www.krohne.com<br />

© KROHNE 11/2002 7.02398.23.00<br />

GR<br />

<strong>M10</strong> <strong>Signal</strong> <strong>converter</strong><br />

hazardous-duty version EEx d<br />

for variable-area flowmeters H250/H54<br />

II2G<br />

Fully equipped<br />

● direct sensing of float position<br />

● current output 4 ... 20 mA in two-wire technology / HART<br />

● HART communication<br />

● two galvanically isolated binary outputs with selectable function:<br />

● switch contact with NAMUR level to DIN 19234<br />

● switch contact 24 V DC, open collector<br />

● pulse output 10 Hz<br />

● galvanically isolated binary input with function<br />

● totalizing counter reset<br />

● 3-line, 12-character alphameric display<br />

● operator control optionally by way of<br />

bar magnet (no need to open display) or keys (opened display)<br />

Variable area flowmeters<br />

Vortex flowmeters<br />

Flow controllers<br />

Electromagnetic flowmeters<br />

Ultrasonic flowmeters<br />

Mass flowmeters<br />

Level measuring instruments<br />

Communications technology<br />

Engineering systems & solutions<br />

Switches, counters, displays and recorders<br />

Heat metering<br />

Pressure and temperature


<strong>Signal</strong> <strong>converter</strong> <strong>M10</strong><br />

The H250/H54 variable-area flowmeter is equipped with an electronic<br />

signal <strong>converter</strong> <strong>M10</strong> of hazardous-duty design EEx d (flameproof<br />

enclosure). There is no magnetic coupling nor pointer. The position of<br />

the float is sensed directly.<br />

The display can be adjusted using a bar magnet without having<br />

to open the front cover.<br />

Alternatively, adjustment can be done via the HART interface.<br />

Technical Data<br />

<strong>M10</strong> display, general<br />

Ambient temperature (*)<br />

-25 to +75°C (other temperatures on request)<br />

Protection (EN60529 / IEC 529) IP 67<br />

General approval PTB 01 ATEX 1154<br />

Explosion protection<br />

EEx d IIC T6 … T1 / II2G<br />

Accuracy for H250 Class 1.6 to VDI / VDE 3513<br />

Accuracy for H54 Class 1.0 to VDI / VDE 3513<br />

(*) Display contrast diminishes outside temperature range of 0 ... 60°C<br />

Current output<br />

two-wire technology (polarized)<br />

Power supply 24 V DC +/- 30%<br />

<strong>Signal</strong> output current<br />

4 ... 20 mA (0 ... 100% flow)<br />

NAMUR failure signal<br />

22 mA<br />

Power effect < 0.1 %<br />

Ext. resistance dependence < 0.1 %<br />

Temperature effect<br />

< 5µA / K<br />

Ext. resistance / load impedance<br />

R ≤ 630 ohms at max. power<br />

R ≥ 250 ohms with HART communication<br />

Binary outputs (B1 and B2)<br />

Galvanically isolated, 720 V DC<br />

Mode Switching output with signalling current to NAMUR or<br />

Switching output open collector<br />

Configurable as switching contact open / closed or<br />

pulse output max. 10 pulses per second<br />

Switching output, NAMUR power supply 8V<br />

signalling current >3 mA limit point not crossed;<br />