2. <strong>CU</strong> <strong>300</strong> as an alarm unit<br />

2.1 Description<br />

When the <strong>CU</strong> <strong>300</strong> is connected to an SQE pump,<br />

any alarm will be indicated by one of the eight red<br />

indicator lights on the <strong>CU</strong> <strong>300</strong>.<br />

The indications are based on signals from the motor<br />

<strong>and</strong> from sensors, if installed. The individual alarms<br />

are described in detail in section 11. Alarm functions.<br />

It is possible to connect an external alarm signal<br />

transmitter <strong>and</strong> an external on/off switch, see section<br />

2.5 Electrical connection concerning connection, etc.<br />

Fig. 2 shows an example of an installation with the<br />

<strong>CU</strong> <strong>300</strong> as an alarm unit.<br />

Fig. 2<br />

2.4 Mounting the <strong>CU</strong> <strong>300</strong><br />

The <strong>CU</strong> <strong>300</strong> is designed for wall mounting.<br />

The box has six mounting holes (ø4), see fig. 3<br />

(dimensions stated in mm).<br />

The <strong>CU</strong> <strong>300</strong> must be mounted:<br />

• horizontally (see fig. 3) to allow condensed water,<br />

if any, to escape.<br />

• on a plane surface to avoid deformation of the<br />

box.<br />

Fig. 3<br />

104.5<br />

104.5<br />

TM01 2824 2498<br />

100<br />

TM01 3150 4601<br />

140.5<br />

The <strong>CU</strong> <strong>300</strong> is supplied with a set of gaskets for the<br />

Pg screwed connections.<br />

The gaskets are to be used for the connection of<br />

cables/wires to ensure tight connections (IP 55) <strong>and</strong><br />

cable relief.<br />

The <strong>CU</strong> <strong>300</strong> functions as an alarm unit for the pump.<br />

Furthermore, it is possible to communicate with the<br />

pump via the remote control R100, see also section<br />

12. <strong>CU</strong> <strong>300</strong> with R100.<br />

2.2 <strong>Installation</strong><br />

2.3 Location<br />

Before starting any work on the <strong>CU</strong> <strong>300</strong>,<br />

make sure that the electricity supply has<br />

been switched off <strong>and</strong> that it cannot be accidentally<br />

switched on.<br />

The <strong>CU</strong> <strong>300</strong> can be placed both indoors <strong>and</strong> outdoors.<br />

It must not be exposed to direct sunlight.<br />