<strong>MIL</strong>-<strong>PRF</strong>-<strong>13830B</strong><br />

APPENDIX C<br />

C.3.8.5 Adhesion. The coated optical surface shall show no evidence of coating<br />

removal when cellophane tape is pressed firmly against the coated surface and<br />

quickly removed at an angle normal to the coated surface.<br />

C.4. VERIFICATION<br />

C.4.1 General provisions. Unless otherwise specified in the contract or purchase<br />

order, the supplier is responsible for the performance of all inspection requirements<br />

as specified herein. Except as otherwise specified, the supplier may utilize his own<br />

facilities or any other facilities suitable for the performance of the inspection<br />

requirements specified herein, unless disapproved by the Government. The<br />

Government reserves the right to perform any of the inspections set forth in the<br />

specification where such inspections are deemed necessary to assure that supplies<br />

and services conform to prescribed requirements (See C.6.2).<br />

C.4.1.1 Witness piece. Unless otherwise specified, witness pieces as defined in<br />

C.4.1.2 or coated components may be used to test the optical and durability<br />

requirements of the coated component (See C.4.2, C.4.3 and C.6.2). The witness<br />

pieces shall be positioned in the coating chamber such that they represent the optical<br />

and durability characteristics of the whole evaporated lot (See C.6.3). The<br />

Government reserves the right to test the actual coated component with the same<br />

test to which the witness pieces were subjected, except in the case where the known<br />

Knoop hardness of the coated component is less than 450 kg/mmì, the moderate<br />

abrasion test of C.4.5.11 shall be utilized. Should a component fail, even through the<br />

representative witness pieces pass the test, the lot shall be rejected.<br />

C.4.1.2 Characteristics of the witness piece. When the witness pieces are used to<br />

test the optical and durability requirements of the coated component they shall<br />

exhibit the following characteristics:<br />

a. The witness piece shall be such that it presents no difficulty in<br />

measuring and testing the optical and durability requirements of the<br />

coating.<br />

b. The witness piece shall have a surface finish similar to that of the<br />

component to be coated.<br />

c. The witness piece shall simulate the axial thickness of the component<br />

by either computational methods or using a witness piece that has<br />

the same thickness as the coated component for the measurement of<br />

transmission characteristics.<br />

43<br />

Source: http://www.assistdocs.com -- Downloaded: 2006-05-24T15:32Z<br />

Check the source to verify that this is the current version before use.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!