REMOTE Equipment<br />
REMOTE EQUIPMENT placement<br />
• The equipment should be located as close to the swim<br />
spa as possible to maximize jet performance<br />
• Whenever possible, install the pump(s) and control<br />
with heater below water level to ensure easy priming<br />
and maximize performance. Where above-grade<br />
equipment location is necessary, ensure that your<br />
swim spa is equipped with the optional REMOTE<br />
ABOVE-GRADE EQUIPMENT PACKAGE.<br />
• The distance of the swim spa support equipment from<br />
the unit should never exceed 3m (10 ft.) of pipe length,<br />
otherwise jet performance will be affected.<br />
• Piping diameter on pump lines must be 2.5 in. for inlet/<br />
suction pipes and 2 in. for outlet/pressure pipes with<br />
minimal use of elbows.<br />
• Install protective waterproof conduit to house<br />
applicable cords or line extensions such as the topside<br />
control cables, light wires or ozone tubing.<br />
• In climates where freeze/thaw occurs we recommend that<br />
remote plumbing lines be buried below the frost line and<br />
that pipe insulation is applied over all pipes that run from<br />
the swim spa to the remote equipment to help maintain<br />
energy efficiency.<br />
• The swim spa equipment is designed for indoor/out<br />
of the direct elements use. Your custom enclosure<br />
or other structure must be designed to provide<br />
protection for the swim spa support equipment from<br />
rain, snow, splash water, etc., but still designed in a<br />
manner to ensure adequate ventilation.<br />
above-Grade EQUIPMENT Placement<br />
(Aquaplay North America Only)<br />
In the event that you are plumbing your equipment in<br />
a remote location where the support equipment will be<br />
higher than the swim spa fill water level, you should have<br />
purchased the optional REMOTE ABOVE-GRADE EQUIPMENT<br />
PACKAGE consisting of:<br />
1 Self-priming pumps with strainer basket<br />
2 Topside control panel extension<br />
3 Light niche and extension<br />
It is the responsibility of the installer to provide any<br />
additional pipe or plumbing fittings that may be required.<br />
• The equipment should not be located further than 3m<br />
(10 ft.) from the swim jets, and must be placed in a dry,<br />
vented area, easily accessible for service.<br />
• The equipment should not be installed more than<br />
30 cm (12 in.) higher than the swim spa fill water level.<br />
• All field installed plumbing must meet minimum sizes<br />
as previously outlined in order to conform to regulated<br />
standards regarding safe inlet and outlet flows. If required,<br />
please call your dealer for more detailed drawings.<br />
Remote Equipment Plumbing Diagrams<br />
Inlet/Suction Side Plumbing Connections<br />
Outlet/Pressure Side Plumbing Connections<br />
Pump 1 Pump 1<br />
P3<br />
P1<br />
P2<br />
2 1/2" Dia.<br />
2" Dia.<br />
P3<br />
P1<br />
P2<br />
Pump 2 & 3 Pump 2 & 3<br />
P3<br />
P1<br />
P2<br />
2 1/2" Dia.<br />
2" Dia.<br />
P3<br />
P1<br />
P2<br />
9