5.5 Calculating the burner length<br />
L1<br />
L2<br />
L O<br />
BKL<br />
Legend<br />
L1 = Burner tube length<br />
L2 = Position of burner head<br />
L O = Furnace wall thickness<br />
BKL = Burner chamber length (L 10 )<br />
5.5.1 Burners in burner quarls<br />
The position of the burner head (L2) should be appropriately selected, so that the<br />
burner head extends into the burner quarl.<br />
The position of the burner head is available in the following lengths:<br />
35, 135, 235, 335 mm, etc.<br />
The burner chamber length BKL for ensuring optimum flame formation and stable<br />
burner operation can be found in the [Data table – p. 15].<br />
Determine the position of the burner head: L2 = L O - BKL<br />
The burner tube length (L1) is predefined, depending on the flame shape R, K or<br />
H: R, K burner head:<br />
L1 = L2 + 15 mm, H burner head: L1 = L2 + 65 mm<br />
Example<br />
Desired burner quarl type = B, desired flame shape = R (normal).<br />
Selected burner with 90 kW capacity = <strong>BIO</strong> 65,<br />
suitable for burner chamber length (BKL) = 115 – 265 mm.<br />
Furnace wall thickness L O = 340 mm.<br />
Calculate shortest length L2:<br />
Select maximum burner chamber length: BKL = 265 mm.<br />
L2 = LO - BKL = 340 mm - 265 mm = 75 mm.<br />
Compare L2 (here 75 mm) with standard lengths (35, 135, 235, 335 mm, etc.).<br />
Select next longest standard length L2: L2 = 135 mm.<br />
Test whether the burner chamber length BKL fits:<br />
L O - L2 = BKL ➔ 340 mm - 135 mm = 205 mm.<br />
205 mm falls into the burner chamber length range for burners <strong>BIO</strong> 65:<br />
115 – 265 mm – see [Data table – p. 15].<br />
<strong>BIO</strong>, <strong>BIO</strong>A, <strong>ZIO</strong> · Edition 05.10