Project planning information<br />

22<br />

6.6 Purging air/cooling air<br />

Cooling air at 20°C<br />

Air volume at rated capacity [%]<br />

Purging/cooling air volume for burners<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

<strong>BIO</strong>/<strong>ZIO</strong>..K<br />

<strong>BIO</strong>, <strong>ZIO</strong><br />

<strong>BIO</strong>/<strong>ZIO</strong>..KB..E<br />

0<br />

0<br />

700 800 900 1000 1100 1200 1300 1400<br />

Kiln temperature °C<br />

While the burner is switched off and depending on the furnace<br />

temperature, there must be a certain air flow in order to ensure<br />

safe ignition and monitoring of the burners, and for cooling<br />

the burner components.<br />

The relative air volume in percentage values, based on the<br />

air volume for the rated capacity of the relevant size, is given<br />

in the Purging/cooling air volume for burners diagram. For<br />

hot air, the values on the right-hand axis are based on the<br />

standard air volume for the relevant rated capacity.<br />

The air fan must remain switched on until the furnace has<br />

cooled down completely.<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

Cooling air at 450°C<br />

Air volume* at rated capacity [%]<br />

* The cooling air volumes measured in standard<br />

cubic metres are converted into percentage values.<br />

6.7 Emissions<br />

NOX<br />

[mg/m3]<br />

5% O2<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

70<br />

50<br />

H (450 °C)<br />

R, K (20 °C)<br />

H (20 °C)<br />

K (450 °C)<br />

10 50 100<br />

Capacity [%]<br />

Flame shape:<br />

R = Normal<br />

H = Long<br />

K = Flat<br />

T Furnace<br />

= 1000°C<br />

Emissions for cold-air operating mode do not exceed the limits<br />

stipulated by the German Clean Air Directive.<br />

NO X values depend on the temperature, burner head, combustion<br />

chamber, furnace chamber, λ value and output (NO X<br />

values on request).<br />

If operated with LPG, NO X values are approx. 25% higher.<br />

<strong>BIO</strong>, <strong>BIO</strong>A, <strong>ZIO</strong> · Edition 05.10