Project planning information<br />
22<br />
6.6 Purging air/cooling air<br />
Cooling air at 20°C<br />
Air volume at rated capacity [%]<br />
Purging/cooling air volume for burners<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
<strong>BIO</strong>/<strong>ZIO</strong>..K<br />
<strong>BIO</strong>, <strong>ZIO</strong><br />
<strong>BIO</strong>/<strong>ZIO</strong>..KB..E<br />
0<br />
0<br />
700 800 900 1000 1100 1200 1300 1400<br />
Kiln temperature °C<br />
While the burner is switched off and depending on the furnace<br />
temperature, there must be a certain air flow in order to ensure<br />
safe ignition and monitoring of the burners, and for cooling<br />
the burner components.<br />
The relative air volume in percentage values, based on the<br />
air volume for the rated capacity of the relevant size, is given<br />
in the Purging/cooling air volume for burners diagram. For<br />
hot air, the values on the right-hand axis are based on the<br />
standard air volume for the relevant rated capacity.<br />
The air fan must remain switched on until the furnace has<br />
cooled down completely.<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
Cooling air at 450°C<br />
Air volume* at rated capacity [%]<br />
* The cooling air volumes measured in standard<br />
cubic metres are converted into percentage values.<br />
6.7 Emissions<br />
NOX<br />
[mg/m3]<br />
5% O2<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
70<br />
50<br />
H (450 °C)<br />
R, K (20 °C)<br />
H (20 °C)<br />
K (450 °C)<br />
10 50 100<br />
Capacity [%]<br />
Flame shape:<br />
R = Normal<br />
H = Long<br />
K = Flat<br />
T Furnace<br />
= 1000°C<br />
Emissions for cold-air operating mode do not exceed the limits<br />
stipulated by the German Clean Air Directive.<br />
NO X values depend on the temperature, burner head, combustion<br />
chamber, furnace chamber, λ value and output (NO X<br />
values on request).<br />
If operated with LPG, NO X values are approx. 25% higher.<br />
<strong>BIO</strong>, <strong>BIO</strong>A, <strong>ZIO</strong> · Edition 05.10