REMOTE Equipment<br />

REMOTE EQUIPMENT placement<br />

• The equipment should be located as close to the swim<br />

spa as possible to maximize jet performance<br />

• Whenever possible, install the pump(s) and control<br />

with heater below water level to ensure easy priming<br />

and maximize performance. Where above-grade<br />

equipment location is necessary, ensure that your<br />

swim spa is equipped with the optional REMOTE<br />

ABOVE-GRADE EQUIPMENT PACKAGE.<br />

• The distance of the swim spa support equipment from<br />

the unit should never exceed 3m (10 ft.) of pipe length,<br />

otherwise jet performance will be affected.<br />

• Piping diameter on pump lines must be 2.5 in. for inlet/<br />

suction pipes and 2 in. for outlet/pressure pipes with<br />

minimal use of elbows.<br />

• Install protective waterproof conduit to house<br />

applicable cords or line extensions such as the topside<br />

control cables, light wires or ozone tubing.<br />

• In climates where freeze/thaw occurs we recommend that<br />

remote plumbing lines be buried below the frost line and<br />

that pipe insulation is applied over all pipes that run from<br />

the swim spa to the remote equipment to help maintain<br />

energy efficiency.<br />

• The swim spa equipment is designed for indoor/out<br />

of the direct elements use. Your custom enclosure<br />

or other structure must be designed to provide<br />

protection for the swim spa support equipment from<br />

rain, snow, splash water, etc., but still designed in a<br />

manner to ensure adequate ventilation.<br />

above-Grade EQUIPMENT Placement<br />

(Aquaplay North America Only)<br />

In the event that you are plumbing your equipment in<br />

a remote location where the support equipment will be<br />

higher than the swim spa fill water level, you should have<br />

purchased the optional REMOTE ABOVE-GRADE EQUIPMENT<br />

PACKAGE consisting of:<br />

1 Self-priming pumps with strainer basket<br />

2 Topside control panel extension<br />

3 Light niche and extension<br />

It is the responsibility of the installer to provide any<br />

additional pipe or plumbing fittings that may be required.<br />

• The equipment should not be located further than 3m<br />

(10 ft.) from the swim jets, and must be placed in a dry,<br />

vented area, easily accessible for service.<br />

• The equipment should not be installed more than<br />

30 cm (12 in.) higher than the swim spa fill water level.<br />

• All field installed plumbing must meet minimum sizes<br />

as previously outlined in order to conform to regulated<br />

standards regarding safe inlet and outlet flows. If required,<br />

please call your dealer for more detailed drawings.<br />

Remote Equipment Plumbing Diagrams<br />

Inlet/Suction Side Plumbing Connections<br />

Outlet/Pressure Side Plumbing Connections<br />

Pump 1 Pump 1<br />

P3<br />

P1<br />

P2<br />

2 1/2" Dia.<br />

2" Dia.<br />

P3<br />

P1<br />

P2<br />

Pump 2 & 3 Pump 2 & 3<br />

P3<br />

P1<br />

P2<br />

2 1/2" Dia.<br />

2" Dia.<br />

P3<br />

P1<br />

P2<br />

9