12<br />

5.3 Burner head<br />

The choice of burner head depends on the flame shape, gas type and variant.<br />

Burner head<br />

code letter<br />

Furnace temperature<br />

[°C]<br />

Air temperature2)<br />

[°C]<br />

Flame shape<br />

Control range Low fi re l λ1)<br />

Continuous Staged<br />

Normal R 1:10 1:10 > 1.05 0.8 to 1.3 50 to 350 20 to 150 4)<br />

Long H 1:10 1:10 > 1.3 0.8 to 1.5 500 to 1600 5) 20 to 450<br />

Flat K 3) – 1:10 > 1.05 0.9 to 1.2 50 to 100 4) 20 to 50 4)<br />

1) Indicates the rough range for the max. connection rating. For precise values for the individual versions, see burner diagrams.<br />

The ranges were determined for an ionization current of ≥ 5 µA. Extension of the working range using a UV sensor.<br />

2) The gas fl ow rate should be reduced in accordance with the enthalpy gain of the preheated combustion air.<br />

3) In conjunction with a burner quarl, for use as a radiant burner.<br />

4) Higher temperatures available on request.<br />

5) From a furnace temperature of > 1450°C, the control range is limited.<br />

Gas type<br />

Code letter<br />

Calorifi c value range<br />

[kWh/m 3 (n)]<br />

Density ρ<br />

[kg/m 3 ]<br />

Natural gas L and H quality B 8 to 12 0.7 to 0.9<br />

Propane, propane/butane, butane M 25 to 35 2.0 to 2.7<br />

Propane, propane/butane, butane G 1) 25 to 35 2.0 to 2.7<br />

Coke oven gas, town gas D 4 to 5 0.4 to 0.6<br />

Low calorifi c value gas L 2) 1.7 3 to 3 0.9 to 1.15<br />

1) For λ < 0.9 or when using the <strong>BIO</strong> 50.<br />

2) Not for all burner sizes. Burner capacity is limited to 50 % of the rated capacity.<br />

3) Calorifi c value range < 1.7 on request.<br />

Variant Code letter Output<br />

[kW]<br />

Ignition lance L approx. 1.5<br />

Reduced max. connection rating R –<br />