20.11.2014 Views

BIO, BIOA, ZIO - Combustion 911

BIO, BIOA, ZIO - Combustion 911

BIO, BIOA, ZIO - Combustion 911

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical data<br />

26<br />

Burners Rated capacity 1) Burner quarl type Flame shape code letter Flame length 2) Flame outlet velocity 3)<br />

kW cm m/s<br />

<strong>ZIO</strong> 200 1000 A R 100 25<br />

<strong>ZIO</strong> 200 1000 B R 130 85<br />

<strong>ZIO</strong> 200 1000 B H 200 80<br />

<strong>ZIO</strong> 200 1000 D K – –<br />

1) Higher capacities are possible – either on request or see burner diagrams at www.docuthek.com.<br />

2) Measured in the burner quarl from the front edge of the burner quarl. The fl ame diameter is approx. one to two times that of the burner tube or burner<br />

quarl outlet.<br />

3) Refers to rated capacity, with a fl ame temperature of 1600°C for R burner head and 1500°C for H burner head. The fl ow velocity is increased when the<br />

outlet diameter of the burner quarl is reduced. The rated capacity must then be adjusted to the outlet diameter.<br />

<strong>BIO</strong>, <strong>BIO</strong>A, <strong>ZIO</strong> · Edition 05.10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!