<strong>Installation</strong><br />

Axle Vent <strong>Installation</strong><br />

1. Install a 1/4" NPT male to 3/8" NTA fitting in the 1/4"<br />

pipe thread located on the axle for venting.<br />

2. Run 3/8" OD Nylon Air Brake Tubing to the frame and<br />

position the end facing down to prevent contamination.<br />

See illustration below.<br />

3. Secure tubing as required.<br />

Vent Fitting<br />

1/4" NTP to 3/8"<br />

Nylon Tubing<br />

Adapter<br />

Trailer Frame Rail<br />

Front of Trailer<br />

Axle Vent Hose<br />

(minimum 3/8" OD<br />

nylon air brake tubing)<br />

Trailer<br />

Axle<br />

CAUTION: Position the end of the vent tube down to<br />

prevent contamination of the axle.<br />

Control Line <strong>Installation</strong><br />

A pressure protection value (PPV) is recommended between<br />

the trailer air supply tank and the Tire Maintenance System<br />

controller assembly. An existing suspension PPV can also be<br />

used to supply air to the suspension as well as the Tire Maintenance<br />

System.<br />

Proper Tire Maintenance System operation requires correct<br />

air line diameters and lengths. The following diagrams show<br />

air brake tubing lengths and sizes and associated fittings<br />

required to complete the system installation.<br />

CAUTION: To prevent twisting air line inside axle when<br />

tightening fittings to the axle hose fitting, use a wrench<br />

to hold the axle hose fitting.<br />

CAUTION: Proper Tire Maintenance System operation<br />

requires correct air line diameters and lengths. <strong>Installation</strong><br />

sizes and lengths must be within limits shown.<br />

CAUTION: Proper Tire Maintenance System operation<br />

requires correct air line connections. All junctions of<br />

two or more 1/4" lines MUST “upsize” to 3/8" line for<br />

adequate flow.<br />

CAUTION: To prevent contamination of the Tire Maintenance<br />

System, do not install fitting on the bottom of<br />

the air supply tank.<br />

Additional Axles<br />

For systems with 3 or 4 axles, observe the installation requirements<br />

as shown in the following diagrams. Extend the main 3/<br />

8" run as necessary. However, all total line lengths must still<br />

remain within the limits listed on the diagrams.<br />

CAUTION: Failure to properly install axle vent may<br />

result in wheel end pressurization and/or water ingestion<br />

which could cause wheel end failure.<br />