Swim Jets pump(S) timer – Europe only<br />
In some regions of Europe, a separate control is required for the swim jets pump(s) in order to conform to local<br />
electrical requirements. This control is designed to operate with either a 1-Phase or 3-Phase dedicated line input, and<br />
utilizes a single pneumatic air button to control the swim jet pump(s). Typical installations are illustrated below.<br />
Input Service<br />
230VAC, 1-Phase or 400VAC, 3-Phase (neutral required)<br />
Rating<br />
50Amp resistive load.<br />
Operation<br />
The first push of the air button turns on pump(s) and pressing again turns off pump(s). The control automatically turns<br />
off the pump(s) after 30 minutes.<br />
• Use copper conductors only<br />
• Do not lubricate relays<br />
• All controls must be installed by a licensed electrician according<br />
• Always refer to specific installation instructions located on inside cover of equipment<br />
SINGLE-PHASE INSTALLATION – 220V<br />
THREE-PHASE INSTALLATION – 400V or 380V<br />
NEuTRAL<br />
LINE<br />
NEuTRAL<br />
LINE 1<br />
LINE 2<br />
LINE 3<br />
1 OR 2 MOTORS uP TO 5 HP EACH<br />
1 MOTOR uP TO 10 HP<br />
IMPoRtant: NEuTRAL AND LINE 1 MuST BE 230VAC<br />
AIR SENSOR<br />
860010-0<br />
NEuTRAL 2<br />
NEuTRAL 1<br />
LINE 1<br />
SWITCHED 1<br />
LINE OuT 1<br />
725834-0 (10MM)<br />
725835-0 (30MM)<br />
BK<br />
RD<br />
NEuTRAL<br />
LINE 1<br />
1<br />
LINE 2<br />
2<br />
LINE 3<br />
3<br />
RD<br />
1<br />
2<br />
3<br />
LOAD 1<br />
LOAD 2<br />
LOAD 3<br />
BK<br />
410310-0<br />
GROuND<br />
Note: Ground connections are not shown and vary with installations.<br />