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.(60A~150A)<br />

Max.(50A)<br />

Type<br />

NF-SFW<br />

50A~150A<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

Max.<br />

Type<br />

NF-SJW/HJW<br />

125A~250A<br />

Instantaneous trip<br />

adjustment range<br />

Position AC<br />

of notch x In (%)<br />

4 400±80<br />

6 600<br />

8 800<br />

10 1000±200<br />

2s<br />

2s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Max. total<br />

breaking<br />

time<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

(60A~150A)<br />

(50A)<br />

Max. total<br />

breaking<br />

time<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Adjustable range<br />

Max. total<br />

breaking<br />

time<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

1 1.35 2 3 4 5 6 7 10 15 20 30 40<br />

0.02s<br />

0.01s<br />

1<br />

1.35<br />

Time-delay trip<br />

Instantaneous trip<br />

2 3 4 5 6 7 10 15 20 30<br />

40<br />

0.02s<br />

Time-delay trip<br />

0.01s<br />

1 1.35 2 3<br />

4<br />

Instantaneous trip<br />

5 6 7 10 15 20 30<br />

40<br />

×100% of Rated current ×100% of Rated current ×100% of Rated current<br />

■Internal Accessories<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

AL AX<br />

mounting<br />

SHT or UVT<br />

■External Accessories<br />

Lead wire<br />

direction<br />

■Ambient Compensating Curve<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

–10<br />

0<br />

Rated ambient<br />

10 20 30 40<br />

Ambient temperature (°C)<br />

(rated ambient 40°C)<br />

Remark: The reference ambient temperature for IEC<br />

models is 30°C.<br />

50<br />

60<br />

Accessories<br />

Operating<br />

handle<br />

Handle<br />

lock device<br />

F<br />

F2GSWU<br />

S S2GSWU<br />

V V2GSWU (*1)<br />

HL<br />

Type name<br />

HLF-2GSWU<br />

Terminal<br />

cover<br />

Accessories<br />

Mechanical interlock<br />

Ml<br />

Type name<br />

Ml-05SWU3<br />

Large TC-L TCL-2GSWU3<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

137


Front connection<br />

(Standard)<br />

Mounting hole<br />

LC<br />

Insulating barrier<br />

(removable)<br />

50<br />

Hex.socket head<br />

M8 bolt<br />

24<br />

CAUTION:<br />

Insulating barriers must be used<br />

with uninsulated bus bars or<br />

climp on terminals.<br />

LC<br />

144<br />

185<br />

112<br />

50<br />

φ8.5<br />

φ4.5<br />

10<br />

24 max.<br />

Trip button<br />

50<br />

ø8.5<br />

22<br />

(Conductor thickness t=7max.)<br />

63<br />

22<br />

79<br />

83<br />

Bus bar drilling for<br />

direct connection<br />

35<br />

4<br />

86<br />

4-FRONT<br />

70<br />

90<br />

105<br />

110<br />

Front connection (Solderless terminal)<br />

(Option)<br />

Mounting hole<br />

LC<br />

Hexagon socket set screw<br />

6.1<br />

LC<br />

144<br />

185<br />

112<br />

50<br />

Wire size<br />

14AWG-250MCM CU/AL<br />

Trip button<br />

ø8.5<br />

83<br />

63<br />

φ4.5<br />

22<br />

35<br />

4<br />

86<br />

90<br />

70<br />

105<br />

110<br />

3-FRONT<br />

6<br />

LC<br />

LC<br />

Breaker<br />

126<br />

LC<br />

LC<br />

Breaker<br />

R1<br />

52<br />

CAUTION:<br />

When mounted in steel or cast box cover<br />

must be insulated as shown.<br />

26mm air gap to cover or extending 12.7mm<br />

out fromeach side of breaker.<br />

62<br />

27<br />

1.0mm clearance<br />

26<br />

on each side of<br />

35<br />

Drilling plan<br />

M4×0.7 taps or<br />

5mm-dia. hole<br />

the handle frame.<br />

100<br />

Front-panel cutout<br />

5-RIGHT<br />

Insulation plate<br />

(Line)<br />

Outline and dimensions (mm (inch))<br />

Type NF-SFW,NF-SJW,NF-HJW<br />

138


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF-SKW<br />

Type name<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C<br />

NF-SKW<br />

250 300<br />

350 400<br />

Number of poles 3<br />

Rated short-circuit breaking<br />

capacities (kA)<br />

UL 489<br />

IEC 60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Rated voltage (AC V)<br />

AC<br />

600Y/347V<br />

480V<br />

240V<br />

Rated insulation voltage Ui (V)<br />

AC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

600Y/347<br />

20<br />

35<br />

65<br />

690<br />

10/10 (5/5) (*1)<br />

30/30 (25/25) (*1)<br />

42/42 (36/36) (*1)<br />

45/45 (36/36) (*1)<br />

85/85 (65/65) (*1)<br />

Type NF-SKW<br />

Notes: (*1) In case of solderless ter minal, interrupting capacity reduces: (/).<br />

■Operating Characteristics<br />

4h<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Type<br />

NF-SKW<br />

2min<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

Min.<br />

Max.<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max.total<br />

interrupting time<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

100 135 200 300 400 500 700 1000 1500 2000 3000 4000<br />

600<br />

% of rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side AL<br />

mounting<br />

NF-SKW<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

(*1)<br />

(rated ambient 40°C)<br />

80<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(*1)<br />

■External Accessories<br />

(*1) (*1)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separataly for<br />

left-side mounting.<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

Type name<br />

F F4SKW<br />

S S4SKW<br />

V V4SKW (*1)<br />

HL HL-4SP<br />

Ter minal<br />

cover<br />

Accessories<br />

Type name<br />

Large TC-L TCL-4SKW<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

139


Front connection (Solderless terminal)<br />

Hexagon socket set screw<br />

Solderless terminal<br />

250~400A<br />

Tightening torque<br />

275lb-in. (31.1N·m)<br />

Mounting<br />

hole<br />

8<br />

Trip<br />

button<br />

225<br />

257<br />

102<br />

φ12.5<br />

φ7<br />

47<br />

UL<br />

Ampere ratings<br />

250A, 300A<br />

250A<br />

350A, 400A<br />

Wire size<br />

250-350MCM CU<br />

350MCM AL<br />

3/0AWG CU ONLY<br />

87<br />

140<br />

97<br />

103<br />

IEC<br />

Ampere ratings<br />

Wire size (IEC 60228)<br />

Class 2 Class 5<br />

(max.141)<br />

5<br />

107<br />

155<br />

250A~350A 70~185mm 2 95~185mm 2<br />

400A 150~240mm 2 150~185mm 2<br />

Note: Do not remove solderless terminal in any case.<br />

Standard attached parts<br />

Mounting screw:M6×60 (4pcs), Insulating plate: (1pc)<br />

Front connection (Busbar terminal)<br />

Insulating barrier<br />

(removable)<br />

46<br />

110<br />

26<br />

13<br />

Bus t max.<br />

t10<br />

10<br />

Mounting<br />

hole<br />

257 44<br />

102<br />

Trip<br />

button<br />

φ12.5<br />

φ7<br />

47<br />

φ13<br />

6<br />

Breaker<br />

Breaker<br />

CAUTION<br />

97<br />

30<br />

58<br />

10<br />

46<br />

112<br />

140<br />

(max.141)<br />

5<br />

97<br />

103<br />

107<br />

Note: Do not remove busbar terminal in any case.<br />

Standard attached parts<br />

Mounting screw:M6×60 (4pcs), Insulating barrier: (4pcs), Insulating plate: (1pc)<br />

155<br />

R6<br />

When mounted in steel or cast box cover<br />

must be insulated as shown.<br />

58mm air gap to cover or 0.8mm fibre<br />

insulating plate extending 12.7mm out<br />

from each side of breaker.<br />

194<br />

92<br />

44 7dia. holes<br />

118<br />

or M6 taps<br />

1mm clearance on<br />

each side of handle.<br />

Insulating plate<br />

Drilling plan<br />

Front-panel cutout<br />

(Line)<br />

140


6. Characteristics and Dimensions<br />

UL489 Listed Molded-Case Circuit Breakers<br />

NF-SLW<br />

Type name<br />

Rated current In (Amp.)<br />

at ambient temperature 40°C<br />

NF-SLW<br />

500 600<br />

Number of poles 3<br />

Rated short-circuit breaking<br />

capacities (kA)<br />

UL 489<br />

IEC 60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Rated voltage (AC V)<br />

AC<br />

600Y/347V<br />

480V<br />

240V<br />

Rated insulation voltage Ui (V)<br />

AC<br />

690V<br />

500V<br />

440V<br />

400V<br />

230V<br />

600Y/347<br />

20<br />

35<br />

85<br />

690<br />

10/10<br />

30/30<br />

42/42<br />

45/45<br />

85/85<br />

Type NF-SLW<br />

■Operating Characteristics<br />

4h<br />

2h<br />

Operating time<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

Min.<br />

Max.<br />

Type<br />

NF-SLW<br />

Inst. trip adjustment<br />

range (4 steps)<br />

Control<br />

setting<br />

Lo<br />

2<br />

3<br />

Hi<br />

Inst. trip<br />

current (%)<br />

400±100<br />

600<br />

800<br />

1000±200<br />

Adjustable range<br />

of inst. pick up<br />

current<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Max. total<br />

interrupting time<br />

0.02s<br />

Time-delay trip<br />

Instantaneous trip<br />

0.01s<br />

100 135 200 300 400 500 700 1000 1500 2000 3000 4000<br />

600<br />

% of rated current<br />

■Internal Accessories<br />

■Ambient Compensating Curve<br />

Left-side<br />

mounting<br />

Operating handle<br />

Right-side<br />

mounting<br />

AL<br />

AX<br />

SHT or UVT<br />

Lead wire<br />

direction<br />

Current rating (%)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

Rated ambient<br />

(*1) (*1)<br />

(rated ambient 40°C)<br />

80<br />

0 10 20 30 40 50 60<br />

Ambient temperature (°C)<br />

(*1) (*1)<br />

Note: (*1) Right-side mounting is standard of SHT and UVT. Specify separataly for<br />

left-side mounting.<br />

■External Accessories<br />

Accessories<br />

Operating handle<br />

Handle lock device<br />

F F6SLW<br />

S S4SKW<br />

V V6SLW (*1)<br />

HL<br />

Type name<br />

HL-4SP<br />

Ter minal<br />

cover<br />

Accessories<br />

Note: (*1) Attach the letter “F” to the end of designation for a fixed type.<br />

Type name<br />

Large TC-L TCL-6SLW<br />

141


Front connection (Solderless terminal)<br />

Solderless termianl<br />

Hexagon socket set screw<br />

Mounting<br />

hole<br />

Tightening torque<br />

275lb-in. (31.1N·m)<br />

243<br />

275<br />

102<br />

8<br />

Trip<br />

button<br />

φ14<br />

φ8<br />

15<br />

UL<br />

Ampere ratings<br />

Wire size<br />

500A, 600A<br />

250-500MCM CU ONLY<br />

140<br />

210<br />

Note: Do not remove solderless terminal in any case.<br />

Standard attached parts<br />

Mounting screw:M6×35 (4pcs), Insulating plate: (1pc)<br />

97<br />

103<br />

5 107<br />

155<br />

IEC<br />

Wire size (IEC 60228)<br />

Ampere ratings<br />

Class 2 Class 5<br />

500A, 600A 95~185mm 2 120~185mm 2<br />

Front connection (Busbar terminal)<br />

Insulating barrier<br />

(removable)<br />

Bus t max.<br />

t12<br />

46<br />

10<br />

275<br />

102<br />

110<br />

Mounting<br />

hole<br />

15<br />

Trip<br />

button<br />

φ14<br />

φ8<br />

14<br />

8<br />

32<br />

87<br />

6<br />

10<br />

40<br />

15<br />

46<br />

140<br />

210<br />

φ14<br />

97<br />

103<br />

5<br />

107<br />

Note: Do not remove busbar terminal in any case.<br />

Standard attached parts<br />

Mounting screw:M6×35 (4pcs), Insulating barrier: (2pcs), Insulating plate: (1pc)<br />

155<br />

Breaker<br />

R6<br />

Breaker<br />

CAUTION<br />

When mounted in steel or cast box cover<br />

must be insulated as shown.<br />

58mm air gap to cover or 0.8mm fibre<br />

insulating plate extending 12.7mm out<br />

from each side of breaker.<br />

243<br />

92<br />

97<br />

30<br />

58<br />

70<br />

7dia. holes<br />

or M6 taps<br />

172<br />

1mm clearance on<br />

each side of handle.<br />

Insulating plate<br />

Drilling plan<br />

Front-panel cutout<br />

(Line)<br />

142


6. Characteristics and Dimensions<br />

Miniature Circuit Breakers<br />

BH<br />

BH-P<br />

Type<br />

Number of poles<br />

Rated current (A)<br />

at ambient temperature 40°C<br />

1<br />

70<br />

BH<br />

2<br />

70, 100<br />

3<br />

70, 100<br />

1<br />

70<br />

BH-P<br />

2<br />

70, 100<br />

3<br />

70, 100<br />

Rated voltage (V)<br />

AC<br />

DC<br />

Breaking<br />

capacity<br />

AC230/400V<br />

IEC60898<br />

AC400V<br />

(kA) sym. — DC125V<br />

3<br />

—<br />

230/400<br />

125<br />

1<br />

—<br />

3<br />

3<br />

—<br />

230/400<br />

125<br />

1<br />

—<br />

3<br />

Type BH<br />

Type BH-P<br />

■Operating Characteristics<br />

■Ambient Compensating Curve<br />

4h<br />

Operating Characteristics<br />

2h<br />

Type:BH, BH-P<br />

140<br />

1h<br />

Rated Current:70, 100A<br />

Amb. temp.:40°C<br />

135<br />

30min<br />

130<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

Current rating (%)<br />

125<br />

120<br />

115<br />

110<br />

105<br />

100<br />

70, 100A<br />

Rated ambient<br />

30s<br />

95<br />

Operating time<br />

20s<br />

10s<br />

5s<br />

Max.<br />

90<br />

85<br />

0 10 30 40<br />

20 50 60<br />

Ambient temperature (°C)<br />

2s<br />

Min.<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.13 1.45 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of rated current<br />

■Outside Dimension Diagram<br />

•BH<br />

Mtg bracket<br />

M5 × 0.8 screw<br />

(line side & load side)<br />

73<br />

95<br />

57<br />

32<br />

95<br />

100<br />

113<br />

•BH-P<br />

57.5 7.5<br />

M5 x 0.8<br />

screw<br />

Plug-in terminal<br />

(line side)<br />

71.5<br />

74<br />

Breaker<br />

center<br />

25<br />

22<br />

25<br />

50<br />

47<br />

50<br />

75<br />

47<br />

Mtg hole ø4.5<br />

57.5<br />

63.5<br />

77.5<br />

25 25 25<br />

25 50<br />

75<br />

20.5<br />

45.5<br />

70.5<br />

60.5<br />

65.5<br />

79<br />

Mtg slot<br />

Bus t max. =4<br />

ø5.5<br />

5.5<br />

6<br />

12<br />

1-pole<br />

2-pole<br />

3-pole 13.5<br />

Bus drilling<br />

4.5<br />

Note: Two mounting brackets are used for single-pole breakers.<br />

and four for two-pole and three-pole breakers.<br />

1-pole<br />

2-pole<br />

3-pole<br />

14<br />

143


BH-S<br />

Type<br />

Number of poles<br />

Rated current (A)<br />

at ambient temperature 40°C<br />

Rated voltage (V)<br />

AC<br />

DC<br />

Breaking<br />

capacity<br />

AC230/400V<br />

IEC60898<br />

AC400V<br />

(kA) sym. — DC125V<br />

1<br />

5, 10, 15,<br />

20, (25), 30,<br />

40, 50, 60<br />

230/400<br />

—<br />

3<br />

—<br />

—<br />

BH-S M3<br />

2 3<br />

10, 15, 20,<br />

(25), 30, 40,<br />

50, 60<br />

400<br />

125<br />

—<br />

3<br />

15, 20, (25),<br />

30,40, 50,<br />

60<br />

400<br />

—<br />

1 —<br />

1<br />

5, 10, 15,<br />

20, (25), 30,<br />

40, 50, 60<br />

230/400<br />

—<br />

6<br />

—<br />

—<br />

BH-S M6<br />

2 3<br />

10, 15, 20,<br />

(25), 30, 40,<br />

50, 60<br />

400<br />

125<br />

—<br />

6<br />

15, 20, (25),<br />

30,40, 50,<br />

60<br />

400<br />

—<br />

1 —<br />

Type BH-S<br />

■Operating Characteristics<br />

■Ambient Compensating Curve<br />

4h<br />

140<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

2min<br />

Operating Characteristics<br />

Type:BH-S<br />

Rated Current:5~60A<br />

Amb. temp.:40°C<br />

Current rating (%)<br />

135<br />

130<br />

125<br />

120<br />

115<br />

110<br />

105<br />

100<br />

95<br />

10A<br />

15-25A<br />

30A<br />

5A<br />

40-60A<br />

Rated ambient<br />

1min<br />

Max.<br />

90<br />

85<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

80<br />

0 10 30 40<br />

20 50 60<br />

Ambient temperature (°C)<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Type B<br />

Type C<br />

Type D<br />

6<br />

0.02s<br />

0.01s<br />

1 1.13 1.45 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of rated current<br />

■Outside Dimension Diagram<br />

•BH-S<br />

Mtg bracket<br />

M5 × 0.8 screw<br />

(line side & load side)<br />

32<br />

73<br />

95<br />

57<br />

95<br />

100<br />

113<br />

25<br />

25<br />

50<br />

50<br />

75<br />

Mtg hole<br />

ø4.5<br />

57.5<br />

63.5<br />

76<br />

Bus t max. =4<br />

ø5.5<br />

5.5<br />

6<br />

1-pole<br />

2-pole<br />

3-pole 13.5<br />

12<br />

Bus drilling<br />

Note: Two mounting brackets are used for single-pole breakers.<br />

and four for two-pole and three-pole breakers.<br />

144


6. Characteristics and Dimensions<br />

Miniature Circuit Breakers<br />

BH-PS<br />

Type<br />

Number of poles<br />

Rated current (A)<br />

at ambient temperature 40°C<br />

Rated voltage (V)<br />

AC<br />

DC<br />

Breaking<br />

capacity<br />

AC230/400V<br />

IEC60898<br />

AC400V<br />

(kA) sym. — DC125V<br />

1<br />

10, 15, 20,<br />

30, 40, 50,<br />

60<br />

230/400<br />

—<br />

3<br />

—<br />

—<br />

BH-PS M3<br />

2 3<br />

10, 15, 20,<br />

30, 40, 50,<br />

60<br />

400<br />

125<br />

—<br />

3<br />

15, 20, 30,<br />

40, 50, 60<br />

400<br />

—<br />

1 —<br />

1<br />

6, 10, 16,<br />

20, (25), 32,<br />

40, 50, 60<br />

230/400<br />

9<br />

—<br />

BH-PS M9<br />

2 3<br />

10, 16, 20,<br />

(25), 30, 40,<br />

50, 60<br />

400<br />

—<br />

—<br />

—<br />

9<br />

10, 16, 20,<br />

(25), 32, 40,<br />

50, 60<br />

400<br />

Type BH-PS<br />

■Operating Characteristics<br />

■Ambient Compensating Curve<br />

4h<br />

140<br />

2h<br />

1h<br />

30min<br />

20min<br />

14min<br />

10min<br />

6min<br />

4min<br />

Operating Characteristics<br />

Type:BH-PS<br />

Rated Current:5~60A<br />

Amb. temp.:40°C<br />

Current rating (%)<br />

135<br />

130<br />

125<br />

120<br />

115<br />

110<br />

105<br />

100<br />

15-20A, 40A<br />

10A<br />

6A, 30A, 32A<br />

50A, 60A<br />

Rated ambient<br />

2min<br />

95<br />

1min<br />

Max.<br />

90<br />

85<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

Min.<br />

80<br />

0 10 30 40<br />

20 50 60<br />

Ambient temperature (°C)<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

Type B<br />

Type C<br />

Type D<br />

0.05s<br />

0.02s<br />

0.01s<br />

1 1.13 1.45 2 3 4 5 6 7 10 15 20 30 40<br />

×100% of rated current<br />

■Outside Dimension Diagram<br />

•BH-PS<br />

57.5 7.5<br />

Plug-in terminal<br />

(line side)<br />

71.5<br />

81.5<br />

25<br />

25<br />

50<br />

25 25<br />

75<br />

M5 x 0.8<br />

screw<br />

60.5<br />

65.5<br />

79<br />

Mtg slot<br />

22 47 72<br />

4.5<br />

1-pole 2-pole 3-pole<br />

14<br />

145


6. Characteristics and Dimensions<br />

DIN Series<br />

BH-D6<br />

MCB<br />

BH-D6 (IEC60898)<br />

Number of poles<br />

1<br />

2<br />

3<br />

4 (3+N) 2 (1+N)<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

6, 10, 13, 16, 20,<br />

25, 32, 40, 50, 63<br />

6, 10, 13, 16, 20,<br />

25, 32, 40, 50, 63<br />

6, 10, 13, 16, 20,<br />

25, 32, 40, 50, 63<br />

6, 10, 13, 16, 20,<br />

25, 32, 40, 50, 63<br />

6, 10, 13, 16, 20,<br />

25, 32, 40<br />

Rated voltage (VAC)<br />

230/400<br />

400<br />

400<br />

400 230<br />

Breaking capacity (kA) sym. (IEC60898)<br />

6<br />

Type BH-D6<br />

■Operating Characteristics<br />

Min<br />

s<br />

Min<br />

s<br />

200<br />

100<br />

50<br />

30<br />

20<br />

10000<br />

5000<br />

2000<br />

1000<br />

Tripping Characteristics<br />

Type:BH-D6<br />

Rated Current:6A-63A<br />

Amb. temp.:30°C<br />

200<br />

100<br />

50<br />

30<br />

20<br />

10000<br />

5000<br />

2000<br />

1000<br />

Tripping Characteristics<br />

Type:BH-D6<br />

Rated Current:6A-63A<br />

Amb. temp.:30°C<br />

10<br />

500<br />

10<br />

500<br />

5<br />

5<br />

200<br />

200<br />

2<br />

1<br />

100<br />

50<br />

30<br />

Max.<br />

2<br />

1<br />

100<br />

50<br />

30<br />

Max.<br />

Tripping time<br />

20<br />

10<br />

5<br />

2<br />

1<br />

0.5<br />

0.2<br />

0.1<br />

Min.<br />

B<br />

C<br />

Tripping time<br />

20<br />

10<br />

5<br />

2<br />

1<br />

0.5<br />

0.2<br />

0.1<br />

Min.<br />

6-10A<br />

13-63A<br />

D<br />

0.05<br />

Max total<br />

0.05<br />

0.02<br />

tripping time<br />

0.02<br />

0.01<br />

0.6<br />

0.7 1 1.13 1.45 2 3 4 5 6 7 10 15 20 30<br />

×100% of rated current<br />

0.01<br />

0.6<br />

0.7 1 1.13 1.45 2 3 4 5 6 7 10 15 20 30<br />

×100% of rated current<br />

6<br />

■Ambient Compensating Curve<br />

135<br />

130<br />

■Outside Dimension Diagram<br />

•BH-D6<br />

M5 screw<br />

Neutral Pole<br />

125<br />

N<br />

N<br />

120<br />

Current ratings (%)<br />

115<br />

110<br />

105<br />

100<br />

95<br />

Rated<br />

ambient<br />

45<br />

44.5<br />

87<br />

92<br />

90<br />

N<br />

N<br />

85<br />

-10 -5 0<br />

5 10 15 20 25 30 35 40<br />

Ambient temperature (°C)<br />

18<br />

18<br />

36<br />

18<br />

36<br />

36<br />

54<br />

18<br />

54<br />

72<br />

Insulation<br />

Barrier(Option)<br />

17 44 6<br />

70 maximum<br />

Solderless terminal<br />

1-pole 1+N-pole 2-pole 3-pole 4-pole<br />

146


6. Characteristics and Dimensions<br />

DIN Series<br />

BH-DN<br />

MCB<br />

Number of poles<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

Rated voltage (VAC)<br />

Breaking capacity (kA) sym. (IEC60898)<br />

BH-DN (IEC60898)<br />

2 (1+N)<br />

6, 10, 16, 20<br />

230<br />

4.5<br />

Type BH-DN<br />

■Operating Characteristics<br />

Min<br />

200<br />

100<br />

50<br />

30<br />

20<br />

10<br />

5<br />

2<br />

1<br />

Sec<br />

10000<br />

5000<br />

2000<br />

1000<br />

500<br />

200<br />

100<br />

50<br />

30<br />

20<br />

10<br />

5<br />

Max<br />

Tripping Characteristics<br />

Type : BH-DN<br />

Rated current : 6A~20A<br />

Amb.temp. : 30°C<br />

2<br />

Min<br />

1<br />

Tripping time<br />

0.5<br />

0.2<br />

0.1<br />

0.05<br />

0.02<br />

Max.total<br />

tripping time<br />

0.01<br />

1 1.13 1.45 2 3 4 6 10 15<br />

0.6 0.7 20<br />

5 7 30<br />

× Rated current<br />

■Outside Dimension Diagram<br />

•BH-DN<br />

M4 SCREW<br />

18<br />

8.4<br />

N<br />

N<br />

45<br />

70 maximum<br />

6 44 17<br />

Solderless Terminal<br />

45<br />

88<br />

147


BV-D<br />

RCCB<br />

Number of poles<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

Rated voltage (VAC)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time (sec) at 5I∆<br />

Pulsating current sensitivity<br />

Rated conditional short-cirrent (kA)<br />

BV-D (IEC61008)<br />

2 (1+N) 4 (3+N)<br />

25, 40, 63<br />

230 230/400<br />

30, 300<br />

0.04<br />

Type AC<br />

6<br />

Type BV-D<br />

■Operating Characteristics<br />

Operating time<br />

2h<br />

1h<br />

30min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.1s<br />

0.05s<br />

Rated nonoperating current sensitivity<br />

Rated current sensitivity<br />

0.02s<br />

0.01s<br />

25<br />

50 100 500<br />

Ground fault current<br />

(% of rated current sensitivity)<br />

6<br />

■Outside Dimension Diagram<br />

•BV-D<br />

Residual<br />

M5 screw Test button indicator Neutral pole<br />

N<br />

45<br />

85<br />

42.5<br />

N<br />

18<br />

36<br />

18<br />

54<br />

72<br />

17 44 6<br />

70 maximum<br />

Solderless terminal<br />

2-pole<br />

4-pole<br />

148


6. Characteristics and Dimensions<br />

DIN Series<br />

BV-DN<br />

RCBO<br />

Number of poles<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

Rated voltage (VAC)<br />

Rated current sensitivity I∆n (mA)<br />

Max. operating time (sec) at 5I∆n<br />

Pulsating current sensitivity<br />

Breaking capacity (kA) sym (IEC61009)<br />

BV-DN (IEC61009)<br />

2 (1+N)<br />

6, 10, 16, 20, 25, 32<br />

230<br />

30, 100, 300<br />

0.04<br />

Type AC<br />

4.5<br />

Type BV-DN<br />

■Operating Characteristics<br />

■Leakage Tripping characteristics<br />

Min<br />

200<br />

100<br />

50<br />

30<br />

20<br />

Sec<br />

10000<br />

5000<br />

2000<br />

1000<br />

Tripping Characteristics<br />

Type : BV-DN<br />

Rated current : 6A~32A<br />

Amb.temp. : 30°C<br />

4h<br />

2h<br />

1h<br />

30min<br />

10min<br />

10<br />

5<br />

2<br />

1<br />

500<br />

200<br />

100<br />

50<br />

30<br />

20<br />

10<br />

5<br />

Max<br />

Operating time<br />

4min<br />

2min<br />

1min<br />

30s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

Rated nonoperating current<br />

Rated current sensitivity<br />

2<br />

Min<br />

0.1s<br />

0.04s<br />

1<br />

0.02s<br />

Tripping time<br />

0.5<br />

0.2<br />

0.1<br />

0.05<br />

Max.total<br />

tripping time<br />

0.01s<br />

25 50 100<br />

500<br />

Ground-fault current<br />

(% of rated current sensitivity)<br />

0.02<br />

0.01<br />

1 1.13 1.45 2 3 4 6 10 15<br />

0.6 0.7 20<br />

5 7 30<br />

× Rated current<br />

■Outside Dimension Diagram<br />

•BV-DN<br />

M4 Screw<br />

Test button<br />

8.4<br />

36<br />

N<br />

N<br />

Residual indicator<br />

45<br />

6<br />

44<br />

70 maximum<br />

17<br />

88<br />

45<br />

Solderless<br />

terminal<br />

149


KB-D<br />

Isolating switch<br />

Number of poles<br />

Utilization category<br />

Rated current (A)<br />

at ambient temperature 30°C<br />

Rated voltage (VAC)<br />

Shot time withstand current (A)<br />

Shot-circuit making capacity (A)<br />

KB-D (IEC60947-3)<br />

1 2 3 4 (3+N)<br />

AC22A class<br />

32, 63, 80<br />

230 400<br />

20 × In, 1s<br />

20 × In<br />

Type KB-D<br />

■Outside Dimension Diagram<br />

•KB-D<br />

M5 screw<br />

Neutral Pole<br />

N<br />

45<br />

87<br />

92<br />

44.5<br />

N<br />

18 36<br />

18 36 54<br />

18<br />

54<br />

72<br />

Insulation<br />

Barrier(Option)<br />

17 44 6<br />

70 maximum<br />

Solderless terminal<br />

6<br />

1-pole 2-pole 3-pole 4-pole<br />

150


6. Characteristics and Dimensions<br />

Circuit Protectors<br />

CP30-BA<br />

Type CP30-BA<br />

Number of poles<br />

Rated impulse withstand voltage Uimp (kV)<br />

Rated current (A)<br />

Rated shortcircuit<br />

capacity (kA)<br />

AC-DC common use<br />

Operating characteristics<br />

Mode of tripping<br />

UL1077<br />

CSA C22.2 No.235<br />

IEC 60934<br />

EN 60934<br />

GB 17701<br />

JIS C 4610<br />

EN 60947-2<br />

IEC 60947-2<br />

JIS C 8201-2<br />

(Icu/Ics)<br />

Frame (A) 30<br />

Type<br />

CP30-BA<br />

Rated voltage (V)<br />

AC<br />

DC<br />

AC (V)<br />

DC (V)<br />

1 2 3<br />

2.5<br />

0.1, 0.25, 0.3, 0.5,<br />

1, 2, 3, 5, 7, 10,15, 20, 30<br />

250<br />

65 125 —<br />

2.5kA at 250V<br />

2.5kA at 65V 2.5kA at 125V —<br />

Rated insulation voltage Ui (V)<br />

AC<br />

250<br />

2.5kA at 230V<br />

DC<br />

2.5kA at 60V 2.5kA at 120V —<br />

Rated insulation voltage Ui (V)<br />

250<br />

AC<br />

2.5/2.5kA at 230V<br />

DC<br />

2.5/2.5kA at 60V 2.5/2.5kA at 120V —<br />

—<br />

Instantaneous type (I)<br />

Medium type (M),(MD)<br />

Slow type (S),(SD) Fast type (F)<br />

Instantaneous type (I): magnetic only<br />

Other type (M, MD, S, SD, F):hydraulic-magnetic<br />

■Operating Characteristics<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

Instantaneous type (I) Fast type (F) Medium type (M) Slow type (S)<br />

AC<br />

DC<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

DC<br />

AC<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

DC<br />

AC<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

DC<br />

AC<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.5s<br />

0.2s<br />

0.2s<br />

0.2s<br />

0.2s<br />

0.1s<br />

0.1s<br />

0.1s<br />

0.1s<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

0.02s<br />

0.02s<br />

0.01s<br />

0.01s<br />

0.01s<br />

100 100 300 1000<br />

200 500 2000 5000 10000<br />

135 100 300 200 500<br />

10000<br />

1000 135<br />

5000 300<br />

2000 1000<br />

200 500 2000 5000<br />

150 10000<br />

180<br />

125 400 700<br />

125 400 700 125 400 700<br />

0.02s<br />

0.01s<br />

135 200<br />

1000<br />

100 300 500 2000<br />

125 400 700<br />

5000 10000<br />

Current (% of rated current)<br />

Current (% of rated current)<br />

Current (% of rated current)<br />

Current (% of rated current)<br />

■Outside Dimension Diagram<br />

•CP30-BA<br />

19.5<br />

12<br />

1<br />

Terminal<br />

cover<br />

37<br />

29.5 1<br />

Terminal<br />

cover<br />

54.5<br />

47<br />

1<br />

Terminal<br />

cover<br />

Terminal cover<br />

33<br />

IEC 35mm<br />

rail<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

Medium type with inertial delay (MD)<br />

2h<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

Slow type with inertial delay (SD)<br />

56<br />

ON<br />

56<br />

ON<br />

56<br />

54<br />

ON<br />

90<br />

65<br />

67<br />

9.5 39<br />

63<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Operating time<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

9.5 9.5<br />

17.5<br />

AXc<br />

AXb<br />

AXa<br />

1-pole<br />

Mounting dimension<br />

9.5<br />

17.5 17.5 17.5<br />

35<br />

52.5<br />

17.5 17.5<br />

AXc<br />

2-pole<br />

AXb<br />

AXa<br />

54<br />

3-pole<br />

AXc<br />

AXb<br />

AXa<br />

14<br />

Mounting hole<br />

ø4.5<br />

Terminal cover for<br />

attached terminal<br />

block<br />

5<br />

22.5<br />

35 5.5<br />

63<br />

65 3<br />

Alarm or auxiliary switch terminal block<br />

(Ic contact)<br />

Attachable on right-side only<br />

Alarm or auxiliary switch terminal M3.5<br />

(Plus minus self-up screw)<br />

(The figure shows auxiliary switch.<br />

Example: Alarms are ALa, ALb and ALc.)<br />

Main terminal<br />

(Plus minus self-up screw)<br />

M4·····20A max.<br />

M5·····30A<br />

5<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

100 300 1000<br />

200 500 2000<br />

400 125 700<br />

Current (% of rated current)<br />

■Temperature Characteristics<br />

Operating time variation (%)<br />

300<br />

250<br />

200<br />

150<br />

100<br />

90<br />

80<br />

70<br />

60<br />

0.2s<br />

0.1s<br />

0.05s<br />

0.02s<br />

0.01s<br />

5000 10000<br />

100 200 300 500 1000 2000<br />

125 400 700<br />

Current (% of rated current)<br />

Rated<br />

ambient<br />

5000<br />

10000<br />

12 29.5 47<br />

-10<br />

0 10 20 30 40 50 60<br />

1-pole 2-pole<br />

2-M tap<br />

3-pole<br />

2-M tap<br />

2-M4 tap<br />

Tightening torque 1~1.4 (N-m)<br />

(Rated ambient 40°C)<br />

151


CP-S<br />

Type CP-S<br />

Frame (A) 30<br />

Type<br />

CP-S<br />

Number of poles<br />

1 2 3<br />

Rated impulse withstand voltage Uimp (kV)<br />

2.5<br />

Rated current (A)<br />

Rated shortcircuit<br />

capacity (kA)<br />

AC-DC common use<br />

Operating characteristics<br />

Mode of tripping<br />

UL1077<br />

IEC 60934<br />

EN 60934<br />

(Icn)<br />

JIS C 4610<br />

(Icn)<br />

AC (V)<br />

Rated voltage (V)<br />

DC (V)<br />

AC<br />

DC<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

Rated insulation voltage Ui (V)<br />

AC<br />

DC<br />

0.05, 0.1, 0.25, 0.3, 0.5, 0.75<br />

1, 2, 2.5, 3, 5, 7, 7.5, 10,15, 20, 25, 30<br />

250<br />

65<br />

1.5kA at 250V<br />

1kA at 65V<br />

—<br />

—<br />

—<br />

—<br />

250<br />

1.5kA at 230V, 2.5kA at 120V<br />

1kA at 60V<br />

1kA at 120V<br />

(1kA at 60V)<br />

1kA at 60V<br />

250<br />

1.5kA at 250V, 2.5kA at 125V<br />

1kA at 65V<br />

1kA at 125V<br />

(1kA at 65V)<br />

1kA at 65V<br />

—<br />

Instantaneous type (I)<br />

Medium type (M),(MD)<br />

Slow type (S),(SD) Fast type (F),(FD)<br />

Instantaneous type (I): magnetic only<br />

Other type (M, MD, S, SD, F, FD):hydraulic-magnetic<br />

■Operating Characteristics<br />

Instantaneous type (I) Fast type (F) Medium type (M) Slow type (S) Medium type with inertial delay (MD)<br />

2h<br />

2h<br />

2h<br />

2h<br />

2h<br />

1h<br />

1h<br />

1h<br />

1h<br />

1h<br />

40min<br />

40min<br />

40min<br />

40min<br />

40min<br />

20min<br />

20min<br />

20min<br />

20min<br />

20min<br />

10min<br />

6min<br />

4min<br />

10min<br />

6min<br />

4min<br />

10min<br />

6min<br />

4min<br />

10min<br />

6min<br />

4min<br />

10min<br />

6min<br />

4min<br />

2min<br />

2min<br />

2min<br />

2min<br />

2min<br />

1min<br />

1min<br />

1min<br />

1min<br />

1min<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Operating time<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

0.2s<br />

0.2s<br />

0.2s<br />

0.2s<br />

0.2s<br />

0.1s<br />

0.1s<br />

0.1s<br />

0.1s<br />

0.1s<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.05s<br />

0.02s<br />

0.02s<br />

0.02s<br />

0.02s<br />

0.02s<br />

0.01s<br />

80 100 200 300 500 1000 2000 5000<br />

125 400 700<br />

Current<br />

(% of instantaneous tripping current set value)<br />

0.01s<br />

100 200 300 500 1000 2000<br />

125 400 700<br />

Current<br />

(% of rated current)<br />

5000 10000<br />

0.01s<br />

100 200 300 500 1000 2000<br />

125 400 700<br />

Current<br />

(% of rated current)<br />

5000 10000<br />

0.01s<br />

100 200 300 500 1000 2000<br />

2h<br />

125 400 700<br />

Current<br />

(% of rated current)<br />

5000 10000<br />

Fast type with inertial delay (FD)<br />

0.01s<br />

100 200 300 500 1000 2000<br />

2h<br />

125 400 700<br />

Current<br />

(% of rated current)<br />

5000 10000<br />

Slow type with inertial delay (SD)<br />

6<br />

■Outside Dimension Diagram<br />

•CP-S<br />

Series <br />

Switch <br />

Main terminal<br />

Mail tab terminal nominal 250<br />

(8.35W × 0.8L)<br />

Operating time<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

Operating time<br />

1h<br />

40min<br />

20min<br />

10min<br />

6min<br />

4min<br />

2min<br />

1min<br />

30s<br />

20s<br />

10s<br />

5s<br />

2s<br />

1s<br />

0.5s<br />

LINE<br />

0.2s<br />

0.1s<br />

0.2s<br />

0.1s<br />

39<br />

7.3<br />

8.8<br />

11.5<br />

Alarm · auxiliary switch terminal<br />

Tab terminal nominal 110<br />

(2.8W × 0.5L)<br />

LORD<br />

40<br />

49.5<br />

3.3<br />

55 18<br />

0.05s<br />

0.02s<br />

0.01s<br />

100 200 300 500 1000 2000<br />

125 400 700<br />

Current<br />

(% of rated current)<br />

5000 10000<br />

0.05s<br />

0.02s<br />

0.01s<br />

100 200 300 500 1000 2000<br />

125 400 700<br />

Current<br />

(% of rated current)<br />

5000 10000<br />

M3 × 0.5 tap<br />

(Depth 5)<br />

M3 × 0.5 tap<br />

(Depth 5)<br />

M3 × 0.5 tap<br />

(Depth 5)<br />

■Temperature Characteristics<br />

300<br />

ø15<br />

19<br />

26.5<br />

42<br />

51<br />

ø15<br />

42<br />

51<br />

19 19 19<br />

38<br />

57<br />

Single pole 2-pole 3-pole<br />

26.5<br />

ø15<br />

26.5<br />

42<br />

51<br />

Operating time variation (%)<br />

250<br />

200<br />

150<br />

100<br />

90<br />

80<br />

70<br />

60<br />

-10<br />

Rated<br />

ambient<br />

0 10 20 25 30 40 50 60<br />

(Rated ambient 25°C)<br />

152


7. Ordering Information<br />

Molded-Case Circuit Breakers<br />

Earth-Leakage Circuit Breakers<br />

Type name<br />

NF250-SW<br />

C<br />

S<br />

NF<br />

H<br />

U<br />

MB<br />

Economy type<br />

Standard type<br />

High-performance type<br />

Ultra current-limiting type<br />

Motor braker<br />

Type name<br />

NV250-SW<br />

NV<br />

C<br />

S<br />

H<br />

U<br />

Economy type<br />

Standard type<br />

High-performance type<br />

Ultra current-limiting type<br />

Number of poles<br />

Number of poles<br />

2P<br />

NV<br />

1ø2W<br />

3P<br />

NF<br />

MB<br />

2P, 3P, 4P<br />

3P<br />

3P<br />

3P<br />

NV<br />

1ø2W<br />

1ø3W<br />

3ø3W<br />

Rated current<br />

200A<br />

Even for adjustable rated current<br />

models, the working current should be<br />

specified.<br />

Rated current<br />

200A<br />

4P<br />

NV<br />

3ø4W<br />

Even for adjustable rated current<br />

models, the working current should be<br />

specified.<br />

Rated voltage<br />

Secify DC voltage when for use in<br />

DC circuit<br />

Rated voltage<br />

AC<br />

AC<br />

100-440V<br />

200-440V<br />

Standard<br />

Specify the applicable marine<br />

standards<br />

∗ “CE” is standard.<br />

Rated sensitivity<br />

current<br />

100 • 200 • 500mA<br />

30mA<br />

100 • 200 • 500mA<br />

Connection<br />

method<br />

B<br />

F<br />

SL<br />

B<br />

PM<br />

Front connection<br />

Solderless (box) terminal<br />

Rear connection<br />

Pulg-in<br />

Standard<br />

Specify “CE”, if necessery<br />

Built-in<br />

Accessories<br />

PAL<br />

PAL<br />

OAL<br />

CYL<br />

Pre-alarm (contact output)<br />

Overcurrent alarm<br />

Cylinder keylock<br />

Connection<br />

method<br />

B<br />

F<br />

SL<br />

B<br />

PM<br />

Front connection<br />

Solderless (box) terminal<br />

Rear connection<br />

Pulg-in<br />

Internal<br />

accessories<br />

AL, SHT (AC110V)<br />

External<br />

accessories<br />

AL<br />

AX<br />

SHT<br />

UVT<br />

SLT<br />

INT<br />

Alarm switch<br />

Auxiliary switch<br />

Shunt trip<br />

(Specify rated coil voltage.)<br />

Under voltage trip<br />

(Specify rated coil voltage.)<br />

Lead-wire terminal block<br />

Internal terminal type<br />

Type of residual<br />

carrent protection<br />

Built-in<br />

Accessories<br />

MG<br />

Blank<br />

Specify<br />

MG<br />

EAL<br />

TBM<br />

PAL<br />

High-speed type<br />

Time-delay type<br />

Insulation switch<br />

Earth-leakage circuit alarm switch<br />

Test button module<br />

Pre-alarm module<br />

Quantity<br />

10<br />

MD<br />

F • S • V<br />

S • I • W<br />

MI<br />

TC<br />

LC • HL<br />

HL-S<br />

CH<br />

Electrical operation device<br />

Operating handle<br />

Enclosure box<br />

Mechanical interlock<br />

Terminal cover<br />

(TC-L, TC-S, TTC, BTC)<br />

Handle lock device<br />

Card holder<br />

Internal<br />

accessories<br />

AX, SLT, TBM<br />

External<br />

accessories<br />

AL<br />

AX<br />

UVT<br />

SLT<br />

MD<br />

F • S • V<br />

S • I • W<br />

MI<br />

Alarm switch<br />

Auxiliary switch<br />

Under voltage trip<br />

(Specity rated coil voltage)<br />

Lead-wire terminal block<br />

Electrical operation device<br />

Operating handle<br />

Enclosure box<br />

Mechanical interlock<br />

Quantity<br />

TC<br />

Terminal cover<br />

(TC-L, TC-S, TTC, BTC)<br />

10<br />

LC • HL<br />

HL-S<br />

Handle lock device<br />

CH<br />

Card holder<br />

153


8. Melshort 2<br />

A more rational and easier breakers selections<br />

This software program ensures the easy selection of low-voltage<br />

circuit breakers according to the required rated breaking capacity<br />

and the related equipments<br />

Calculation and selection software<br />

for low-voltage circuit breakers<br />

Preparation of single-line diagram<br />

Coodination between high-voltage protection equipments<br />

Short-circuit current calculation<br />

Examination of cascade interruption combination<br />

Examination of selective interraption<br />

●Contents of a software<br />

The program's menu allows not only short-circuit current<br />

calculations but also the examination of various<br />

protection coordination.<br />

●Preparation of single-line connection diagrams.<br />

●Short-circuit calculations.<br />

●Automatic selection of breaker type.<br />

●Selection of breaker type for cascade interruption combination.<br />

●Selection of breaker type for selective interruption combination.<br />

●Examination of coordination between high-voltage protection<br />

equipments.<br />

●Protection coordination with motor start current.<br />

■Selectable products menu<br />

Advantages<br />

●Improvement of selection efficiency<br />

Because the coordination between various protection<br />

systems can be examined and breakers can be selected<br />

interactively using the personal computer screen, simple,<br />

accurate and speedy operation is ensured.<br />

●Maintenance of a software<br />

The user can download the latest software updates by<br />

accessing Mitsubishi's LVS home page on the Internet.<br />

http://www.fukuyama.melco.co.jp/lvs<br />

■Personal computer specifications<br />

7<br />

8<br />

Low-voltage circuit breaker:<br />

MCCBs, ELCBs, ACBs, MCBs, Contactors,<br />

Thermal relays, High-voltage OCRs<br />

Operating system: Windows 95/98/NT4.0/2000/XP<br />

CPU: 166 MHz or faster<br />

RAM memory size: min 32 MB<br />

Free hard disk capacity: min 50 MB<br />

Display resolution: min 640 × 480 dots<br />

CD-ROM Drive:Double speed or higher<br />

154


9. LOW-VOLTAGE SWITCHGEARS TECHNICAL<br />

http://global.MitsubishiElectric.com/lvs<br />

Advantages<br />

■Substantial menu<br />

Wide ranging technical information is classified into 6 groups.<br />

■Expert oriented information<br />

In addition to catalogs, including previous catalog editions and<br />

technical data and other information, users get answers to their<br />

technical questions.<br />

■Enhanced information collection efficiency<br />

By connecting your personal computer to the Internet, you can access<br />

the latest information simply and quickly without a need to increase<br />

storage space.<br />

Model menu<br />

■Molded-Case<br />

Circuit Breakers<br />

(MCCB)<br />

■Earth-Leakage<br />

Circuit Breakers<br />

(ELCB)<br />

■Miniature<br />

Circuit Breakers<br />

(MCB)<br />

·······<br />

Since 1933, when Japan's first molded<br />

case circuit breaker was released, we<br />

have continuously provided circuit<br />

breakers with monitors to ensure<br />

uninterrupted power supplies, the world's<br />

first harmonics current proof and surge<br />

proof IC earth leakage circuit breakers,<br />

and other new products as needed. We<br />

have completed a 21st Century<br />

progressive super services for the circuit<br />

breaker. In doing so, we have focused on<br />

urgently required advanced technology<br />

and futuristic ease of use.<br />

■Circuit Protectors<br />

(CP)<br />

■Air Circuit Breakers<br />

(ACB)<br />

······<br />

······<br />

Compact, high-performance protectors<br />

against short-circuit and overload, and for<br />

control circuit operation for electronic<br />

equipment, office machinery, and<br />

machine tools.<br />

All models have electronic tripping relays<br />

ensuring high reliability and excellent<br />

performance.<br />

155


INFORMATION SERVICE VIA THE INTERNET<br />

■Catalogue<br />

●The latest catalogue and old editions are<br />

displayed for reading as is.<br />

■Technical Infomation<br />

●Access technical and maintenance data on<br />

our low-voltage switchgear.<br />

■Selection (Available soon)<br />

●Downloading to the latest CD-ROM software<br />

version (purchased separately) ensuring easy<br />

short circuit current calculation of our low-<br />

voltage switchgears and type selection.<br />

Downloading is available only those who purchase<br />

CD-ROM ''MELSHORT2'' for Mitsubishi selection.<br />

■Contact us at :<br />

●Information center<br />

Our area by area sales centers and contact sites<br />

around the world are conveniently located.<br />

●Technical support questions<br />

Access information on products, handling, and<br />

maintenance of low-voltage switchgear via the<br />

Internet.<br />

●Web problems: Comment<br />

If you have comments on the technical<br />

information service, please contact us via the<br />

Internet.<br />

■Standard<br />

●Access international standards<br />

for specific types.<br />

Related site<br />

We provide technical information on products via the<br />

Internet as well as low-voltage switch-gear technical<br />

information service.<br />

Mitsubishi Electric Corporation M's DINER Home page<br />

···http://www.melco.co.jp/index_e.htm<br />

Mitsubishi Electric Corporation GLOBAL Home page<br />

···http://www.mitsubishi.com/<br />

Mitsubishi Electric Europe B.V.–Germany<br />

···http://www.mitsubishi-automation.com/<br />

9<br />

156


MEMO


Country / Region Company Address Telephone<br />

Australia<br />

Belgium<br />

Chile<br />

Mitsubishi Electric Australia Pty. Ltd<br />

Emac S.A.<br />

RHONA S.A.<br />

348 Victoria Road, Rydalmere, N.S.W. 2116, Australia<br />

Industrialaan 1, B-1702 Groot-Bijgaarden, Belgium.<br />

Vte. Agua Santa 4211 Casilla 30-D (P.O. Box)<br />

Viña Del Mar. Chile<br />

+61-2-9684-7586<br />

+32-(0)2-4810211<br />

+56-32-320652<br />

China<br />

Colombia<br />

Denmark<br />

Egypt<br />

Germany<br />

Greece<br />

Hong Kong<br />

Indonesia<br />

Ireland<br />

Italy<br />

Laos<br />

Lebanon<br />

Myanmer<br />

Nepal<br />

New Zealand<br />

Norway<br />

Pakistan<br />

Philippines<br />

Poland<br />

Saudi Arabia<br />

Singapore<br />

Slovenia<br />

South Africa<br />

Spain<br />

Sweden<br />

Switzerland<br />

Taiwan<br />

Thailand<br />

The Netherlands<br />

Turkey<br />

U.K.<br />

Uruguay<br />

Venezuela<br />

Vietnam<br />

Mitsubishi Electric Automation (Shanghai)<br />

Limited<br />

Cra 53 No 29C-73 U.I.C.- Medellin.<br />

Proelectrico Representaciones S.A.<br />

COLOMBIA.<br />

Louis Poulsen CO. A/S<br />

Geminivej 32, DK-2670 Greve, Denmark.<br />

P.O. BOX: 165-11516, Maglis El-Shaab<br />

CAIRO ELECTRICAL GROUP<br />

Cairo-Egypt.<br />

Mitsubishi Electric Europe B.V. German Branch. Gothaer Strasse 8, 40880 Ratingen, Germany.<br />

Drepanias Antonios S.A.<br />

Mitsubishi Electric Automation (Hong Kong)<br />

Limited<br />

P.T.SAHABAT INDONESIA.<br />

Mitsubishi Electric Europe B.V. Irish Branch.<br />

Mitsubishi Electric Europe B.V. Italy<br />

MITSUBISHI ELECTRIC AUTOMATION<br />

KOREA CO., LTD.<br />

SOCIETE LAO IMPORT-EXPORT<br />

COMPTOIR D'ELECTRICITE<br />

GENERALE-Liban<br />

PEACE MYANMAR ELECTRIC CO., LTD.<br />

Watt & Volt House Co., Ltd.<br />

Melco Sales (N.Z.) Ltd.<br />

SCANELEC<br />

Prince Electric Co.<br />

EDISON ELECTRIC INTEGRATED, INC.<br />

MPL Technology Sp zo.o.<br />

CENTER OF ELECTRICAL GOODS<br />

MITSUBISHI ELECTRIC ASIA PTE LTD.<br />

INEA d.o.o.<br />

Circuit Breaker Industries LTD.<br />

Mitsubishi Electric Europe B.V.<br />

Spanish Branch.<br />

Euro Energy Components AB<br />

Trielec A G<br />

Setsuyo Enterprise Co., Ltd.<br />

UNITED TRADING & IMPORT CO. LTD.<br />

Imtech Marine & Offshore<br />

GTS<br />

Mitsubishi Electric Europe B.V.<br />

UK-Branch.<br />

Fierro Vignoli S.A.<br />

ADESCO C.A.<br />

SA GIANG TECHNO CO., LTD.<br />

52, Arkadias<br />

STR.GR 121 32. Peristeri Athens Greece.<br />

10/F Manulife Tower 169 Electric Road North<br />

Point. Hong Kong.<br />

JL Muara Karang Selatan Blok A/Utara No.1<br />

kav. NO.11 P.O. Box 5045/Jakarta/11050.<br />

Jakarta Indonesia.<br />

Westgate Business Park, Ballymount, Dublin 24, Ireland.<br />

C.D.Colleoni-P.Perseo lng.2, Via Paracelso 12<br />

1-20041 Agrate Brianza (M1)<br />

2 Fl. Dong Seo Game Channel Bldg., 1F 660-11<br />

Deungchon-Dong, Kanguseo-Ku, Seoul, 157-030 Korea<br />

43-47 Lane Xang Road P.O. BOX 2789 VT<br />

Vientiane, Laos<br />

Cebaco Center-Block A. Autostrade Dora,<br />

P.O. BOX: 11-2597 Beirut-Lebanon.<br />

NO. 137/139 Botataung Pagoda Road,<br />

Botataung Town Ship 11161, Yangon, Myanmar.<br />

KHA 2-65, Volt House Dilli Bazar Post Box: 2108,<br />

kathmandu, Nepal<br />

1 Parliament Street Lower Hutt. New Zealand.<br />

Leirvikasen 43B, N5020 Bergen, Norway.<br />

16 Brandreth Road Lahore 54000. Pakistan.<br />

24th Fl. Galleria Corporate Center Edsa Cr, Ortigas Ave.<br />

Quezon City, Metro Manila. Philippines.<br />

ul. Sliczna 36 31-444 Krakow, Poland.<br />

P.O. BOX: 15955, Riyadh 11454,<br />

Saudi Arabia.<br />

307 Alexandra Road #05-01/02 Mitsubishi<br />

Electric Building Singapore 159943<br />

Ljubljanska 80, SI-61230 Domzale, Slovenia.<br />

Private Bag 2016. Isando 1600, Johannesburg, South Africa<br />

Caretera De Rubi 76-80, 08190 - Sant Cugat Del Valles<br />

(Barcelona) Spain<br />

Box 103 48 S-434 24 Kungsbcka, Sweden.<br />

Mühlentalstrasse 136, 8201 Schaffhausen,<br />

Switzerland<br />

6F, NO. 105 Wu-Kung 3rd rd., Wu-Ku Hsiang,<br />

Taipei Hsien Taiwan<br />

77/12 Bumrungmuang Road, Klong Mahanak,<br />

Pomprab Bangkok 10100.<br />

Postbox 5054, NL-3008 AB-Rotterdam, Netherlands.<br />

Fahri Gizden Sokak, Hacaloglu Apt. No.22/6<br />

TR-80280 Gayrettepe/Istanbul, Turkey.<br />

Travellers Lane, Hatfield, Herts, AL10 8xB, U.K.<br />

P.O. box 20022/Suc Upae, Montevideo. Uruguay.<br />

Lle 8, Calpon Elinsu,<br />

La Urbina-EDO, Miranda P.O.<br />

BOX 78034 Caracas 1074A., Venezuela<br />

47-49 Hoang Sa St., Da Kao Ward, D.1, HCMC<br />

+86-(0)21-6120-0808<br />

+57-4-235-00-28<br />

+45-(0)43-95-95-95<br />

+20-2-7961337<br />

+49-(0)2102-4860<br />

+30-1-57-81-599-699<br />

+852-28878870<br />

+62-(0)21-6621780<br />

+353-(0)1-4505007<br />

Israel GINO INDUSTRIES LTD. 26, Ophir street, IL-32235 Haifa, Israel +972-(0)4-867 06 56<br />

Korea<br />

+82-2-3668-6567<br />

Malaysia<br />

mittric Sdn Bhd<br />

80 Xin Chang Road 4th Floor<br />

Shanghai Intelligence Fortune Leisure Plaza<br />

Huang Pu district Shanghai 200003<br />

P.R.China<br />

12A, Jalan Pemberita U1/49, Temasya Industrial Park,<br />

Glenmarie, 40150 Shah Alam, Selangor, Malaysia<br />

+390-39-60-531<br />

+856-21-215043, 21-215110<br />

+961-1-240455<br />

+603-5569-3748<br />

+95-(0)1-202589, 202449, 202590<br />

+977-1-411330<br />

+64-4-569-7350<br />

+47-55-506000<br />

+92-(0)42-7654342<br />

+63-(0)2-643-8691<br />

+48-(0)12-632-28-85<br />

+966-1-4770149<br />

+65-6473-2308<br />

+386-(0)17-21 80 00<br />

+27-11-928-2000<br />

+34-93-595-3131<br />

+46-(0)300-69 00 40<br />

+41-(0)52-6258425<br />

+886-(0)2-2298-8889<br />

+66-223-4220-3<br />

+31-(0)10-487 19 11<br />

+90-(0)212-2674011<br />

+44-(0)1707-276-100<br />

+598-2-92-08-08<br />

+58-2-241-7634<br />

+84-8-910 4763 / 4758 / 4759<br />

Safety Tips : Be sure to read the instruction manual fully before using this product.<br />

FACTORY AUTOMATION SYSTEM: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN<br />

Y-0642A 0701 printed in Japan(MDOC)<br />

Revised publication, effective Jan. 2007.<br />

Specifications subject to change without notice.<br />

This pamphlet is made from recycled paper.